Jbc Cd-sqe User Manual

Page 1
www.jbctools.com
INSTRUCTION MANUAL
Precision Soldering Station
Ref. CD-SQE
Page 2
Packing List
The following items are included:
CD Control Unit ........................................ 1 unit
Ref. CD-1E (120V) CD-2E (230V ) CD -9 E (100V)
Power Cord ................................................ 1 unit
Ref. 0009417 (100V/120V) 0009401 (230V)
Precision Purpose Handle .................... 1 unit
Ref. T210-A
Brass Wool ................................................. 1 unit
Ref. C L6 210
Sponge ........................................................ 1 unit
Ref. S0354
2
Manual ......................................................... 1 unit
Ref. 0022910
www.jbctools.com
INSTRUCTION MANUAL
Precision Soldering Station
Ref. CD-SQE
Page 3
Features
www.jbctools.com
Quick Tip Changer
Process Screen
Adjustable Stand: Intelligent Heat Management
Cable collector
Tip Cleaner brass wool with antisplash membrane
USB-B connector
Precision Purpose
Handle
Ref. T210-A
Main switch Fuse
Power Socket
Equipotential connection
3
Page 4
Adjustable stand Cable collector (Ref. CC3702)
Adjust the tool stand to suit your work position.
Fix the cable on the collector so that the working area is free of cable.
Tip Cleaner
Select the option to suit your needs and improve the thermal transfer of the tip.
Splashguard
Ref . 0017576
When using the brass wool, it prevents splashing of solder particles
Antisplash Membrane
Ref. 0 0175 74
Prevents splashing and keeps the work area clean.
Brass Wool
Ref. C L6 210
Very effective cleaning method. Leaves a small layer of solder on the tip, preventing oxidation between cleaning and rewetting.
4
If the tip is ver y dirty, JBC first recommends cleaning it with the wiper to remove excess solder.
Wiper
Ref. CL0160
A temperature resistant receptacle for removing excess solder by gently
tapping or wiping.
Page 5
Removing the Splashguard
www.jbctools.com
1. Unlock the splashguard.
More cleaning options (not supplied):
Inox Wool
Ref. CL6205 Provides a superior cleaning of the tip.
Wiper
Ref. CL0160
2. Lift off.
Lock
Metal Brush
Ref. CL6220 When used carefully, it provides a more thorough cleaning.
Sponge
Ref. S0354
Tapping:
Tap gently to remove excess solder.
Wiping:
Use the slots to remove remaining particles.
The least harmful cleaning method. Keep the sponge damp with distilled water when working to avoid tip we a r.
5
Page 6
ø 1
ø 1,5
ø 3,5
Quick Tip Changer
Save time and change cartridges safely without switching the station off.
1. Removing 2. Inserting 3. Fixing
C
B
Place the handpiece in the extractor and pull to remove the cartridge.
Place the handpiece on top of the new car tridge and press down slightly.
Use the holes for fixing the cartridge* as follows:
A. For straight C210. B. For curved C210. C. For C245.
*Important
It is necessary to insert the cartridges as far as the mark for a proper connection.
Mark
Compatible cartridges
The CD-S stations work with C210 cartridges and T210 handles. Find the model that best suits your soldering needs in w ww.jbctools.com
A
B
Conical Chisel Conical
bent
A
Bevel Special models
6
Page 7
www.jbctools.com
USB Connector
Download the latest software from our website to update your soldering station.
JBC Updater
www.jbctools.com/software.html Update the station software via USB connection:
Cable USB AB
JBC Manager software
JBC Manager
www.jbctools.com/manager.html Manage and monitor as many stations as your PC can handle by using the JBC Manager. You can export data to another PC.
any JBC
Cable USB AB
USB
Hub
JBC Manager software
Manager Settings
Change settings for a group of JBC stations at the same time.
Register Settings
Create graphs of the soldering process in real time which show power and temperature data.
station
7
Page 8
Operation
The JBC Most Efficient Soldering System
This revolutionar y technology is able to recover tip temperature extremely quickly. This allows the user to work at a lower temperature. As a result, tip life increases by 5.
1. Wo rk 2. Sleep 3. Hibernation
Long time in the stand
When the tool is lifted from the stand the tip will heat up to the selected temperature.
Selected temp
350
Power 5%
· Change temperature (from 90 to 450ºC)
· Select temperature levels
· Fix one temperature
350 oC
0
c
When the tool is in the stand, the temperature falls to the preset sleep temperature.
Sleep
0
c
350
Sleep temp 150oC
· Change Sleep temperature
· Set Sleep delay (from 0 to 9 min or no Sleep)
After longer periods of inactivity, the power is cut off and the tool cools down to room temperature.
Hibernation
0
c
350
Tool in the stand, no heat
· Change Hibernation delay (from 0 to 35 min)
8
Page 9
Control Process
Work Screen
www.jbctools.com
The work screen provides useful information of tool status in real time.
Menu Screen
Default PIN: 0105
Fixed temp.
Levels ºC
Selected temp.
350 oC
270 350 400
350 oC
350
Power 5%
Main menu
Exit
1 Reset settings
2
Station settings
3
Tool settings
4 Counters
5
Program version
Displays a specific fixed temp.
Shown when you have selected temp. levels. T he values must be adjusted for the task.
0
c
-10
“Temp. Adjust ” parameter. It provides a more precise adjustment between the selected temp and the actual one.
Station settings
1 Temp unit 2
Maximum temp 4000C
3
Minimum temp 2000C
4
Metronome ----
5 Help text OFF 6 Beep ON 7
Change PIN
Celsius
Back
Tool settings
1
Fix one temp -----
2
Temp levels set OFF
3
Sleep delay 0 min
Tool 210
4
Sleep temp 1500C
5
Hibernation delay 10 min
6
Temp adjust + O OC
Back
Tool 210
Counters
1
Plugged hours 0
2
Working hours 0
3
Sleep hours 0
4
Hibernation hours 0
5
No tool hours 0
6 Sleep cycles
0
Back
9
Page 10
Parameters
Be careful when using these parameters. They can reduce tip life if not used properly. Please follow the recommended guidelines:
Station Settings
Temperature unit
Celsius (ºC) or Fahrenheit (ºF)
Maximum temperature
Set the maximum temperature to work with. Max. temp by default is 400°C (750°F). This is considered high enough to work with most lead-free applications.
Minimum temperature
Set the minimum temperature to work with. Min. temp. by default is 200ºC (392ºF). This is consi­dered to be a proper star ting point for leaded applications.
Metronome
This activates a beep sound. Frequencies vary from 1 to 50 seconds.
Recommendations Parameter description
N/a
The station temperature range is 90-450ºC (190-840ºF). Change the temperature limits when working with less common applications such as low / high melting point soldering (HMP) or plastics (e. g. riveting).
Useful for setting a work rate in repetitive jobs. The beep lets you know the length of time the tip must be in contact with the soldering joint.
Warnings
In most cases, working with temperatures over 400°C (750°F) can damage the PCB and its components. Even in short time periods of tip contact with the soldering joint, the flux may not work properly and could seriously reduce tip life. If the solder joint requires more power (e.g. multila­yered or high dissipation boards), JBC strongly recommends using other aids like preheaters.
N/a
Help text
Activate this parameter to receive info from the system.
Beep
Enable/disable the beep sound of the keypad.
Change pin
Change the default security PIN number (0105).
10
N/a
N/a
The PIN must be entered every time a parameter is changed.
N/a
N/a
N/a
Page 11
Tool Settings
www.jbctools.com
Fix one temperature
Fix a value within the temperature range of the station (90 - 450ºC / 190 - 840ºF).
Temperature levels set
Similar to “Fix one temp” parameter. In this case, the user can set up to 3 values for different power requirements.
Sleep delay
Set the time that the tool will remain at the selected tempe­rature when in the stand be­fore entering sleep mode. The tip temperature will then drop to the Sleep temperature.
Recommendations Parameter description
Ideal for soldering more than one component at a specific temperature. The station will reject any attempt to change the temperature.
This allows a quick change between 3 different tempe­ratures. Set them according to the allowed values for your soldering applications.
Because our tools reach the working temperature from the deafult Sleep mode in only a few seconds, this parameter is preset to 0 min. Once the tool is returned to the stand the temperature will automatically drop to the sleep temperature, extending tip life and avoiding oxidation. Retinning the tip before placing the tool in the stand will protect the tip and extend its life.
Warnings
N/a
N/a
Setting these parameters to higher values will unnecessarily accelerate oxidation and shor ten tip life especially when working with temperatures up to 450°C (840°F).
Sleep temperature
This is the set temperature the tip reaches when returned to the stand.
The sleep temperatures are set to achieve a balance between preventing oxidation and reaching the working tem­perature in a few seconds.
11
Page 12
Tool Settings
Parameter description Warnings
Hibernation Delay
Set the time the tool will remain at Sleep temperature before entering the Hiber­nation mode. At this time, the power supply is cut of f and the tip remains at room temperature.
Temp Adjustment
It provides a more precise adjustment between the selected temperature and the actual one.
Recommendations
This function completely protects the tip from oxidation during long periods of inactivi­ty while the tool is in the stand. Retinning the tip before pla­cing the tool in the stand also helps prevent oxidation and extends the life of the tip.
Set values within ±50°C (± 90°F) to achieve zero error. JBC strongly recommends the use of TID-A or TIA-A Thermometers to obtain precise readings.
Increasing the default value will accelerate oxidation and shorten the tip life.
When the user chan­ges the cartridge type, the parameter should be reset to 0°C/F or to the value needed for this cartridge. E.g. If a correction of +20°C (+36°F) is set for the C245966 (thick type) and then the user changes the cartridge for a C245030 (which is thinner) without resetting, they would be working at a temperature of +20°C (+36°F) lower for the C245030 which does not need any temperature adjustment.
12
Page 13
Maintenance
Before carrying out maintenance, always allow the equipment to cool.
- Clean the station screen with a glass cleaner or a damp cloth.
www.jbctools.com
- Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.
- Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status.
- Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation. Rusty and dirty surfaces reduce heat transfer to the solder joint.
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
1. Pull off the fuse holder and remove the
fuse. If necessar y use a tool to lever it off.
Clean periodically
2. Press the new fuse into the fuse holder and replace it in the station.
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
13
Page 14
Safety
It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.
- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Make sure that it is properly grounded
before use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode.
The soldering tip, the metal part of the tool and the stand may still be hot even when the station is turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Avoid the contact of flux with skin or eyes to prevent irritation
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when
working to avoid personal harm.
- Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced
physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
14
Page 15
www.jbctools.com
有害物质含量表
产品中有害物质的名称及含量
有害物质
部件名称
铅(Pb) 汞(Hg) 镉(Cd)
烙铁头 O O O O O O
手柄 O O O O O O
电源线 O O O O O O
主机 O O O O O O
电源插座 O O O O O O
保险丝 O O O O O O
主开关 O O O O O O
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
电位连接 X O O O O O
变压器 O O O O O O
线路板 X O O O O O
O 表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572 规定的限量要求以下。 X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572 规定的限量要求。
15
Page 16
Specifications
CD -1SQE 120V 50/60Hz. Input fuse: 2A. Output: 23,5V. Control Unit model: CD -1E CD-2SQE 230V 50/60Hz. Input fuse: 1A. Output: 23,5V. Control Unit model: CD-2E CD-9SQE 100V 50/60Hz. Input fuse: 2A. Output: 23,5V. Control Unit model: CD-9E
- Temperature Range: 90 - 450 °C (190 - 840 °F) (±5%)
- Idle Temp. Stability (still air): ±1.5 ºC / ±3 ºF
- Output Peak Power CD-SE: 40W
- Tip to ground resistance: <2 ohms
- Tip to ground voltage: <2mV RMS
- Ambient operating temp: 10 - 50 ºC / 50 - 122 ºF
- USB connector station-PC
- Control Unit Weight: 2,67Kg (5.88 lb)
- Control Unit Dimensions: 150 x 175 x 145 mm (5.9 x 6.9 x 5.7 in)
- Total Package: 234 x 234 x 258 mm / 3.10 kg
9.2 x 9.2 x 10.2 in / 6.82 lb
Complies with CE standards ESD protected housing “skin effect”
Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour. Warrant y does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
This product should not be thrown in the garbage. In accordance with the European directive 2002/96/EC, electronic equipment at the end of its life must be collected and returned to an authorized recycling facilit y.
www.jbctools.comwww.jbctools.com
0022910-0319
Loading...