jbc AD 2200 Instruction Manual

0455410-3
AD 2200
AD VANCED SOLDERING STATION
Index Page
English 1 Español 5 Français 9 Deutsch 13 Italiano 17
Instructions manual
CE Version
Cartridges
2245
See page 26 for range
AD 2200
Control Unit 230V Ref. 2200200
Handpiece 2045 Ref. 2045000
Handpiece 2245 Ref. 2245000
See page 27 for range
2210
Cartridges
Handpiece 2010 Ref. 2010000
Handpiece 2210 Ref. 2210000
2010
2045
ENGLISH
1
We appreciate the confidence you have placed in JBC in purchasing this station. It is manufactured to the most stringent quality standards in order to give you the best possible service. Before turning on your station, we recommend you to read these instructions carefully.
You have pursached a Advanced AD 2200 Control Unit. In order to complete the soldering station you should choose the suitable handpiece and cartridges for the task to do. The Control Unit is valid only for the handpieces 2010/2210 and 2045/2245 and corresponding cartridges.
Control Unit AD 2200 230V Ref.2200200
Cartridges
Extractor
Stand
Handpiece connector
Handpiece 2045 Ref. 2045000 Handpiece 2245 Ref. 2245000
Handpiece 2010 Ref. 2010000 Handpiece 2210 Ref. 2210000
Equipotential connector
2
ENGLISH
Technical specifications
- Temperature selection from 100 to 371°C (±5%).
- Power: 55W.
- Safety transformer, mains separator and double isolation, with integrated fuse of temperature protection.
- Input: 230V 50Hz. Output: 24V
- Electrical protection Class I.
- Total weight of unit: 2.6 Kgs.
- ESD protected housing. Typical surface resistance: 105-1011Ohms/ square.
-Complies with CE standards on electrical safety, electromagnetic compatibility and antistatic protection.
- Equipotential connector is earth connected to the plug feed of the station.
Structure of Advanced soldering stations system
The Advanced series has 3 basic modules giving you full flexibility for choosing what you need for the work in hand, the modules being supplied separately .
Control unit
- AD 2200 230V Ref. 2200200 Handpieces
- 2010 Ref. 2010000 Power: 20W. For high precision work, SMD, etc.
- 2210 Ref. 2210000 Power: 20W. For high precision work, SMD, etc.
- 2045 Ref. 2045000 Power: 50W. For general soldering work.
- 2245 Ref. 2245000 Power: 50W. For general soldering work.
Two versions of soldering iron handpieces covered with heat isolater are available:
- 2045 Thermo-isolated handpiece ref. 2045110.
- 2245 Thermo-isolated handpiece ref. 2245110.
Cartridges
- Range of cartridges 2010 (for the 2010 handpiece) on page 27.
- Range of cartridges 2210 (for the 2210 handpiece) on page 27.
- Range of cartridges 2045 (for the 2045 handpiece) on page 26.
- Range of cartridges 2245 (for the 2245 handpiece) on page 26.
The handpieces and cartridges 2210 and 2245 comply with the MIL-SPEC-2000 referring to the potential difference between the soldering tip and ground connection, must be less than 2 mV.
For a station to work properly, a control unit, a handpiece and one cartridge are needed.
Control Unit AD 2200 The station is supplied with:
- Control unit which incorporates a stand with
sponge and cartridge extractor.
- Connection cable to mains.
- Instructions manual.
- Transport packaging.
OPERATION
LED lights Red LED -ON- when lit, it indicates that the station is
plugged in the mains. Green LED -READY- when lit, it indicates that the
system is ready and correctly set for working. The green led light is on after a few seconds, is the
time needed to carry on the self-checking system. The green light is pulsing when the soldering iron is
in sleep mode.
RECOMMENDATIONS FOR USE
For soldering
- Clean the contacts and the printed circuit to be desoldered of dust or dirt.
- Preferably select a temperature below 350°C. Excess temperature may cause the printed circuit tracks to break loose.
- The tip must be well tinned for good heat conduction. If it has been inoperative for any length of time, it should be retinned.
Safety measures
- Incorrect use of this tool may cause fire.
- Be cautious when using the tool in places where inflamable products are stored.
- Heat can fire up inflamable products even when they are not at sight.
- Do not use when the atmosphere is explosive.
- Place the tool back on its stand in order to let it cool down before you store it.
ENGLISH
3
Sleep function
One of the Series Advanced features is that when the handpiece is placed in the holder, the temperature at the tip drops automatically to the sleep temperature. This function is only possible because of the quick response time which does not make the user realise the temperature rise to reach the selected temperature. Also by this, the oxidation of the tinning of the tip is considerably reduced and tip life is extended.
To indicate that the soldering iron is in sleep-mode, the green led starts pulsing. These parameters can be modified using the Console AC 2600 Ref. 2600000.
In order to take advantage of the above mentioned feature and as a security measure, it is necessary to place the handpiece on stand when the iron is not being used.
3 - Press the cartridge into the opening A, B or C:
A. For straight cartridges 2010 and 2210. B. For curved cartridges 2010 and 2210. C. For cartridges 2045 and 2245.
If the green led is not lit, the reason why, will be one of the following:
1. The handpiece or the cartridge are not plugged in.
2. The maximum available power has been exceeded for too long - e.g. in a very thick soldering at the high repetition rates.
3. The handpiece or cartridge has a short circuit or an open circuit.
4. Any other trouble preventing the system from working properly.
The green led goes off when the cartridge tip touches the extractor and the station stops the power supply.
The handpiece will reset itself automatically should the cartridge short circuit or go open circuit.
Should the handpiece be subject to:
- An electrical surge or the cartridge has not been
fitted correctly.
Please turn the unit off and switch on again to reset.
Only for users of AC 2600 console ref. 2600000. If you lock the working temperature thanks to the
console, the green LED -READY- will remain on while the dial is set at the locked temperature. If the dial is not set at the locked temperature, the green LED -READY- will be blinking. The farther the dial will be set from the locked temperature the slower the blinking pace will be.
Changing the handpiece's cartridge
With the Advanced system, the cartridge can be changed quickly, without turning off the station, so you have two soldering irons in one. Here is what to do to change the cartridge:
1 - Place the handpiece and remove the cartridge.
2 - Place the handpiece on top of the new cartridge,
press it slightly down and remove the handpiece.
4
ENGLISH
Console AC 2600
The console AC 2600 is designed for modifying the original regulation program parameters of the following Advanced control units:
- AD 2000 soldering station.
- AD 2200 soldering station.
- AD 4200 and AD 4300 dual soldering stations.
- AR 5500, AR 5800 (*) and DS 5300 (*) desoldering stations.
- AM 6000 and AM 6500 (*) rework stations. (*) These stations need a console whose
program version is 4.0 or higher.
Changes avalaible to perform:
- Fixing the the working temperature.
- Selection of temperature units in Celsius grades
-°C- or Fahrenheit -°F-.
- Modification of sleep temperatures and standby times.
- Adjustment of temperature.
- Set the parameters back to the original parameters.
- Read-out data: Working hours. Sleep cycles and sleep hours. Cartridge and iron changes. Program version.
JBC reserves the right to make technical changes without prior notification.
Temperature sealing-cover
0261410
Accessory which replaces the selection temperature button and it is use to prevent operators from changing the temperature that has been pre-selected. Indicates the selected temperature.
Alignment
XX
XXXXX
Important.
- It is essential to insert the cartridge till the end for a good connection. Take the mark a s reference.
Advanced series cartridge
Cartridge is made of the heating element which has the heating system, temperature sensor and long life tip.
Long-life tip is basically made of:
1 Copper 2 Iron 3 Chromium 4 Tin plate
Long-life tip care
Except for the copper core, the rest of metals are placed galvanically on layers relatively thin, so it is necessary to avoid the reasons which can cause its destruction.
To clean the tips, use the sponge included with the stand and check it is slightly moisted.
Only deionised water (car battery water) should be used in order to wet the sponge. If normal water was to be used, it is very likely that the tip will become dirty due to the salts dissolved within the water.
To re-tin the soldering tips, we recommend using the tip tinner/cleaner TT 9400 ref. 9400000.
Fume extractor accessories
Specially designed for the Advanced Series handpieces 2010/2210 and 2045/2245. Easily clips onto the handpiece and can be quickly removed for easy maintenance.
For handpieces 2045/2245: Standard Ref.0495000 +20mm longer Ref.0455002
For handpieces 2010/2210 Ref.0265000
AC 2600
Ref. 2600000
ESPAÑOL
5
Agradecemos la confianza depositada en JBC al adquirir esta estación. Ha sido fabricada con las más estrictas normas de calidad para prestarle el mejor servicio. Antes de poner en marcha el aparato, recomendamos leer con atención las instrucciones que a continuación se detallan.
Usted ha adquirido una Unidad de Control Advanced AD 2200. Para que la estación soldadora esté completa debe elegir el lápiz y los cartuchos adecuados al trabajo a realizar. La Unidad de control es válida sólo para los lápices 2010/2210 y 2045/2245 y sus respectivos cartuchos.
Unidad de Control AD 2200 230V Ref.2200200
Cartuchos
Extractor
Soporte
Conector lápiz
Lápiz 2045 Ref. 2045000 Lápiz 2245 Ref. 2245000
Lápiz 2010 Ref. 2010000 Lápiz 2210 Ref. 2210000
Conector equipotencial
ESPAÑOL
6
Datos técnicos
-Selección de la temperatura entre 100 to 371°C
(±5%).
- Potencia: 55W.
- Transformador de seguridad, separador de red
y doble aislamiento, con fusible integrado de protección de temperatura.
- Entrada: 230V 50Hz. Salida: 24V
Estructura del sistema de estaciones soldadoras Advanced
Para disponer de la máxima flexibilidad y adaptarse al trabajo a realizar, la serie Advanced, está dividida en tres módulos básicos, que se suministran por separado.
Unidad de control
- AD 2200 230V Ref. 2200200
Lápices soldadores
- 2010 Ref. 2010000
Potencia: 20W . Para trabajos de precisión, SMD, etc.
- 2210 Ref. 2210000
Potencia: 20W. Para trabajos de precisión, SMD, etc.
- 2045 Ref. 2045000
Potencia: 50W. Soldadura en electrónica general.
- 2245 Ref. 2245000
Potencia: 50W. Soldadura en electrónica general.
Existe una versión de los lápices 2045 y 2245 con mangos cubiertos de un aislante térmico.
- Lápiz 2045 termo-aislado ref. 2045110.
- Lápiz 2245 termo-aislado ref. 2245110.
Cartuchos
- Gama de cartuchos 2010 (para el lápiz 2010).
- Gama de cartuchos 2210 (para el lápiz 2210).
- Gama de cartuchos 2045 (para el lápiz 2045).
- Gama de cartuchos 2245 (para el lápiz 2245).
Vea la gama de cartuchos en las pag. 26 y 27. Los lápices y cartuchos 2210 y 2245 cumplen las
especificaciones MIL-SPEC-2000 en cuanto a diferencia de potencial entre la punta del soldador y la toma de tierra, que debe ser menor de 2 mV.
Para tener una estación operativa mínima se necesita una unidad de control, un lápiz y un cartucho.
Unidad de control AD 2200 Se suministra compuesta por:
- Unidad de control que incorpora soporte con
esponja y extractor de cartuchos.
- Cable de conexión a red.
- Manual de instrucciones.
- Envase de transporte.
RECOMENDACIONES DE USO
Para soldar
- Los componentes y el circuito deben estar limpios y desengrasados.
- Con preferencia seleccione una temperatura inferior a 350°C. El exceso de temperatura puede provocar el desprendimiento de las pistas del circuito impreso.
- La punta debe estar bien estañada para conducir bien el calor. Si permanece mucho tiempo en reposo, estáñela de nuevo.
Medidas de seguridad
- El uso incorrecto de la herramienta puede ser la causa de un incendio.
- Sea muy prudente cuando utilice la herramienta en lugares donde hay materiales inflamables.
- El calor puede producir la combustión de materiales inflamables incluso cuando no esten a la vista.
- No usar en la presencia de una atmósfera explosiva.
- Coloque la herramienta en su soporte después de usarla y dejela enfriar antes de almacenarla.
- Protección electrica clase I.
- Peso unidad completa: 2.6 Kgs.
- Caja antiestática.
Resistencia típica superficial: 105-1011 Ohms/ cuadro.
- Cumple la normativa CE sobre seguridad eléctrica,
compatibilidad electromagnética y protección antiestática.
- El borne equipotencial y la punta del soldador
están en conexión directa a la toma de tierra de red.
FUNCIONAMIENTO
Luces de señalización Luz roja -ON- encendida indica que la estación está
conectada a tensión de red. Luz verde -READY- encendida indica que el
sistema está dispuesto y en correctas condiciones de trabajo.
La luz verde se enciende después de unos pocos segundos, que es el tiempo necesario para que se realice el autochecking del sistema.
La luz verde parpadea cuando el soldador está en reposo.
ESPAÑOL
7
Soldador en reposo
Una de las cualidades de la serie Advanced, es que cuando el lápiz se coloca en el soporte, la temperatura baja automáticamente hasta la temperatura de reposo. Esto es posible, gracias a la rapidez de su respuesta térmica, que permite pasar de la temperatura de reposo a la de trabajo sin interrupción. Con lo cual se consigue una gran reducción en la oxidación del estañado y aumenta de una forma muy importante la duración de la punta. Para indicar que el soldador está en reposo, la luz verde de la unidad de control se pone a parpadear. Estos parámetros se pueden modificar con la
Consola AC 2600 Ref. 2600000. Para beneficiarse de la cualidad anterior y como medida de seguridad, es necesario colocar el lápiz en el soporte cuando no se utilice.
2 - Sitúe el lápiz sobre el cartucho a cambiar,
presione ligeramente y retírelo.
Cambio del cartucho del lápiz
El sistema Advanced permite el cambio rápido del cartucho, sin parar la estación, con lo que dispondrá de dos soldadores en uno. Para ello siga el proceso que se indica a continuación.
1 - Coloque el lápiz y extraiga el cartucho.
Si la luz verde está apagada, será debido a alguno de los siguientes motivos:
1. Que el lápiz con cartucho no está conectado.
2. Que se ha superado la potencia máxima disponible durante un tiempo excesivo, por ejemplo soldaduras muy gruesas y repetidas, etc.
3. Que el lápiz con cartucho está en cortocircuito o circuito abierto.
4. Cualquier otra anomalía que haga funcionar defectuosamente el sistema.
La luz verde se apaga y el soldador deja de ser alimentado mientras esté en contacto con el extractor de cartuchos. Esto sucede cuando el soldador lleva tres segundos en contacto con el extractor.
El reset de errores es automático cuando el lápiz o el cartucho están en cortocircuito o circuito abierto.
El reset de errores no es automático, se debe apagar y volver a conectar la estación, cuando:
- Existe un error de exceso de aporte de energía.
Sólo para usuarios de la cónsola AC 2600 ref.
2600000.
Si se fija la temperatura con la consola, el led verde READY sólo permanece encendido contínuamente cuando el dial señalice la temperatura fijada. Si el dial no está posicionado en la temperatura fijada, el led verde READY parpadeará a una velocidad más lenta cuanto más lejos de la temperatura fijada se encuentre.
3 - Presione a fondo el lápiz sobre el orificio A, B o C:
A. Para cartuchos 2010 y 2210 rectos. B. Para cartuchos 2010 y 2210 curvados. C. Para cartuchos 2045 y 2245.
Loading...
+ 21 hidden pages