QUAD CLOSE® TRAP SEAL
FUNCTION: The Quad Close Trap Seal forms a barrier to minimize the evaporation of the trap seal of a floor drain. The
Quad Close Trap Seal will open to allow drainage and close when there is no flow. It is for use in floor drain outlets or the adjustable strainer throats.
A DIA.
SCALE:DATE:
APPROVED BY:
CHECKED BY:
RN CL JM G5-20-08 NONE s2692
B
WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA
A IAPMO ASSE GPM FLOW FIG. NO. (Pipe Size) B LISTED j LISTED j RATE l
2692-0150 01.5(38) 2.09(53) — 6.0 (22.7 L/M) 2692-02 02(50) 2.66(68) FILE # 7479 REC.#1435 12.0 AF-GW n (45.4 L/M) 2692-03 03(75) 2.66(68) FILE # 7479 REC.#1435 34.0 AF-GW n (128.7 L/M) 2692-0350 0350(89) 2.66(68) FILE # 7479 REC.#1435 51.0 k k AF-GW n (193.06 L/M) 2692-04 04(100) 2.66(68) FILE # 7479 REC.#1435 73.0 AF-GW n (276.4 L/M) 2692-06 06(150) 3.66(93) — 215.0 (814.0 L/M)
INSTALLATION: The 01.5(38), 02(50), 03(75), 04(100) & 06(150) Quad Close Trap Seal sizes install in the drain outlet. To install, simply insert the Quad Close Trap Seal in the drain outlet or k throat of strainer until the top of it is flush with top of drain outlet or strainer throat. See reverse side of submittal for illustration.
DRAWN BY:

2692

DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE
FIGURE
NUMBER
NOTES:
j Tested by The IAPMO R&T Product Certification Agency to ASSE Standard #1072, Barrier Type Floor Drain Trap Seal Protection Devices. All sections of the Standard was successfully passed. k The 0350 (89) Quad Close Trap seal size installs in the throat of Smith adjustable strainers. See reverse side of submittal for illustration. l Required flow rates per ASSE Standard #1072, Section I. All sizes meets or exceeds these flow rates. m Do not use in applications where the room/space has an atmospheric pressure less than the ambient pressure of the exterior of the room/space or building.
n AF-GW represents floor designation/rated for all floor types per ASSE 1072, Section II. o Copies of the listing certificates and/or ASSE 1072 Test Report available upon request.
H 8-26-14 Revised Table TBW JM G 7-30-14 Added L/M TBW JM F 5-22-14 Revised Table, Notes TBW JM E 11-6-12 Removedp TBW CL
REV.
DATE DESCRIPTION BY CKD. BY
WEIGHT POUNDS
VOLUME CUBIC FEET
NOTE: Dimensions shown in parentheses are in millimeters.
Patent No. 8,844,572
2692
SMITH
CUSTOMER
DRIVEN
SINCE 1926
DRAWING NUMBER
A
SIZE
SCALE:DATE:
®
JAY R.
SMITH
MEMBER OF MORRIS GROUP INTERNATIONAL
POST OFFICE BOX 3237 MONTGOMERY, ALABAMA 36109-0237 (USA) TEL: 334-277-8520 FAX: 334-272-7396
MFG. CO.
QUAD CLOSE® TRAP SEAL
®
www.jrsmith.com
ASPE
®
MEMBER OF:
A
T
I
R
N
Y
A
S
®
E
N
G
P
G
r
N
e
e
I
I
r
v
N
R
u
e
E
E
n
C
t
i
n
o
a
n
h
R
T
a
r
t
e
h

Installation Illustrations

LOCATION
WE CAN ASSUME NO RESPONSIBILITY FOR USE OF SUPERSEDED OR VOID DATA
APPROVED BY:
CHECKED BY:
RN CL JM E5-20-08 NONE s2692 BS
DRAWN BY:
INSTALLATION NOTES:
1. First clean the drain and pipe of any debris that could cause an odor or interfere with the Quad Close sealing properly.
2. Insert the Quad Close into the drain outlet, drain pipe or throat of adjustable strainer by pushing until it is flush with top of drain outlet, drain pipe or throat of adjustable strainer.
3. Once in place, open the Quad Close to relieve any back pressure between it and the p-trap water seal. (Note: Installing the Quad Close in the closed position will force water out of the p-trap.)
4. To ensure the p-trap water seal is fully
2692 BS
DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCE AND CHANGE WITHOUT NOTICE
E 3-30-15 Added Installation Notes TBW CL D 8-26-14 Revised Installation TBW JM C 4-24-12 Rev. Title, Installation TBW CL B 4-2-12 Added Note TBW DP
NUMBER
REV.
FIGURE
Installation in Drain
Body Outlet
0150(38), 02(50), 03(75), 04(100) & 06(150) Sizes
primed pour water slowly down the drain until the water level no longer rises below the drain.
DATE DESCRIPTION BY CKD. BY
WEIGHT POUNDS
Installation in Strainer
Throat k
0350(89) Size
VOLUME CUBIC FEET
2692 BS
Loading...