5
Installation Instructions
This appliance should only be installed by a trained and NZHHA qualified installer.
Warning: the appliance and flue system shall be installed in accordance with AS/NZS 2918 and the appropriate requirements of
relevant building code/codes.
Warning: appliances installed in accordance with this standard shall comply with the requirements of AS/NZS 4013 where re-
quired by the regulatory authority, i.e. the appliance shall be identifiable by a compliance plate with the marking “Tested to AS/
NZS 4013”.
Any modification of the appliance that has not been approved in writing by the testing authority is considered to be in breach of
the approval granted for compliance with AS/NZS 4013.
Caution: mixing of appliance or flue system components from different sources or modifying the dimensional specification of
components may result in hazardous conditions. Where such action is considered, the manufacturer should be consulted in the
first instance.
Caution: cracked and broken components e.g. glass panels or ceramic tiles, may render the installation unsafe.
Warning: do not connect to an unvented hot water system.
Install in accordance with AS 3500.4.1 or NZS 4603 and the appropriate requirements of the relevant
building code/codes.
Maintain a clearance of at least 1 metre between front of the appliance and building structure or
any other substantial immovable object.
If the appliance is installed on a heat sensitive floor, the floor should be protected with an insula-
tion floor protector, which shall extend entirely beneath the heater. For the correct floor protector
extension, refer to dimensions Q & R in FIG 1 & 2.
Your appliance shall be seismically restrained, including the floor protector using the provided
holes or brackets. The restraints should be sufficient enough to resist a seismic loading equal to
0.4 times the mass of the appliance. We recommend a minimum of 8mm Dynabolts on concrete
floors and 8mm coach screws for wooden floors of appropriate length.
Minimum Material Specifications
For Floor Protectors on a Floor
of Combustible Material
MODEL SPECIFICATION
IS500 8mm ceramic tiles *
* The IS500 is also approved
with 1mm sheet steel with a
10mm spacing above combustible material. For use when extending hearths.