Jaxx ICRY1066 Other

REPORT NUMBER: SHAT06015123
TEST REPORT
Number : SHAT06015123
Applicant : MORGAN SHANGHAI LTD.,CORP Date : Apr 30, 2019 SHANGHAI CITY, XUHUI DISTRICT BAOQING
ROAD NO. 21 BUILDING NO. 18 BAOQING BUILDING 9 FLOOR
Attn : SASA LUO
Sample Description As Declared :
No. Of Sample : One (1) Fibre Content : ­Material : Upholstery Fabrics Finishing : ­End Uses : ­Colour : Silver Style No. : Silver Fox Order No./PO No. : ­Buyer’s Name : ­Manufacturer’s Name : ­Ref. : -
Applicant’s Provided Care Instruction/Label : -
Date Received/Date Test Started : Apr. 25, 2019
Prepared And Checked By: For Intertek Testing Services Ltd.,Shanghai
Jennifer Ren General Manager
Page 1 Of 5
Intertek Testing Services Ltd., Shanghai
2/F, Building No.4, Shanghai Comalong Technology Service Park,
中国上海宜山路 889号上海齐来科技服务园区 4 号楼 2 邮编:200233
Tel: +86 21 5339 5999 Fax: +86 21 5426 2030 E-mail: textile.shanghai@intertek.com Website:Intertek.com
889 Yishan Road, Shanghai 200233, China
上海天祥质量技术服务有限公司
Attention is drawn to the terms and conditions printed overleaf
TEST REPORT
Number : SHAT06015123
Tests Conducted (As Requested By The Applicant)
1 Color Fastness To Crocking (AATCC 8-2016):
Dry 4.5 Wet 4.5
2 Color Fastness To Light (AATCC 16.3-2014, Option 3, Xenon-Arc Lamp):
20 AATCC Fading Unit (AFU) Exposure Grade 4.5
3 Color Fastness To Light (AATCC 16.3-2014, Option 3, Xenon-Arc Lamp):
40 AATCC Fading Unit (AFU) Exposure Grade 4.5
4 Tensile Strength As Received (ASTM D5034-09(2017), 1-in Grab Test, Tensile Testing Machine, CRE):
Warp 92.1 lbf Weft 128.5 lbf
5 Elongation Test As Received (Ref. To P21 Of "Joint Industry Fabric Standards And Guidelines"):
Warp 6.6% Weft 29.3%
Remark: Elongation Test At 10 Lbs.
1
6 Tearing Strength As Received (ASTM D2261-13 (R2017)
, Single Rip Tongue Tear, Tensile Testing Machine,
CRE):
Across Warp 17.8 lbf Across Weft 11.6 lbf
Page 2 Of 5
Intertek Testing Services Ltd., Shanghai
2/F, Building No.4, Shanghai Comalong Technology Service Park,
中国上海宜山路 889号上海齐来科技服务园区 4 号楼 2 邮编:200233
Tel: +86 21 5339 5999 Fax: +86 21 5426 2030 E-mail: textile.shanghai@intertek.com Website:Intertek.com
889 Yishan Road, Shanghai 200233, China
上海天祥质量技术服务有限公司
Attention is drawn to the terms and conditions printed overleaf
TEST REPORT
Number : SHAT06015123
Tests Conducted (As Requested By The Applicant)
7 Seam Slippage As Received (ASTM D4034-1995, Tensile Testing Machine, CRE):
S.O. ¼” // To Warp * // To Weft *
Strength // To Warp 117.7 lbf(FR) // To Weft 90.9 lbf(FR)
Remark : S.O. ¼” = Seam opened at ¼ inch
FR = Fabric ruptured * = The seam opening was less than ¼ inch though the ultimate Seam strength was found as
stated.
8 Pilling Resistance As Received (ASTM D3512/D3512M-10 (2014), Random Tumbler):
After A 60-Minute Test Rating 4.0
9 Abrasion Resistance (ASTM D4157-2013, Oscillatory Cylinder Method, Cotton Duck #10 Abradant With 3 lbs
Pressure Load And 4 lbs Tension Load):
Resistance Warp Over 100000 Cycles Weft Over 100000 Cycles
Remark: End Point Is 100,000 Cycles.
Page 3 Of 5
Intertek Testing Services Ltd., Shanghai
2/F, Building No.4, Shanghai Comalong Technology Service Park,
中国上海宜山路 889号上海齐来科技服务园区 4 号楼 2 邮编:200233
Tel: +86 21 5339 5999 Fax: +86 21 5426 2030 E-mail: textile.shanghai@intertek.com Website:Intertek.com
889 Yishan Road, Shanghai 200233, China
上海天祥质量技术服务有限公司
Attention is drawn to the terms and conditions printed overleaf
TEST REPORT
Number : SHAT06015123
Tests Conducted (As Requested By The Applicant)
10 Flammability Test (California Technical Bulletin 117-2013 Section 1: Cover Fabric Test):
Test Method
The apparatus and method of testing were those described in California Technical Bulletin 117-2013, Section 1, for measuring the tendency of upholstery cover fabrics to smolder and contribute to fire propagation, when subjected to a smoldering ignition source.
Pass/Fail Criteria
A cover fabric material is considered pass or fail based on following criteria:
1. A single mock-up test specimen fails to meet the requirements of this test procedure if any of the following criteria occurs: a) The mock-up test specimen continues to smolder after the 45 minutes test duration. b) A vertical char length (measured as specified in step 11.9 of ASTM E1353-08a
ε1
) of more than 1.8 inches
(45 mm) develops on the cover fabric.
c) The mock-up test specimen transitions to open flaming.
2. The cover fabric passes the test if three initial mock-up specimens pass the test, i.e., the cigarettes burn their full length and the mock-ups are no longer smoldering.
3. If more than one initial specimen fails, the cover fabric fails the test.
4. If any one of the three initial specimens fails, repeat the test on additional three specimens.
5. If all three additional specimens pass the test, the cover fabric passes the test. If any one of the additional three specimens fails, the cover fabric fails the test.
Test Result
Initial Test
Vertical Char length
(Inches)
Mock-up specimen continues to smolder After 45 Minutes
Mock-up test
specimen
transitions to open
flaming
Test Result
Specimen 1 0.5 No No Pass Specimen 2 0.5 No No Pass Specimen 3 0.5 No No Pass
Conditioning : At least 24 hours in an atmosphere having a temperature of 21° ± 3 °C (70° ± 5 °F) and less
than 55% relative humidity
Remark : No = Was not observed
Page 4 Of 5
Intertek Testing Services Ltd., Shanghai
2/F, Building No.4, Shanghai Comalong Technology Service Park,
中国上海宜山路 889号上海齐来科技服务园区 4 号楼 2 邮编:200233
Tel: +86 21 5339 5999 Fax: +86 21 5426 2030 E-mail: textile.shanghai@intertek.com Website:Intertek.com
889 Yishan Road, Shanghai 200233, China
上海天祥质量技术服务有限公司
Attention is drawn to the terms and conditions printed overleaf
TEST REPORT
Number : SHAT06015123
Tests Conducted (As Requested By The Applicant)
11 Flammability Test (NFPA 260-2013 Cover Fabric Classification):
Criteria : Class I : A Specimen Shall Shown No Evidence Of Ignition Of Any Test Assembly. The Vertical Char On Any Of The Three Specimens Shall Not Exceed 45 mm. Class II : Cover Fabric That Do Not Meet Class I Criteria Shall Be Designated As Class II.
Specimen Number Vertical Char (mm) Evidence Of Ignition
1. 14 No
2. 16 No
3. 15 No
Classification = Class I
End of Report
This report is made sole ly on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.
This report shall not be reproduced except in full, without written approval of the laboratory.
Page 5 Of 5
Intertek Testing Services Ltd., Shanghai
2/F, Building No.4, Shanghai Comalong Technology Service Park,
中国上海宜山路 889号上海齐来科技服务园区 4 号楼 2 邮编:200233
Tel: +86 21 5339 5999 Fax: +86 21 5426 2030 E-mail: textile.shanghai@intertek.com Website:Intertek.com
889 Yishan Road, Shanghai 200233, China
上海天祥质量技术服务有限公司
Attention is drawn to the terms and conditions printed overleaf