Jawon Medical FT 700 User Manual

1. INTRODUCTION 3
2. WORD DEFINITIONS 3
3. CLASSIFICATION AND COMPLIANCE 4
4. SAFETY PRECAUTIONS 4
5. SAFETY SYMBOLS 6
1. FRONT PART 7
2. PRINTER 9
3. REAR PART 10
4. ACCESSORIES 12
5. OPTIONS 12
1. CONNECTING POWER CABLE(AC INPUT) 13
2. ASSEMBLING OF ARM SUPPORTER 13
3. LOADING THE PRINT PAPER 14
4. CONNECTING PORTS(RS-232C) 14
5. SETTING TIME AND DATE 15
1. CAUTIONS FOR MEASUREMENT 16
2. MEASUREMENT 17
3. DATA ON MEASUREMENT BY PRINTER 20 21
1. AFTER SERVICE 24
2. PACKING AND TRANSPORT 24 25 26
We highly appreciate you choose this JAWON product. You are kindly requested to be familiar with these directions before using this product and always keep it together with the product. In case you are not clear about any directions or problems arising while using the product, please contact our service center. We will provide you with detailed instructions.
1. INTRODUCTION
FT-700 (R/L) is a state-of-the-art medical equipment that can check not only blood pressure and the pulse rate but also Pressure Rate Product (PRP - an important index for the oxygen consumption of cardiac muscle) through a single process. This machine will help to provide upgraded medical services for the patients since more accurate and reliable diagnosis is collected and suitable treatments can be arranged on the basis of these measured results. FT-700 (R/L) is the fully automated blood pressure monitor armed with the belt-type cuff that facilitates the test time quicker and provides the results more reliable.
2. WORD DEFINITIONS
To ensure safe operation and long term performance stability, it is essential that you fully understand the functions, operating and maintenance instructions by reading this manual before operating your unit. Particular attention must be paid to all warnings, cautions and notes incorporated herein. The following conventions are used throughout the manual to denote information of special emphasis.
WARNING
Important information to indicate the presence of a hazard which can cause severe personal injury, death of substantial property damage if the warning is ignored.
CAUTION
Important information to indicate the presence of a hazard which will or can cause minor personal injury or property damage if the warning is ignored.
NOTE
Important information to notify the user of installation, operation, or maintenance information which is important but not hazard-related. Hazard warning should never be included under the note signal word.
3. CLASSIFICATION AND COMPLIANCE
1) FT -700(R/L) is classified as ;
- Class 1 type-BF against electric shock
- Ordinary equipment without protection against ingress of water
- Equipment not suitable for use in presence of a flammable anesthetic mixture by standard of IEC 60601-1(Safety of Medical Electrical Equipment)
2) FT -700(R/L) are complied with Class A for Noise-Emission, Level B for Noise-immunity, by standard of IEC 60601-1-2(Electromagnetic Compatibility Requirements).
3) This blood pressure meter complies with the EN 1060-1 : 1995 Non-invasive Sphygmomanometers general requirements as well as EN 1060-3 : 1997 supplementary requirements for electro-mechanical blood pressure measuring systems.
4. SAFETY PRECAUTIONS
FT-700(R/L) is designed and manufactured with consideration given to the safety of the operator and subject and also to the reliability of the unit. The following precautions must be observed for additional safety;
1) The unit must be operated only by, or under supervision of, a qualified person by JAWON
or his distributor.
2) FT series are specified as Class 1 type BF unit under the standard of IEC 60601-1(Safety
of Medical Electrical Equipment). Therefore, patients must not touch or handle inner side of the system at any time.
3) Do not modify the unit. If any modification is desired, ask JAWON or its authorized dealer
for service.
4) The unit has been factory-adjusted for optimum performance.
Do not attempt to adjust any or switches except those specified in this manual for operation.
5) If you have experienced any trouble with the unit, switch it off immediately, and contact
JAWON or its authorized dealer for assistance.
6) If you plan to connect any device of other manufacturers electrically or mechanically to
this unit, contact JAWON or its authorized dealer for instructions before doing so. When you connect computer or other system to the unit(RS-232C), the attached systems should be certified by IEC 950 or equivalent standards for data processing equipment. Configurations shall comply with the system standard IEC60601-1-1. Everybody who connects additional equipment to the signal input part or signal output part configures a medical system standard IEC 60601-1-1. If in doubt, consult the A/S department of local distributor.
7) Avoid the following environments for storage ;
- Where the ambient temperature falls -5
or exceeds 50 .
- Where the atmospheric pressure falls below 70 kPa(700 mbar) or exceeds 106 kPa
(1060 mbar).
- Where the humidity is over 85% non-condensing.
- Where the unit is exposed to spray or splashing water.
- Where the unit is exposed to dust
- Where the unit is exposed to water vapor.
- Where the unit is exposed to high density oil vapor.
- Where the unit is exposed to salty atmosphere.
- Where the unit is exposed to explosive gas.
- Where the unit is exposed to excessive shocks or vibrations.
- Where the angle of inclination of mounting surface exceeds 10 degrees.
- Where the AC power line voltage heavily fluctuates
- Where the AC power line voltage changes heavily when this unit is in operation.
- Where the unit is exposed to direct sunlight.
Note
Incorrect operation or failure of user to maintain the unit relieves the manufacturer or his agent of the system's non-compliance with specifications or responsibility for any damage or injury. This manual is made for informational purpose and this manual and product are not meant to be a substitute for the advice provided by your own physcian or other medical problem. You should not use this information contained product for diagnosis or treatment of health problem or prescription of medication by yourself. If you have or suspect that you have a madical problem, consult your physician promptly. Defective unit or accessories, must be packed in the replacement cartons, are shipped off from you to JAWON MEDICAL CO.,LTD. Shipping and insurance costs for return of defective unit must be prepaid by you.
Caution
Measurements may be impaired if this device is used near televisions, microwave ovens, X-ray equipment or other devices with strong electrical fields. To prevent such interference, use the meter at a sufficient distance from such devices or turn them off.
5. SAFETY SYMBOLS
The International Electrotechnical Commission(IEC) has established a set of symbols for medical electrical equipment which classifies a connection or warnning of any potential hazard. The classifications and symbols are shown below. Save these instructions for your safety.
The following symbols are used inside the system :
Isolated patient connection (IEC 60601-1-Type BF)
This symbol identifies a safety note. Ensure you understand the function of this control before using it. Control function is described in operation manual.
I and O on power switch represent ON and OFF, respectively.
Identifies equipotential ground(located next to ground stud on rear panel) (IEC 417-5021).
Identifies the point where the safety ground of the system is fastened to the chassis.
Do not open. This is for factory only.
CAL
1. FRONT PART
START BUTTON Press START button after ready to measure, the cuff will be wrapped automatically and begins to pressurize. STOP BUTTON Press STOP button if you want to stop it during measurement. Pressurizing will stop and the air will exhaust from the cuff. LCD DISPLAY It displays letters and animations during test processes, along with the results (systolic, diastolic, pulse, PRP) upon finishing examination. CLOCK SECTION (Date and Time) On the right upper corner of the LCD screen, date and time are displayed. PRINTER COVER It protects the printer. AUTOMATIC CUTTER(printer paper let-out slot) Printing paper is automatically cut off to let it out through the slot. CUFF It wraps and releases the arm automatically for measurement. ARM REST When the arm is placed on the cuff, the arm supporter sustains the arm and makes the right position. HUMAN SENSOR When a user approaches, power is automatically turned on and vice versa. CARD-READER When card is inserted, it reads information in it and stores the measured results. EMERGENCY STOP BUTTON When your arm is oppressed due to high pressurizing or irregular operation is done, press this button then the cuff will be exhausted rapidly.
Note
The cuff and the buttons(START and STOP button) of FT-700 are located at reverse side by R and L type.
FRONT PART
ARM REST
CUFF
PAPER OUTPUT
PRINTER COVER
TIMER
DISPLAY
START BUTTON STOP BUTTON
HUMAN SENSOR CARD-READER EMERGENCY
STOP BUTTON
Note
Printer, card reader and human sensor are optional. ID buttons are only attached to FT-750AF (R/L) model. ID card can be issued either by the machine manager or by the manufacturer of the model. The card can store ID number and measured results. The card stores two previous measured results and can contain three measured results with the current one altogether. When the model manager writes the card, please refer to the manual and specifications for operation and programs attached to the card writing device at the time of purchase.
2. PRINTER
PRINT button
- Use it when you print out the data.
- If you set
ON at the rear (PRINT ON/OFF switch), the data is printed automatically
even you do not press PRINT button.
- Normally, when you press this button, all measured data after you turn the power on will be printed.(if you turn it off, all memorized data would be deleted.)
- When you set the date and time, the number goes up by pressing this one.
FEED button
- Use this button for setting the paper
- When you set the date and time, the number goes down by pressing this one.
SET button
- set the date and time
- The functions are as follows when press this before or after measurement.
(It does not work during measurement)
- Sequence is HOUR
MIN. MON. DAY YEAR
- Within 5seconds, finish set of the date and time.
- See the page ‘15’ for detailed method