WARNING ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···········∙∙∙·∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙…………········· 3
ABOUT BLOOD PRESSURE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙··············∙∙∙·∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙…………······∙∙∙··· 4
1. What is blood pressure? ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙………·········∙∙∙∙∙∙∙∙∙∙∙………………∙∙∙∙∙ 4
2. What makes my blood pressure change? ∙∙∙∙∙∙∙∙∙∙∙∙∙∙··········∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙·····∙∙∙∙∙∙…………………∙·· 4
3. Classification of the blood pressure? ∙∙∙∙······∙∙···∙∙∙∙∙∙∙∙∙·······∙∙………………∙∙…∙……………∙∙…·4
4. Why do I have to check blood pressure at home? ∙∙∙∙∙∙·∙··················………………………
5
5. What is benefit of ECHO-H the data transmissible blood pressure monitor use?……… 6
6. What is the benefit of ECHO-H date and time recorded monitor use? ……………………6
7. What is the benefit of ECHO-H data transmissible wrist blood pressure monitor use?…6
INTRODUCTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙·················∙∙∙·················…………··…… 7
WORD DEFINITION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·····························∙∙∙∙∙∙∙······∙∙∙∙∙∙∙∙∙∙∙∙
··············…………·····…… 8
NOTE TO USER ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·············∙∙∙∙∙∙∙∙∙∙∙∙∙∙······················∙∙∙∙····················…………··…… 9
CLASSIFICATION & COMPLIANCE WITH STANDARD ∙∙∙∙∙∙∙∙∙∙·················∙∙······…………····· 9
SAFETY PRECAUTIONS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙………·····… 10
SAFETY SYMBOLS ∙∙∙∙······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙·…………····…·…… 11
PART NAMES & FUNCTIONS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙················∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙…………∙∙∙∙·……12
1. Main unit and accessories∙∙∙∙∙∙∙∙∙∙∙∙∙∙··················∙∙∙∙∙∙∙······················……………………… 12
2. Symbols in LCD indicator ∙∙∙∙∙∙∙∙∙∙∙∙∙∙······∙∙∙∙∙∙∙∙∙∙∙∙∙∙····························…………······……… 13
PRECAUTIONS FOR MEASUREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙········∙∙∙∙∙∙∙∙∙∙·····················…………·······……14
BATTERY INSERTION/REPLACEMENT········∙································…………······………… 16
1. How to insert the batteries ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·············∙∙∙∙∙∙·······························………··…·…… 16
2. Replacement of the batteries ∙∙∙∙∙∙∙∙∙∙∙∙∙∙··················∙∙∙∙∙∙∙∙∙∙∙···················………··……·… 16
SETTING THE DATE AND TIME ∙∙∙∙∙∙∙∙∙∙∙∙∙∙················∙∙∙∙······························…………·····…17
1. Entering the mode to set date and time ·············∙∙∙∙∙∙∙∙∙∙∙∙∙∙·················∙∙∙∙∙∙∙∙……∙…∙…… 17
2. Setting up ∙∙∙∙∙∙∙∙∙∙∙∙∙∙
·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙·∙················∙∙∙∙∙∙∙∙……∙…………17
SOUND ON/OFF ∙∙∙∙∙∙∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙·∙·····················∙∙∙∙∙∙………………………………………19
SET INFLATION LEVEL……………………………………………………………………………… 19
DATA TRANSMISSION·············∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙·∙·····················∙∙∙∙∙∙∙…………∙……………20
MEASUREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙···········∙∙∙∙∙∙∙∙∙∙∙∙∙∙······················∙∙∙∙∙∙····················……………·……22
1. Wrapping the cuff ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙········…∙∙∙∙∙∙∙∙∙∙···········………·…………22
1. Against errors ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·······················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙·∙·········∙∙∙∙∙∙∙……………………
∙ 29
2. Against trouble ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·····················∙∙∙∙∙∙∙∙∙∙∙∙∙∙···∙∙∙∙∙∙∙∙∙∙∙∙∙·∙···············∙∙∙∙∙…………∙………30
WARRANTY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙·················∙∙∙∙∙··············∙∙······································………………… 31
SPECIFICATION ∙∙∙∙∙∙∙∙∙∙∙∙∙············∙∙∙∙∙∙∙∙∙∙∙∙∙∙················∙∙∙∙∙∙∙∙·························…………··…… 33
1
WARNING
We highly appreciate you choose this JAWON product.
Those who will use this blood pressure monitor are strongly advised to read this
manual thoroughly and understand all instructions and warnings before using it.
Information in this manual is made for informational purpose and this manual and
product are not meant to be a substitute for the advice provided by your own
physician or other medical professional.
You should not use this information contained in this manual or this equipment for
diagnosis or treatment of health problem or prescription of medication.
If you have or suspect that you have a medical problem, consult your physician
promptly.
2
ABOUT BLOOD PRESSURE
1. What is blood pressure?
Blood pressure refers to the force or pressure exerted on the artery vessel
when blood flows through them. In order to allow the blood to supply nutrition
and oxygen to every organ and corner of the body, a certain level of pressure
is necessary and it comes from the each time the heart beats or contracts.
The heart activity is broken down into two phases called Systole and Diastole.
Systolic is the pressure to send blood out into the body and Diastolic is the
pressure creating as the heart pulls blood back through it.
Blood pressure is recorded as systolic over diastolic, as shown below.
115/75
systole occurs diastole occurs
during the contraction during the relaxation
and empting of the heart and filling of the heart
2. What makes my blood pressure fluctuate?
Blood pressure changes in response to many factors.
These factors include changing in the temperature and humidity, physical
exercise, restlessness due to stress, fear, anxiety, anger, food and an
individual’s physical condition.
3. Classification of the blood pressure
: National High Blood Pressure Education Program, National Heart, Lung and
3
Blood Institute, NIH (JNC7)
Diastolic
(㎜Hg)
100
Stage 2 Hypertension
90
80
120 140 160 Systolic(㎜Hg)
Prehypertension
Normal
Stage 1 Hypertension
Blood pressure constantly fluctuates during of a day, so that monitoring
Note
should be done at least three times and determined. Occasional high or
low readings do not mean your monitor is malfunctioning or you are ill.
The important thing is that you have information to talk with your doctor
about normal and abnormal results corresponding your circadian rhythm.
4. Why do I have to check blood pressure at home?
Home monitoring may help alleviate the medical phenomena ‘White Coat
Hypertension’ which causes a sensitive individual blood pressure to be higher
when taken in a medical office setting. The elevation of it may be due to
several factors, including stress, nervousness, or increased sympathetic
activity associated with the clinical environment. It may cause your blood
pressure to rise about 20 to 30mmHg higher than usual. When monitoring at
home, you may get a truer indication of your blood pressure in a usual,
relaxed state. Regular home monitoring provides you a valuable over time
readings to give to your physician to diagnose and optimize the treatment
program corresponding your circadian rhythm of blood pressure. It also
provides you the information when your blood pressure falls or rises to enable
to manage your health. Therefore, it is important to take regular daily home
monitoring and keep clear records.
4
5. What is benefit of ECHO-H User-set inflation level monitor use?
ECHO-H allows that user can set up the inflation level corresponding the blood
pressure of user-self. This function is ideal for the hypertensive while other
kinds of pressurization method are more suitable to the person who is able to
estimate own blood pressure or under treatment. For a correct monitoring, the
pressurization need 30㎜Hg higher than your estimated blood pressure.
Therefore the hypertensive may have frequently experienced re-pressurization
during monitoring with the monitor employed those methods. In case of
excessive hypertension or a feeble pulse, it is possible to experience it over 2
times a monitoring. That will affect your emotion, blood vessel and eventually
monitoring results.
ECHO-H, the monitor of user-set inflation excludes the necessity of repressurization during monitoring of the hypertensive and makes it convenient
and correct with the single pressurization trial.
6. What is the benefit of date and time recorded wrist monitor use?
There is no need to remember monitoring date and time if the device
automatically records them. As ECHO-H is built-in calendar and clock that
inconvenience is not any more.
These are more helpful to the device having big memory capacity.
7. What is the benefit of ECHO-H data transmissible wrist blood pressure monitor
use?
Without going to hospital, you can have physician’s advice with data
transmissible blood pressure monitor.
ECHO-H is a Home to Hospital bi-directional networking blood pressure
monitor that you can transmit saved data from the device to your personal
computer through interface then send your physician them. Your physician will
read those to find health problems and give proper advice you through
computer network. With the support of the analyzing program, ECHO-H tracks
your blood pressure changes sophisticatedly and enables you to realize the
characteristics of yours and control it.
ECHO-H is a time and cost saving
healthcare networking watch-type instrument.
5
INTRODUCTION
Thank you for purchasing the ECHO-H.
Intended use
This home blood pressure monitoring device is indicated for use in the noninvasive
measurement of systolic and diastolic blood pressure and heart rate in adult age
18 and over, in a home care environment. This model is designed to enable a
person who suspects some trouble with blood pressure to check it at home.
User-set inflation and Oscillometric method
Your unit employs a user-set inflation and an oscillometric method. The user can
decide its inflation level corresponding the characteristics of the user’s blood
pressure. Oscillometric for measurement of blood pressure and heart rate, which
refers to check blood pressure by measuring oscillation in the cuff while the artery
of the arm oscillate reflecting contracts and relaxes every heart beat.
Data transmissible and analyzing software
This device is data transmissible. You can transmit readings saved memory of the
device to your personal computer then mailing to your physician and get advice
about it from her/him at home. ECHO-H is a time saving device partially replacing
a necessity your visit to your physician. Additionally the data transmitted to your
PC can be analyzed and tracked sophisticatedly with analyzing program optionally
offered by manufacturer.
Voice massage
Makes you monitor blood pressure easily and know the result clearly without third
person’s help especially for the elderly.
Noise detecting
As ECHO-H is contrived to detect moving or noising during measurement and
display it both on the real time and recalled reading on LCD, you and your
physician can determine if the readings are reliable.
Memory feature
It has 64 reading memory capacity recorded monitoring date and time supporting
built-in calendar and clock which are input them automatically to each reading.
Accuracy
Blood pressure measurements determined with this device are equivalent to those
obtained by a trained observer using the cuff/stethoscope auscultation method,
within the limits prescribed by the American National Standard, Electronic or
6
Automated Sphygmomanometers.
WORD DEFINITION
To ensure safe operation and durable performance stability, it is essential that you
fully understand the functions, operation and maintenance instructions by reading
this manual carefully before using the unit.
Particular attention must be paid to all warnings, cautions and notes incorporated
herein. The following conventions are used throughout the manual to denote
information of special emphasis.
Important information to indicate the presence of a hazard in which may arise
severe personal injury, death of substantial property damage if the warning is
ignored.
CAUTION
Important information to notify the user of operation or maintenance
information in which is important but not hazard-related. Hazard warning
NOTE
should never be included under the note signal word.
※ Property damage refers to a wide range of damage involving your house,
household goods, domestic animals, and pets etc..
7
NOTE TO USER
• For all damages or injuries caused by user’s incorrect operation or failure in
maintenance the unit relieves, the manufacturer and its agent of the system do
not have any responsibility and non-compliance with specifications.
• Please keep this manual together with the appliance since it is compiled to
provide the maximal convenience to those who use this device.
• Defective unit or accessories that is shipped off from customer to Jawon
medical Co. or its authorized dealer for service must be packed in the safe way
and the replacement carton. Shipping and insurance cost for returning of
defective unit must be prepaid by customer.
8
CLASSIFICATION & COMPLIANCE WITH STANDARD
Classification and Compliance with Standards Model ECHO-H manufactured by
Jawon medical is classified as ;
- ECHO-H is specified as Class 2 type BF unit under the standard of
IEC60601-1 (Safety of Medical Electrical Equipment).
- Ordinary equipment without protection against ingress of water
- Equipment not suitable for use in presence of a flammable anesthetic
mixture by standard of IEC60601-1 (Safety of Medical Electrical Equipment)
- Equipment that complies with Class B for Noise-Emission, Level B for
Noise-immunity by standard of IEC60601-1-2 (Electromagnetic
Compatibility Requirements)
This blood pressure meter complies with the EN1060-1 : 1995 Non-invasive
Sphygmomanometers general requirements as well as EN1060-3 : 1997
supplementary requirements for electro-mechanical blood pressure
measuring system.
9
10
SAFETY PRECAUTIONS
ECHO-H are designed and manufactured in deep consideration for users’ and
operators’ safety and completing reliability of the unit based International
Standards for medical equipment.
The following precautions must be observed for additional safety ;
1. User must not touch or handle the inner side the system at anytime. It may
cause an electrical shock and flame out.
2. The unit has been factory-adjusted for optimum performance. Do not attempt
to modify or adjust any preset controls or switches except those specified in
this manual for operation. If any modification is desired, ask manufacturer or its
authorized dealer for service.
3. If you have any trouble with the unit, switch it off immediately, and contact
manufacturer or its authorized dealer for assistance.
4. Avoid the following environments for storage and operation
- where the ambient temperature deviates -20℃ ~ 60℃ for storage
- where the ambient temperature deviates 10℃ ~ 40℃ for operation
- where the atmospheric pressure deviates
70kPa(700mbar)~106kPa(1060mbar)
- where the humidity is above 95% for storage and below 30% or above 75%
for operation
- where the unit is exposed to spray or splashing water
- where the unit is exposed to dust
- where the unit is exposed to water vapor
- where the unit is exposed to high density oil vapor
- where the unit is exposed to salty atmosphere
- where the unit is exposed to explosive gas
- where the unit is exposed to excessive shocks or vibrations
- where the angle of inclination of mounting surface is in excess of 10 degrees
- where the unit is exposed to direct sunlight
5. Do not use the unit on infants or persons who cannot express one’s intension
6. Do not use the unit for any purpose other than measuring blood pressure
7. Do not use a cellular phone near the unit improper operation may result
8. Do not force to bend the arm cuff or the air tube excessively
9. When removing the air tube, pull at the connector