Application:
CC - series two stage oil sealed rotary vane vacuum pumps are basic equipment to evacuate domestic, automotive and light commercial refrigeration and AC equipment. They are suitable for use with R134a, R22 and compatible refrigerants.
Refrigeration service tools 2 -
Javac

Pump components

Exhaust Cap Oil Fill Port Intake Fitting Handle
Exhaust fitting
Sight Glass Fan Cover
M Motor Oil Tank
Oil Drain Base Plate Board Technical Specifications: -

Model CC-31 CC-81 CC-141 CC-181 CC-231

Voltage
Free Air
Displacem
ent
Ultimate Vacuum
Motor 1/4 Hp 1/3 Hp 1/3 Hp ½ Hp 2/3 Hp Motor Speed
Oil
Capacity
Dimensions
Net Weight
220/240v 50Hz 220/240v 50Hz 220/240v 50Hz 220/240v 50Hz 220/240v 50Hz
36 l/min 76 l/min 132 l/min 176 l/min 225 l/min
25Micron 25Micron 25Micron 25Micron 25Micron
1440 r/m 1440 r/m 2880 r/m 2880 r/m 2880 r/m
350 ml 380 ml 450 ml 500 ml 500 ml
330x135x255(mm) 350x143x265(mm) 350x143x265(mm) 380x160x285(mm) 380x160x285(mm)
9.8Kg 11.5Kg 12Kg 14Kg 15.5Kg
Power Switch
Refrigeration service tools 3 -
Javac

Before starting: -

Add vacuum pump oil and always check the oil level before use. Low oil level or poor quality oil will result in premature wear and poor performance. Install on a flat surface with adequate ventilation; allow 5cm on all sides of the pump. Remove the intake and exhaust fitting cap and connect via a suitable hose to a manifold or suitable circuit. Connect to a suitable safe power source using earth leakage devices when using extension cords.

Caution:

1) Do not use with combustible, e xplosive, poisonous or reactive/corrosive gases.
2) Do not allow dust particles to enter the pump.
3) Do not allow the pump to run to open air / atmosphere for more than 3 minutes;
4) Do allow the inlet temperature of gases to exceed 80°C. Do not use in environments over 50°C;
5) Not suitable for use as a compressor, transfer pump or recovery pump.
6) Do not operate without oil.
7) Pump surface may be hot.
8) Do not block air outlet when pump is in use.
9) Suitable for indoor use only.
.
Refrigeration service tools 4 -
Javac

Trouble Shooting

Symptom Suggestion? Solution
Add oil to center line of sight glass
Replace with new oil Clean oil inlet and filtering
screen Check hose and vessel for leakage and repair Pump too small – use larger pump Repair or replace with a new pump
Tighten screws or replace O-type ring Drain oil to oil base line on sight glass Use recovery pump to remove pressure
Wait 5 minutes, re start, or press motor reset if installed. Check and eliminate the foreign matter
Check fan, ventilation and repair
Poor vacuum
Oil leakage
Oil discharge
Starting problems
- overheating
1. Oil insufficient
2. Pump oil emulsified, not clean
3. Oil inlet blocked or oil feeding inadequate
4. Pump hose or vessel leak
5. Improper pump chosen
6. Worn components
1. Oil seal damaged Replace with a new oil seal
2. Oil casing gasket loose or damaged
1. Too much oil
2. Inlet pressure too high
1. Temperature below +5C Allow temperature to rise
2. Motor overloaded.
3. Foreign matter falling in the pump
4. Low voltage Avoid long extension leads.
5. Overheated
6. SAFETY If in any doubt. Consult JAVAC
Refrigeration service tools 5 -
Javac

Exploded Drawing

1. Sight glass
2. Oil drain cap
3. Exhaust fitting
4. De-cast Aluminum oil tank
5. Housing gasket
6. Back-pump cover
7. Oil pipe 19. Dill fill port
8. Rotary-vane 20. Inter port
9. Spiral piece 21. Cap-like cover
10. Rotary-vane spring 22. Trestle
11. Back-pump rotor 23. Handle
12. Valve piece 24. Sleeve 31. Shaft seat
13. Back-pump stator 25. Cover 32. Motor Stator
14. Middle fence 26. Capacitor 33. Bearing
15. Molded base 27. Board 34. Motor rotor
16. Restricting piece 28. Switch 35. Motor cover
17. Front pump rotor 29. Motor hull 36. Fan
18. Front pump stator 30. Outlet 37. Fan cover
Refrigeration service tools 6 -
Javac
10.0 WARRANTY
JAVAC warrants your Vacuum Pump to be free from defects of materials or workmanship for one year from the date of purchase. JAVAC does not warrant any machine that has been subjected to misuse, negligence, accident, repaired or altered by anyone other than JAVAC. Javac’s liability is limited to machines returned to JAVAC, transportati on prep aid, not later than thirty (30) days after the warranty period expires, and which JAVAC judges to have malfunctioned because of defective material or workmanship. JAVAC’S liability is limited to, at its option, repairing or replacing the defective machine or part.
This WARRANTY is in lieu of all other warranties, express or implied, whether of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE or otherwise. All such other warranties are expressly disclaimed. JAVAC shall have no liability in excess of the price paid to JAVAC for the machine plus return transportation charges prepaid. JAVAC shall have no liability for any incidental or consequential damages. All such liabilities are EXCLUDED.
JAVAC and or its Agents have the right to charge for costs incurred for incorrectly diagnosed customer warranty claims.
Javac Select products are specially manufactured for Javac by our approved partners
Refrigeration service tools 7 -
Javac
Javac - Supplying the world with Vacuum & Refrigeration Process Solutions
Javac Service Tools Include
Vacuum Pumps
Recovery Machines
Recycle Machines
Charging Units
Leak Detectors
Manifolds
Hoses
Tools & Accessories
Javac UK Limited Europe Office Unit 6 Drake Court, Britannia Park, Middlesbrough TS2 1RS, United Kingdom Tel: +44 1642 232880 Fax: +44 1642 232870
Javac - Supplying the world with Vacuum & Refrigeration Process
lutionsSo
Refrigeration service tools 8 -
Loading...