Jasco 33861 Datasheet

33861 PRODUCT SPECIFICATIONS
myTouchSmart Sunsmart
All-in-One 7-day Digital Timer
Specications
Power: 120VAC Signal Frequency: 60Hz Maximum Load: 1200W tungsten, Ballast 1200VA, Electronic Ballast
5A, 1/2HP motor, 1800W (15A) resistive
Maximum Traveller Length: 200 ft. Operating Temperature: 32-104 °F (0-40 °C) Operating Humidity: 5-85% Minimum Hole for Wire: #12 AWG (0.081 dia) and #14 AWG wire Warranty: 1-year limited product warranty
Requires neutral wire. Switch must be mounted indoors.
Design Features
· Simple myTouchSmart Programming
· SunSmart Technology ­ Automatically adjusts to sunrise and sunset times in your region
· 24 Hour Countdown Mode
· 7-Day - Daily or Weekly Settings
· 8 Custom my ON/my OFF settings
1.69”
(4.29cm)
· ON/OFF button overrides the current setting and blends in with other switches
· Single Pole and 3-Way
· Easy Installation - Screw
 terminals,noyingleads
· Rechargable NiMH battery automatically saves settings and is a back up battery for up to 30 days
· Works with LED, CFL, Incandescent & Halogen
· Light up backlight
· White or Light Almond door gives timer a classy look and works as an On/Off Over-ride switch.
2.81”
(7.14cm)
1.5”
(3.81cm)
www.byjasco.com
White/light almond covers included
4.06” (10.31cm)
ON/OFF switch opens to reveal program buttons
1.75” (4.45cm)
1
33861 PRODUCT SPECIFICATIONS
to the timer
Single-pole Wiring
TIMER
TRAVELER
LOADLINE
Line - Black Load - Black Neutral - White Ground - Green or Bare
NEUTRAL
WALL BOX
Line
Load
Included Neutral Jumper
Wire Strip Length
5/8” (1.6cm)
WIRE
Timer on LOAD Side 3-way Installation
LINE SIDE
Hot Side
Ground
H H
C
5
In a typical 3-way application there are two 3-way switches. The switch on the “HOT” side has the common terminal tied to 120VAC. The switch on the “LOAD” side has the common terminal tied to the load that the switches turn on and off.
Line
3
7
1
Figure 3 - Typical wiring
schematic for 3-way installation
SWITCH ON LINE SIDE
Line
3
6
C
5
5 = Traveler-1 6 = Jumper
*7 = Traveler-2
C = Common terminal
1
2
7
Typical Wiring Diagram for 3-way installation
Figure 4 - Connecting the timer wires for a 3-way installation - timer on load side
Ground
H H
1 = Line 2 = Neutral 3 = Ground 4 = Load
*Traveler-2 (7) carries Line to the timer
LOAD SIDE
Load
TIMER ON LOAD SIDE
TRAVELER
LOADLINE
Traveler-2 (Line)
NEUTRAL
with timer on load side
Load
Neutral
Ground
Traveler-1
3
H H
5
4
7
2
3
5
Ground
7
C
4
Load
Timer on LINE Side 3-way Installation
Hot Side
H H
5
TRAVELER
NEUTRAL
Typical Wiring Diagram for a 3-way installation
LINE SIDE LOAD SIDE
Ground
Line
3
7
C
1
Figure 5 - Typical wiring
schematic for 3-way installation
In a typical 3-way application there are two 3-way switches. The switch on the “HOT” side has the common terminal tied to 120VAC. The switch on the “LOAD” side has the common terminal tied to the load that the switches turn off and on.
TIMER ON LINE SIDE
Line
Neutral
Ground
Traveler-1
5 = Traveler-1 6 = Jumper
*7 = Traveler-2
C = Common terminal
1
7
2
3
5
Figure 6 - Connecting the timer wires for a 3-way installation - timer on line side
LOADLINE
Traveler-2 (Load)
with timer on line side
1 = Line 2 = Neutral 3 = Ground 4 = Load
*Traveler-2 (7) carries Load
Load
5
SWITCH ON LOAD SIDE
H
3
H H
Ground
H
C
7
C
4
Load
4
3
2
6
5
7
Additional Installation Information
· Indoor use only
· Wallplates sold separately
· Bilingual instruction manual – English and Spanish
· Visit myTouchSmart.com for more information
www.byjasco.com
2
Loading...
+ 1 hidden pages