33861 PRODUCT SPECIFICATIONS
myTouchSmart Sunsmart
™
All-in-One 7-day Digital Timer
Specications
Power: 120VAC Signal Frequency: 60Hz
Maximum Load: 1200W tungsten, Ballast 1200VA, Electronic Ballast
5A, 1/2HP motor, 1800W (15A) resistive
Maximum Traveller Length: 200 ft.
Operating Temperature: 32-104 °F (0-40 °C)
Operating Humidity: 5-85%
Minimum Hole for Wire: #12 AWG (0.081 dia) and #14 AWG wire
Warranty: 1-year limited product warranty
Requires neutral wire. Switch must be mounted indoors.
Design Features
· Simple myTouchSmart
Programming
· SunSmart Technology Automatically adjusts to sunrise
and sunset times in your region
· 24 Hour Countdown Mode
· 7-Day - Daily or Weekly Settings
· 8 Custom my ON/my OFF
settings
1.69”
(4.29cm)
· ON/OFF button overrides the
current setting and blends in
with other switches
· Single Pole and 3-Way
· Easy Installation - Screw
terminals,noyingleads
· Rechargable NiMH battery
automatically saves settings and
is a back up battery for
up to 30 days
· Works with LED, CFL,
Incandescent & Halogen
· Light up backlight
· White or Light Almond
door gives timer a classy
look and works as an On/Off
Over-ride switch.
2.81”
(7.14cm)
1.5”
(3.81cm)
www.byjasco.com
White/light almond
covers included
4.06”
(10.31cm)
ON/OFF switch
opens to reveal
program buttons
1.75”
(4.45cm)
1
33861 PRODUCT SPECIFICATIONS
Single-pole Wiring
TIMER
TRAVELER
LOADLINE
Line - Black
Load - Black
Neutral - White
Ground - Green
or Bare
NEUTRAL
WALL BOX
Line
Load
Included Neutral Jumper
Wire Strip Length
5/8” (1.6cm)
WIRE
Timer on LOAD Side 3-way Installation
LINE SIDE
Hot Side
Ground
H H
C
5
In a typical 3-way application there are two 3-way switches. The switch on the
“HOT” side has the common terminal tied to 120VAC. The switch on the “LOAD”
side has the common terminal tied to the load that the switches turn on and off.
Line
3
7
1
Figure 3 - Typical wiring
schematic for 3-way installation
SWITCH ON LINE SIDE
Line
3
6
C
5
5 = Traveler-1
6 = Jumper
*7 = Traveler-2
C = Common
terminal
1
2
7
Typical Wiring Diagram for 3-way installation
Figure 4 - Connecting the timer wires for a
3-way installation - timer on load side
Ground
H H
1 = Line
2 = Neutral
3 = Ground
4 = Load
*Traveler-2 (7) carries Line to the timer
LOAD SIDE
Load
TIMER ON LOAD SIDE
TRAVELER
LOADLINE
Traveler-2 (Line)
NEUTRAL
with timer on load side
Load
Neutral
Ground
Traveler-1
3
H H
5
4
7
2
3
5
Ground
7
C
4
Load
Timer on LINE Side 3-way Installation
Hot Side
H H
5
TRAVELER
NEUTRAL
Typical Wiring Diagram for a 3-way installation
LINE SIDE LOAD SIDE
Ground
Line
3
7
C
1
Figure 5 - Typical wiring
schematic for 3-way installation
In a typical 3-way application there are two 3-way switches. The switch on the
“HOT” side has the common terminal tied to 120VAC. The switch on the “LOAD”
side has the common terminal tied to the load that the switches turn off and on.
TIMER ON LINE SIDE
Line
Neutral
Ground
Traveler-1
5 = Traveler-1
6 = Jumper
*7 = Traveler-2
C = Common
terminal
1
7
2
3
5
Figure 6 - Connecting the timer wires for a 3-way
installation - timer on line side
LOADLINE
Traveler-2 (Load)
with timer on line side
1 = Line
2 = Neutral
3 = Ground
4 = Load
*Traveler-2 (7) carries Load
Load
5
SWITCH ON LOAD SIDE
H
3
H H
Ground
H
C
7
C
4
Load
4
3
2
6
5
7
Additional Installation Information
· Indoor use only
· Wallplates sold separately
· Bilingual instruction manual – English and Spanish
· Visit myTouchSmart.com for more information
www.byjasco.com
2