TABLE OF CONTENTS
TABLE OF CONTENTS and DISCLAIMER ............................................................................................................................. 2
400AP LCR General Description ........................................................................................................................................... 3
400AP LCR Block Diagram .................................................................................................................................................... 3
User Interfaces .................................................................................................................................................................... 4-6
DC Power Jack
USB
RS232
Ethernet
SD Memory Card
20P Header
Reset
Mode
LED Indicators
Antenna Connection
Electrical Specifications ........................................................................................................................................................ 6
Getting Started with the 400AP LCR Router ...................................................................................................................7-12
Before We Begin
Configuring the Router
Ordering Information ............................................................................................................................................................ 13
Revision History ................................................................................................................................................................... 13
DISCLAIMER
The information contained in this document is the proprietary information of Connor-Winfield Corporation and its affiliates (Janus Remote Communication). The contents are confidential and any disclosure to
persons other than the officers, employees, agents or subcontractors of the owner or licensee of this document, without the prior written consent of Connor-Winfield, is strictly prohibited. Connor-Winfield
makes every effort to ensure the quality of the information it makes available. Notwithstanding the foregoing, Connor-Winfield does not make any warranty as to the information contained herein, and does
not accept any liability for any injury, loss or damage of any kind incurred by use of or reliance upon the information. Connor-Winfield disclaims any and all responsibility for the application of the devices
characterized in this document, and notes that the application of the device must comply with the safety standards of the applicable country, and where applicable, with the relevant wiring rules. ConnorWinfield reserves the right to make modifications, additions and deletions to this document due to typographical errors, inaccurate information, or improvements to programs and/or equipment at any time
and without notice. Such changes will, nevertheless be incorporated into new editions of this application note.
All rights reserved 2011 Connor-Wineld Corporation
Terminus 400AP LCR User Guide JA07-UM_LCR Page 2 Rev: A01 Date: 10/23/14
© Copyright 2014 Janus Remote Communications Specifications subject to change without notice
All Rights Reserved See website for latest revision. Not intended for life support applications.
400AP LCR Open Platform General Description
The 400AP Router is a simplified and focused version of our more open platform 400AP single board computer. It’s
designed to give the user an easy up and run cellular routing connection; configurable via web GUI it can be set up
and in use for the end user very quickly.
Powered by the Terminus Common Footprint, the 400AP router can be utilized across various technologies
depending on the user’s needs.
Terminus 400AP LCR User Guide JA07-UM_LCR Page 3 Rev: A01 Date: 10/23/14
© Copyright 2014 Janus Remote Communications Specifications subject to change without notice
All Rights Reserved See website for latest revision. Not intended for life support applications.
Operation
Hardware Requirements:
The following hardware is required for proper operation and setup of the 400AP LCR.
• 400AP LCR
• 12Vdc Power Supply (Janus Part Number: MC-0004)
• Cellular Antennas
• CDMA/EVDO (Janus Part Number: ANT-0073)
• GSM/HSPA+ (Janus Part Number: ANT-0003)
• Cat 5 Patch Cable (Janus Part Number: CBL-0014)
Interfaces
DC Power jack
The 2.1mm center conductor power jack accepts input voltages from 7 to 26VDC.
Pin Description
Center Pin Supply (+)
Outer Conductor Supply (-)
Supply power can also be applied to the unit through the 30 Pin locking header.
USB
There are two USB ports on the 400AP router, one device port and one host port. These by default are unused in the
router configuration.
RS232
The 400AP Router has access to RS-232 through the front end DB9 debug port, this port only contains RX and TX,
but can be used for debugging and lower level access.
Ethernet 10/100 PHY
The 400AP Router contains a single Ethernet port with activity LEDs. Its implementation is compliant with IEEE802.3/
IEEE802.3U 10BASE-T /100BASE-TX standards.
SD Memory Card
The micro SD card socket is connected to the multimedia card interface (MCI) of the 9G20 processor, but is unused
while in the router configuration.
20P Header
The locking header connection breaks out many signals useful to the 400AP, however in the router configuration it’s
largely unused, save for power.
Reset
The reset button is connected to the reset controller of the 400AP. When pressed and released the 400AP is reset.
Terminus 400AP LCR User Guide JA07-UM_LCR Page 4 Rev: A01 Date: 10/23/14
© Copyright 2014 Janus Remote Communications Specifications subject to change without notice
All Rights Reserved See website for latest revision. Not intended for life support applications.