If these instructions are not followed exactly, a fire or explosion may
WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in
which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or
maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual
can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow
warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation can create carbon
monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety,
Zodiac Pool Systems, Inc. strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this appliance and in any adjacent
occupied spaces. Improper installation and/or operation will void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Immediately switch off main gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
result, causing property damage, personal injury, or death.
H0404700 Rev D
Page 2
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
Table of Contents
Section 1. General Information ....................... 3
which could result in severe injury, or death. For indoor
installations, as an additional measure of safety, Zodiac
Pool Systems, Inc. strongly recommends installation
of suitable Carbon Monoxide detectors in the vicinity of
this appliance and in any adjacent occupied spaces.
The heater is designed and manufactured to provide
many years of safe and reliable service when installed,
operated, and maintained according to the information
in this manual and the installation codes referred to
throughout. Be sure to read and comply with all warnings
and cautions.
2. The drinking of alcoholic beverages before or
during spa or hot tub use can cause drowsiness
which could lead to unconsciousness, and
subsequently result in drowning.
3. Pregnant women take note! Soaking in water
above 102°F (38.5°C) can cause fetal damage
during the rst three (3) months of pregnancy
(which could result in the birth of a braindamaged or deformed child). If pregnant women
are going to use a spa or hot tub, they should make
sure the water temperature is below 100°F (38°C)
maximum.
4. The water temperature should always be checked
with an accurate thermometer before entering a
spa or hot tub. Temperature controls may vary by
as much as 1F° (1C°).
5. Persons with a medical history of heart disease,
diabetes, circulatory or blood pressure problems
should consult their physician before using a hot
tub or spa.
6. Persons taking any medication which induces
drowsiness (e.g., tranquilizers, antihistamines, or
anticoagulants) should not use spas or hot tubs.
7. Prolonged immersion in hot water can induce
hyperthermia.
Hyperthermia occurs when the internal body temperature
reaches a level several degrees above the normal body
temperature of 98.6°F (37°C). Symptoms include
dizziness, fainting, drowsiness, lethargy, and an
increase in the internal body temperature. The effects of
hyperthermia include:
1.3.1 Spa/Hot Tub Safety Rules
WARNING
The following “Safety Rules for Hot Tubs,”
recommended by the U.S. Consumer Product Safety
Commission, should be observed when using
the spa.
WARNING
The U.S. Consumer Product Safety Commission
warns that elevated water temperature can be
hazardous. Consult heater operation and installation
instructions for water temperature guidelines before
setting temperature.
1. Spa or hot tub water temperature should never
exceed 104°F (40°C). One hundred degrees
Fahrenheit (100°F [38°C]) is considered safe for a
healthy adult. Special caution is recommended for
young children.
• Lack of awareness of impending hazard
• Failure to perceive heat
• Failure to recognize need to leave spa
• Physical inability to leave spa
• Fetal damage in pregnant women
• Unconsciousness resulting in a danger of drowning
1.3.2 Swimming Pool Energy Saving Tips
Zodiac Pool Systems, Inc., offers the following
recommendations to help conserve fuel and minimize
the cost of operating your pool heater without sacricing
comfort.
®
1. The American Red Cross
recommends a
maximum water temperature of 78°F (26°C). Use
an accurate pool thermometer. A difference of 4F°
(2°C), between 78°F and 82°F (26°C and 28°C),
will use as much as 40% more gas.
Page 4
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
2. Carefully monitor the water temperature of your
pool in the summertime. You can reduce heater
usage due to warmer air temperatures.
3. Find the proper setting on the pool heater
temperature control and use the Set Point Lockout
feature to discourage further adjustments.
4. Set the pump time clock to start the pump no
earlier than 6:00 AM during the pool heating
season. This is the time when nightly heat loss
balances.
5. If the pool is only going to be used on weekends,
reduce the heater temperature control setting by 8
or 10 degrees during the week. Reset it to the 78°F
(25°C) level a day or so before you plan to use the
pool.
6. During the winter or when on vacation for longer
than a week, shut down the heater by following
the shutdown instructions found on the inside of
the heater.
7. Where possible, shelter the pool from prevailing
winds with well-trimmed hedges or other
landscaping, cabanas, or fencing.
8. Always use a pool cover when practical. Besides
providing a valuable safety feature, a pool cover
will reduce heat loss, conserve chemicals, and
reduce the load on lter systems.
1.4 Warranty
This heater is sold with a limited factory warranty. Details
are included with this heater.
®
Make all warranty claims to a Zodiac
dealer or directly
to the factory. Claims must include the heater serial
number and model (this information can be found on the
rating plate), installation date, and name of the installer.
Shipping costs are not included in the warranty coverage.
The warranty does NOT cover damage caused by
improper assembly, installation, operation or eld
modication. Also, damage to the heat exchanger by
corrosive water is NOT covered by the warranty.
NOTE Keep this manual in a safe place for future
reference when inspecting or servicing the heater.
1.5CerticationCodesandStandards
The heater is design-certied by CSA (Canadian
Standards Association) compliant with the latest edition of
the Standard for Gas Fired Pool Heaters, ANSI
in the USA and CSA 4.7 in Canada.
All Jandy Pro Series heaters must be installed in
accordance with the local building and installation codes
as per the utility or Authority Having Jurisdiction (AHJ).
In the absence of local codes, refer to the latest edition of
the following national codes for installation:
®
Z21.56
1. In the United States, the National Fuel Gas Code,
®
NFPA
54/ANSI Z223.1. Pay particular attention
to the chapter addressing Venting of Equipment.
2. In Canada, the Natural Gas and Propane
Installation Code, CAN/CSA-B149.1. Minimum
combustion air requirements MUST be
followed for proper and safe operation. The
Jandy Pro Series JXi heater may not operate
properly when installed with only the minimum
combustion air openings allowed in CAN/
CSA-B149.1.
The JXi pool and spa heaters meet or exceed the
requirements of energy conservation regulations, such as
those in California, Hawaii, New York, Oregon and other
states that have disallowed the use of continuously lit pilot
type ignition sources. In addition, the natural gas models
of this heater comply with the California South Coast Air
Quality Management District's (SCAQMD) Rule 1146.2
for Nitrogen Oxide (NOx) emissions.
Any changes to the heater, gas controls, air orice, gas
orices, wiring, draft diverter, or improper installation
may void the warranty. If change is required to any of the
above, consult the factory.
1.6 General Operation Description
In the JXi heater, the blower draws air and fuel through
specially designed orices for both air and gas, then
delivers the precise mixture to the burner located inside
the combustion chamber. The combustion chamber
is completely sealed and contains the heat exchanger,
which surrounds the burner. Once combustion gases pass
through the heat exchanger, the ow is directed through
an exhaust duct located on the side of the combustion
chamber, where it vents to the atmosphere.
1.7 Safety Controls
The JXi heater is equipped with the following safety
controls to protect internal components and prolong the
life of the heater.
Air Flow Switch
The air ow switch monitors the vacuum (negative
pressure) within the blower housing. The air ow switch
is factory set and the ignition module will not operate
unless the air pressure switch and all safety switches are
satised.
Water Pressure Switch
Operating the heater without sufcient water ow may
severely damage the heater. If water ow to the heater is
restricted, the water pressure switch prevents the burner
from ring. The control panel will display an error
message to indicate water ow is insufcient.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 5
NOTE: If the heater is installed below the level of the pool,(or
more than two feet above the pool level), the pressure
switch setting must be adjusted. See Section 5.4
Adjusting the Water Pressure Switch for guidelines.
Water Temperature Control
All heater models are equipped with an electronic control
which senses water temperature by means of a thermistor
and controls heater operation to bring the water to the
temperature selected. It has an option for two (2) separate
thermostat settings which are typically used to set pool and
spa temperatures.
Ignition Control
The ignition control provides energy for ignition of the air/
gas mixture, monitors the ame and controls the gas valve.
When the temperature control calls for heat, the ignition
control initiates the start-up process by rst purging the
combustion chamber gases. The ignition control will
then energize the igniter and open the gas valve when
the igniter surface is sufciently hot. During the start-up
process and after ignition, the ignition control system is
continually monitoring the ame condition. If the control
senses an unstable ame it will close the gas valve as a
safety precaution.
2.2 Materials Installer Must Provide
For ALL Installations
• The correct size gas pipe to supply gas from gas meter to
heater (see Section 4.1).
• Gas shut-off valve to be installed in gas line outside of the
heater jacket.
• Manual gas shut off valve must be installed in an
accessible location, within 6’ upstream of heater.
• A suitable gas union joint to connect heater to gas line
outside of heater.
• Plumbing materials for providing sediment trap (drip leg)
in gas line between the manual gas valve and heater (see
Section 4.1).
• 120 VAC or 240 VAC power supply. (A junction box is not
needed at the heater; connections are made inside of the
heater jacket.)
For Special Installations
• INDOOR INSTALLATIONS: Factory authorized vent
pipe or elbows sized for indoor installations (US) and/or
outdoor shelter installations (Canada).
• PVC PIPE CONNECTIONS: Primer and cement suitable
for cementing CPVC pipe to PVC pipe. Coupling for
connecting factory-supplied CPVC pipe unions to PVC
pool plumbing
Section 2. Installation
Requirements
2.1 Introduction
Install the JXi in accordance with the procedures in this
manual, local codes and ordinances, and in accordance
with the latest edition of the appropriate national code.
See Section 1.5 for certication codes and standards.
All gas-red products require correct installation to assure
safe operation. The requirements for pool heaters include
the following:
• Field assembly (if required)
• Appropriate site location (clearances) and ooring
(see Section 2.6)
• Sufcient combustion and ventilation air
• Properly sized gas meter and piping
• Proper electrical wiring (if required)
• Adequate water ow
This manual provides the information needed to
meet these requirements. Review all applications and
installation procedures before continuing the installation.
See Section 2.7 for NOTE on operating the heater in areas
with below freezing conditions.
• Liquid Propane (CANADA) -
Certiedforoutdoorandcoveredshelterinstallations
NOTE: Indoor installation is not recommended for
liquid propane heaters. Review information in Special
Precautions for liquid propane heaters (Section 4.1).
Minimum Clearance from Combustible Material
• 6 inch (15 cm) minimum clearance distance
from all surfaces
See Section 2.6 for more information.
Gas Pipe/Heater Gas Valve Connection
• Natural Gas: 3/4" NPT
• Liquid Propane: 3/4” NPT
• For gas pipe sizing requirements, see Table 4.
Supply Gas Type
• Natural Gas
• Liquid Propane
Page 6
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
Inlet Gas Supply Pressure
• Natural Gas:
Minimum 4.0" WC
Maximum 10.5” WC
• Liquid Propane:
Minimum 4.0” WC
Maximum 14.0” WC
Gas Valve Offset Pressure
• Natural Gas: - 0.2" WC (when heater is running)
• Liquid Propane: - 0.2" WC
*NOTE: All readings must be taken while the heater is
operating.
Water Pipe/Heater Connection
• 2" unthreaded slip PVC or CPVC pipe
• Jandy Pro Series union
Water Flow Rate
• Minimum: 30 gpm (76 lpm)
• Maximum: 120 gpm (454 lpm)
Working Water Pressure
• Maximum: 50 psi
• Minimum: 2 psi
Exhaust Vent Connection Size (Category I)
Use type B double-wall gas vent, per table 13.1(a) NFPA 54
• Model 200: 6 "
• Model 260: 7 "
• Model 330: 8 "
• Model 400: 8 "
Exhaust Vent Connection Size (Category III)
See Section 3.0 for information.
Electrical Supply
• 120 VAC
• 240 VAC (factory setting)
High Altitude
• Appliances are normally de-rated when installed at high
elevation. This is not necessary with the JXi heater
because it has a special venturi-type combustion system
which self-compensates for changes in barometric
assured without special adjustment or changes to the
heater.
2.4 Heater Components
1. Gas Valve - The gas valve controls gas ow
into the burner. It enables ow only when the
temperature control requires heat and only if
all safety controls enable operation. It is also a
negative pressure regulator, where it maintains a
gas pressure of 0.2” WC below the the air pressure
at the blower inlet. It regulates the gas pressure to
0.2” WC less than the air pressure at the blower
inlet. This is necessary for proper operation of the
burner system and cannot be accomplished with
common (positive pressure) gas valves.
2. Combustion Blower and Air Orice – The
blower pulls air and fuel gas in through their
respective orices and mixes the two gases before
forcing the fuel/air mixture through the burner
for combustion. During normal operation the fan
will turn on before ame initiation to ensure that
the combustion chamber is clear before the igniter
is energized. Additionally, the fan will run after
the ame is extinguished in order to clear the
combustion chamber of exhaust gas.
3. Pool/Spa Water Temperature Control - The
JXi heater models are equipped with an electronic
control, which senses water temperature by means
of a thermistor and controls heater operation to
attain and maintain the water according to the
temperature selected. It has an option for two (2)
separate thermostat settings, which are typically
used to set pool and spa temperatures.
4. Ignition Control - The ignition control provides
energy for ignition of the air/gas mixture, monitors
the ame and controls the gas valve. When the
temperature control calls for heat, the ignition
control provides a pre-purge of the combustion
chamber. Once the pre-purge is complete the
ignition control then applies electrical power to
a hot surface igniter. When the igniter attains
sufcient temperature, the ignition control opens
the gas valve. Immediately after ignition, the
control system will look for characteristics of a
stable ame and de-energize the igniter. If ame
is not detected shortly after opening the gas valve
the control system will close the valve to prevent
further gas release. The ignition control will
attempt to start 2 more times before an ignition
fault is displayed.
5. Igniter - The hot-surface igniter is constructed of
a ceramic material that attains a temperature great
enough to ignite the air/fuel mixture, when an
electric current is applied.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 7
6. HighLimit Switches - Two (2) limit switches -
one at the heat exchanger rst pass (135°F/57°C)
and one at the heat exchanger outlet (150°F/65°C)
-- prevent water of excessive temperatures from
being discharged from the heater. If either switch
senses excessive temperature, the gas valve will
close and combustion will stop.
7. Water Pressure Switch - Operating the heater
without sufcient water ow may severely
damage the heater. This control senses whether or
not water is available to the heater by measuring
back pressure at the header inlet. If the pool
water pump fails or the water lter is blocked, the
pressure switch prevents operation of the burner.
The display will indicate a no ow fault to alert
you that water pressure is insufcient.
NOTE: If the heater is installed below the surface level of the
pool,(or more than two feet above the pool level), the
pressure switch setting must be adjusted. See section
5.4 Adjusting the Water Pressure Switch.
8. Vent Temperature Limit (240°C/464°F)- This
is a single use switch, which detects abnormal
temperatures in the vent system. It is mounted
to the exhaust duct. Excessive temperatures
will cause the switch to open. Excessive
temperatures can be caused by inadequate water
ow or a compromised heat exchanger. The vent
temperature limit switch will open the safety
circuit which shuts off the gas valve and shuts
down the heater. If this limit is activated/tripped,
the heater cannot be safely operated without rst
determining the cause and without replacing the
limit switch with an exact replacement.
9. Air Pressure Switch - The air pressure switch
monitors the vacuum (negative pressure) within
the blower housing. This switch veries that air
is owing through the combustion system by
sensing pressure. It shuts off the heater if air ow
is inadequate.
2.5 Dimensions
See Figure 1 for exterior dimensions and dimensions to
critical connections.
2.6 Clearances
In both indoor installations (US) and outdoor shelter
installations (Canada), the heater must be placed to
provide clearances on all sides for maintenance and
inspection, as well as maintain minimum distances from
combustible surfaces.
NOTE Clearances are manufacturer’s tested values. These
are given as minimum values. Where local and national codes
apply, and if the clearance values specified in the applicable
codes are different that those listed in this manual, use the
greater value to ensure safest operation.
2.6.1 Combustible Surfaces
The following minimum clearances must be maintained
from combustible surfaces during operation. See Section
2.6.2 for clearances required for service and inspection.
TOP:6 inches (15 cm)
EXHAUST SIDE:6 inches (15 cm) from
surface of the exhaust vent
HEADER SIDE:6 inches (15 cm)
DOOR PANELS:6 inches (15 cm)
The dimensions shown in Figure 1 are certied by CSA
for USA and Canada (outdoor shelter). In Canada, 24
inches (60 cm) clearance is required per CSA B149.1,
section 4.14.2.
26.5"
(67 cm)
16.0"
(40.6 cm)
Figure1. GeneralConguration
EXHAUST SIDE
21.0
22.1"
(56 cm)
25.2"
(64 cm)
6.3"
(16 cm)(58 cm)
FRONT
36.5"
(93 cm)
22.9"
*VersaPlumb®
Sweep Elbow Inlet
*Optional Inlet
18.5"
(47 cm)
10.13"
(25.7cm)
5.6"
(14.2 cm)
Outlet
*Union nut, cap, and O-ring
provided for unused inlet. Sweep
Page 8
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
2.6.2 Service Clearance
Heater must be installed at least 5 feet (1.5 m) from the
inside wall of a pool unless the heater is separated from
the pool by a solid fence, wall or other permanent solid
barrier. For US installations, at least 18 inches (22.5 cm)
access must be available from at least one door panel
for service, inspection, and repair (see Figure 2). In
Canada, at least 24 inches (30 cm) is required for service,
inspection, and repair (see Figure 2).
If removing the header panel for maintenance, allow at
least 4 feet (1.2 m) access clearance.
If installing in a garage, consult the applicable National
Building Code for proper placement of protective bollards
or posts to prevent the heater from damage.
Min.
vertical
clearance:
36ʺ(45cm).
Min.
clearance
to at least
one door
panel:
18ʺ(22.5cm)US
24ʺ(30cm)Canada
Min. distance to
inside wall of pool (unless
separated by a solid wall):
5 feet (1.5 m)
Min. service
clearance
from header
4 feet (1.2 m)
2.8 Location Requirements
CAUTION
When pool equipment is located below the pool
surface, a leak from any component can cause large
Inc., cannot be responsible for such water loss or
oodingorresultingdamage.
Location of the heater below or above the pool water level
affects operation of its water pressure switch. See sections
on water piping and heater start-up for more information.
All criteria given in the following sections reect
minimum clearances as stated in the national standards.
However, each installation must also be evaluated, taking
into account the prevailing local conditions such as wind
speed and direction, proximity and height of walls that
may block ventilation, and proximity to public access
areas.
2.8.1 Flooring
The heater must be installed on a level, solid, and rm
surface or platform. Although it is always advisable to
install the heater on a non-combustible surface, the JXi-
series has been CSA-certied for installation on solid,
rm, and level combustible surfaces.
2.8.2 Outdoor Installation
The heater is factory congured for outdoor installation.
Figure 2. Service Clearance Requirements
2.7 Field Assembly
The JXi heater is shipped from the factory with an exhaust
vent congured for outdoor installation.
The heater is also design-certied for indoor installations
in the United States and outdoor shelter installations
in Canada. The heater has a ue collar for indoor
installations (see Section 3.3.1 for detailed instructions).
Check specications in Section 2.3 for appropriate vent
connection size (Category I).
Water connections are provided on the right side of the
heater but can be changed to the left side by rotating the
heater 180 degrees, so the water manifold is on the left,
then rotating the top panel so that the control panel faces
the operator.
NOTE: If the heater is to be operated in below freezing
conditions it should be installed in a protected outdoor
shelter (see Section 2.8.3).
WARNING
United States
Do not install the heater with the top of the vent assembly within 4
feet (1.22 m) horizontally, 4 feet (1.22 m) below or less than 1 ft (300
mm) above of any opening into a building. Local codes and installation requirements may vary.
Canada
Do not install the heater with the top of the vent asembly within 10
feet (3.05 m) of any opening into a building. Local codes and installation requirements may vary.
• Locate the heater on a level surface in an open,
unroofed area. If the heater is to be installed inside a
contained area, refer to venting requirements, Section
2.8.3.
• Do not install the heater under a deck.
• Do not locate the heater below or adjacent to any
doors, glass openings, louvers, grills, etc., which
connect in any way with an inhabited area of a
building, even though the access might be through
another structure (e.g., a garage or utility room).
• In Canada, install the heater so that the top of the vent
is at least 10 feet (3.0 m) from any building opening.
See Figure 3.
®
Distance from heater to door, window or other opening:
A - USA 4 ft (1.2m) minimum; Canada 10 ft (3 m) minimum
Distance from heater to forced air inlet or other vented opening:
B - USA and Canada If C is greater than 3 ft (0.9m), any distance OK;
If C is less than 3 ft (0.9m), B must be at least 10 ft (3 m)
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
• The top surface of the heater must be at least 3 feet
(0.9 m) above any forced air inlet, or intake ducts
located within 10 feet (3.0 m) horizontally.
• The area under an overhang must be open on three
sides to prevent combustion gases from being diverted
into living areas through doors, windows, or gravity
inlets.
• In the United States install the heater so that there
is at least a three (3) foot (1 m) clearance between
the bottom of the overhang to the top of the heater
exhaust vent.
• If the heater is installed close to a structure, protect it
from rain water runoff with rain gutters on the roof or
other measures.
• Do not locate the heater near irrigation sprinkler
systems that could spray water on it. Water from
sprinklers can damage controls and electronic
components.
• Be sure to divert rain water runoff away from heater
ENGLISH
Page 9
1/4” X 2-1/4”
GALVANIZED OR PLATED
CONCRETE SCREWS (4)
WASHER
“L” BRACKET
HOLE
Figure 4. Anchor Heater To Equipment Pad
NOTE: Other jurisdictions may have similar requirements for
extreme weather. Check your local codes for relevant
Due to the high risk
of extreme weather conditions in Florida, the heater is
required to be securely fastened to the equipment pad
(see Figure 4) to meet the applicable requirements of the
Florida Building Code.
NOTE: Mounting screws are not provided with this heater. Use
size 1/4" x 2-1/4" long galvanized or plated concrete
screws and washers.
1. Place the heater on the equipment pad.
2. Drill a hole in the concrete at each of the brackets
on each corner of the heater. (The correct size drill
bit is usually provided with the concrete screws
when purchased).
3. Place a screw in each of the holes and fasten the
heater to the concrete pad. Do not over-torque the screws.
WARNING
United States
Do not install the heater with the top of the vent
assembly within 4 feet (1.22 m) horizontally, 4 feet
(1.22 m) below or less than 1 ft (300 mm) above of any
opening into a building. Be sure to consult local codes
and installation requirements as some jurisdications
may have varying and more stringent requirements.
Canada
Do not install the heater with the top of the vent
asembly within 10 feet (3 m) of any opening into a
building. Be sure to consult local codes and installation
requirements as some jurisdications may have varying
and more stringent requirements.
The heater is CSA design-certied for indoor installations
in the US and for outdoor shelter installations in Canada.
To install for outdoor shelter area, you will need to
remove the vent housing and the exhaust grate.
When pool equipment is installed indoors, appropriate
containment and drain should be provided to prevent
property damage in the event of equipment leaks.
NOTE: An outdoor shelter is an unoccupied enclosure which
does not communicate directly with occupied areas.
All outdoor shelter installations (Canada only) must have
uninterrupted openings to outside air for combustion and
ventilation. The installation must be in accordance with
the latest edition of CAN/CSA B149.1.
Zodiac Pool Systems, Inc., does not recommend outdoor
Page 10
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
shelter installations that depend on internal air for
combustion (see Table 1).
Due to the higher risks and hazards of Liquid Propane
(LP) gas, Zodiac does not encourage installation of LP gas
heaters indoors. Please be sure to refer to section 4.2 for
additional precautions that must be considered for LP gas.
Section 3. Venting
3.1 Combustion Air Supply
As outlined in the latest edition of ANSI® standard Z223.1
(NFPA
to provide sufcient air supply for proper combustion and
ventilation of the surrounding area.
In general, these requirements specify that the room in
which a heater is installed should be provided with two
permanent air supply openings:
• one within 12 inches (305 mm) of the ceiling
• one within 12 inches (305 mm) of the oor
All indoor installations must have openings to outside
air for combustion, ventilation, and dilution of ue
gases from inside the building. Do not, under any
circumstances, install this product in an indoor location
which does not provide combustion air to the appliance
from outside the building.
In addition, the heater must be completely isolated
and protected from any source of corrosive chemical
fumes such as those emitted by trichlorethylene,
perchloroethylene, chlorine, etc.
®
54), the heater location must be properly vented
Model
200
260
330
400
Table 1. Air Openings to Outside
NOTE: If using screens and/or metal louvers, compensate by
Direct from outsideDuct from outside
2
in
50323100645
65419130839
835351651065
1006452001291
adding 50% additional area to each opening. If using
wood louvers, each opening must be at least four
times the area indicated in the table above.
cm
2
in
2
cm
2
For special conditions, refer to Section 9.3.3.1 NFPA 54
ANSI Z223.
The information in Table 1 is not applicable in
installations where exhaust fans or blowers of any type are
used. Consult a Professional Engineer (P.E.) to ensure that
installations where exhaust fans or blowers are used are
designed and installed in accordance with all applicable
local and national installation codes.
Outside Air Supply: When combustion air is supplied
directly through an outside wall, each opening should
have a minimum free area of 1 square inch per 4,000
BTU/h (1.2kW) input of the total input rating of all
appliances in the enclosed area.
If air is provided through horizontal ducts, each opening
and duct must provide 1 square inch of ow area for
each 2000 BTU/h (0.6 kW). These requirements are
summarized in Table 1.
WARNING
Do not store any chemicals, cleaners, or other corrosive material near combustion air openings or in the
room. Avoid locating appliance vents in the vicinity of
combustion air openings. Failure to prevent corrosive
materials from mixing with combustion air can result in
reduced heater life and unsafe heater operation.
Minimum Net Free Open Area* for Combustion
Openings (square inches/centimeters)
Exhaust Fans or Vents: Any equipment which exhausts
air from the room where the heater is installed can
deplete the combustion air supply or reverse the natural
draft action of the venting system. This could cause ue
products to accumulate in the room. Additional air must
be supplied to compensate for such exhaust.
The information in Table 1 is not applicable in
installations where exhaust fans or blowers of any type
are used. Such installations must be designed by a
Professional Engineer (P.E.).
3.2 Exhaust Venting
When converted to indoor and outdoor shelter venting
conguration, the JXi has a ue collar for attachment to
the venting for category I vertical venting and category
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 11
III vertical and horizontal venting. The only correct
procedure for vent pipe sizing is to do so in accordance
with Table 2 (Section 3.3.2 of this manual) and the
applicable installation code as stated in the following
warning and Table 13.1(a) and 13.1 (b) per NFPA 54
for category I and Table 3 for Category III.
WARNING
Vent pipe materials, sizing, and installation must be
as required by the National Fuel Gas Code NFPA 54/
ANSI Z223.1 or the Canadian Installation Codes for
Gas Appliances CAN/CSA-B149.1. Undersized pipe
can result in inadequate venting and oversize pipe
can result in vent condensation. Improper selection
of vent pipe material, incorrect sizing of the pipe, and
misinstallation of vent piping can result in release of
combustion products to the indoors. This can cause
serious injury or death by Carbon Monoxide poisoning
or asphyxiation.
Note that with horizontal Category III type vent
installations, the venting diameter is four (4) inches and
AL29-4C
vent pipe and elbows. See Section 3.3.1 for procedure to
connect vent pipe and elbows.
®
stainless steel. The JXi ue collar ts 4-inch
resistant and suitable for the specic installation being
considered
• Do not locate the vent terminal where ue products
could strike against building materials and cause
degradation.
• Vent opening should be well away from trees or other
obstructions that would prevent free air ow to and
from vent terminal.
• Do not terminate the vent under decks, stairways, or
car ports.
3.3.1 Vent Pipe or Elbow Increaser Installation
(Category I and Category III)
1. Remove the exhaust body.
2. Remove the exhaust rain shield (see Figure 5).
Exhaust Vent
Rain Shield
3.3 Vent Pipe Sizing and Installation
The JXi may be installed with venting as a Category I or
Category III appliance.
• Category I: A Category I appliance is a vented
appliance that operates with a non-positive vent static
pressure and with a vent gas temperature that avoids
excessive condensate production in the vent. Category
I installations are vented vertically and terminate at
the roof.
• Category III: A Category III appliance is a vented
appliance that operates with a positive vent static
pressure and with a vent gas temperature that avoids
excessive condensate production in the vent. Category
III installations can be vented via a side wall.
In all installations (Category I and Category III):
• Avoid terminating heater vents near air conditioning
or air supply fans. Fans can pick up exhaust ue
products from the heater and return them inside the
building, creating a possible carbon monoxide or
other health hazard.
• Selection of vent pipe type and material must be
carefully considered depending on the type of
installation. Zodiac strongly recommends using high
quality vent pipe materials, which are corrosion
Figure 5. Remove Exhaust Body and Rain Shield
3. Category I:
Install a 4 inch double-wall appliance adapter and
an increaser to meet the vent size requirements per
Table 2. (See Figure 6.)
Category III:
Install vent connector or elbow to the ue collar
according to the specic installation instructions
from the vent connector or elbow component
manufacturer.
Page 12
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
4 inch double-wall
appliance adapter
Increaser
Figure6. CategoryIInstallationConguration
4. Wipe the socket of the vent body with rubbing
alcohol using a clean cloth or paper towel, then.
dry with a different clean cloth.
5. Connect the 4 inch double-wall appliance adapter
for category I or vent connector for category III to
the ue collar and fasten with three (3) sheet metal
screws, as shown in Figure 7).
NOTE: It is important to position the three screws so the seal
in the flue collar is not compromised. Begin with first
screw at 3 o’clock position from top of the flue collar
seam. Install screws 2 and 3 in positions 120 degrees
apart (as shown in Figure 7).
Fasten three
screws, positioned
at 120° intervals
from top seam in
vent collar
screw
(3)
120°
screw
(2)
Start with
screw (1) at
3 o’clock position
seam
120°
120°
screw
(1)
Apply RTV at seal after connecting.
Use minimum 600°F (315°C)
temperature rated RTV.
Figure 8. Seal Connection with RTV
3.3.2 Vertical Venting (Category I)
All indoor installations and outdoor shelter installations
require an approved 4 inch double-wall appliance adapter
and increaser to be connected to the JXi 4-inch ue collar
for Type B installations. Increasers are available in steps
up to a maximum of four sizes larger. 4 inch doublewall appliance adapters and increasers can be obtained
®
from manufacturers such as Amerivent or Duravent
(see Section 2.3 for detailed specications). All vent
installations must be made in accordance with local, state,
or provincial codes and with:
®
• National Fuel Gas Code ANSI
Z223.1 (NFPA® 54),
latest edition; pay particular attention to the chapter
addressing “Venting of Equipment.” Applicable
provisions of additional applicable local building
codes may also need to be followed.
• Canada CAN/CSA B149.1.
Vent the JXi heater vertically in a negative pressure (nonpositive draft) system in accordance with the National
Fuel Gas Code NFPA 54 / ANSI Z223.1 or the Canadian
Natural Gas and Propane Installation Code, CAN/
CSA-B149.1. A type B double-wall vent connector is
required. The heater must not be used to support the vent
pipe.
Figure 7. Correct positioning of screws
on vent collar
6. Apply high temperature silicone RTV at the
connection to seal, as shown in Figure 8.
NOTE: Use a minimum 600°F (315°C) temperature rated RTV.
Note that the tables for fan-assisted appliances include
both maximum and minimum vent loading gures in the
NFPFA 54. The primary purpose of the maximum ratings
are to ensure that the vent operates with negative pressure
throughout its length. The minimum rating refers to the
ring rate.
1. Determine the correct vent size for your heater
according to Table 2.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 13
Notes:
1. Use approved
roof jack.
ADEQUATE AIR
SUPPLY TO ROOM
TOP AND BOTTOM
Figure 9. Indoor Installation Venting (USA) or Outdoor Shelter (Canada) for Category I
1)
Figure 10. Side Wall Vent Terminals for Category III (US installations). Refer to CSA B149 for
2. Install a 4 inch double-wall appliance adapter and
an increaser (see Section 3.3.1).
3. Following the vent connector’s manufacturer
instructions attach the vent pipe to the increaser
and further secure them with sheet metal screws.
Before connecting, wet a clean cloth or paper
towel with rubbing alcohol and wipe the socket
of the vent body. Dry with a different clean cloth.
Vent piping must be adequately supported with no
low spots or sagging that could allow condensate
to collect. The heater must not be used to support
the vent pipe. Horizontal runs must be sloped
upwards away from the heater to a vent terminal
at a minimum of 1/4 " per horizontal foot (2
cm/m).
4. Install the vent pipe so it can expand and contract
freely with temperature changes.
Note: Do not run the heater vent into a common
vent with any other appliance.
3.3.3 Vertical or Horizontal Venting
(Category III)
When the installation requires horizontal venting in excess
of what is allowed for Category I installations or calls
for horizontal discharge, the JXi may be installed with a
Category III venting system.
Vent the heater either vertically or horizontally
®
using Al29-4C
manufacturers such as Z-Flex
stainless steel components.Consult
®
or Heat Fab® to obtain
approved components. Venting materials must comply
®
with UL
1738 for Category III, Special Gas Vent.
In Canada, the venting materials must be ULC S636
compliant.Vent piping must be adequately supported with
no low spots or sagging that could allow condensate to
collect.
The heater must not be used to support the vent pipe.
Horizontal runs must be sloped upwards away from the
heater to a vent terminal at a minimum of 1/4 inch per
horizontal foot (2 cm/m).
Heater
Size
2004" (10cm)TBD (m)
2604" (10cm)50ʹ(15m)
3304" (10cm)TBD (m)
4004" (10cm)50ʹ(15m)
Table 3. Category III Vent Pipe Sizing Table
Vent Size
Special Gas Vent
Length (vertical or horizontal)
in feet (metres)
Side wall vents must be installed and located in
®
accordance with the National Fuel Gas Code NFPA
®
54 / ANSI
Z223.1 or the Canadian Natural Gas and
Propane Installation Code CAN/CSA-B149.1. In addition,
always consult your local installation codes. Some local
installation codes may have requirements that exceed
those of the the national codes. The product must be
installed in accordance with the codes being enforced by
the local Authority Having Jurisdiction (AHJ).
See Figure 9 for side wall vent terminations.
IMPORTANT NOTE In the Commonwealth of
Massachusetts, additional requirements, covered in
document CMR 248 5.00, which supersede some of
the requirements of ANSI Z223.1 (NFPA 54) apply to
Side Wall Horizontally Vented appliances. If installing
this product using an approved side-wall horizontal
vent system in the Commonwealth of Massachusetts,
be sure to adhere to these additional requirements.
These requirements include verbiage that says that
the property owner is to ensure that Carbon Monoxide
Detectors are installed in the vicinity of the appliance
and also on all levels of the dwelling in which the
appliance is installed.
For further instructions, contact Zodiac Pool Systems,
Inc., Technical Support Department at 800.822.7933
(in Canada: 888.647.4004)
1. Install the vent connector or elbow
(see Section 3.3.1).
2. Install the vent pipe so it can expand and
contract freely with temperature changes. Before
connecting, wet a clean cloth or paper towel with
rubbing alcohol and wipe the socket of the vent
body.
3. Follow installation instructions from the
manufacturer of the special gas vent components.
It is recommended that vent runs over 18 feet be insulated
to reduce condensation and/or use a condensate trap in
the vent run close to the heater, especially in certain cold
climate installations.
See Table 3 for recommended vent size and run lengths
without elbows. For each elbow installed, reduce the run
length by 12 feet (3.7m)
WARNING
Incorrect design and installation of heater vents and
ducts can result in personal injury, damage to property,
or death. To avoid such hazards, the heater must
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Precautions Against Common Venting:
Seek the assistance of a Registered Professional Engineer
for proper design of a common venting system.
Zodiac Pool Systems, Inc. does not recommend using
a common vent to vent multiple appliances through a
common duct. However, if no other option is deemed
available by the installer, each appliance must have its
own vent temperature limit switch. All vent limit switches
must be wired in series so as to prevent any appliance
from ring in the event of a blocked vent. An outside
draft inducer must be installed to pull and create negative
®
pressure in the vent system. Refer to ANSI
Z223.1 or
in Canada CAN/CSA B149.1 for more information on
common venting multiple appliances. Do not connect
vent systems of different categories to the same venting
system.
WARNING
Improper installation or maintenance can cause nausea
which could result in severe injury, or death. For indoor
installations, as an additional measure of safety, Zodiac
Pool Systems, Inc. strongly recommends installation
of suitable Carbon Monoxide detectors in the vicinity of
this appliance and in any adjacent occupied spaces.
3.3.4 Inspection and Replacement of Existing Vent
System with New Components
When replacing an existing pool heater with the JXi, it
is recommended that a new appropriate venting system
is installed with the new heater. However, if the existing
venting system must be used, be sure to carefully inspect
the existing system to ensure that it is in good condition
and appropriate for the JXi heater. Replace any parts that
are not in serviceable condition before completing the
installation.
Section 4. Gas Connections
4.1 Install Piping and Check Gas Supply
Gas piping installation must be in accordance with the
latest edition of ANSI Z223.1 and all local codes. In
Canada, the installation must be in accordance with CAN/
CSA B149.1 and all local codes that apply.
The heater must be isolated from the gas supply piping
system by closing the individual manual shut off valve
during any pressure testing of the gas supply piping
system at test pressure equal to or less than 1/2 psi
(3.5kPa).
The heater and its individual shut off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psi (3.5 kPa).
ENGLISH
Page 15
WARNING
The JXi pool and spa heaters are designed for use
with either natural gas or LP gas. Check the rating
plate on the front of the combustion chamber to be
sure that the heater is designed to use the type of gas
being supplied. DO NOT ATTEMPT TO CONVERT
THIS HEATER FOR USE WITH ANY OTHER TYPE
OF FUEL OTHER THAN THE FUEL TYPE FOR
WHICH IT WAS CONFIGURED AT THE FACTORY
AND WHICH IS MARKED ON THE NAMEPLATE.
CAUTION
Permanent damage to the gas valve will occur if the
installation procedures are not followed correctly.
1. Refer to Table 4 for correct gas inlet piping length
from the gas meter to the heater. When sizing gas
lines, calculate three (3) additional feet of straight
pipe for every elbow used.
Distance from Gas Meter
Heater
Size
200
260
330
400
Notes:
• Numbers are for natural gas (0.65 Sp. Gr.) based on 1/2
inch (3.45 kPa) water column pressure drop. Check supply
pressure with a manometer, and local code requirements
for variations. For LP gas, reduce pipe diameter by one
size, but maintain a minimum 3/4 inch diameter.
• Check supply pressure and local code requirements before
proceeding with installation.
• Table shows the minimum supply gas pipe size required.
Larger pipe size can be used if required by local code or
if desired.
• It is critical that the incoming gas supply pressure at the
heater is within the maximum and minimum pressure
requirements. If the range of acceptable supply pressure
is not provided, the gas supply system to the heater must
bemodiedtomeetpressurerequirements.
Table 4. Supply Gas Pipe Size Requirements*
0-50 feet
(0-15 m)
in.mmin.mmin.mm
1251-1/4321-1/432
1-1/4321-1/4321-1/432
1-1/4321-1/4321-1/238
1-1/4321-1/2381-1/238
2. Check the gas meter to make sure it will supply
enough gas to the heater and any other appliances
using the same heater.
NOTE: The gas line from the meter is usually larger than
the gas valve. Therefore, you will need to reduce
connecting pipe as necessary. Make this reduction as
close to the heater as possible.
3. Install a manual gas shutoff valve for service and
safety.
50-100 feet
(15-30 m)
100-200 feet
(30-60 m)
Page 16
3-way
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
4. Install a sediment trap and union ahead of the gas
controls and outside the heater panels, as shown
in Figure 11. Do not use a restrictive gas cock.
DO NOT USE FLEXIBLE GAS PIPING, it will
restrict the gas ow to the heater.
PIPE
UNION
SEDIMENT TRAP
Figure 11. Manual Shut-off Valve and Sediment Trap
NOTE: Close shutoff valve and disconnect the heater to
isolate the heater before pressure testing the gas
supply system.
5. Connect a manometer to the supply pressure port
on the gas valve. While the heater, and when
possible, while all other gas burning appliances
supplied by the common gas delivery system,
are operating, conrm the gas supply pressure is
correct according to Table 5.
8. Test gas offset pressure. See Section 10.
Professional Service and Maintenance.
WARNING
Failure to replace the 1/8 inch NPT gas valve plugs on
inlet, gas offset pressure ports, and cap on the manifold pressure adjustment screw, can result in property
damage, severe injury, or death.
4.2 Special Precautions for LP Gas
Under the same environmental conditions, liquid
propane (LP) gas is more dense than air and will more
readily collect in enclosed areas if there is not adequate
ventilation. It is not recommended to install LP gas
heaters in enclosed areas such as pits. Locate heaters a
safe distance from LP gas cylinders and lling equipment.
Consult the National Fuel Gas Code (NFPA
Z223.1, latest edition), the Liqueed Petroleum Gas Code
(NFPA 58, latest edition), the Natural Gas and Propane
Installation Code in Canada (CAN/CSA B149.1, latest
edition), and any other local codes and re protection
authorities about specic installation restrictions in your
area.
For ALL installations the combustion air openings
requirements and NFPA54 / ANSI Z223.1 MUST be
followed for safe and proper operation.
Section 5. Water Connections
®
54/ANSI®
Gas PressureNatural Propane
Inches W.C.
Maximum inlet10.514
Minimum inlet44
Gas Offset– 0.2– 0.2
Notes:
• All readings must be taken while the heater is operating.
• Any adjustments or readings made while the heater is off
will result in poor performance and problems.
Table 5. Gas Supply Pressure Requirements
6. If the gas supply pressure is less than required,
check for undersized pipe between the meter and
the heaters, a restrictive tting, or an undersized
gas meter.
7. Before operating the heater, test the complete gas
supply system and all connections for leaks using
a soap solution. Do not use an open ame to test
for leaks.
CAUTION
Some leak test solutions (including soap and water)
may cause corrosion or stress cracking. Rinse the
piping with water after testing.
5.1 Water Piping Connections
Install pool system components with connections as
illustrated in Figure 12.
Pool
main
drain
3-way
valve
Spa
valve
Pump
Filter
3-way
valve
Figure12. TypicalWaterPipingConguration
Chlorinator
Heater
check
valve
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 17
Any conguration other than as illustrated in Figure 12
can affect the operation of the water pressure switch.
Locating the heater above or below the pool water surface
can also affect operation of the switch.
NOTE: When pool equipment is located below the pool
surface, Zodiac Pool Systems, Inc. is not responsible
for any large scale water loss, flooding or damage
caused by a leak.
The heater must be protected from back-siphoning of
water, which can result in dry starts. If there is any chance
of back-siphoning, provide a check valve between the
pool and the lter pump inlet.
5.2 Pump Sizing
The internal ow bypass within the heater manifold
will accommodate ows delivered to the heater from a
minimum of 30 gallons per minute (gpm) to a maximum
ow of 120 gpm, depending on the heater model. A
manual bypass valve should be installed when the pump
ow exceeds 120 gpm.
To install a manual bypass valve:
1. Connect ball valve valve between water inlet and
outlet (Figure 13).
ModelMin gpm (lpm)Max gpm (lpm)
20030 (114)120 (454)
26030 (114)120 (454)
33030 (114)120 (454)
40030 (114)120 (454)
Table 6. Recommended Flow Rate Adjustment
3. Remove the valve handle to avoid tampering.
Pump Sizing for New Pool Construction:
When sizing a pump for the system, the head loss for
all system components must be added together when
determining the design ow rate. Component “Head
Loss at Flow” curves are available from equipment
manufacturers.
NOTE: In order to properly establish head loss at flow for a
filter, remember that a “dirty” filter can typically add 10
psi of additional head loss (23 extra feet of head). This
must be considered when sizing a pump for a new
pool system.
Pump Sizing for Replacement in an Existing Pool:
Heater
INOUT
Handle
Ball Valve
Figure 13. Install Manual Bypass Valve
IMPORTANT
The system water pump must be capable of providing
no less than 30 gpm of flow through the heater.
Flow rates at less than 30 gpm may cause nuisance
operation causing the heater to turn off or damage to
the heater.
2. Adjust the valve to bring the ow rate within the
acceptable range (see Table 6).
If the JXi heater replaces a different model of heater,
determine if the existing pump is capable of providing the
minimum ow of no less than 30 gpm indicated in Table
6 for the specic model. JXi heaters are high efciency
heaters. Heaters typical of this construction may have
higher head loss characteristics than the one being
replaced.
IMPORTANT
Heater failure due to insufficient water flow is not
covered under warranty. See measurements in the
Head Loss Chart, Figure 14.
Page 18
Head Loss -JXi Heaters
Design Pressure Drop (psi)
Design Head Loss
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
30
28
26
24
22
20
18
16
14
12
10
(ft head)
8
6
4
2
0
NOTE: Head Loss
Data for Models 200
and 330:
TBD
12
10
8
6
4
2
0
Flow Rate (gpm)
Figure 14. Head Loss Chart
5.3 Plumbing Connections
The heater has a standard 2 inch water header and coupling
design. With this feature, only nominal two inch PVC
or CPVC may be connected to the heater. However, by
installing the appropriate pipe adapters and two (2) short
pieces of two-inch plastic pipe (supplied by the installer),
any size existing pipe may be tted to the heater.
Optional Water Inlet Piping
The water inlet can be piped in one of two possible
congurations. The heater comes with a Zodiac
Sweep Elbow for increased hydraulic performance and
efciency. The sweep elbow also provides the advantage
of its exclusive interface with the Zodiac AquaLink
temperature sensor. The sweep elbow may be installed in
the top inlet connection, and the cap and plug with O-ring
installed to close off the unused side port (see Figure 15).
This conguration may be preferred for Versa Plumb
piping to mating components
®
®
RS
®
SWEEP
ELBOW
(provided)
SWEEP
ELBOW
Figure 15. Top Inlet Piping Using the Versa Plumb
Sweep Elbow
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 19
Optionally, the top inlet opening may be capped with the
union nut and cap, and plug with O-ring provided, then
the water inlet port on the side directly above the outlet
port may be used. (See Figure 16.)
(union nut, cap
and O-ring provided)
IN
OUT
Figure 16. Optional Side Inlet Piping
WARNING
To avoid an electrical shock hazard, which can result
in serious injury or death, ensure that all electrical
power to the system is turned off before approaching, inspecting or troubleshooting any leaking valves
or plumbing that may have caused other electrical
devices in the surrounding area to get wet.
WARNING
Followallltermanufacturer’s
instructions. NEVER attempt to
assemble, disassemble or adjust the
lterwhenthereispressurizedairin
the system. Starting the pump while
there is any pressurized air in the
systemcancausethelterlidtobe
blown off, which can cause death,
serious personal injury or property
damage.
2. After the glue is cured, close the pressure relief
valve on top of the lter.
3. Return all valves to their operating positions.
4. Turn on power to the heater.
5. Turn on the pump to check for water leaks.
6. Restore the gas supply to the heater.
7. Start the system and check for proper water ow.
5.4 Water Pressure Switch Adjustment
CAUTION
The water pressure switch should be adjusted to turn
the heater off when the pump is off. Setting the switch
The pressure switch is preset at the factory for activation
at 2 psi (14 kPa). If the heater is installed below the
surface level of the pool, more than two feet above the
pool level, or any time the pressure is measured at 1 psi
or greater with the system pump off the pressure switch
setting must be adjusted.
Location of the heater above or below the pool water
surface can also affect the operation of the switch. The
factory installed switch can accommodate elevations not
exceeding 6 feet above the pool water surface or 11 feet
below pool water surface. If the heater water connections
are outside this range Consult your local Zodiac
representative for recommendations.
Make sure the pool lter is clean before making any
pressure switch adjustment. A dirty lter will restrict the
water ow and the pressure switch cannot be adjusted
properly.
To adjust the water pressure switch:
NOTE: It is recommended that a Pressure Release Valve
(PRV) be installed prior to taking any of the steps
below. See section 5.7
To install the Sweep Elbow:
1. Clean the cut ends of the pipe and both ends of
the sweep elbow(s) with an appropriate NSF
approved All Purpose cleaner/primer. Glue the
sweep elbow(s) onto the cut pipe ends using an
appropriate All Purpose NSF approved adhesive/
glue.
NOTE Zodiac Pool Systems, Inc. recommends Weld-On
724TM PVC to CPVC Cement to glue Schedule 40
PVC.
1. Set the heater control to the “OFF” mode.
2. Remove the header side panel to access the water
®
pressure switch.
3. Start the lter pump and conrm by means of a
voltmeter that the pressure switch closes (if the
switch fails to close, replace it with a switch that
has a lower minimum setting).
4. Set the heater control to either POOL or SPA.
®
Heater should start.
5. With your ngers, turn the adjustment sprocket
very slowly clockwise until the heater goes off.
(See Figure 17.)
Page 20
Slowly turn adjustment
sprocket clockwise until
heater goes off
Figure 17. Adjust Pressure Switch
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
6. Slowly turn the pressure switch adjustment
sprocket counterclockwise one-quarter turn. The
heater should come back on.
7. Check the adjustment by turning the lter pump
OFF. The burners should shut off immediately.
If they do not, restart the lter pump and repeat
Steps 6 and 7. Check the adjustment again.
8. Return the pool temperature control to the desired
temperature.
It may be necessary to repeat these steps to get a proper
setting. The switch must be set so that the heater will not
re unless the pump is running. If a proper setting cannot
be reached, contact the factory service department.
5.5 Check Valve Installation
When any equipment is located below the surface of the
pool or spa, back-siphoning can occur, which is when the
pump stops and a pressure-suction differential is created.
Check valves should be installed in the piping system to
isolate the equipment from the pool or spa if there is any
chance of back-siphoning. Always install a check valve
if there is a chemical feeder installed in the system (see
Section 5.8).
outlet line is downstream of the heater and a positive seal
noncorrosive check valve is installed between the feeder
and the heater.
5.6 Reversing the Water Connections
The JXi heater is shipped with water connections on the
right side, but the top panel can be rotated to adapt to leftside water connections. This procedure involves turning
the heater and then removing and rotating the top panel of
the heater. The heater wiring procedure must be done only
by a trained service technician.
5.7 Pressure Relief Valve Installation
A pressure relief valve (PRV) is recommended in all
installations, and is mandatory in any installation in which
the water ow can be restricted between the heater outlet
and the pool/spa.
A pressure relief valve is not supplied with the JXi heater.
However, it is recommended that a pressure relief valve
be installed and may even be required by local codes.
Be sure to check any applicable installation codes in
your area to determine whether a pressure relief valve is
required.
The maximum working pressure of this heater is 50 psi.
Be sure to take into consideration the maximum allowable
pressure of the other components in the system when
selecting a PRV. Any pressure relief valve installed must
comply with provisions of the standard described in
®
ANSI
To install a pressure relief valve:
Z21.22 for the United Sates or CSA 4.4 in Canada.
1. Locate the threaded boss on the outlet port of the
in/out header (beside the “out” arrow). See Figure
18.
2. Note the dimple at the center of the blind bottom
of the boss. Using the dimple to center the
drill bit, drill a 1/4" diameter hole through the
bottom of the boss, taking care not to damage
he surrounding plastic threads. (TIP: Drilling a
1/8" diameter hole rst will help prevent thread
damage.)
WARNING
A check valve can interfere with the proper operation
of certain Suction Vacuum Release System (SVRS)
products. To avoid possible entrapment hazard,
serious injury, or death, make sure to review the
operation/owners manual of your particular SVRS
product before installing the check valve.
Do not install any shutoff valve in the piping between
the heater outlet and the pool, unless it is being used as a
diverter valve. Always use care when installing chemical
feeders so that there is no back-siphoning of chemical
into the heater, lters, or pump. Make sure the feeder
WARNING
Drilling through plastic can often cause the drill bit to
‘grab’, causing the drill motor to twist in your hand.
Holddrillrmlytoavoidpotentialinjury.
NOTE: The fittings must be installed immediately after the
outlet with no valves or other components inbetween.
The pressure relief valve must be installed at the outlet
port. Do not install at either of the header inlet ports.
3. Install a brass 3/8 NPT x 3/8 NPT x 3" long pipe
nipple into the boss, using 5 to 6 wraps of Teon
tape on the threaded end. Do not overtighten. See
Figure 18.
®
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
CAUTION
UseTeon® tape only on the threads of the pipe nipple
attachment to the plastic header. Do not use any pipe
compound or pipe dope on the threads or any part that
comes into contact with the plastic headers. These
compounds may damage the header over a period of
time.
3/4-inch
NPT PRV
Heater
Water
Out
2-inch
Tee
3/8-inch
NPT
nipple
3/8-inch
NPT
3/4-inch NPT
to 3/8-inch
NPT reducer
ENGLISH
NOTE: To ensure the continued proper operation of the
pressure relief valve, the valve should be tested once
a year. To test, lift the lever with the circulation system
running to ensure that water will pass through. When
the lever is down, there should be no leaks from the
outlet.
Page 21
5.8 Auxiliary Components, Chlorinators,
Ozone Generators, and Sanitizing
Chemicals
The JXi heater is manufactured with materials that are not
compatible with high concentrations of ozone, chlorine,
bromine, or other sanitizing chemicals. Heater damage
caused by excessive chemicals or improper ozonization is
not covered by the Zodiac Pool Systems, Inc., warranty.
Be sure to adhere to the following:
• When ozone is injected upstream of the heater,
install an offgas mixing chamber, or an ozone bypass
system between the heater and the ozone injector to
prevent ozone and air from entering the heater.
• When chemical feeders are used, plumb the feeder
downstream of the heater and install an in-line check
valve between the heater and the feeder (a minimum
of 18 inch is required between the heater and the
check valve).
• Wire any electrical chemical feeder so that it cannot
operate unless the lter pump is running. If the feeder
has an independent clock control, synchronize it with
the lter clock.
Figure 18. Pressure Relief Valve Installation
4. Wrap 5 or 6 turns of Teon tape on the end of
the pipe nipple and install a 3/8 NPT brass elbow
while holding the pipe nipple from rotating. Orient
the elbow to point straight up. See Figure 18.
5. Install a brass 3/4 NPT female to a 3/8 NPT male
pipe adapter to the elbow using 5-6 turns of Teon
tape on the male end of the adapter. See Figure 18.
6. Install the pressure relief valve on the elbow.
Use 5-6 turns of Teon tape on the male end of
the valve. Install the pressure relief valve so it is
vertical. See Figure 18.
7. Install a drain pipe from the pressure relief
valve outlet to a safe area. This is a precaution
to prevent the possibility of personal injury or
property damage in the event scalding water is
discharged from the pressure relief valve.
Install the drain pipe so that there is no trapped or
standing water in the piping. Drain piping must be
facing down, terminating with a threadless nipple,
no less than 6” from oor. It must be open with no
reducers or shut-off valves or other restrictions.
• Never deposit chemicals directly in the pool
skimmer.
Section 6. Electrical
Connections
WARNING
ELECTRICAL SHOCK HAZARD. This heater contains
wiring that carries high voltage. Contact with these
wires may result in severe injury or death.
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
6.1 General Information
Wiring connections must be made exactly as shown in
the wiring diagram found on the inside of the heater door.
The heater must include a denite means of grounding.
There is a bonding lug on the right side of the heater,
where a bond wire must be attached. For specic wiring
connections, see Figure 19.
Page 22
die line, does not print
H0402900 Rev D
6.25 x 7.0
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
OPTIONAL
BYPASS
Alternate 120V Wiring*
120 VAC
NEUTRAL
240 VAC
HEATER
POWER
SUPPLY
HOT
R
BK
G
R
BK
G
BK
WATER
BK
TEMP
COIL/AIR
TEMP
BR
GAS
Y
VALVE
USER
INTERFACE1
BK O BL
HEATER
POWER
SUPPLY
Voltage Selector Card Must Be Rotated.
WATER
TEMP
SENSOR
UNIVERSAL
CONTROLLER
USER INTERFACE
POWER
INTERFACE
BK O BL R
R
ACN1
BL
F1
W
L2
BK
L1
BK
ACH1
BK
F2
UNIVERSAL
CONTROLLER
POWER INTERFACE
R
W
BK
BL
BK
R
Y
BL
W
HIPRESS/
HILIMIT
WWWBL
LIMIT
SWITCH
57˚C
(135˚F)
W
BK
BL
LOPRESS/
FUSELINK
OVGY
TRANSFORMER
WATER
PRESS
LIMIT
SWITCH
66˚C
(150˚F)
R
24 VAC
Y
BLOWER
MOTOR
REMOTE
SPA POOL COM
FUSE
FAN/
LOUVER
PUMP
COMP/
IGN
24VAC
REV
VALVE
BK/Y
Y/BK
J3 CONNECTOR
VENT
TEMPERATURE
LIMIT
240˚C
(464˚F)
BK
BL
F1
W
O
R
Y
F2
IGNITION CONTROL
IGN
L1 L2
120
BK
GYBK
W
GY
HOT SURFACE
IGNITER
TO COMBUSTION
LOUVER STARTER
AIR
USED)
(IF
TO PUMP STARTER
CONTACTS (IF USED)
R
24
VAC
IGN
FS
FV+
FV-
PSW
W
O
Y/BK
W
Factory Wired 24V
Factory Wired 120V/240V
BK - BLACK
BK/Y - BLACK WITH YELLOW TRACE
BL - BLUE
BR - BROWN
G - GREEN
WATER
PRESS
SWITCH
GY - GRAY
O - ORANGE
R - RED
V - VIOLET
W - WHITE
Y - YELLOW
Y/BK - YELLOW WITH BLACK TRACE
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 23
6.2 Service Access
The electrical component panel may be rotated up
and away from the heater body for easier access to the
electrical system. With the front panel removed, press the
tab in the raceway (as shown in Figure 20) , then rotate
the panel upward. The latch should hold in place.
1
Press Tab
To Release
2
Lift Up
To Latch
Figure 20. Electrical System Service Access
Press to Release
and Return to Down Position
WIRES AS SHIPPED
CONNECT WIRES INSIDE HEATER
Figure 21. Field Wiring Connections
CONDUIT
ELBOW
6.3 Main Power
Electrical wiring must be in accordance with the latest
edition of the National Electric Code
National Fire Protection Association
in Canada, the Canadian Electrical Code (CSA
unless local code requirements indicate otherwise.
The heater comes factory-wired intended for use with 240
Volt, 60 Hz AC eld electrical supply. To use 120 Volt,
60 Hz AC requires changing the position of the voltage
selector board on the power distribution board. This must
be done by a certied electrician only, as with all wiring.
Be sure that the power source to the heater is turned off or
disconnected before servicing.
NOTE If the heater is converted to accept 120V, the “Hot”
wire of the 120V power supply has to be connected to
the black wire (ACH1) on the power distribution board
and the “Neutral” wire of the 120V power supply has
to be connected to the red wire (ACN1) of the power
distribution board.
To wire the heater to 120V or 240V/60 Hertz (Hz):
1. Remove the front door panel of the heater.
2. Connect the wires from the power source to the
leads on the heater (Figure 21).
®
(NEC®), ANSI®/
®
(NFPA®) 70, or
®
C22.1)
6.3.1 Converting the Heater for a 120V Power
Source
WARNING
ELECTRICAL SHOCK HAZARD. To avoid an
electrical shock hazard, which can result in serious
injury or death, ensure that all electrical power to the
system is turned off before approaching, inspecting, or
troubleshooting any leaking plumbing that may have
caused electrical devices in the surrounding area to
get wet.
The heater is congured at the factory to operate at 240
VAC, 60 Hz; to convert.the heater to 120 Volt, 60 Hz
AC, reverse the voltage selector board on the power
distribution board before the heater is connected to a
power source:
To convert the heater to 120V 60 Hertz (Hz):
1. Identify the power distribution board on the heater
to the right of the ignition control on the raceway
(Figure 22).
NOTE No external junction box is required.
Page 24
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
do so will void the Zodiac Pool Systems, Inc. warranty.
Additionally, in the United States the National Electrical
®
(NEC®) and in Canada the Canadian Electrical
Code
Code (CEC), require that all metallic components of a
pool structure, including reinforcing steel, metal ttings
and above ground components be bonded together
(forming an “equipotential bonding grid”) with a solid
copper conductor not smaller than an 8 AWG (6 AWG in
Canada).
Ignition Control
Power Distribution Board
Figure 22. Power Distribution Board
2. Cut the plastic wire tie fastening the voltage
selector board in place and discard it. Be careful
not to abrade or damage any wiring or other
components. Unplug the voltage selector board
from the receptacle. See Figure 23.
POWER
DISTRIBUTION
BOARD
WIRE TIE
VOLTAGE
SELECTOR
BOARD
Figure 23. Power Distribution Board With Voltage
Selector Board Installed for 240 VAC
3. Rotate the voltage selector board 180° and reinsert
it into the receptacle so that the hole in the board
is not visible. Be sure that the board is securely
seated in the receptacle.
NOTE The voltage selector board is keyed so that it will fit in
only one (1) direction for either selected voltage (either
side of the board).
The NEC and CEC also require that the equipment and/
or appliances associated with the pool water circulating
system, including, but not limited to, pump motors and
heaters, be bonded together as part of the equipotential
bonding grid. Zodiac Pool Systems, Inc. provides a
special labeled bonding lug on the right side of the heater
to accommodate this requirement.
6.5 Optional Remote Controls
The JXi pool/spa heater controls can be wired for remote
operation. All Zodiac
permit the heater to be operated by remote control.
If you are setting up a new pool or spa system, call your
local Jandy Pro Series distributor or Zodiac Pool Systems,
Inc., 800.822.7933, for information on the correct Control
System to meet your needs.
®
AquaLink® Control Systems will
WARNING
RISK OF ELECTRIC SHOCK WHICH CAN RESULT
IN SERIOUS INJURY OR DEATH. Before attempting
installation or service, ensure that all power to the
device is disconnected/turned off at the circuit breaker.
Electrical wiring must be in accordance with the latest
edition of the National Electric Code (NEC), ANSI
National Fire Protection Association (NFPA
local code requirements indicate otherwise.
Refer to Figure 19 for electrical connections and wiring
schematic.
®
®
) 70, unless
/
6.4 Bonding
CAUTION
To prevent premature failure of the appliance resulting
from stray voltages and voltage differentials, the heater
must be bonded to other equipment which is part of
the pool plumbing system with a solid copper wire not
smaller in diameter than 8 AWG (6 AWG in Canada).
Zodiac Pool Systems, Inc., requires that the appliance be
connected to a “bonding loop” that includes all electrical
equipment in the system and on the equipment pad.
Bonding lugs must be connected with a solid copper wire
not smaller than 8 AWG (6 AWG in Canada). Failure to
6.5.1 Connecting to a Remote Pool-Off-Spa
Selector (3-Wire Connection)
Install the Remote Pool-Off-Spa Selector:
1. Turn off the power to both the pool/spa control
system and the heater unit.
2. Remove the front panel door.
3. Run the wires from the pool/spa control system
through the opening located on the lower right or
left hand side of the heater.
4. Connect the wiring from the pool/spa control
system to the heater remote control terminal.
5. Connect the three wires to Spa, Pool & Common
terminals of the J6 terminal bar.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 25
6. Reinstall door panel.
7. Restore power to the heater and the pool/spa
control system.
ConguretheControlPanel:
1. Make sure the control is OFF.
2. Press and hold MENU, then the POOL and SPA
buttons for 7 seconds to access Service Setup
mode.
NOTE The display will revert back to OFF after 1 minute
since the last key press.
3.
Press Up or Down to display REMOTE.
4. Press MENU, REMOTE OFF (default remote) is
displayed.
5. Use Up or Down to scroll through the Remote
options until
HI-LO-COM is displayed, then press
MENU to select..
6. Press POOL or SPA to exit Service Setup mode.
6.5.2 Connecting to an AquaLink® Control System
or Remote TSTAT (2-Wire Connection)
An interrupt (on/off-type) remote can be connected as
a Remote TSTAT to turn the heater on or off but not
perform any other function. When using this type of
connection, remember to set the heater control to “SPA”
and set the thermostat control to maximum.
Consult with the Zodiac Pool Systems, Inc. Technical
Support Department, 800.822.7933 (in Canada:
888.647.4004), for questions about installing non-Zodiac
remote controls.
Install the Remote TSTAT:
1. Turn off the power to both the pool/spa control
system and the heater unit.
2. Remove the front panel door.
3. Run the wires from the pool/spa control system
through the opening located on the lower right or
left hand side of the heater.
4. Connect the wiring from the pool/spa control
system to the heater remote control terminal.
5. Connect the two wires to Pool and Common (not
Spa) on the J6 terminal bar.
6. Reinstall door panel.
7. Restore power to the heater and the pool/spa
control system.
NOTE If you install a time clock to control the filter pump
operation, it is recommended that the time clock have
its own low voltage (Fireman’s) switch to turn off the
heater before turning off the pump. The switch should
shut off the heater about 15 minutes before the filter
pump shuts off. This will allow for a more efficient
operation by removing any residual heat contained in
the heat exchanger back to the pool.
CAUTION
To avoid damage to the heater, do not connect the
power supply of the heater to the output side of
the clock if your time clock simply interrupts the high
voltage power supply or has a high voltage output. Doing so will prevent the blower from purging the residual
heat from the heater when the heater turns off. The
blower must be allowed to run for 45 seconds after the
heater shuts off.
ConguretheControlPanel:
1. Make sure the control is OFF.
2. Press and hold MENU, then the POOL and SPA
buttons for 5 seconds to access Service Setup
mode.
NOTE The display will revert back to OFF after 1 minute
since the last key press.
3. Press MENU, REMOTE OFF (default remote) is
displayed.
4. Use Up or Down to scroll through the Remote
options until
press MENU to select.
5. Press POOL or SPA to exit Service Setup mode.
6. Press SPA to adjust the setpoint to the maximum
40°C (104°F).
6.5.3 “Smart” Communication via RS-485
To provide “smart” communication between the JXi and
a power center board (PCB) (AquaLink RS, AquaLink
PDA, and AquaLink Z4) through a red four-pin RS485
connector, your PCB must have the appropriate rmware.
To determine the REV of the AquaLink RS PCB rmware
in your system, refer to Table 7.
Components
RS485
Connectors
JVA Sockets
24 VAC
Relay Sockets
24 VDC
Table 7. AquaLink RS Power Center Board
Identifying Features
REMOTE TSTAT is displayed, then
REV MMM
or lower
One (1) set of
four (4)
Located on top of
board
10 total sockets.
Eight (8) located on
bottom, two (2) on
top of board
REV N
or higher
Two (2) sets of
four (4)
Located on bottom
of board
11 total sockets.
All located on
bottom of board.
Page 26
Filter Pump
Filter Pump
Solar Pump
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
Do not connect more than two (2) wires to any of the
terminals in the Control System when connecting
peripheral devices. If connecting the heater to the control
system creates this situation, then a Multiplex PCB
kit must be used. Call your distributor or Zodiac Pool
Systems, Inc., to order the kit.
Indoor Controller
654321
109876 54321
4321
4321
To Sensors, etc.
To Remote
To Controller
(green terminal bar)
(brown terminal bar)
(red terminal bar)
RS6 & RS8 ONLY
RS8 ONLY
RESET
AUTO
SERVICE
TIME OUT
POOL MODE
SPA MODE
AUX 6
AUX 3
AUX 7
AUX 2
AUX 5
AUX 4
AUX 1
FILTER PUMP
SPA DRAIN
SOLAR
HEATER
Power
SPA FILL
Center
Bezel
Connection to
Controller:
RS485 Connectors
4321
RESET
S1
AUTO
SERVICE
TIME OUT
S2
Aux 2
Aux 1
Relay Sockets
24 VDC
4321
FILTER PUMP
Aux 3
Aux 4
AUX 1
Aux 6
Aux 5
Spa
Side
Switch
654321
AUX 3
AUX 2
Aux 7
Sensors
and
Heater
10 9876 54321
RS6 & RS8 ONLY
RS8 ONLY
AUX 6
AUX 7
AUX 4
AUX 5
Intake
Return
JVA Sockets
24 VAC
HEATER
Solar
Cleaner
POOL MODE
SPA MODE
SPA DRAIN
SOLAR
SPA FILL
Spare
Elect. Htr.
Relay Sockets
24 VDC
Figure26. PCBwithrmwareREVNorhigher
Power Center
RS Control
System
4 Conductor
JXi Control
LXi Control
4 3 2 1
GR Y BK R
Figure 24. Wiring the JXi to a Zodiac® Remote
Return
HEATER
Solar
Cleaner
SOLAR
Relay Sockets
24 VDC
Elect Htr
Solar Pump
POOL MODE
SPA MODE
SPA DRAIN
SPA FILL
Connection to
Controller:
RS485
Connectors
4321
Spa Side
Switch
654321
RESET
AUTO
SERVICE
TIME OUT
Sensors and
Heater
10 9876 54321
AUX 3
AUX 2
AUX 1
FILTER PUMP
JVA Sockets
24 VAC
Intake
RS6 & RS8 ONLY
RS8 ONLY
AUX 6
AUX 7
AUX 4
AUX 5
22 Gauge
Wire
If your PCB rmware is REV MMM or lower, connect
via a 2-wire connection. See Section 6.5.2.
IfyourPCBrmwareisREVNorhigher:
1. Turn off the power to both the heater and the
controller.
2 Open the power center enclosure and remove the
front dead panel.
NOTE Only an AquaLink
"N", or higher, will support the heater interface. Refer
to Table 7 and Figures 25 and 26 to determine the
REV of your system's firmware. If it is "N" or higher,
continue with these procedures. If it is MMM or lower,
follow the procedures in Section 6.5.2.
NOTE Only a PDA System with firmware revision 4.1, or
higher, will support the heater interface.
®
RS System with firmware revision
3. Use 22 gauge 4-conductor wire to run between
the heater and the RS control and match the wire
color order (Figure 24).
4. The wires coming from the heater can be
“doubled up” on the red terminal bar with the four
(4) wires from the indoor controller.
Aux 4
Aux 1
Aux 2
Relay Sockets
24 VDC
Aux 3
Aux 5
Relay Sockets
24 VDC
Figure25. PCBwithrmwareREVMMMorlower
Aux 6
Aux 7
NOTE If you need to install more than two (2) wires in each
terminal, order a Zodiac
®
Multiplex PCB Kit, which
includes the Multiplex Board (Zodiac part # 6584).
Never put more than two (2)wires into each of the pins
of the terminal bar.
5. Check all wiring, then apply power to both the
heater and the control system. Verify operation
in either Service or Auto mode. Refer to your
Control System manual for operating instructions.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 27
When the heater is connected to an external controller,
all functionality of the heater control panel is disabled,
therefore heater functions can be controlled only from the
controller.
To restore heater control panel functionality after
connecting to an external controller:
1. Turn power to the heater ON. The heater display
shows:
MENU TO DISABLE
JANDY REMOTE ONLINE PUSH
.
2. Press MENU to remove message and restore
functionality to the heater control panel.
To return functionality to RS:
1. Turn power to the heater OFF then back ON.
2. Press MENU for 5 seconds to access Setup Mode.
3. Choose JANDY REMOTE.
Section 7. Operating Instructions
7.1 First-Time Start-Up Procedure
WARNING
Vent pipes and heater tops get hot! These surfaces
can cause serious burns. Do not touch these surfaces
while the heater is in operation.
inspect the heater and replace any part of
the control system and any gas control which has
been under water.
Should overheating occur or the gas supply fail to shut
off, turn off the manual gas control valve to the heater.
Do not attempt repairs on the gas controls or
appliance. Tampering is dangerous and voids all
warranties.
1. Conrm that pool water is owing normally
through the pool system and equipment.
2. If it is a new pool or spa installation, operate the
lter pump with the heater off long enough to
completely clean the water. This will remove any
installation residue from the water.
3. Clean the lter before starting the heater.
4. Start the heater in either Pool or Spa mode (see
section 7.6, Operating the Heater).
5. Start the heater (see section 7.2, Lighting the
Burner).
6. When the heater starts, conrm there is adequate
water ow by touching the outlet header. The
header should not be hot. Normally, water
temperature will rise only a few degrees as it
passes through the heater, and a “hot” header or
pipe indicates low water ow.
If ignition is unsuccessful:
If ignition is unsuccessful, or the ame fails during normal
operation, the ignition control shuts off the gas valve.
The heater will then go through a post purge process and
attempt to establish stable combustion two additional
times. If ignition is unsuccessful after three attempts,
the system shuts down and will automatically attempt to
restart after one hour.
To reset the heater to provide three (3) attempts to start:
1. Turn OFF the control then turn it back ON.
2. Access either the Pool or Spa mode.
7.2 Starting the Heater
Follow the instructions outlined below to start the heater.
Refer to the Lighting and Shutdown Instructions label on
the inside lid panel of the heater (Figure 29).
WARNING
If you do not follow the instructions below exactly, a
(A) This appliance does not have a pilot light. It
is equipped with an ignition device, which
automatically lights the heater. Do NOT try to
light the burners by hand.
(B) BEFORE OPERATING, smell all around the
appliance for gas. Be sure to smell next to the
oor because some gas is heavier than air and will
settle on the oor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any
phone in your building.
- Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
- If you cannot reach your gas supplier, call the
Fire Department.
Page 28
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
(C) Use only your hand to switch on or off the gas
control switch. Never use tools. If the switch
appears broken or will not move, don’t try to
repair it, call a qualied service technician.
Force or attempted repair may result in re or
explosion.
(D) Do not use this appliance if any part has been
under water. Immediately call a qualied service
technician to inspect the appliance and to replace
any part of the control system which has been
under water.
OPERATING INSTRUCTIONS
Refer to the Lighting and Shutdown Instructions (Figure
29) label located on the heater on the inside of the top
panel.
1. STOP! Read IMPORTANT SAFETY
INFORMATION in previous section.
2. Set temperature thermostat controls to their
lowest setting and turn off the controller. Make
sure the display shows GAS HEATER IS OFF.
3. Turn off all electrical power to the heater at the
junction box.
NOTE: This appliance is equipped with an ignition
device which automatically lights the heater. Do NOT
try to light the burners by hand.
4. Remove the heater door panel.
5. Toggle gas control switch to OFF position.
(See Figure 27).
GAS CONTROL
ON/OFF SWITCH
7. If no gas is detected, toggle gas control switch to
ON position.
8. Replace the door panel.
9. Turn on electrical power to the heater.
10. Turn the controller ON by pressing POOL or SPA
and set the temperatures as necessary.
NOTE: If the heater does not start, check that the filter pump
is ON, the filter is clean and that water is flowing to
the pool. If the heater still does not operate, follow the
procedure below (Shut Down) to turn off gas supply to
or sharp odors may be emitted from the vent during
this period. Do not inhale combustion product fumes
at any time, and especially when these fumes are
being emitted. This “burn-in” period will last only a few
minutes.
TO TURN OFF GAS TO THE HEATER
1. Set temperature thermostat controls to their
lowest setting and turn off the controller. Make
sure the display shows GAS HEATER IS OFF.
2. Turn off all electrical power to the heater at the
junction box.
3. Remove the heater door.
4. Turn the gas valve control switch to OFF.
5. Shut off the external gas supply valve to the
heater.
6. Replace the door panel.
Figure 27. Gas Valve
6. Wait ve (5) minutes to clear out any gas, then
smell for gas, including near the oor. IF YOU
SMELL GAS, STOP! Follow instructions in
section (B) WHAT TO DO IF YOU SMELL GAS
in IMPORTANT SAFETY INFORMATION
section.
7.3 Normal Operation
During normal operation, the control system measures
the temperature of the water owing through the heater
and will begin the start-up process if the temperature is
below the set point. If the blower pressure switch senses
adequate airow when the blower starts, the ignition
sequence begins. Following a pre purge, the igniter is
energized, then the gas valve opens. As long as a ame
is sensed at the burner, operation continues until the
temperature of the water entering the heater reaches the
temperature control setting.
7.4 Operating the Controller
Unless the heater is connected to a remote controller,
all operations are set up and programmed through the
control panel on the top of the heater (Figure 28).
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 29
GAS HEATER IS OFF
PRESS POOL OR SPA
POOL
MENU
Figure 28. Main Control Panel
NOTE
The display reverts to OFF after one minute of
inactivity since the last key was pressed.
SPA
7.5 Setting up Heater Options
Before using the heater for the rst time, set up the
following options:
• Languages:
Set a default display language
• Temperature Scale:
Set temperatures to be displayed in either Celsius or
Fahrenheit scale
• Display LightTimeout:
Set the display light to turn off after a specic interval
of inactivity
To Program the Display Language:
1. Make sure the control is OFF.
2. Press and hold MENU for 5 seconds to access
Setup.
3. Press Up or Down to display:
SETUP LANGUAGE
4. Press
MENU.
.
SELECT LANGUAGE ENGLISH (default
language) is displayed.
5. Press Up or Down to scroll through available
languages.
6. Press
7. Press
To Program the Temperature Scale (F or C):
MENU to select a language.
POOL or SPA to exit the User Setup mode.
1. Make sure the control is OFF.
2. Press and hold MENU for 5 seconds to access
Setup.
3. Press Up or Down to display:
SETUP TEMPERATURE SCALE
4. Press
MENU.
SELECT TEMP SCALE °F: (default scale) is
displayed.
SELECT USER
SELECT USER
.
5. Press Up or Down to toggle between
6. Press
7. Press
To Program Display Light to Turn Off Automatically:
MENU to select scale.
POOL or SPA to exit the User Setup mode.
°F and °C.
1. Make sure the control is OFF.
2. Press and hold MENU for 5 seconds to access
Setup.
3. Press Up or Down to display:
SETUP DISPLAY LIGHT
4. Press
MENU.
SELECT USER
.
SELECT DISPLAY LIGHT 2 MIN TIMEOUT
(default display turn off time setting) is displayed.
5. Press Up or Down to choose:
DISPLAY LIGHT 2 MIN TIMEOUT,
DISPLAY LIGHT LIGHT OFF
or DISPLAY LIGHT ON.
6. Press POOL or SPA to exit the User Setup mode.
7.6 Operating the Heater
To Turn on Pool Heat:
1. Press
2. The control unit displays
NOTE: The default setting for pool temperature is
3. Press Up or Down to change temperature set
NOTE: After 5 seconds of inactivity, the new
4. When the water temperature falls to 1° below the
To Maintain Pool Heat (optional Relay and Wiring
If connected, the Maintain Heat mode monitors the pool water
temperature 24 hours a day by turning the pool pump on and
sampling the water temperature. When the water temperature
drops below the programmed temperature set point, the
controller automatically starts heating the pool.
1. Press POOL.
2. Press MENU.
3. Press Down to display:
POOL.
SET: ° with the current
temperature setting.
80°F (26°C).
point.
temperature will be stored as the set point.
temperature setting, the controller starts the heater.
The LED is red to indicate the pool is currently
heating
Required)
.
Page 30
MAINTAIN POOL HEAT
Press MENU.
4.
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
Green LED lights and the control unit displays
SET: ° with the current temperature setting.
5. Press Up or Down to change temperature set
point.
NOTE: After 5 seconds of inactivity, the new temperature will
be stored as the set point.
To Turn on Spa Heat:
1. Press SPA.
2. The control unit displays
SET: ° with the current
temperature setting.
NOTE: The default setting for spa temperature is
102°F (38°C).
3. Press Up or Down to change temperature set
point.
GAS HEATER IS OFF PRESS POOL OR SPA.
7.7 Temperature Set Point Lock
Once you have programmed pool temperature and spa
temperature set points, you can lock them so that they
may not be changed inadvertently.
To Lock Temperature Set Point:
1. Press POOL to lock pool temperature set point.
SPA to lock spa temperature set point.
Press
2. Press and hold Up and Down at the same time for
5 seconds.
The unit displays:
To Unlock Temperature Set Point:
1. Press POOL or SPA to unlock either set point.
2. Press and hold Up and Down at the same time for
5 seconds.
The unit displays:
SET POINT LOCKED.
SET POINT UNLOCKED.
NOTE: After 5 seconds of inactivity, the new
temperature will be stored as the set point.
4. When the water temperature falls to 1° below the
temperature setting, the controller starts the heater.
The LED is red to indicate the spa is currently
heating
To Maintain Spa Heat (optional):
.
If connected, the Maintain Heat mode monitors the pool water
temperature 24 hours a day by turning the pool pump on and
sampling the water temperature. When the water temperature
drops below the programmed temperature set point, the
controller automatically starts heating the spa.
1. Press SPA.
2. Press MENU.
3. Press Down to display:
MAINTAIN SPA HEAT
Press MENU.
4.
Green LED lights and the control unit displays
SET: ° with the current temperature setting.
5. Press Up or Down to change temperature set
point.
NOTE: After 5 seconds of inactivity, the new
temperature will be stored as the set point.
7.8 Shutting Down the Heater
Refer to the Lighting and Shutdown Instructions label on
the inside lid panel of the heater (Figure 29).
Complete shutdown instructions are as follows:
1. Set temperature thermostat controls to their lowest
setting and turn off the controller. Make sure the
display shows OFF.
2. Turn off all electrical power to the heater at the
junction box.
3. Remove the top panel of the heater.
4. Turn the gas valve control switch to OFF.
5. Shut off the external gas supply valve to the
heater.
6. Replace the top panel.
To Turn the Heater Off:
When the control panel is OFF, the screen displays:
®
die line does not print
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
(A) This appliance does not have a pilot light. It is equipped with an ignition device which automatically lights the heater. Do NOT try to light the
burners by hand.
(B) BEFORE OPERATING, smell all around the appliance for gas. Be sure to smell next to the floor because some gas is heavier than air and
will settle on the floor.
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the Fire Department.
(C) Use only your hand to activate the gas control switch. Never use tools. If the switch will not move by hand, do not try to repair it. Call a
qualified service technician. Force or attempted repair may result in fire or explosion.
(D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to
replace any part of the control system which has been under water.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on
this label.
2.* Set the thermostat to lowest setting and turn
appliance switch to OFF.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition
device which automatically lights the heater.
Do not try to light the burners by hand.
5. Remove the top panel.
6. Turn gas control switch to OFF position
7. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the
safety information above on this label. If you
don't smell gas, go to next step.
8. Turn gas control switch to ON position.
POUR VOTRE PROPRE SÉCURITÉ LISEZ CECI AVANT D’UTILISER LE CHAUFFE-EAU
AVERTISSEMENT
(A) Cet appareil n’est pas muni d’une veilleuse. Il est muni d’un appareil d’allumage qui déclenche le chauffe-eau automatiquement. Ne pas
esssayer d’allumer les brûleurs à la main.
(B) AVANT DE METTRE EN MARCHE, assurez-vous qu’il n’y a aucune odeur de gaz autour de l’appareil. Assurez-vous qu’il n’y a aucune
odeur de gaz près du plancher, car certains gaz sont plus lourds que l’air et on pour effet de s’accumuler au plancher.
- Ne pas essayer de mettre en marche quelque appareil que ce soit.
- Ne touchez à aucun interrrupteur électrique. Ne pas faire usage d’un appareil téléphonique dan votre édifice.
- Contactez immediatement à partir du téléphone d’un voisin votre fournisseur de gaz. Suivez ses directives
- Si vous ne pouvez pas joindre avec votre fournisseur de gaz, appelez le service des incendies.
(C) Utilisez seulement votre main pour opérer le bouton de la commande de gaz. Ne jamais utiliser un outil. S’il est impossible d’opérer le
bouton à la main, n’essayez pas de le réparer. Appelez un technicien de service qualifié. L’utilisation d’une force quelconque peut avoir pour
résultat un feu ou une explosion.
(D) Ne pas utiliser cet appareil si une pièce quelconque a ete submergé. Contactez immediatement un technicien qualifié afin de faire examiner
l’appareil et faire remplacer toute piece du système de contrôle ainsi que toute commande de gaz qui aurait été submergé.
1. ARRÊTEZ ! Lisez les directives de sécurité ci-dessus sur cette
étiquette.
2.* Réglez le thermostat au plus bas et mettez la commande de
l’appareil à la position OFF .
3. Éteignez toute alimentation électrique de l’appareil.
4. Cet appareil est muni d’un dispositif d’allumage qui met le
chauffe-eau en marche automatiquement. Ne pas essayer
d’allumer les brûleurs à la main.
5. Enlevez le panneau supérieure.
6. Tournez l’interrupteur de commande de gaz jusqu’à la position ON.
7. Attendez pendant cinq (5) minutes afin que le gaz se dissipe.
8. Tournez le l’interrupteur de commande de gaz jusqu’a la position OFF.
9. Replacez le panneau supérieure.
10. Mettez l’appareil sous tension.
Assurez-vous qu’il n’y a aucune odeur de g
du plancher. S’il y a une odeur de gaz ARRÊTEZ-VOUS ! Suivez
l’étape « B » ci-dessus. S’il n’y a pas d’odeur de gaz, procédez à
la prochaine étape.
If you do not follow these instructions exactly, a fire or explosion may result,
causing property damage, personal injury, or death.
WHAT TO DO IF YOU SMELL GAS
TO TURN
9. Replace the top panel.
10. Turn on all electric power to appliance.
11.* Set thermostat to desired setting and switch
appliance from OFF to either POOL or
SPA.
12. If the appliance will not operate, check that
the filter pump is on, the filter is clean and
water is flowing to the pool. Otherwise,
follow the instructions "To Turn Gas
Off” and call your service technician
or gas supplier.
GAS CONTROL
SWITCH IN
“OFF” POSITION
Si vous ne suivez pas ce directives à la lettre, un incendie ou explosion peut en
être le resultat. Ceci causera des dommages aux biens des blessures personnelles
ou la mort.
QUOI FAIRE S’IL Y A UNE ODEUR DE GAZ
MODE D’EMPLOI
11.* Réglez le thermostat comme désiré et tournez le bouton de
commande de la position OFF à la position POOL ou
SPA .
12. Si l’appareil ne se met pas en marche, assurez-vous que la
pompe du filtre fonctionne, que le filtre soit propre et qu’il y a
débit d’eau vers la piscine. Autrement suivez les direc-
un
tives.
COMMANDE DE
GAZ À LA
az, même au niveau
POSITION “OFF”
GAS OFF
(1) * Set the thermostat to
lowest setting and switch
appliance to OFF.
(2) Turn off all electrical
power to the appliance if
service is to be performed.
(3) Turn gas control switch
to OFF positition.
(4) Replace top panel.
* See manual for details of
operation and thermostat control.
INTERRUPTION DE
L’ALIMENTATION
EN GAZ
(1) * Règlez le thermostat au
plus bas et mettre le bouton de
commande à OFF.
(2) Interrompez toute alimentation électrique a l’appareil si on
doit faire de l’entretien ou
réparation.
(3) Tournez l’interrupteur de
commande de gaz jusqu’à la
position OFF.
(4) Remplacez le panneau
supérieure.
* Voir le manuel pour les détails
concernant l’opération du contrôle de
thermostat.
Page 31
H0415400 REV C
Figure 29. Lighting and Shutdown Instructions Label on Top Panel
Page 32
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
Section 8. Maintenance
WARNING
Do not try to operate the heater if the water
temperature is below 40 °F (4°C)
If the heater is not going to be used for an exended period
of time and in colder climates, shut it down completely
(see Section 7.8, Shutting Down the Heater and refer to
the Lighting and Shutdown label inside the top panel of
the heater).
8.1 Winterizing
In areas where freezing temperatures occur in winter
and the pool or spa will not be used, the pool should be
winterized by a qualied pool service technician:
To Winterize Your Heater:
1. Turn off the electrical supply and the main gas
supply to the heater.
2. Remove the heater access panel.
3. Turn off gas supply to the heater following the
shut-down instructions. (See Section 7.8 in this
manual and/or shut-down instructions inside the
top of the heater).
4. Remove the drain plug from the inlet/outlet header
and completely drain the heater before the rst
frost.
5. After all water has drained from the heater, check
for mineral buildup in the openings.
6. Inspect the gasket on the drain plug. Store the
drain plug in a safe place for winter.
7. Cover the vent grill with plastic so that snow
will not accumulate and freeze in the combustion
chamber.
8. Remove and drain the pressure switch tubing.
COPPER
TUBING
To Start Up Your Heater:
1. Reinstall the drain plug.
2. Uncover the vent grill.
3. Make sure power is supplied to the pump.
4. Turn on the lter pump and circulate water
through the heater for 5 minutes. Check for leaks
while circulating.
5. Turn on the main gas supply to the heater at the
gas cock outside the heater jacket.
6. Turn on the heater according to the instructions
in Section 7.2 or refer to the label inside the top
panel of the heater (see Figure 29).
gases which could result in severe injury, or death.
The heater is designed and constructed to provide long
performance life when installed and operated properly
under normal conditions. Periodic inspections, especially
at spring start-up, are important to keep your heater
running safely and efciently through the years. Zodiac
Pool Systems, Inc. recommends that the homeowner
inspect the heater on a regular basis (especially after
abnormal weather conditions), and arrange to have a
professional inspection at least once a year by a qualied
service technician.
WARNING
For your safety, when starting the heater, keep your
head and face away from the exhaust grill opening and
blower inlet grill to prevent any risk of personal injury.
Make sure all doors/panels are securely in place and
stand back from the heater.
Figure 30. Pressure Switch Copper Tubing
8.2 Spring Start-up
When winterized, the heater should be reassembled by a
qualied professional technician in the Spring.
Guidelines for Homeowner Inspection:
WARNING
Donotstoreorusegasolineorotherammable
vapors, liquids or chemicals in the vicinity of this or any
other appliance.
inspect the heater and replace any part of the control
system and any gas control which has been under
water.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 33
1. Keep the top of the heater, under the heater,
and surrounding area clear of all debris and
combustible materials such as paper, leaves, etc.
2.
If there is a pressure relief valve, check for
corrosion in and around the valve. If there is
corrosion, turn off the lter pump and replace the
pressure relief valve.
3. Once a year check that water is running freely
through the pressure relief valve. To check, turn on
the lter pump and lift the release lever on the top
of the valve.
4. Be sure combustion air and ventilation openings
are not blocked.
Guidelines for Professional Inspection:
1. Check for loose or broken wires and terminal
connections.
2. Check the water pressure switch by turning the
lter pump off and on several times. The burner
should go off immediately after the pump stops.
The fan will continue to run for 45 seconds after
the burner shuts down. An ignition sequence
should start shortly after the pump is turned back
on.
3. Conduct an inspection of the TRV once a year.
4. Inspect the electrical controls, specically:
a. High limit switches.
b. Water pressure switch.
c. Automatic gas valve.
d. Power interface/Temperature control.
e. Vent temperature limit switch.
f. Control circuit fuse.
g. Ignition control.
h. Air pressure switch.
5. Inspect the inlet grill at the blower for blockage,
leakage, and corrosion.
6. Inspect the combustion blower for damage.
7. Conduct a normal operating cycle and observe
that the sequence proceeds as intended.
8. If the heater is equipped with a pressure relief
valve, clean any accumulated corrosion and make
sure that water runs freely when lever is lifted.
9. Inspect the outside of the combustion chamber
and blower for corrosion and indication of
improper operation.
10. Regularly inspect electrical controls for
deterioration. Repair and replace as necessary.
11. Visually check the main burner ame. To obtain a
good line of sight, remove the user interface from
the top panel of the heater (see Figure 30).
NOTE: If heater top panel has been reversed with water
connections to the left of the user interface control
panel, remove heater top to view sight glass.
View Port
Flame
Figure 31. Remove User Interface to View Flame
Section 9. Troubleshooting
9.1 Common Problems
Zodiac Pool Systems, Inc. strongly recommends that you
call a qualied service technician to perform all service
and repairs on the heater. To locate a licensed or qualied
technician or independent service company, check your
local yellow pages or visit:
com, and click on Dealer Locator.
www.zodiacpoolsystems.
Page 34
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
The following table lists some of the most common problems when running the heater. Most problems occur when the
heater is started for the rst time after installation or at spring start-up.
SymptomPossible CauseRemedy
Pump not operating• No power.
• Pump defective.
• Incorrectly wired.
• Time clock settings not synchronized with
actual time.
Unstable combustion-
(1) heater turns off and on
(2) heater ignites slowly
(3)ameliftsandgoesout
(4)shortyellowstreakedame
Not enough heat
(1) heater is slow to heat up
(2) heater not maintaining set
temperature
Heater pounding or knocking• Waterowthroughheatertoolow.
Low temperature rise• Low water temperature.
• Wrong gas.
• Lean fuel/air mixture— low supply
pressure.
• Lean fuel/air mixture— too much
combustion air.
• Rich fuel/air mixture— high manifold
pressure.
• Rich fuel/air mixture— too little combustion
air.
• Incorrect gas valve offset pressure.
• Heater size inadequate.
• Filter pump not running long enough.
• Failed Thermal Regulating Valve (TRV).
• Heater plumbed backwards.
• Check circuit breakers and power source.
• Replace the pump.
• Recheck wiring.
• Check time clock setting.
• Make sure the gas supply matches the gas type
indicated on the rating plate.
• Correct gas supply pressure to 4.0 “ W.C.
• Increase offset gas pressure. Rotate adjustment
screw clockwise.
• Correct gas supply pressure to 4.0 “ W.C.
• Decrease offset gas pressure. Rotate adjustment
screw counter-clockwise.
• Check offset pressure is set to —0.2” W.C. If this is
set properly, connect manometer to blower throat and
gas valve port to obtain differential. Make sure the
• Heater is condensing. Flue product moisture will
condense at the start-up until the heater water
temperature reaches the normal operating conditions.
Igniterlightsbutdoesnotre• Gas valve is not ON.
• Air in gas line.
• Gas valve failed.
• No power to gas valve.
• Low gas pressure.
• High burner throat pressure.
• Faulty or broken Thermal Flow Regulator.
• Correct the plumbing.
• TRV failure.
• Flip the switch to “on” position.
• Cycle ignition sequence until air is out of the gas line.
• Replace gas valve.
• Check controls for proper operation.
• Check supply pressure.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
ENGLISH
Page 35
9.2 Service Diagnostic Messages
The controller monitors several functions of the heater. In the event of a malfunction, the controller will display a
FAULT message. The following table lists the Heater Service Messages along with potential causes and remedies.
Fault MessagePossible CauseRemedy
FAULTPUMP
NO FLOW
FAULTHIGH LIMIT
FAULTFUSELINK/FIELD
FAULTCHECK IGNITION STEPS
FAULTSHORTED H2O SENSOR
or
FAULTOPEN WATER SENSOR
• Statusmessageindicatingthelter
pump is currently turned OFF when the
heater system programmed in Maintain
Temp mode.
• Pump is not running.
• Low pump pressure.
• Pressure switch fault.
• Variable speed pump set too low.
• Water temperature in heater exceeds
the internal limit.
• Limit switch fault.
• Temperature control thermostat failure
• Vent temp limit fault
(240°C- Marked with red paint)
• Broken, split, pinched or disconnected
air pressure switch.
• Fan not operating.
• Fan running slow or premature fan
failure.
• Airowrestrictedatintakeordischarge.
• Broken igniter.
• Low gas supply pressure.
• Noameatburners.
• Faulty wiring or connection.
• Failed water temperature sensor.
• No Service Required. This is normal when the control
is in a Maintain Temp mode.
• Check breakers and power source, recheck wiring, set
time clock and current time.
• Check for proper clearances around heater and for
adequate room ventilation if enclosed. Inspect for
blockageorrestrictionatdischargeofue.
• Cleanlter.
• Check the circuit.
• Check ignition control LED codes (see Section 9.3,
Ignition Control LED Service Codes).
• Identify and repair incorrect supply pipe size or pipe line
blockage.
• Identify and correct loose wiring connections, or
problems with igniter, gas valve, or ignition control.
• Refertoqualiedservicepersonnel.
• Inspect water temperature sensor wiring.
• Ensure sensor is connected correctly into the PCB.
• Replace water temperature sensor.
• Refertoqualiedservicepersonnel.
9.3 Ignition Control LED Service Codes
In addition to service diagnostic messages, the ignition controller has an LED light that ashes to indicate various
ignition control faults. The table below lists the LED codes and the corresponding fault description. To diagnose
possible cause and remedy, refer to Section 9.2, Service Diagnostic Messages.
LED CodeFault Description
The LED light is on
continuously.
LED single flash.Air flow fault.
LED double flash.Flame exists when there is
LED triple flash.Ignition lockout (heater has
Ignition Control Fault. Refer to
qualified service personnel.
NO call for heat. Refer to
qualified service personnel.
cycled three (3) times and has
locked out after the third try).
Page 36
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
Section 10.
Professional Service
and Maintenance
WARNING
SERVICING SAFETY
Service procedures can be hazardous because
they involve fuel gas, electricity, moving parts and
procedures which require testing or temporary bypass
of safety controls. For this reason, the heater must
The heater incorporates unique design features.
Incorrect service of this heater can result in personal
injury or damage to property. To avoid such hazards,
theheatermustbeservicedonlybyaqualiedprofessional service technician.
6. Connect a hose between the third part of the tee to
the negative side of the manometer.
7. Start the heater and record the gas offset pressure
with the heater running and the sealing cap rmly
in place.
8. If the offset is incorrect, adjust the gas valve until
the correct pressure is obtained, see Table 5.
9. Remove the tees and replace the hoses to the vent
port at the gas valve and the other hose to the gas
manifold port at the gas valve.
IMPORTANT MAINTENANCE NOTE
We recommend that before each pool session, the
Thermal Regulator Valve (TRV) be inspected for
proper operation and replaced if there are signs of
scaling or corrosion.
The TRV ensures the heater operates at it’s optimal
Zodiac Pool Systems, Inc. strongly recommends that you
call a qualied service technician to perform all service
and repairs on the heater. To locate a licensed or qualied
technician or independent service company in your area,
contact Zodiac Technical Support at:
1-800-822-7933 (USA)
1-888-647-4004 (Canada), or
www.zodiacpoolsystems.com -Dealer Locator tab
Before servicing the heater:
• Conrm that the heater control is set to either
POOL or SPA
• Conrm the temperature set point for either Pool or
Spa is set high enough to make the heater operate
given the current water temperature.
10.1 Gas Pressure Offset Test
1. Connect a tee to the hose from the fan inlet to the
gas valve vent port.
2. Connect a shorter hose to the opposite side of the
tee to the gas valve vent port.
3. Connect the third part of the tee with a hose to the
positive side of the manometer.
4. Connect a second tee to the gas manifold pressure
port.
5. Connect a short hose to the opposite side of the tee
to the gas manifold pressure port.
11.1 Ordering Information
To order replacement parts for the JXi pool and spa heater,
contact Zodiac Techical Support at:
1-800-822-7933 (USA)
1-888-647-4004 (Canada), or
www.zodiacpoolsystems.com
NOTE To identify the correct part, you will need to know the
model number, serial number and type of gas when
applicable. This information can be found on the rating
plate sticker, which is located inside the heater on the
outside of the combustion chamber.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
11.2 JXi Major Components
Cabinet
See Section 11.3
ENGLISH
Page 37
Water System
See Section 11.5
Heat System
See Section 11.4
Electrical System
See Section 11.6
Page 38
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
11.3 Cabinet Assembly Spare Parts List and Exploded Parts Diagram
12High Limit Temperature Sensors KitR0592300R0592300R0592300R0592300
Page 43
13Igniter KitR0457502R0457502R0457502R0457502
* Key No refers to Section 11.6.2 Electrical System Exploded Parts Diagram
11.6.2 Electrical System Exploded Parts Diagram
11
13
5
8
6
7
9
12
1
3
4
10
2
Page 44
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
Section 12. Water Chemistry
Proper Water Balance is the key to the enjoyment of your
pool or spa experience and to the long life of your heater.
The pH of your pool or spa’s water is one of the factors
that has the most impact on indicating how properly
balanced the water is. The other factors are: temperature,
total alkalinity, calcium hardness and total dissolved
solids. Cold water is typically more acidic (corrosive),
while hot water that is not properly balanced could lead
to a scale forming (basic) condition. While the heater is
in operation, if the PH is allowed to rise above 7.8 and
the calcium hardness and total alkalinity are not properly
maintained; calcium in the water could lose solubility,
coating the copper tubes inside the heat exchanger.
This will restrict the ow of water resulting in reduced
efciency and possible damage to the heater.
If the pH is allowed to drop below 7.2, and the alkalinity
is not properly maintained, the water will become more
acidic. Acidic water has a tendency to dissolve metal
components in the pool plumbing with the copper heat
exchanger in the heater being a prime target.
PH, Total Alkalinity (TA), temperature, Calcium Hardness
and Total Dissolved Solids (TDS) play a role in whether
the water is either corrosive or scale forming. These
factors are combined in the Langelier Saturation Index,
which is a method for determining whether or not water is
properly balanced. See Table 7 below.
Table 7. Water Saturation Index
NOTE Acceptable “saturation Index” is between +0.5 and
-0.5. When dealing with a cosmetic surface the
index should be maintained between +0.3 and -0.3.
A positive value is more acceptable than a negative
value.
The practice of putting tablet-based sanitizers in the
skimmer basket can produce heavily chlorinated water
with very low pH in contact with metal parts of the heater
that can cause serious damage. Practices like this should
be discontinued and the use of oating sanitizer dispensers
and check valves as backow preventers with inline
erosion-style feeders should be encouraged.
If acidic conditions are present, there could be signs of
metal in the pool water that could cause staining on the
oor of your pool. This might manifest itself in the form
of brown stains on the nish of your pool bottom or pool
water discoloration. Your local pool dealer can test for
metals in your water or can provide you with a test kit.
Every effort should be made to maintain the water balance
of your pool or spa in the proper range. Ignoring this very
important component of your pool’s water chemistry can
make the water less enjoyable to bathe in and result in
permanent damage to your heater and/or complete failure
of individual components.
Zodiac Pool Systems does not warrant heat exchangers
damaged by corrosive water issues or from the build-up
of calcium in the heater’s heat exchanger. Any questions
regarding proper water balance can be directed to our
product support line at Zodiac or to your local pool dealer.
Saturation Index = pH + AF + CF + TF -12.1
A-Factor=(AF), C-Factor=(CF), T-Factor=(TF)
Total AlkalinityCalcium HardnessTemperature
A-FactorC-FactorT-Factor
PPM
5= 0.75= 0.932=0.0
25=1.425= 1.037=0.1
50=1.750= 1.346=0.2
75=1.975= 1.553=0.3
100= 2.0100= 1.660=0.4
150= 2.2150= 1.866=0.5
200= 2.3200= 1.976=0.6
300= 2.5300= 2.184=0.7
400= 2.6400= 2.294=0.8
800= 2.9800= 2.5105 =0.9
1000 = 3.01000=2.6128 =1.0
A saturation index of 0 is perfectly balanced
A negative saturation index has corrosive tendencies
A positive saturation index has scaling tendencies
A saturation index of +0.3 or -0.3 should be used for visible,
cosmetic pool surfaces.
Factor
Value
PPM
Factor
Value
°F
Factor
Value
NOTE: The Thermal Regulator Valve (TRV) is an indicator of
how well the water chemistry is being maintained.
The TRV Should be inspected before each
pool season to ensure it is clean and operating
properly. If you see signs of calcium buildup or
corrosion the TRV should be replaced and your
water balanced.
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
NOTES
ENGLISH
Page 45
Page 46
ENGLISH
®
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
Jandy
NOTES
®
Jandy
Pro Series, JXi™ Gas-Fired Pool & Spa Heater | Installation & Operation Manual
NOTES
ENGLISH
Page 47
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.ZodiacPoolSystems.com
ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.