Jandy ePump Installation Manual

Page 1
Installation Data
Installation Man u al
ePump
TM
Variable Speed Pump User Interface
PRESS PRESET OR MENU
12:00AM PUMP IS OFF
2
ePUMP
3
4
H0311300A
WARNING
Page 2
Page 3
Table of Contents
Page 3
Section 1. Important Safety Instructions ........ 4
Section 2. Installation of the User Interface ... 6
2.1 Introduction ......................................................... 6
2.2 The User Interface Panel .................................... 6
2.3 The User Interface Components ......................... 6
2.4 Installation of the Backplate onto an
Electrical Box ...................................................... 6
2.5 Installation of the Backplate on a Flat Wall ......... 7
2.6 Connection to the Jandy ePump
Speed Pump ....................................................... 7
2.7 Jandy ePump™ Variable Speed Pump Switch
Settings ............................................................... 7
2.8 Connection to Remote Contacts ......................... 8
2.9 Remote Operation ..............................................8
2.10 Remote Closure 4 Behavior ................................ 8
TM
Variable
Section 3. User Operation ................................ 9
3.1 OFF Mode ........................................................... 9
3.2 RUN Mode .......................................................... 9
3.3 Manual Start and Stop ........................................ 9
3.4 Pump Speed Setting ........................................... 9
3.5 Timeclock Setup and Operation........................10
Section 5. User Set Up Options ..................... 13
5.1 Setting Time-of-Day .......................................... 13
5.2 Labeling Presets ............................................... 13
5.3 General Labels .................................................14
5.4 Custom Labels .................................................. 14
5.5 Display Light Control ......................................... 14
5.6 Language Selection .......................................... 14
5.7 Run Duration (Presets 3 and 4 Only) ................ 14
Section 6. Menu Flow Chart ........................... 15
Section 4. Service Setup Options ................. 11
4.1 Entering Service Setup ..................................... 11
4.2 Minimum and Maximum Pump Speeds ............ 11
4.3 Load Defaults .................................................... 11
4.4 Last Fault .......................................................... 12
4.5 Priming Speed and Duration ............................. 12
4.6 eStar Speed ...................................................... 12
4.7 Pump Freeze Protect Operation ....................... 12
4.8 Selecting Pump Type ........................................ 13
EQUIPMENT INFORMATION RECORD
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL
FILTER MODEL
HORSEPOWER
SERIAL NUMBER
CONTROLLER MODEL SERIAL NUMBER
NOTES:
Page 4
Page 4
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
LIRE LA NOTICE TECHNIQUE.
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing
and using this electrical equipment, basic safety precautions should always be followed, including the following:
DANGER
To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub. Never operate a spa or hot tub if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly.
WARNING
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of the body. The effects of hyperthermia include: 1) unawareness of impending danger; 2) failure to perceive heat; 3) failure to recognize the need to exit spa; 4) physical inability to exit spa; 5) fetal damage in pregnant women; 6) unconsciousness resulting in a danger of drowning.
WARNING
To Reduce the Risk of Injury -
a) The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and
104°F (40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of
pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
c) Before entering a spa or hot tub, the user should measure the water temperature with an accurate
thermometer since the tolerance of water temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with
the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa or hot tub since some medication
may induce drowsiness while other medication may affect heart rate, blood pressure, and circulation.
Page 5
Page 5
WARNING
People with infectious diseases should not use a spa or hot tub.
To avoid injury, exercise care when entering or exiting the spa or hot tub.
Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub.
Water temperature in excess of 100°F (38°C) may be injurious to your health.
Before entering a spa or hot tub measure the water temperature with an accurate thermometer.
Do not use a spa or hot tub immediately following strenuous exercise.
Prolonged immersion in a spa or hot tub may be injurious to your health.
Do not permit any electric appliance (such as a light, telephone, radio, or television) within 5 feet (1.5m) of a spa or hot tub.
The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
Water temperature in excess of 100°F (38°C) may be hazardous to your health.
AVERTISSEMENT
Les personnes atteintes de maladies infectieuses ne devraient pas utiliser une cuve de relaxation.
Pour éviter des blessures, user de prudence en entrant dans une cuve de relaxation et en sortant.
Pour éviter l’évanouissement et la noyade éventuelle, ne prendre ni drougue ni alcool avant d’utiliser une cuve de relaxation ni quand on s’y trouve.
Les femmes enceintes, que leur grossesse soit con rmée ou non, devraient consulter un médecin avant d’utiliser une cuve de relaxation.
Il peut être dangereux pour la santé de se plonger dans de l’eau à plus de 38°C (100°F).
Avant d’utiliser une cuve de relaxation mesurer la témperature de l’eau à l’aide d’un thermomètre précis.
Ne pas utiliser une cuve de relaxation immédiatement après un exercice fatigant.
L’utilisation prolongée d’une cuve de relaxation peut être dangereuse pur la santé.
Ne pas placer d'appareil électrique (luminaire, téléphone, radio, téléviseur, etc) à moins de 1.5m de cette cuve de relaxation.
La consommation d’alcool ou de drogue augmente considérablement les risques d’hyperthermie mortelle dans une cuve de relaxation.
Il peut etrê dangereux pour la santé de se plonger dans de l’eau à plus de 38°C (100°F).
WARNING
To avoid injury ensure that you use this control system to control only packaged pool/spa heaters which have built­in operating and high limit controls to limit water temperature for pool/spa applications. This device should not be relied upon as a safety limit control.
Attention installer: Install to provide drainage of compartment for electrical components.
SAVE THESE INSTRUCTIONS
Page 6
Page 6
Section 2. Installation of the User
Interface
2.1 Introduction
This document provides general instructions to install the user interface for use with the Jandy ePump pump. The user interface can be mounted to an electrical gang box (single, double, or triple) or to a flat wall.
The instructions have been written with safety as the priority, and must be followed exactly. Read through the instructions completely before starting the procedure.
2.2 The User Interface Panel
The user interface panel provides both timed and manual speed controls for the Jandy ePump
Four speed presets are directly available on the panel, while four (4) additional presets may be accessed via the MENU key.
The up and down keys are used to adjust the pump speed. Speed is saved as it is adjusted. No further action is required to save the new speed setting after adjustment. The selected speed can be saved and assigned to one of the speed buttons.
As shown in Figure 1, preset speed " the "eStar" feature. Hence, it is intended to be assigned an energy-efficient filtration speed, as determined by the installer.
LCD Display
LED Lights
PRESS PRESET OR MENU 12:00AM PUMP IS OFF
2
TM
ePUMP
MENU
TM
variable speed
Variable Speed Pump.
" is assigned to
Up/Down
Arrow Keys
4
3
Additional materials are required for the installation of the user interface and must be supplied by the installer:
1. A cable to connect the pump to the remotely mounted user interface, minimum size of 22 AWG (Jandy part number 4278). This cable will need to have four (4) conductors and be able to handle 24V control signals. This cable should be rated for the particular installation (for example: outdoor, UV resistant, direct burial, etc.) and should conform to all applicable codes and regulations. (A suitable cable is included in the JEP Series ePump water pumps.)
2. A minimum of two (2) fasteners to mount the user interface back plate to a wall or electrical box. The fasteners should be suitable for the surface where the user interface is to be remotely mounted.
3. A high-voltage
disconnect switch, as required by the
National Electric Code (NEC), within line of sight of the pump.
2.4 Installation of the Backplate onto an Electrical Box
CAUTION
Do not expose the user interface to direct sunlight. Too much direct sunlight will darken the LCD screen, and it will no longer be readable.
1. Turn off the pump at the control panel.
2. Turn off all electrical power to the pump at the main junction box or at the circuit breaker providing electrical power to the pump.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the ePump™ electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death.
eStar Button
Menu Button
Figure 1. Jandy ePump
TM
Variable Speed Pump
Preset Speed
User Interface Panel
2.3 The User Interface Components
The ePump™ user interface assembly (See Figure 2) contains the following components:
1. User Interface
2. Mounting Gasket
3. Backplate
4. Round Seal
5. Six (6) Screws
6. Plastic Film
Buttons
3. Drill out the plastic film covering the backplate screw holes. See Figure 2.
4. Secure the backplate to the box using the screws that came with the electrical box.
Screws
Backplate
Round Seal
Breakout tabs
(not supplied with kit)
Screws (6)
Gasket
Plastic Film
User Interface
Figure 2. User Interface Components
Page 7
Page 7
5. Drill out a ½" hole and insert the round seal supplied with the kit. A remote cable will run through the middle hole of the backplate and into the electrical box.
2.5 Installation of the Backplate on a Flat Wall
CAUTION
Do not expose the user interface to direct sunlight. Too much direct sunlight will darken the LCD screen, and it will no longer be readable.
1. Turn off the pump at the control panel.
2. Turn off all electrical power to the pump at the main junction box or at the circuit breaker providing electrical power to the pump.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the ePump™ electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death.
3. A minimum of two (2) fasteners (installer supplied) are required when installing to a flat wall to hold the user interface securely.
4. The backplate has ten (10) mounting holes to choose from. Only drill out the plastic film from the holes to be used. See Figure 2.
5. Mark the hole locations on the wall and use the fastener to secure the backplate to the wall.
6. At the bottom of the backplate, cut the two (2) tabs out with an appropriate tool, such as a carton cutter or an exacto knife, and route the cable through the open channel.
2.6 Connection to the Jandy ePumpTM Variable Speed Pump
The following steps provide the procedure for installing the user interface to a Jandy ePump™ variable speed pump.
1. Turn off all switches and the main breaker that supplies power to the pump.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the pump electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death.
2. Remove the cover of the pump junction box.
3. Feed the RS-485 cable into the  tting.
NOTE The user interface uses a four-wire RS-485 interface
to communicate with the ePump™.
4. Unplug the RS-485 connector from the pump.
5. Attach the four (4) wires in the RS-485 cable to the RS-485 connector. Make sure the colors match the positions on the connector. See Figure 2.
6. Connect the RS-485 connector back into the pump.
7. Set the DIP switch settings for the pump controller with the 1 and 2 in the ON position and 3 and 4 in the OFF position. See Figure 3.
8. Turn on all switches and the main breaker feeding power to the pump.
9. Verify the operation of the controller. If the controller displays FAULT PUMP NOT CONNECTED, re-check the wiring and the DIP switch address setting on the pump.
User Interface (Rear View)
4-Position
DIP Switch
2 BLACK
3 YELLOW
1 RED
4 GREEN
RS485
54321
REMOTE CONTROL
4321
RS485 Cable
Jandy ePump¥
SW 1
SW 2
SW 3
SW 4
(Rear View)
Figure 3. Wiring the User Interface to the Jandy
ePump
TM
Variable Speed Pump
2.7 Jandy ePump™ Variable Speed Pump Switch Settings
For the ePump™, the 4-position dip switch is located at the rear of the pump, as shown in Figure 3.
This dip switch serves two functions, it determines what type of control will be used with the pump and it selects the pump address. The SW 1 (switch 1) and SW 2 are turned ON if the pump is to be controlled by a stand alone controller or OFF if the pump is to be controlled by the AquaLink AquaLink® PDA.
SW 1 SW 2 CONTROL
OFF OFF
ON OFF
OFF ON
AquaLink AquaLink® PDA
ON ON Stand Alone
The SW 3 and SW 4 are turned ON/OFF to select the Pump address.
SW 3 SW 4 PUMP No.
OFF OFF 1
ON OFF 2
OFF ON 3
ON ON 4
®
RS or
®
RS
Page 8
Page 8
2.8 Connection to Remote Contacts
The user interface allows speeds "" through "4" to operate via remote contact closures (switch or relay). Speed "4" operates differently than the other three. See Section 2.10, Remote Closure 4 Behavior.
1. Turn off all switches and the main breaker that supplies power to the ePump™.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the ePump™ electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death.
2. Connect one side of the remote contact closure to the COMMON terminal on J3 REMOTE CONTROL connector of the controller. See Figure 4.
3. Connect the other side of the remote contact closure to INPUT 1, INPUT 2, INPUT 3, or INPUT 4 terminal on J3 REMOTE CONTROL connector of the controller, depending on which speed is to be controlled.
4. Turn on all switches and the main breaker feeding power to the ePump™.
5. Verify the operation of the contact closures. If the correct speed is activated when the closure is activated, the ePump™ starts, and the message REMOTE ENABLED appears on the controller display.
NOTE When starting the pump via a remote closure, the
pump will first run at the priming speed for the priming duration, as set by the installer.
2.9 Remote Operation
Speeds activated via remote closures always override speeds that have been activated manually or via an internal timer program. When the pump is activated via a remote closure, the keypad is disabled and the message REMOTE ENABLED appears on the display.
2
REMOTE ENABLED
ePUMP
MENU
4
3
10:00AM RPM:1200
The controller will remain in this state until the contact is opened. When more than one (1) contact closure occurs, the highest speed will take priority.
2.10 Remote Closure 4 Behavior
The behavior of speed "4" differs from manual operation when operated via a remote contact closure. As during manual operation, the turn-on time of remote closure 4 is immediate, and occurs at the same time as contact closure (For example, see Section 2.8). The turn-off time, however, is delayed by 30 minutes.
In other words, when remote closure 4 is de-activated, the ePump™ will continue to run for 30 minutes, after which time the controller will turn off the ePump™. The delay may be manually interrupted by pressing any preset key.
Remote Contact Closure
INPUT 2
INPUT 3
INPUT 4
COMMON
J3
54321
INPUT 1
REMOTE CONTROL
input
common
YELLOW
GREEN
4321
RS485
BLACK
RED
Figure 4. Connection to Remote Contacts
2.10.1 Remote Closure 4 Application ­Booster Pump Support
The behavior of remote closure 4 may be used to allow an external timeclock fitted with a 20-minute “fireman’s switch” (e.g., Intermatic P/N 156T4042A) to properly control the ePump™ in conjunction with a booster pump.
Connection for Booster Pump Support:
1. Turn off all switches and the main breaker that supplies power to the ePump™.
WARNING
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the ePump™ electrical circuit before starting the procedure. Failure to comply may cause a shock hazard resulting in severe personal injury or death.
2. Install the normally-closed  reman’s switch to the timeclock assembly. (See timeclock manufacturer’s instructions for details.)
3. Connect the main timeclock contacts to the booster pump power input per the booster pump installation manual.
Page 9
Page 9
4. Connect one side of the  reman’s switch to the ePump™ Controller at J3 REMOTE CONTROL, COMMON.
5. Connect the other side of the  reman’s switch to the ePump™ controller at J3 REMOTE CONTROL, INPUT 4.
6. Set the timeclock to the desired on/off times.
7. Turn on all switches and the main breaker feeding power to the ePump™.
8 If the installation is working properly, the  reman’s
switch will open 20 minutes before the booster pump shuts down, the ePump™ will continue to run for 30 minutes, and the ePump™ Controller will display PUMP WILL REMAIN ON FOR XX:XX, where XX:XX is the time remaining until ePump™ shutdown.
Section 3. User Operation
3.1 OFF Mode
When the pump is off (not running), the controller displays PRESS PRESET OR MENU/00:00 PUMP IS OFF, where 00:00 is the time-of-day clock.
3.3 Manual Start and Stop
Up to eight (8) programmed speeds may be started from the controller. Manual operation of speeds "eStar" through "4" differs from manual operation of speeds "5" through "8".
NOTE When starting the pump, the pump will first run at the
priming speed for the priming duration, as set by the installer.
3.3.1 Speeds eStar through 4
To start the pump manually running at speeds "eStar" through "4", press button " desired speed. The associated LED will light red and the controller enters the RUN mode.
" through "4" corresponding to the
2:PRESET 2
10:00AM RPM: 1200
2
MENU
ePUMP
4
3
PRESS PRESET OR MENU
12:00AM PUMP IS OFF
2
ePUMP
MENU
4
3
3.2 RUN Mode
When the pump is running (not off), the controller displays N:LABEL/00:00 RPM:XXXX, where n:label is the number and label of the selected preset, 00:00 is the time-of-day clock, and xxxx is the pump speed.
2:PRESET 2
10:00AM RPM: 1200
To stop the pump, press the button again. The associated LED will extinguish and the pump and controller will return to the
OFF mode.
3.3.2 Speeds 5 through 8
To start the pump manually at speeds "5" through "8", press the MENU button. The controller displays SELECT PRESET/N:LABEL, where n:label is the number and label of the last selected preset "5" through "8".
Using the arrow keys, select the desired preset to activate, and then press MENU to enter RUN mode, starting the pump
running at the selected speed.
SELECT PRESET 5:PRESET 5
2
ePUMP
MENU
4
3
2
ePUMP
MENU
4
3
To stop the pump, press MENU. To exit without starting the pump, press any button "" through "4".
3.4 Pump Speed Setting
With the exception of preset "", the pump speed for each preset may be adjusted while the pump is running in that preset mode. Preset "" is reserved for the eStar function, and its speed is set by the installer.
Page 10
Page 10
To adjust the pump speed, the controller must be in the RUN mode. While in RUN mode, the controller displays the pump speed. Adjust the speed by pressing the up or down arrow keys. The speed is saved by the controller and will remain until changed again.
NOTE Pump speed is adjustable only within a certain range.
The minimum and maximum limits of the range are set by the installer.
2:PRESET 2 10:00AM RPM: 1400
2
ePUMP
MENU
4
3
3.5 Timeclock Setup and Operation
The controller allows the user to create timed pump programs on pump speeds (presets) "
" and "2". The two timers
operate independently of each other, and may overlap in time if desired.
3.5.1 Timeclock Setup
Start the desired speed, "" or "2". Press MENU. The controller enters the Timeclock setup mode. Using the arrow keys, select ON TIME and press MENU. Set the desired pump turn-on time using the arrow keys and press MENU. The time is stored. Select OFF TIME using the arrow keys and press MENU. Set the desired pump turn-off time using the arrow keys and press MENU. The time is stored.
Using the arrow keys, select TIMECLOCK. Select ENABLE using the arrow keys. The program is now enabled to run. Press the preset button ("" or "2") to return to the RUN mode.
2:PRESET 2 TIMECLOCK ENABLE
2
ePUMP
MENU
4
3
3.5.2 Timeclock Operation
When the pump is stopped, the associated green LED will illuminate, indicating a timeclock program is enabled for that speed.
If two (2) timed programs overlap, the program with the faster speed will take priority and run to completion. If the earlier-starting program is still active, it will resume operation. The program off times never change, i.e., they are not ‘pushed-out’ in time when programs overlap. Timeclock programs may be prematurely stopped by stopping the pump manually from the keypad. This override is active until the program start time is reached again, at which time the timed program will start the pump as programmed.
If the pump is started manually at a speed that has been programmed with a timer, the pump will be stopped by the timeclock at the programmed off time.
NOTE When starting the pump via a timed program, the
pump will first run at the priming speed for the priming duration, as set by the installer. If a program overlap occurs, the pump will immediately start at the program speed without priming first.
2:PRESET 2 TIMECLOCK ON TIME
2
ePUMP
MENU
4
3
3.5.3 Manually Overriding a Timer Program
Timeclock programs may be prematurely stopped by pressing the active preset key. This override is active until the program start time is reached again, i.e., for 24 hours, at which time the timed program will start the pump as programmed.
PRESS PRESET OR MENU
12:00AM PUMP IS OFF
2
ePUMP
MENU
4
3
Page 11
Page 11
3.5.4 Timer Overriding a Manual On
If the pump is started manually at a speed that has been programmed with a timer, the pump will be stopped by the timeclock at the programmed off time. A clock icon appears on the display when the timer has assumed control of the off
time.
Section 4. Service Setup Options
The service setup menu allows the installer to set various operating parameters, view fault history, and restore factory defaults.
Parameters that may be modified and set in the service setup menu include:
Priming speed and duration.
Minimum and maximum pump speeds.
"
" eStar speed.
Pump Freeze Protect operation.
4.1 Entering Service Setup
NOTE The ePumpTM user interface must be in the OFF
mode (all LED's lights must be off) before entering the user setup mode. While in setup mode the user
interface will return back to the (1) minute since the last key press.
OFF mode after one
4.2 Minimum and Maximum Pump Speeds
These speeds are considered global settings across the entire controller, and create the range of allowable speed that may be sent to the ePump™.
To set the minimum speed, from the service setup menu, select SET MIN LIMIT using the arrow keys. Press MENU. Using the arrow keys, set the minimum speed to the desired value. Press MENU to accept and store.
SET MIN LIMIT RPM: 600
2
ePUMP
MENU
To set the maximum speed, from the service setup menu, select SET MAX LIMIT using the arrow keys. Press MENU. Using the arrow keys, set the maximum speed to the desired value. Press MENU to accept and store.
4
3
To enter the service setup menu, press and hold MENU, then press and hold the "
" and preset "4" keys. Hold all three
(3) keys down for five (5) seconds. To exit, press any preset button.
PRESS PRESET OR MENU
12:00AM PUMP IS OFF
2
ePUMP
MENU
4
3
SET MAX LIMIT RPM: 3450
2
ePUMP
MENU
4
3
4.3 Load Defaults
To restore factory default settings to the controller, from the service setup menu, select LOAD DEFAULTS. Press MENU. Using the arrow keys, select YES. Press MENU to restore factory default settings.
LOAD DEFAULTS YES
2
ePUMP
MENU
4
3
Page 12
Page 12
4.4 Last Fault
This feature shows on the top display line, the most recent unique fault message and on the bottom display line, the second-to-last unique fault message. If there is no entry for a fault, the display will show “*----------------*” on the corresponding line. To select last fault, from the service setup menu select LAST FAULT. Press MENU.
NOTE The fault messages are stored in non-volatile
memory, and remain even with no power. To clear the fault history, press either arrow key.
SELECT SERVICE SETUP
LAST FAULT
2
ePUMP
MENU
4
3
4.5 Priming Speed and Duration
The ePump™ controller will command the ePump™ to operate at the priming speed for the priming duration specified (except during timer program overlaps or follow-on commands where the pump is not stopped before changing speeds). From the service setup menu, select PRIMING using the arrow keys. Press MENU.
To set priming duration, select PRIMING DURATION using the arrow keys. Press MENU. Using the arrow keys, set the priming speed to the desired value in minutes from 1 to 5 minutes. Press MENU to accept and store.
PRIMING DURATION MIN: 3
2
ePUMP
MENU
4
3
4.6 eStar Speed
The "" speed is intended to be used as an energy-efficient setting that can be easily called-up by activating the eStar preset speed from the keypad or remote closure. After this speed has been determined by the installer, the eStar preset may be set as follows: From the service setup menu, select SET ESTAR SPEED. Press MENU. Using the arrow keys, set the speed to the desired value. Press MENU to accept and store.
1:eSTAR RPM:1250
PRIMING DURATION MIN: 3
2
ePUMP
MENU
4
3
To set priming speed, select PRIMING SPEED using the arrow keys. Press MENU. Using the arrow keys, set the priming speed to the desired value. Press MENU to accept and store.
PRIMING SPEED RPM: 3450
2
ePUMP
MENU
4
3
2
ePUMP
MENU
4
3
4.7 Pump Freeze Protect Operation
When enabled to do so, the ePump™ controller monitors the temperature inside the pump and will activate the ePump™ at the eStar speed when the temperature approaches freezing. The run duration of the pump freeze protect operation is adjustable from 30 minutes to 8 hours, or may be disabled completely.
Page 13
Page 13
To set the pump freeze protect operation, from the service setup menu select PUMP FREEZE PROTECT. Press MENU. Using the arrow keys, set the duration to the desired value. To disable pump freeze protect, set the duration to 0:00. Press MENU to accept and store.
PUMP FREEZE PROTECT 1:05
2
ePUMP
MENU
4
3
Important Information on Freeze Protection
Freeze protection is intended to protect equipment and plumbing for short periods of freezing only. It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing. Freeze protection does not guarantee that equipment will not be damaged by extended periods of freezing temperatures or power outages. In these conditions, the pool and spa should be shut down completely (e.g. drained of water and closed for the winter) until warmer weather exists.
Section 5. User Set Up Options
NOTE The ePumpTM user interface must be in the OFF
mode before entering the user setup mode. While in setup mode the user interface will return back to the
OFF mode after one (1) minute since the last key
press.
When in setup mode, preset keys "" through "4" are used as ‘escape’ or exit keys while navigating the setup menu.
To enter the setup mode, press and hold the MENU button for five (5) seconds. The controller displays SELECT USER SETUP. Using the arrow keys, select the desired setup item to change.
5.1 Setting Time-of-Day
From the Setup menu, select SET TIME. Press the MENU button to display the currently-set time. Using the arrow keys, adjust to the desired time. Press MENU to save your setting.
SELECT USER SETUP SET TIME
2
ePUMP
MENU
4
3
The pump freeze protect run time may be interrupted by
pressing a preset key, as follows:
Pressing the key "" once overrides the pump freeze protect run time, pressing it twice turns off the pump. Pressing other preset keys will override the pump freeze protect run time and activate the selected preset speed.
PUMP FREEZE PROTECT 1: FILTRATION
2
ePUMP
MENU
4
3
4.8 Selecting Pump Type
This feature is preset by factory default. At this time, the ePump™ controller does not support other types of pumps.
5.2 Labeling Presets
The ePump™ controller comes from the factory with pre­programmed labels or names for the preset speeds. The labels may be changed as desired to suit your particular installation.
Two types of labels are provided by the controller:
General Labels - selected from a list
Custom Labels - created by the user
From the setup menu, select LABEL PRESET. Press the MENU button to display the currently selected Preset. Using the arrow keys, choose the preset to be changed. Press MENU to select. The controller displays SELECT LABEL TYPE. Select GENERAL or CUSTOM as desired using the arrow keys.
SELECT USER SETUP LABEL PRESET
2
ePUMP
MENU
4
3
Page 14
Page 14
5.3 General Labels
Using the arrow keys, select a general label from the list to assign to the Preset. Press MENU to assign the label to the Preset.
LABEL PRESET FILTRATION
2
ePUMP
MENU
4
3
5.4 Custom Labels
In the custom label mode, the controller displays a flashing cursor at the character position to be changed. Using the arrow keys, change the character as desired. Press MENU to accept the change and advance to the next character position. Press any preset key "" through "4" to return to the previous cursor position.
2 MIN TIMEOUT: Turn on display backlight, with automatic turn-off after two (2) minutes since the last key press.
SELECT USER SETUP DISPLAY LIGHT
2
ePUMP
MENU
4
3
5.6 Language Selection
From the setup menu, select LANGUAGE using the arrow keys. Press MENU. Using the arrow keys, select the desired language. Press MENU to save the selection.
SELECT USER SETUP LANGUAGE
LABEL PRESET 1:PRESET 1
2
ePUMP
MENU
4
3
Continue this procedure until the end of the label is reached. The new label is saved when MENU is pressed at the last
character position.
5.5 Display Light Control
The controller’s display is equipped with a backlight to aid viewing in low light conditions.
From the setup menu, select DISPLAY LIGHT. Press MENU. Using the arrow keys, select the desired operating mode for the display backlight:
LIGHT OFF: Turn off display backlight.
LIGHT ON: Turn on display backlight.
2
ePUMP
MENU
4
3
5.7 Run Duration (Presets 3 and 4 Only)
Presets "3" and "4" may be programmed to run for a specified duration after being manually started. This run duration is programmable from 30 minutes to eight (8) hours, in increments of 30 minutes. A setting of 0:00 disables the run duration feature, allowing the preset to run indefinitely.
From the setup menu, select RUN DURATION. Press MENU. Using the arrow keys, select the preset to be programmed. Press MENU. Set the desired run duration for the preset using the arrow keys. Press MENU to accept.
SELECT USER SETUP RUN DURATION
2
ePUMP
MENU
4
3
Page 15
Section 6. Menu Flow Chart
Page 15
USE
USER
SETUP
[OFF]
eSTAR
(Note 1,3)
PRESET 2
(Note 1,3)
PRESET 3 OR 4
(Note 1,4)
PRESET X
(Note 5)
USER SETUP
(Note 6)
SERVICE SETUP
(Note 9)
TIMECLOCK
SET TO [2750]RPM
R: MIN TO MAX
I: 10RPM (Note 2,3)
SET TO [2750] RPM
R: MIN TO MAX
I: 10RPM
(Note 2)
SET TO [5]
R: 5 TO 8
I: 1
SET TIME
SET TO [12:00AM]
R: 12:00AM TO
11:59PM
I: 1 MIN
[DISABLE]
ENABLE
TIMECLOCK
SET TO [2750] RPM
LABEL
PRESET
SELECT
PRESET
SELECT
LABEL TYPE
[DISABLE]
ENABLE
R: MIN TO MAX
I: 10RPM
(Note 2)
GENERAL
CUSTOM
ON TIME
SET TO [10:00AM]
ON TIME
SET TO [10:00AM]
DISPLAY LIGHT
[ 2 MIN TIME OUT ]
OFF TIME
SET TO [4:00PM]
OFF TIME
SET TO [4:00PM]
(Note 8)
LIGHT OFF
LIGHT ON
LABEL LIST
SET TO [“PRESET n”]
R: ALL CHARS
LANGUAGE SELECTION
(Note 7)
[ENGLISH]
SPANISH
FRENCH
SET TO [12:00AM]
R: 12:00AM TO
11:59PM
SET TO [12:00AM]
R: 12:00AM TO
11:59PM
SET TO [12:00AM]
R: 12:00AM TO
11:59PM
SET TO [12:00AM]
R: 12:00AM TO
11:59PM
RUN
DURATION
SELECT
PRESET
SET TO [0:00]
R: 30 MIN TO 8 HRS
I: 30 MIN
SERVICE
SETUP
SET MIN LIMIT
SET TO [600]
R: 600 TO MAX LIM
I: 10
SET MAX LIMIT
SET TO [3450]
R: MIN LIM TO 3450
I: 10
LOAD DEFAULTS
(Note 10)
[NO]
YES
LAST FAULT
[LAST FAULT]
ND
[2
TO LAST]
DURATION
NOTES
Default parameters are shown in [ ]. “R” stands for Range. “I” stands for Increment.
1. Accessed directly by front panel button.
2. Occurs at Run Screen.
3. Timeclock features accessed via MENU button while Preset is running.
4. MENU button has no effect when running.
5. Accessed via MENU button when pump is stopped.
6. Press and hold MENU button for 5 seconds to enter.
7. Is not affected when “LOAD DEFAULTS” is executed.
8. Key
that is pressed to wake up display is also acted upon.
9. Press and hold MENU, eStar, and 4 simultaneously for 5 seconds to enter.
10. Setting not saved in non-volatile memory; reset to “NO” after execution.
PRIMING
[SPEED]
SET TO [2750] R: MIN LIM TO
SET TO [1]
R: 1 TO 5 MIN
SET TO [1750]RPM
SET ESTAR
SPEED
R: MIN TO MAX
I: 10RPM
FREEZE
PROTECT
SET TO [0:30]
R: 0 MIN TO 8 HRS
I: 30 MIN
PUMP
TYPE
[ePUMP]
VSP AC
DISPLAY POWER
USAGE
[NO]
YES
Page 16
LIMITED WARRANTY
®
Thank you for purchasing Jandy free from manufacturing defects in materials and workmanship for a period of one (1) year from the date of retail purchase, with the following exceptions:
• AquaLink
• Never Lube
• AquaPure
®
RS units installed with Jandy® Surge Protection Kits will be covered for two (2) years.
®
valves are warranted for the life of the pool and/or spa on which they were originally installed.
®
Electronic Chlorine Generator Electrolytic Cells carry a five (5) year limited warranty on a prorated basis.
• Heat pumps are covered for two (2) years. There is a lifetime warranty on titanium tubing.
• The heat pump compressor is covered for five (5) years.
This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites. The liability of Zodiac Pool Systems, Inc. shall not exceed the repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective part, transportation to or from the factory, or any other materials required to make the repair. Refrigerant or other expendables are not covered by the warranty. This warranty does not cover failures or malfunctions resulting from the following:
1. Failure to properly install, operate, or maintain the product(s) in accordance with our pubished Installation, Operation and Maintenance Manuals, which are provided with the product(s).
2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH levels between 7.2 and 7.8, with ideal ranges being between 7.4 and 7.6, Total Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000, not including salt ppm].
4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence, or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.
9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-rings, DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.
pool and spa products. Zodiac Pool Systems, Inc. warrants all parts to be
LIMITATION OF LIABILITY:
This is the only warranty given by Zodiac Pool Systems, Inc. No one is authorized to make any other warranties on behalf of Zodiac Pool Systems, Inc. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ZODIAC POOL SYSTEMS, INC. EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT, OR PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY. This warranty
gives you specific legal rights. You may also have other rights that vary by state or province.
WARRANTY CLAIMS:
For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, model number, serial number, and date of installation. The installer will contact the factory to obtain instructions regarding the claim and to determine the location of the nearest designated service center. If the dealer is not available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical support department at 1.800.822.7933. All returned parts must have a Returned Material Authorization number to be evaluated under the terms of this warranty.
Zodiac Pool Systems, Inc.
6000 Condor Drive • Moorpark, CA USA 93021 • 800.822.7933 • Fax 877.327.1403
H0311300A
Litho in U.S.A. © Zodiac Pool Systems, Inc. 0810
Loading...