Jands JLX-LITE-MkII User Manual

Modular Lighting Bar System
JLX-LITE-MkII
USER GUIDE
COMPLIANCE
This product is approved for use in Australia/New Zealand
and conforms to the following standards.
Standards
AS/NZ 3100-2002 - Approval and test specification - General requirements for electrical equipment
Disclaimer
Information contained in this user guide is subject to change without notice and does not represent a commitment on the part of the vendor. JANDS Pty Ltd shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all service and repairs on this product be carried out by JANDS Pty Ltd or its authorised service agents.
JANDS Theatre equipment must only be used for the purpose they were intended by the manufacturer and in conjunction with this user guide.
JANDS Pty Ltd will not accept any liability whatsoever for any loss or damage caused by service, maintenance or repair by unauthorised personnel, or by use other than that intended by the manufacturer.
Manufactured in Australia by
JANDS PTY LTD ABN 45 001 187 837
Head Office: 40 Kent Road, Mascot NSW 2020. Sydney, Australia.
Postal Address: Locked Bag 15, Mascot NSW 1460. Sydney, Australia.
P: (+61) 2 9582 0909 F: (+61) 2 9582 0999
W: www.jands.com.au E: info@jands.com.au
JANDS PTY LTD 2015 All rights reserved.
Revision 1.0
3 March 2015
USG-00000-JLXLITEMKII [1.0]
JLX LITE MKII
1
TABLE OF CONTENTS
1 INTRODUCTION .......................................................................... 2
1.1 Mounting Options ................................................................................. 2
1.2 Layout................................................................................................... 2
2 INSTALLATION............................................................................ 3
2.1 Initial Inspection .................................................................................... 3
2.2 Planning - Mechanical ................................ ................................ .......... 3
2.3 Planning - Electrical .............................................................................. 4
2.4 Installation ............................................................................................ 4
2.5 Perch Bar (Vertical) Installation ............................................................ 6
2.6 Installation Record ................................................................................ 8
3 INSPECTION & MAINTENANCE ................................................. 9
3.1 Annual Equipment Inspection/Maintenance Log ................................ 10
4 TECHNICAL DATA AND SPECIFICATIONS.............................. 11
4.1 Rated Capacity ................................................................................... 12
4.1.1 Definitions of Load .................................................................. 12
4.1.2 Maximum Point Load .............................................................. 12
4.1.3 Maximum Uniformly Distributed Load (UDL) ........................... 12
4.2 Mounting Hole Detail .......................................................................... 13
USG-00000-JLXLITEMKII [1.0]
JLX LITE MKII
2
1 INTRODUCTION
The Jands JLX-LITE-MkII is a universal modular wired bar system intended for fixed installations where a lighting bar with associated fixed wiring is required.
1.1 Mounting Options
The JLX-LITE-MkII includes many mounting holes on its top surface and is intended to be mounted is number of different ways, including:
Surface mounted to ceiling  On a surface mounted frame  Suspended from threaded rods  Vertical mounting as a Perch Bar
The Jands JLX-LITE-MkII is suitable for fixed indoor applications only, and is not protected against the ingress of moisture.
The JLX-LITE-MkII is not rated as a lifting bar under AS4991. The JLX-LITE-MkII is supplied unwired and the wiring should be installed by a licensed electrician.
1.2 Layout
Figure 1 – Component identification
Multiple fixing keyholes
Cable knock-outs in the top and end faces
Removable dress covers
Base
Bar
Bar Hangers
USG-00000-JLXLITEMKII [1.0]
JLX LITE MKII
3
2 INSTALLATION
2.1 Initial Inspection
The Jands JLX-LITE-MkII Lighting bar should be inspected prior to installation. Any dents, cracks or damage that appears to have been suffered in transit should be photographed and the freight company notified before proceeding.
2.2 Planning - Mechanical
The Jands JLX-LITE-MkII should be installed by persons familiar with the installation of load bearing structures.
WARNING
Failure to correctly install the JLX-LITE-MkII may
result in injury or death
The JLX-LITE-MkII has been designed to be mounted in various ways depending on the building struc­ture it is being mounted to. Fixing methods include, but are not limited to:
Direct to a concrete slab using chemical or expanding anchors.  Direct into ceiling joists using timber screws, possibly through an intermediate layer of plaster-
board.
Suspended using droppers.  Into another supporting structure using nuts and bolts. Note mounting to suspended ceiling is
not recommended as these are generally not strong enough to support the required load. If the JLX-LITE-MkII must be mounted against a suspended ceiling it should be mounted to the struc­ture above the ceiling using droppers.
Fixed using standard strut or other additional dedicated structure mounted either along the bar
or preferably perpendicular to the bar. for example surface mounted standard strut.
Do not mount the JLX-LITE-MkII using plasterboard fasteners of any kind - the JLX-LITE-MkII must be fixed to a solid structure.
When locating the fixings, plan the layout so that:
there is at least one substantial fixing for example masonry anchor, per bar support i.e. for a
2.4m JLX-LITE-MkII use at least 4 substantial fixings; for a 1.6 m JLX-LITE-MkII use at least 3 substantial fixings. When using less substantial fixings, for example wood screws, use at least twice the number of fixings and distribute them as evenly across the base as possible.
the fixings are located as close as practical to the bar supports.  if mounting the JLX-LITE-MkII to strut, ensure that the strut is fixed to the structure on either
side of the JLX-LITE-MkII i.e. the strut is not cantilevered.
when installed the mounting face of the duct will be within about 6 degrees of horizontal in both
lengthwise and crosswise directions. If this cannot be achieved in the lengthwise direction, use
Loading...
+ 10 hidden pages