Jamr Technology B66T User Manual

Version Number: 1.0
Fully Automatic Upper Arm
Blood Pressure Monitor
Model Number: B66T
---------------------------------------------------------------------
1
Version Number: 1.0
CONTENTS
1. Introduction and Intended Use..............................................................................................3
2. Important Information on Blood Pressure and its Measurement...........................................5
3. Components of your blood pressure monitor.........................................................................7
4. Using your Monitor for the First Time.....................................................................................8
5. Measurement Procedure.....................................................................................................9
6. Care and Maintenance........................................................................................................16
7. Warranty...............................................................................................................................17
1. Introduction and Intended Use
This manual is for B66T models. It is a fully automatic digital blood pressure
2
Version Number: 1.0
measuring device for use by adults on the upper arm at home or in your doctor’s/nurse’s of fice. It enables very fast and reliable measurement of systolic and diastolic blood pressure as well as pulse through the oscillometric method. This device of fers clinically proven accuracy and has been designed to be user friendly. Before using, please read this instruction manual carefully and then keep it in a safe place. Please contact your doctor for further questions on the subject of blood pressure and its measurement. Warning:Not suitable for neonatal and infants. This device can not be used together with hf surgical equipment.
1.1. Remember…
• Only a health-care professional is qualified to interpret blood pressure measurements.
• This device is NOT intended to replace regular medical checkups.
• It is recommended that your physician review your procedure for using this device.
• Blood pressure readings obtained by this device should be verified before prescribing or making adjustments to any medications used to control hypertensi on. Under no circum st ance s should YOU alter the dosages of any drugs prescribed by your doctor.
• This monitor is intended for use by adults only. Consult with a physician before using this instrument on a child.
•In cases of irregular heartbeat (Arrhythmia), measurements made with this instrument should only be evaluated after consultation with your doctor.
• Familiarize yourself with the section titled "Important Information on Blood Pressure and its Measurement". It contains important information on the dynamics of blood pre ssure readings and will help you to obtain the best results.
NOTE!
• This device contains sensitive electronic components. Avoid strong electrical or electromagnetic fields in the direct vicinity of the device (e.g. mobile telephones, microwave ovens) during use. These can lead to erratic results.
• Do not attempt to service or repair this device yourself. Should a malfunction occur, refer to local distributor or the manufacturer.
Warning
1. Too frequent measurements can cause injury to the PATIENT due to blood flow interference
2. Don’t place the cuff over wound part
3. Pressurization of the CUFF can temporarily cause loss of function of simultaneously used monitoring ME EQUIPMENT on the same limb
Contraindication
Use of this instrument on patients under dialysis therapy or on anticoagulant, antiplatelets, or steroids could cause internal bleeding.
1.2 Warnings and Precautions
3
Version Number: 1.0
Warning: Do not use cuf f s, AC adapters or batteries other than those included with this product or replacement parts supplied by the manufacturer.
Warning: Do not use the batteries and the AC adapter to provide power at the same time. Warning: This system may fail to yield specified measurement accuracy if operated or stored
in temperature or humidity conditions outside the limits stated in the specifications section of this manual. Warning: The separate ac adapter which is intended to connect USB interface of Blood Pressure Monitor has not been evaluated according to IEC 60601-1. The safety of the product shall be reappraised when it power supply by a sepa rate ac adapter.
Warning: Remove the battery if the ME EQUIPMENT is not likely to be used for some time. Warning: The user must check that the equipment functions safely and see that it is in prope r
working condition before being used.
Warning: No modification of this equipment is allowed. Warning: The device is not suitable for use in the presence of flammable anesthetic mixtures
with air or with oxygen or nitrous oxide.
Warning: This equipment shall not be serviced or maintained while in use with the patient Warning: The patient is an intende d operator, the functions of monitoring blood pressure and
pulse rate can be safely used by patient. The routine clean and changing batteries can be performed by the patient. Caution: To avoid any possibility of accidental strangulation, keep this unit away from children and do not drape tubing around your neck.
Caution: To avoid damaging the device, keep this unit away from children a nd pets. Caution: The standard material used for the bladder and tubing is latex-free. Attention: Self-measurement means control, not diagnosis or treatment. Unusual values must
always be discussed with your doctor. Under no circumstances should you alter the dosages of any drugs prescribed by your doctor.
Attention: The pulse display is not suitable for checking the frequency of heart pacemakers! Attention: In cases of irregular heartbeat, measurements made with this instrument should
only be evaluated after consultation with your doctor. Note: To obtain the greate st accuracy from your blo od pressure inst rument, it is recommended that the instrument be used within the specified temperature and the relative humidity, please see the Technical Specifications Note: The cuff is treated as the applied part.The user should contact the manufacturer for assistance, if needed, in setting up, using or maintaini ng the device.
2. Important Information on Blood Pressure and its Measurement
2.1. How does high or low blood pressure arise?
Your level of blood pressure is determined in the circulatory center of the brain and adjusts to a
4
Version Number: 1.0
variety of situations through feedback from the nervous system. To adjust blood pressure, the strength and speed of the heart (Pulse), as well as the width of circulatory blood vessels is altered.Blood vessel width is controlled by fine muscles in the blood vessel walls. Your level of arterial blood pressure changes periodically during heart activity: During the “blood ejection” (Systole) the value is highest (systolic blood pressure value). At the end of the heart’s “rest period” (Diastole) pressure is lowest (diastolic blood pressure value). Blood pressure values must lie within certain normal ranges in order to prevent particular diseases.
2.2. Which values are normal?
Please refer to the diagram below(Picture-01)
Picture-01
There are six grids in the display of device. Please refer to the picture-02. Different grids represent different interval scales of WHO.
Picture-02
Blood pressure is very high if your diastolic pressure is above 90 mmHg and/or your systolic blood pressure is over 160 mmHg, while at rest. In this case, please consult your physician immediately. Long-term values at this level endanger your health due to continual damage to the blood vessels in your body. If your systolic blood pressure values are between 140 mmHg
5
Version Number: 1.0
and 159mmHg and/or the diastolic blood pressure values between 90 mmHg and 99mmHg, consult your physician. Regular self-checks are necessary. If you have blood pressure values that are too low, (i.e., systolic values und er 105mmHg and/or di astolic values u nder 60 mmHg), consult your physician. Even with normal blood pressure values, a regular self-check with your blood pressure monitor is recommended. You can detect possible changes in yo ur values early and react appropriately. If you are undergoing medical treatment to control your blood pressure, keep a record of values along with time of day and date. Show these values to your physician. Never use the results of your measurements to independently alter the drug doses prescribed by your physician.
Further information
• If your values are mostly normal under resting conditions but exceptionally high under conditions of physical or psychological stress, it is possible that you are suf f ering from so-called “labile hypertension.” Consult your doctor.
• Correctly measured diastolic blood pressure values above 120mmHg require immediate medical treatment.
2.3. What can be done if regular high or low values are obtained?
1) Consult your doctor.
2) Increased blood pressure values (various forms of hypertension) are associated with considerable health risks over time. Arterial blood vessels in your body are endangered due to constriction caused by deposits in the vessel walls (Arteriosclerosis). A deficient supply of blood to important organs (heart, brain, muscles) can result from arteriosclerosi s. Furthermore, the heart will become structurally damaged with increased blood pressure values.
3) There are many different causes of high blood pressure. We differentiate between the common primary (essential) hypertension, and secondary hyperten sion. The latter group can be ascribed to specific organ malfunctions. Please consult your doctor for information about the possible origins of your own increased blood pressure values.
4) There are measures which you can take to reduce and even prevent high blood pressure.
3. Components of your blood pressure monitor
3.1. Measuring unit
6
Loading...
+ 12 hidden pages