COMPLIES WITH THE FOLLO WING PROVISIONS APPLYING T O IT .
EN-50081-1
EN-50082-1
CV-M530/531
Table of Contents
Table of Contents ....................................................................................................................................... 2
3.Main Features ..................................................................................................................................... 4
4.Locations and Functions ..................................................................................................................... 5
12. User’s Record .................................................................................................................................... 23
- 2 -
CV-M530/531
1. General
The model CV-M530/531 are new remote head (ø28mm) camera systems, designed to accept standard
C-mount lens, and have virtually identical features of popular CV-M50 (1/2") machine vision camera.
The new 1/2" Hyper HAD imager employed in the CV-M530/531 camera head provides superior
sensitivity and higher dynamic range with improved smear level.
High speed shutter and asynchronous random trigger functions allow a superb image quality in
machine vision and image processing applications such as dynamic motion image capturing, on-line
inspection, gauging, printing and graphics.
CV-M530/531 are two models with different cable length, as described in the following list.
ModelCable length
CV-M5300.5m ( 1.64 feet)(Cable is directly mounted on camera head)
CV-M5312.0m ( 6.56 feet ) (Cable is directly mounted on camera head)
Important Notice!
CV-M530/531 have inter-changeability between camera head and CCU’s within the same model.
(e.g. CV-M530 camera head
However, CV-M530 camera head
can be usedcan be used
can be used
can be usedcan be used
cannot be usedcannot be used
cannot be used
cannot be usedcannot be used
with CCU’s from other set of CV-M530’s.
with CCU’s from CV-M531.)
2. Standard Composition
1) Camera headx1 (incl. camera cable)
2) Camera control unitx1
3) Operation manualx1
Options (Following optional accessories are available upon request.)
1) 12pin Multi Connector (HR10A-10P-12S)
2) 6pin Multi Connector (HR10A-7P-6S)
3) MP-40 Tripod mount adaptor
4) MP-15 Tripod mount
- 3 -
CV-M530/531
3. Main Features
•Remote head - ø28mm (1.10 inches) separated from camera control unit via a 0.5m or 2.0m cable.
•1/2" Hyper HAD interline transfer CCD imager, 768(H) x 494(V) for EIA and 752(H) x 582(V) for CCIR
•High resolution - horizontal 570 TV lines for EIA, 560 TV lines for CCIR
•Excellent S/N - better than 56dB
•High sensitivity - 0.05 lx minimum illumination on CCD imager
•Improved low smear and higher dynamic range
•Edge pre-select and pulse width external trigger modes
•High speed and random trigger shutter up to 1/10,000 sec.
•Long-time exposure mode- 1/30 sec. ~∞ (EIA)
- 1/25 sec. ~∞ (CCIR)
•WEN and EEN output (pixel clock output : user option) - to support further advanced image capturing
•Internal, external HD/VD synchronization
•Easy access for mode-setting of shutter and other function from rear panel
•Lens mount - C mount type
•Durable camera cable for industrial environment - 0.5m (1.64 feet) and 2m (6.56 feet)
- 4 -
4. Locations and Functions
4-1. CCU
7
CV-M530/531
4-2. HEAD
1
234
56
7
9
108
112P connector: To connect camera head with camera control unit
(For Camera Head)
2Video output connector: To output video VS1.0Vp-p
(BNC connector)
3SW1 switch: To set shutter speed and function modes
46-pin Multi connector: Output WEN/EEN signal and input external trigger pulse, etc.
5GAIN: To adjust gain level
612P Multi connector: Input DC+12V power and input/output of HD/VD signal, etc.
7Screw holes for Tripod mount plate : To fix tripod mount plate (optional) on camera
8CCD sensor: 1/2" Hyper HAD Interline transfer CCD sensor
9Camera head mount: To mount camera head
10 Camera head connector: To connect camera head with cable
- 5 -
CV-M530/531
5. Pin Assignment
5.1. 12-pin Multi-connector (DC-IN/SYNC.)
Type: HR10A-10R-12PB (Hirose) male
Seen from rear.
Notes:
*1) Signals on pin no. 6, 7 and 9 can be changed by jumper setting.
See “7.3. Jumper Settings” for more information.
*2) In Edge Pre-select and Pulse Width Control mode do not input ext. VD signal.
5.2. 6-pin Multi-connector (TRIGGER)
Type: HR10A-7R-6PB (Hirose) male
Seen from rear.
Pinno.SignalRemarks
12
3456
* Notes:
The functions available on the 6-pin multi-connector are not effective in
long time exposure mode.
NC
EENoutput*Note
GND
NC
Ext.Triginput*Note
WENoutput*Note
- 6 -
CV-M530/531
6. Functions and Operations
6.1. Input/Output of HD/VD Signal
6.1.1. Input of External HD/VD Signal
As factory setting the camera can be synchronized by external HD/VD signals. The signal level must be
4.0V p-p +/- 2.0V at the input with the 75 Ohm termination ON. To change to non-terminated input, see
instructions in “7. Mode Setting”.
If no ext. HD is connected, the camera will switch to the internal X-tal controlled HD.
If no ext. VD is connected, the camera will continue with its internal VD.
6.1.2. Output of Internal HD/VD Signal
The internal HD/VD output is 4.0V p-p from a 75 Ohm source.
To select this mode, see instructions in “7. Mode Setting”.
6.2. Normal Shutter Mode
When trigger select SW1-4 is OFF, the camera is in normal mode. The SW1-1, SW1-2 and SW1-3 are for
selecting the shutter speed. The range is from OFF to 1/10,000 second in 8 steps. The camera is running
continuously with an exposure as the selected shutter time.
The shutter time setting is shown in “7.1.3. Table for Shutter Time”.
6.3. External Trigger Mode
External trigger mode of CV-M530/531 allows 4 different driving modes, as follow.
1Edge pre-select mode. (Asynchronous reset and exposure start by an ext. trigger)
2Pulse width control mode. (Exposure control by the low period of the ext. trigger)
3Start/Stop trigger mode. (Exposure start by the ext. trigger and end by the ext. VD signal)
4Long time exposure mode. (Exposure control by the interval of the ext. VD signal)
The trigger input is AC coupled, so there is a maximum pulse width for the trigger pulse about 60 msec.
The signal level must be 4.0V p-p +/- 2.0V on the input with the 75 Ohm termination ON. To change to
non-terminated input, see instructions in “7. Mode Setting”.
The following describes the details of each trigger mode.
6.3.1. Edge Pre-select Mode
The edge pre-select mode operation will only work in non-interlaced and field accumulation mode. The
CV-M50 starts the exposure (= accumulation of photoelectric charge) at the first HD pulse after the
falling edge of the ext. trigger pulse. The exposure ends after the time set by the 3 shutter switches
SW1-1 to SW1-3. The range is 8 steps from OFF (1/60 or 1/50) to 1/10,000 second.
In this mode, the EEN (Exposure ENable) pulse and WEN (Write ENable) pulses are generated and
output from the camera. The EEN pulse indicates the exposure time and can be used to control the
illumination such as strobe light. The EEN pulse is output from pin 2 of the 6-pin multi connector. The
signal level is 4.0 Vp-p from a 75 Ohm source.
The WEN pulse indicates the time period of the effective video signal output, and is useful for the timing
and interfacing of external devices such as frame grabbers. The WEN pulse is output from pin 6 of the 6pin multi connector. The signal level is 4.0 Vp-p from a 75 Ohm source.
The video must be read out before a new trigger can be applied. The interval between trigger pulses
must be longer than the time for 1 field + the shutter time. It is the limit for the field rate.
- 7 -