8751.050014
ATTENTION !!
1.5 m
The room thermostat must be installed at approx.
1.5 m above floor and out of reach of external influ­ences such as direct sunlight, draught or other heat sources as they may impede the correct functioning of the thermostat. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.
UPUP
6
2.7
Mount the JRT-300 Room thermostat on a wall re­cessed box (60.3 mm fixing centers) or direct onto a flat
wall using wall plugs.
Features
• for heating systems
• display with back-light
• programmable Monday to Friday, Saturday, Sunday (5+1+1), 2 programmable time zones per day
• displays the measured temperature and time
• temperature in °Celsius
• surface-mounting
• with a wall-fixing frame
Technical Data
Operating voltage: 2 x AA A1.5 V, alkaline batteries.
Backup storage: EEPROM
Max. voltage / (ohm) load: 8 A.
Channel selection: By programming the thermostat and the receiver.
Switching options: 5+1+1 day, 2 periods each day.
Temperature settings: 5°C ~ 30°C, 0.5°C increments.
Accuracy: +/- 0.5°C.
Thermostat dimensions: Surface mounted, 135mm x 87.5 mm x 23.2mm.
Housing: ABS to UL94-5 fire retardant plastic, white
IP protection rating: 20
Certification: CE
Product-documentation:
• this manual is an integral part of the unit and must be handed over to the user after the installation of the device is completed in order to comply with applicable legal requirements.
• please read the manual carefully so that you understand the information in order to ensure safety during installation, use and maintenance.
• no liability is accepted for damage resulting from non-compliance with the guidelines in this installation manual.
Dimensions
SET
PRG
13.5
8.758
2.711.8
6.2
9.9
2.3
CE-mark
The CE-mark symbolizes the compliance of the device with the following guide­lines:
• EN 61000-6-3:2007+A1:2011
• EN 61000-3-2:2006+A1:2009+A2:2009
• EN 61000-3-3:2008
• EN 61000-6-1:2007
IMPORTANT: This manual will guide you through the installation, setup and use of the Jaga Room Thermostat JRT-300. Keep this manual in a safe place for future reference.
E - 28 januari 2019, 12:41 - Jaga N.V.
Jaga Room Thermostat JRT-300
manual:
installation
Installation
WIRING:
Warning: The installation of the thermostat should be performed by qualified personnel and must comply with the applicable local and national electrical codes and utility requirements. All wire connections must be tightened and properly arranged to prevent a shortcircuit.
UPUP
6
- Carefully remove the front panel - When not using a recessed con­duit box:
• mark out and drill the holes
• screw the back plate to the
wall. The type of wall, solid or cavity, determines the type of screw or plug that is used.
Mount the JRT-300 Room ther­mostat on a wall recessed box (60.3 mm fixing centers) or direct onto a flat wall using wall plugs.
NONCCOM
JRT 300 Wiring diagram
1 2 3
L
N
N
L
max. 8A
24 - 230V
˜
NO
NC
COM
Insert the wire through the hole of the back plate
Follow this wiring diagram Re-assemble the front panel: be careful with the connection pins !
Replacing batteries
Carefully remove the front panel
2 x AA A1.5 V, Alkaline batteries. Carefully remove the battery
cover
NOTE: POS + and NEG - are marked on the battery cover !!
Gently close the cover.
E - 28 januari 2019, 12:41 - Jaga N.V.
Jaga Room Thermostat JRT-300
manual: setup & user
Control panel
SET
PRG
°C
PRG
PRG MAN
ROOM SET
User:
• 7-day programming: 5+1+1 (Monday to Friday / Saturday / Sunday)
• 4 setting (2 on/off) periods per day
Attention: after 15” of inactivity, the thermostat will return to the start-up screen, and the adjustments will be automatically confirmed.
Turn on the thermostat: short press the “ON / OFF” button
Clock adjustment:
Set the current time: press the “SET” button and hold it down for 3 seconds.
• Press “+“ or “-“ to adjust the minutes (88:88) (each press is 1 minute)
• Press “SET” to confirm. Press “+” or “-“ to adjust the hour ((88:88)) (each press is 1 hour), press “SET” to confirm
• Press “+“ or “-“ to set the current day
, press “SET” to confirm
Temperature pre-set:
Press the “PRG” button and hold it down for 3 seconds.
Monday to friday
:
Set the first time zone:
• Scroll with “+“ or “-“ (per 15”) to set the PRG1 time, press “PRG” to confirm. Set temperature (per 0.5°), press “PRG” to confirm.
• Scroll with “+“ or “-“ (per 15”) to set the PRG 2 time, press “PRG” to confirm. Set temperature (per 0.5°), press “PRG” to confirm.
Set the second time zone:
• Scroll with “+“ or “-“ (per 15”) to set the PRG 3 time, press “PRG” to confirm. Set temperature (per 0.5°), press “PRG” to confirm.
• Scroll with “+“ or “-“ (per 15”) to set the PRG 4 time, press “PRG” to confirm. Set temperature (per 0.5°), press “PRG” to confirm.
Repeat this for the periods
and
.
Short press the ON / OFF button to return to the startup screen.
Programming & week / day
Clock
Room temperature
Set temperature
 Heating
ON / OFF” button
Program
Temperature Calibration
For experts only !! Turn off the thermostat: short press the “ON / OFF” button
Range -8°C tot +8°C. After turning off the thermostat, press the “SET“ button and hold it down for 3 seconds. Use “+“ or “-“ to calibrate the thermostat.
Temperature pre-set EXAMPLE:
Setting: 1st time zone 2nd time zone
Program: PRG 1 PRG 2 PRG 3 PRG 4
1 2 3 4 5 Monday~Friday
6:30 8:00 18:30 22:30
21°C 18°C 21°C 16°C
6 Saterday
6:30 8:00 18:30 22:30
21°C 18°C 21°C 16°C
7 Sunday
6:30 8:00 18:30 22:30
21°C 18°C 21°C 16°C
E - 28 januari 2019, 12:41 - Jaga N.V.
Jaga Room Thermostaat JRT-300 manual
Please follow and keep these instructions!
User: temperature pre-set
Setting: 1st time zone 2nd time zone
Program:
PRG 1 PRG 2 PRG 3 PRG 4
1 2 3 4 5
Monday~Friday
uur
Temp °C
6
Saterday
uur
Temp °C
7
Sunday
uur
Temp °C