Jade Range LLC, A Middleby Company
2650 Orbiter Ave.
Brea, CA 92821
Telephone (714) 961-2400
FAX (714) 961-2550
JADE TACO RANGES
MODEL: JTR and JTRB Series
JADE STOCK POT RANGES
MODEL: JSP Series
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
NOTE: Instructions must be posted in a prominent location, which will instruct the user in the
event that he/she detects the odor of gas. This information shall be obtained from your local
gas company.
FOR YOUR SAFETY
Do not store or use gasoline or
other flammable vapors or
liquids in the vicinity of this or
any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Open Windows
• Do not touch electric switches
•
Extinguish any open flame
•
Immediately call your gas company
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause damage, injury or death.
Read the installation, operating and maintenance
instructions thoroughly before installing or servicing
this equipment.
Adequate clearances must be provided in front, rear and at sides of appliance for servicing.
The appliance area must be kept free and clear from combustibles. There must be no material
or obstacles obstructing the flow of combustion and ventilation air.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 24-133 REV C 01/2007 Page 1
INSTALLATION INSTRUCTIONS
IMPORTANT
Read these instructions carefully before starting the installation. Upon receipt of your
equipment, thoroughly inspect it for any damage. If any damage is noted, immediately file a
claim with the trucking company. Failure to contact the trucking company immediately may
result in their refusal of your claim. After checking for damage, examine the markings on the
equipment to ensure that type of gas is correct.
INSTALLATION
A qualified installer, service agency, or gas supplier must perform installation and service.
Provisions shall be incorporated in the design of the kitchen to ensure an adequate supply
of fresh air for proper combustion.
It is suggested that for servicing and proper operation, at least 36 inches of free area be
provided to the front of the appliance.
The installation must conform with local codes, or in the absence of local codes, to the
National Fuel Gas Code, ANSI Z223.1-2007or latest edition.
Level appliance. Adjustable legs are provided. If the appliance is equipped with casters, the
installation shall be made with a connector that complies with the Standard for Connectors
for Movable Gas Appliances, ANSI Z21.69B-2006 CSA 6.61B 2006 or latest edition, and a
quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for
Use With Gas Fuel, ANSI Z21.41a-2005 CSA 6.9-2005 or latest edition.
Adequate means must be provided to limit the movement of the appliance without
depending on the connector and the quick-disconnect device or its associated piping to limit
the appliance movement. The restraining means may be attached to the rear of appliance
by cable. Refer to the illustration provided on the last page.
The input rating of your equipment is for elevations up to 2,000 feet. For elevations above
2,000 feet, the rating must be reduced 4% for every 1,000 feet above sea level.
This appliance is design certified for installation in noncombustible locations only. Minimum
clearances from noncombustible construction are zero (0) inches.
Means must be provided for adequate air supply and adequate clearance for air openings
into the combustion chamber.
GAS PIPING
This appliance is provided with a regulator, set a 5” W.C. for natural gas or 10” W.C. for
propane gas.
P/N 24-133 REV C 01/2007 Page 2