Jade JMSS Installation Manual

Jade Range LLC, A Middleby Company
2650 Orbiter Ave. Brea, CA 92821 Telephone (714) 961-2400 FAX (714) 961-2550
SAUTE′′′ STATIONS
MAINTENANCE INSTRUCTIONS
To make doubly certain that you are satisfied with your new equipment, please spend a few minutes to read these important instructions.
For future reference, record the following information and refer to it when contacting the factory or an authorized service agent.
Model Number:
Date Purchased:
Installation Date:
Adequate clearances must be provided in front, rear and at sides of appliance for servicing. The appliance area must be kept free and clear from combustibles. There must be no material or obstacles obstructing the flow of combustion and ventilation air.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
Thank you for ordering one of the most unique products to be introduced in the food service market. The Saute Station has a very distinct operation and use. Kindly read the following to ensure proper operation of your new Saute Station.
Serial Number:
Purchased From:
Installed by:
Telephone Number:
P/N 24-146 REV A 7/00 Page 1
INSTALLATION
IT IS STRONGLY RECOMMENDED THAT THE EQUIPMENT BE INSTALLED AND PUT INTO OPERATION BY A QUALIFIED COMMECIAL REFRIGERATION MECHANIC. Claims under the Extended Protection Plan (if purchased) must be accompanied by proof that this was done.
Units are designed to have either one or all of the following:
Electrical connections Refrigeration connections Drain line connection.
Units are designed to be a water bath-cooling unit. Saute bins are cold wall (coil wrapped) using water as a conducting agent. Each unit is equipped with a ½” i.p.s. brass drain for water bath cleaning. On self-contained units, the cabinets are supplied with a cord and plug. On remote units, the cabinets are supplied with ¼” and 3/8” refrigeration lines for refrigeration hook­up and a 4” x 4” junction box for electrical hook-up.
CALIBRATION AND SET-UP
All units are pre-set at a factory prior to shipment. This does not ensure proper operation. All units MUST be calibrated to proper operating temperatures prior to use. Water bath temperature must be at 33-35°F after unit has been allowed to cool down.
ADJUSTING TEMPERATURE CONTROL
Temperature control knob is located on either the stub-back or back riser panel of unit. With a flat head screwdriver or similar item, pry open circular cap from control panel. Temperature control know should be visible. The knob should indicate the numbers 1 through 9, position 9 being the coldest setting. The unit is set a position 2 at the factory. NEVER turn the control knob more than one position at a time! Always allow enough time for unit to stabilize after each adjustment.
ELECTRICAL REQUIREMENTS (if cabinets are self-contained)
To prevent the possibility of the circuit being overloaded, we recommend that a separate circuit be provided for each cabinet. All cabinets must be grounded and must be operated only on the electrical supply indicated by the rating plate on the right interior wall. Electrical supply cords are furnished where the ampere load permits; two types of male plugs are supplied – one with parallel blades for 15-ampere circuits, one with perpendicular blades for 20-ampere circuits. When a supply cord cannot be furnished, 6-inch leads for connection to permanent wiring are provided in the junction box labeled “power supply.”
LOADING THE CABINET
Products should not be put into the cabinet until the temperature has dropped to the normal range specified previously. The way in which the cabinet is loaded will affect its efficiency, so allow sufficient time for the water to cool down and ensure that there is a minimum of ¼” to ½”
P/N 24-146 REV A 7/00 Page 2