Jade JMRHE Installation Manual

Jade Range LLC, A Middleby Company
2650 Orbiter Ave. Brea, CA 92821 Telephone (714) 961-2400 FAX (714) 961-2550
JADE TITAN MODULAR RANGES
MODELS: JMRH and JMRHE
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
- Open Windows
- Do not touch electric switches
- Extinguish any open flame
- Immediately call your gas company
WARNING Improper installation, adjustment, alteration, service or maintenance can cause damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
Adequate clearances must be provided in front, rear and at sides of appliance for servicing. The appliance area must be kept free and clear from combustibles. There must be no material or obstacles obstructing the flow of combustion and ventilation air.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 24-200 REV A 7/00 Page 1
INSTALLATION INSTRUCTIONS
IMPORTANT
Read these instructions carefully before starting the installation. Upon receipt of your equipment, thoroughly inspect it for any damage. If any damage is noted, immediately file a claim with the trucking company. Failure to contact the trucking company immediately may result in their refusal of your claim. After checking for damage, examine the markings on the equipment to ensure that type of gas is correct.
INSTALLATION
A qualified installer, service agency or gas supplier must perform installation and service.
Provisions shall be incorporated in the design of the kitchen to ensure an adequate supply
of fresh air for proper combustion.
It is suggested that for servicing and proper operation, at least 36 inches of free area be
provided to the front of the appliance.
The installation must conform with local codes, or in the absence of local codes, in the USA,
to the National Fuel Gas Code, ANSI Z223.1-1988 or latest edition, and in Canada, CAN/CGA-B149.1 and CAN/CGA-B149.2, Installation Code for Gas Burning Appliances and Equipment.
Level appliance. Adjustable legs are provided. If the appliance is equipped with casters,
the installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69-1987 or latest edition and a quick­disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41-1989 or latest edition. In Canada, the flexible connector must be CGA approved and comply with the CAN 1.6.10-88. Quick disconnect must comply with CAN 1.6.9.M79.
Adequate means must be provided to limit the movement of the appliance without
depending on the connector and the quick-disconnect device or its associated piping to limit the appliance movement. The restraining means may be attached to the rear of appliance by cable and hook.
The input rating of your equipment is for elevations up to 2,000 feet. For elevations above
2,000 feet, the rating must be reduced 4% for every 1,000 feet above sea level.
The appliance shall be installed with the following minimum clearances to adjacent
constructions:
COMBUSTIBLE NONCOMBUSTIBLE
Sides 4 inches 0 inches Rear 2 inches 0 inches
The appliance shall be installed on noncombustible counters. When equipped with high
legs, with or without casters, the appliance may be installed on combustible floors.
P/N 24-200 REV A 7/00 Page 2
Loading...
+ 2 hidden pages