INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS
WARNING — WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD AL WAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
DANGER: — TO REDUCE THE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE THIS UNIT
UNLESS THEY ARE CLOSEL Y SUPERVISED A T ALL TIMES.
WARNING — USE THIS UNIT ONL Y FOR ITS INTENDED USE AS DESCRIBED IN THIS MANUAL. DO
NOT USE ATTACHMENTS NOT RECOMMENDED BY THE MANUFACTURER.
WARNING — NEVER DROP OR INSERT ANY OBJECT INTO ANY OPENING .
WARNING — DO NOT OPERATE THIS UNIT WITHOUT THE GUARD OVER THE SUCTION FITTING.
WARNING — THIS UNIT MUST BE CONNECTED ONLY TO A SUPPLY CIRCUIT THAT IS PROTECTED
BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI). SUCH A GFCI SHOULD BE PROVIDED BY
THE INSTALLER AND SHOULD BE TESTED ON A ROUTINE BASIS. TO TEST THE GFCI, PUSH THE
TEST BUTTON. THE GFCI SHOULD INTERRUPT POWER. PUSH THE RESET BUTTON. POWER
SHOULD BE RESTORED. IF THE GFCI FAILS TO OPERATE IN THIS MANNER, THE GFCI IS
DEFECTIVE. IF THE GFCI INTERRUPTS POWER TO THE BATHTUB WITHOUT THE TEST BUTTON
BEING PUSHED, A GROUND CURRENT FLOWING, INDICATING A POSSIBILITY OF AN ELECTRIC
SHOCK. DO NOT USE THIS HYDROMASSAGE BATHTUB. DISCONNECT THE HYDROMASSAGE
BATHTUB AND HAVE THE PROBLEM CORRECTED BY A QUALIFIED SERVICE REPRESENTATIVE
BEFORE USING.
WARNING — (FOR PERMANENTLY CONNECTED UNITS) A GREEN COLORED TERMINAL (OR A WIRE
CONNECTOR MARKED “G”, “GR”, “GROUND”, OR “GROUNDING”) IS PROVIDED WITHIN THE TERMINAL
COMPARTMENT. TO REDUCE THE RISK OF ELECTRIC SHOCK, CONNECT THE TERMINAL OR
CONNECTOR TO THE GROUNDING TERMINAL OF YOUR ELECTRIC SERVICE OR SUPPLY PANEL WITH
A CONDUCTOR EQUIVALENT IN SIZE TO THE CIRCUIT CONDUCTORS SUPPLYING THIS EQUIPMENT.
OPERATING
WARNING — PROLONGED IMMERSION IN HOT WATER MAY INDUCE HYPERTHERMIA. HYPER-
THERMIA OCCURS WHEN THE INTERNAL TEMPERA TURE OF THE BODY REACHES A LEVEL SEV ERAL DEGREES ABOVE THE NORMAL BODY TEMPERATURE OF 98.6°F. THE SYMPTOMS OF
HYPERTHERMIA INCLUDE AN INCREASE IN THE INTERNAL TEMPERATURE OF THE BODY, DIZZINESS, LETHARGY, DROWSINESS AND FAINTING. THE EFFECTS OF HYPERTHERMIA INCLUDE:
A) FAILURE TO PERCEIVE HEAT
B) FAILURE TO RECOGNIZE THE NEED TO EXIT THE SPA OR HOT TUB,
C) UNAWARENESS OF IMPENDING HAZARD,
D) FETAL DAMAGE IN PREGNANT WOMEN,
E) PHYSICAL INABILITY TO EXIT THE SPA OR HOT TUB, AND
F) UNCONSCIOUSNESS RESULTING IN DANGER OF DROWNING.
WARNING — THE USE OF ALCOHOL, DRUGS OR MEDICATION CAN GREATLY INCREASE THE
RISK OF FATAL HYPERTHERMIA.
WARNING — DO NOT TAMPER WITH USER-OPERATED CONTROLS OR SUCH DEVICES.
2
Jacuzzi Whirlpool Bath K339000X 3/06
INST ALLATION INSTRUCTIONS
WARNING — WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
DANGER — RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND
FAULT CIRCUIT INTERRUPTER (GFCI).
CAUTION — TEST THE GROUND FAULT CIRCUIT INTERRUPTER PROTECTING THIS APPLIANCE
PERIODICALLY IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS.
WARNING — USE THIS UNIT ONLY FOR ITS INTENDED USE AS DESCRIBED IN THIS MANUAL. DO NOT
USE ATTACHMENTS NOT RECOMMENDED BY THE MANUFACTURERS.
WARNING — TO AVOID INJURY, EXERCISE CAUTION WHEN ENTERING OR EXITING THE HYDROMASSAGE BATHTUB.
WARNING — KEEP BODY AND HAIR A MINIMUM OF 6" (15,2 cm) AWAY FROM SUCTION FITTING AT ALL
TIMES WHEN THE HYDROMASSAGE SYSTEM IS OPERATING. HAIR LONGER THAN SHOULDER
LENGTH SHOULD BE SECURED CLOSE TO THE HEAD.
WARNING — RISK OF ELECTRICAL SHOCK; DO NOT PERMIT ELECTRICAL APPLIANCES (SUCH AS HAIR
DRYER, LAMP, TELEPHONE, RADIO OR TELEVISION) WITHIN 60" (1,5 M) OF THIS HYDROMASSAGE BATHTUB.
WARNING — RISK OF ACCIDENTAL INJURY OR DROWNING; DO NOT USE DRUGS OR ALCOHOL
BEFORE OR DURING THE USE OF HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER TO AVOID
UNCONSCIOUSNESS AND POSSIBLE DROWNING.
WARNING — RISK OF FETAL INJURY; PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD
CONSULT A PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER.
WARNING — RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; DO NOT USE A HYDROMASSAGE
BATHTUB EQUIPPED WITH A HEATER IMMEDIATELY FOLLOWING STRENUOUS EXERCISE.
WARNING — RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; WATER TEMPERATURE IN
EXCESS OF 104°F (40°C) MAY BE INJURIOUS TO YOUR HEALTH. CHECK AND ADJUST WATER
TEMPERATURE BEFORE USE.
WARNING — RISK OF HYPERTHERMIA; PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE
MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB
EQUIPPED WITH A HEATER.
ENGLISH
FOR BUILT-IN AND DROP-IN UNITS, INSTALL TO PERMIT ACCESS FOR SERVICING.
THIS UNIT SHOULD BE ELECTRICALLY GROUNDED AND INSTALLED BY A LICENSED CONTRACTOR, ELECTRICIAN, AND PLUMBER.
BUILDING MATERIALS AND WIRING SHOULD BE ROUTED AWAY FROM THE MOTOR/PUMP OR
BLOWER OR OTHER HEAT PRODUCING COMPONENTS OF THIS UNIT.
A PRESSURE WIRE CONNECTOR IS PROVIDED ON THE EXTERIOR OF THE MOTOR/PUMP AND
HEATER TO PERMIT CONNECTION OF AN NO. 8 AWG (8.4 MM) SOLID COPPER BONDING CONDUCTOR
BETWEEN THIS UNIT AND ALL OTHER ELECTRIC EQUIPMENT AND EXPOSED METAL IN THE VICINITY,
AS NEEDED TO COMPLY WITH LOCAL REQUIREMENTS.
PRECAUTIONS
••
•Do not operate the hydromassage system unless the bath is filled with water to at least 1" to 2" (2,5 - 5,08 cm) above the
••
highest jet.
••
•Do not immerse the control panel by overfilling the bath.
••
••
•Do not use oil-based bath additives in your hydromassage bath.
••
••
•When cleaning your bath, do not use abrasive substances which will damage the bath's surface.
••
••
•To prevent discoloration of the acrylic finish, do not fill the bath with water in excess of 140°F (60°C).
••
NOTE: This is a professional grade product. A knowledge of construction techniques, plumbing and electrical installation according to codes are required for proper installation and user satisfaction. W e recommend
that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath products. Our warranty does
not cover improper installation related problems.
PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT.
The Company has obtained applicable code (standards) listings generally available on a national basis for products of this type.
It is the responsibility of the installer/owner to determine specific local code compliance prior to installation of the product. The
Company makes no representation or warranty regarding, and will not be responsible for any code compliance.
Framing and Support _________________________________________________________________ 14
Service Access ______________________________________________________________________ 15
ALLUSION Installation ________________________________________________________________ 16-17
Electrical Connections _________________________________________________________________ 18
Plumbing and Water Supply ____________________________________________________________ 19
Clean Up Af ter Installation _______________________________________________________________ 19
Operating Instructions __________________________________________________________________ 20-22
Maintenance Instructions ________________________________________________________________ 23-24
General Troubleshooting Guide ___________________________________________________________ 25
Authorized Service _____________________________________________________________________ 26
Warranty _____________________________________________________________________________ 27-28
NOTE: If you need a referral for a service company near you, or need assistance with operation or maintenance
related questions, please call our Service Support Department at 1-800-288-4002. Visit our web site at http://www.jacuzzi.com/ for products and services.
To find service agent listings for:
Electrical or Mechanical Repairs visit http://jacuzzi.com/pdf/ASA.PDF
Finish, Surface, or Shell-Related Repairs visit http://jacuzzi.com/pdf/AFC.PDF
Repair Parts or Accessories visit http://jacuzzi.com/pdf/MPD.PDF
Jacuzzi Whirlpool Bath K339000X 3/06
4
SPECIFICATIONS
)
Important: Read complete instructions before beginning installation.
Each whirlpool bath arrives ready for installation, completely equipped with motor/pump assembly , heater , plumbing, and fittings necessary for whirlpool operation. An optional drain/overflow kit is available for installation on the
bath.
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been
made. Do not lift the bath by the plumbing at any time; handle by the shell only.
Immediately upon receipt, inspect the shell before installing. Should inspection reveal any damage or defect in the
finish, do not install the bath. Damage or defect to the finish claimed after the bath is installed is excluded from the
warranty . Jacuzzi Whirlpool Bath's responsibility for shipping damage ceases upon delivery of the products in good
order to the carrier. Refer any claims for damage to the carrier . For definitions of warranty coverage and limit ations,
refer to the published warranty information packed with the product.
All bath units are factory tested for proper operation and watertight connections prior to shipping. NOTE: Prior to
installation, the bath must be filled with water and operated to check for leaks that may have resulted from
shipping damage or mishandling. Jacuzzi Whirlpool Bath is not responsible for any defect that could have been
discovered, repaired, or avoided by following this inspection and testing procedure.
4"
(102 mm)
L
(Heater)
2"
(51 mm)
SIDE VIEW
MAX 1"
W
H
(Motor)
END VIEW
A
B
DRAIN/OVERFLOW
ALLUSION
ENGLISH
2"
(51 mm)
H
L
SIDE VIEW
L
(Heater)
SIDE VIEW
L
(Heater)
SIDE VIEW
(Heater)
(Motor)
ELARA
MAX. 1/2"
MAX. 1/2"
(Motor)
BELLAVISTA
MAX. 1/2"
H
END VIEW
(51 mm)2"
(Motor)
SABELLA
H
W
W
END VIEW
W
END VIEW
1/2"
(13 mm
1"
(25 mm)
2"
(51 mm)
H1
L
(Heater)
(Motor)
MAX. 1/2"
H
END VIEW SIDE VIEW
CIPREA™, Right Hand
L
(Heater)
(Motor)
SIDE VIEW
MAX. 1/2"
H
W
END VIEW
REÁL™, Right Hand
L
(Heater)
2"
(51 mm)
SIDE VIEW END VIEW
H2
(Motor)
MAX. 1/2"
H3
TORRETTA 36
W
2"
(51 mm)
W
5
Jacuzzi Whirlpool Bath K339000X 3/06
SPECIFICATIONS
SPECIFICATIONS (Rectangular) LH = Left Hand, RH = Right Hand
ENGLISH
MODEL
ALLUSION™
6636
RH
ALLUSION™
7236
RH
ALLUSION™
7242
RH
BELLAVISTA™
5
RH
BELLAVISTA™
5.5
RH
BELLAVISTA™
6
RH
CIPREA™
RH
ELARA™ 6042
LH & RH
ELARA™ 6636
LH & RH
ELARA™ 7242
LH & RH
REÁL™
RH
SABELLA™
RH
TORRETTA™ 36 72"(1829 mm) L
66"(1676 mm) L
36"( 914 mm) W
26"( 660 mm) H
72"(1829 mm) L
36"( 914 mm) W
26"( 660 mm) H
72"(1829 mm) L
42"(1067 mm) W
26"( 660 mm) H
60"(1524 mm) L
42"(1067 mm) W
26"( 660 mm) H
66"(1676 mm) L
42"(1067 mm) W
26"( 660 mm) H
72"(1829 mm) L
42"(1067 mm) W
26"( 660 mm) H
72"(1829 mm) L†
48"(1219 mm) W
20-1/2" ( 521 mm) H
60” (1524 mm) L
42” (1067 mm) W
23-1/2” (597 mm) H
66” (1676 mm) L
36” ( 914 mm) W
23-1/2” (597 mm) H
72"(1829 mm) L
42"(1067 mm) W
23-1/2" ( 597 mm) H
72" (1829 mm) L†
42" (1067 mm) W
23" ( 584 mm) H
72" (1829 mm) L
47" (1194 mm) W
23-3/4" ( 584 mm) H
† Add 1/4" to this dimension when roughing-in for 3-wall niche.
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
RapidHeatTM: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.
Motor/Pump: 120 VAC, 20 AMP, 60 Hz. dedicated GFCI protected separate circuit.
HEATER,
INTAKE/DISCHARGE
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
Jacuzzi Whirlpool Bath K339000X 3/06
6
OVAL & ROUND BATHS
SPECIFICATIONS
L
(Heater)
MAX. 2-1/2"
H
W
1/2"
(13 mm)
(Motor)
SIDE VIEW
END VIEW
DUETTA™
(51 mm)
CUTOUT
70" Dia.
(1778 mm)
Hole
Template
Provided
P/N
DA09000
Template
Provided
P/N
DA08000
Template
Provided
P/N
DA07000
Template
Provided
P/N
DA06000
Template
Provided
P/N
P187000
2"
TOTAL WEIGHT/
FLOOR LOADINGDIMENSIONS
1293 lb
(588 kg)/
36 lb/ft
(176 kg/m2 )
999 lb
(454 kg)/
57.1 lb/ft
(278 kg/m2 )
1019 lb
(463 kg)/
61.8 lb/ft
(301 kg/m2 )
1106 lb
(503 kg)/
57.5 lb/ft
(280 kg/m2 )
1277 lb
(581 kg)/
60.8 lb/ft
(296 kg/m2 )
1130 lb
(514 kg)/
54 lb/ft
(263 kg/m2 )
GALLONAGE
2
2
Max - 83 U.S. gal
2
Max - 80 U.S. gal
2
Max - 95 U.S. gal
2
Max - 106 U.S. gal
2
OPERATING
100 U.S. gal
Min - 77 U.S. gal
Min - 75 U.S. gal
Min - 90 U.S. gal
Min - 98 U.S. gal
L
(Heater)
SIDE VIEW
(Motor)
MAX. 1/2"
H
W
END VIEW
VENICIA™
SPECIFICATIONS (Oval & Round) LH = Left Hand, RH = Right Hand
MODEL
CORTINA™
RH
DUETTA™
6042
RH
DUETTA™
6636
RH
DUETTA™
6642
RH
DUETTA™
7242
RH
VENICIA™
RH
72"(1829 mm) L
72"(1829 mm) W
22-1/4" ( 565 mm) H
60” (1524 mm) L
42” (1067 mm) W
26” ( 660 mm) H
66” (1676 mm) L
36” (914 mm) W
26” ( 660 mm) H
66” (1676 mm) L
42” (1067 mm) W
26” (660 mm) H
72" (1829 mm) L
42" (1067 mm) W
26" ( 660 mm) H
72" (1829 mm) L
42" (1067 mm) W
23" ( 584 mm) H
DRAIN/OVERFLOW
DIMENSIONS
16-3/4" (426 mm) A
19-1/4" (489 mm) B
18.4" (467 mm) A
11" (279 mm) B
18.4" (467 mm) A
11" (279 mm) B
18.4" (467 mm) A
11" (279 mm) B
18.4" (467 mm) A
11" (279 mm) B
20" (508 mm) A
14" (356 mm) B
W
(379 liters)
(291 liters)
(314 liters)
(284 liters)
(303 liters)
(341 liters)
(360 liters)
(371 liters)
(401 liters)
90 U.S. gal
(341 liters)
A
B
DRAIN/OVERFLOW
(Heater)
L
(Motor)
CORTINA™
PRODUCT
WEIGHT
210 lb
(95 kg)
110 lb
(50 kg)
180 lb
(82 kg)
117 lb
(53 kg)
130 lb
(59 kg)
130 lb
(59 kg)
SKIRT &
MOUNTING
Not Available
Not AvailableFactory Installed
Not AvailableFactory Installed
Not AvailableFactory Installed
Not AvailableFactory Installed
Not Available
HEATER,
INTAKE/DISCHARGE
Factory Installed
Discharge
(U394000 HEATER)
Intake
(S749000 Heater)
Intake
(S749000 Heater)
Intake
(S749000 Heater)
Intake
(S749000 Heater)
Factory Installed
Intake
(S749000 Heater)
ENGLISH
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4
mm).
FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
RapidHeatTM: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.
Motor/Pump: 120 VAC, 20 AMP, 60 Hz. dedicated GFCI protected separate circuit.
7
Jacuzzi Whirlpool Bath K339000X 3/06
CORNER BATHS
SPECIFICATIONS
ENGLISH
H
SIDE VIEW
(Heater)
MAX. 1/2"
2"
(51 mm)
W
END VIEW
DRAIN/OVERFLOW
BELLAVISTA™ CORNER, Right Hand
SPECIFICATIONS (Corner) LH = Left Hand, RH = Right Hand
SKIRT &
MOUNTING
Not Available
P/N
TOTAL WEIGHT/
FLOOR LOADING
1046 lb
(475 kg)/
42 lb/ft
(205) kg/m
DRAIN/OVERFLOW
MODEL
BELLAVISTA
CORNER
RH
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4
FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
mm).
RapidHeatTM: 120 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.
DIMENSIONS
TM
60"(1524 mm) L
60"(1524 mm) W
21-3/4" ( 553 mm) H
DIMENSIONS
18-7/8" (479 mm) A
14" (356 mm) B
CUTOUT
Template
Provided
P654000
2
2
OPERATING
GALLONAGE
80 U.S. gal
(303 liters)
PRODUCT
WEIGHT
130 lb
(59 kg)
Motor/Pump: 120 VAC, 20 AMP, 60 Hz. dedicated GFCI protected separate circuit.
A
B
HEATER,
INTAKE/DISCHARGE
Factory Installed
Intake
(S749000 Heater)
Jacuzzi Whirlpool Bath K339000X 3/06
8
"
ROUGHING-IN REFERENCE
ROUGHING-IN REFERENCE (RECTANGULAR)
Some tubs are supplied with cutout and/or undermount template. Refer to CUTOUT on pages 6-8 for template part numbers.
66"
72"
ENGLISH
36"
42"
Motor
5" x 5"
ALLUSION™ 6636, Right Hand
72"
Motor
5" x 5"
ALLUSION™ 7242, Right Hand
66"
Motor
42"
4" x 4"
Heater
10"
BELLAVISTA™ 5.5, Right Hand
8-1/2"
Heater
8-1/2"
Heater
35-1/2"
33"
36"
12" H x 18" L
Service Access
6"
Opt. Service Access
12" H x 18" L
Service Access
11-15/16"
Opt. Service
Access
12" H x 18" L
Service Access
11-15/16"
Opt. Service
Access
30-1/8"
11-3/4"
36"
5" x 5"
ALLUSION™ 7236, Right Hand
42"
4" x 4"
7"
BELLAVISTA™ 5, Right Hand
42"
4" x 4"
10-1/2"
BELLAVISTA™ 6, Right Hand
60"
Motor
72"
Motor
8-1/2"
Heater
32-1/2"
Motor
Heater
35-13/16"
Heater
36"
Opt. Service Access
12" H x 18" L
Service Access
11-15/16"
Opt. Service
Access
12" H x 18" L
Service Access
30-1/8"
11-3/4
6"
12" H x 18" L
Service Access
30-1/8"
11-3/4"
6"
Opt. Service
Access
*72"
48"
36"
14" x 4"
Motor
Heater
4"
CIPREA™, Right Hand
* Add 1/4" to this dimension when roughing-in for 3-wall niche.
NOTE: 1. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
2. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
3. Service access dimensions given are minimum size.
4. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
12" H x 18" L
Service Access
34-1/2"
7"
9
Jacuzzi Whirlpool Bath K339000X 3/06
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.