Jacuzzi CETRA WITH INTEGRAL SKIRT, AMIGA, CETRA 532, CETRA 536, CETRA 536 WITH INTEGRAL SKIRT Installation And Operating Instructions Manual

...
BUILDER/COMFORT BATH SERIES
ELECTRONIC & MANUAL CONTROLS
INSTALLATION AND OPERATING INSTRUCTIONS
Owner's Record
Date Purchased ____________________________________________________________
Purchased From ____________________________________________________________
Installed By ________________________________________________________________
Serial Number _____________________________________________________________
Model_____________________________________________________________________
Installer: Leave this manual for homeowner.
Homeowner: Read this manual and keep for future reference.
©
2005 Jacuzzi Whirlpool Bath K272000AF 7/06
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
ENGLISH
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS
WARNING — WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
DANGER — TO REDUCE THE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE THIS UNIT
UNLESS THEY ARE CLOSELY SUPERVISED AT ALL TIMES. WARNING — USE THIS UNIT ONLY FOR ITS INTENDED USE AS DESCRIBED IN THIS MANUAL. DO
NOT USE ATTACHMENTS NOT RECOMMENDED BY THE MANUFACTURER.
WARNING — NEVER DROP OR INSERT ANY OBJECT INTO ANY OPENING. WARNING — DO NOT OPERATE THIS UNIT WITHOUT THE GUARD OVER THE SUCTION FITTING. WARNING — THIS UNIT MUST BE CONNECTED ONLY TO A SUPPLY CIRCUIT THAT IS PROTECTED
BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI). SUCH A GFCI SHOULD BE PROVIDED BY THE INSTALLER AND SHOULD BE TESTED ON A ROUTINE BASIS. TO TEST THE GFCI, PUSH THE TEST BUTTON. THE GFCI SHOULD INTERRUPT POWER. PUSH THE RESET BUTTON. POWER SHOULD BE RESTORED. IF THE GFCI FAILS TO OPERATE IN THIS MANNER, THE GFCI IS DEFECTIVE. IF THE GFCI INTERRUPTS POWER TO THE BATHTUB WITHOUT THE TEST BUTTON BEING PUSHED, A GROUND CURRENT FLOWING, INDICATING A POSSIBILITY OF AN ELECTRIC SHOCK. DO NOT USE THIS HYDROMASSAGE BATHTUB. DISCONNECT THE HYDROMASSAGE BATHTUB AND HAVE THE PROBLEM CORRECTED BY A QUALIFIED SERVICE REPRESENTATIVE BEFORE USING. WARNING — (FOR PERMANENTLY CONNECTED UNITS) A GREEN COLORED TERMINAL (OR A WIRE CONNECTOR MARKED “G”, “GR”, “GROUND”, OR “GROUNDING”) IS PROVIDED WITHIN THE TERMINAL COMPARTMENT. TO REDUCE THE RISK OF ELECTRIC SHOCK, CONNECT THE TERMINAL OR CONNECTOR TO THE GROUNDING TERMINAL OF YOUR ELECTRIC SERVICE OR SUPPLY PANEL WITH A CONDUCTOR EQUIVALENT IN SIZE TO THE CIRCUIT CONDUCTORS SUPPLYING THIS EQUIPMENT.
OPERATING INSTRUCTIONS
WARNING — PROLONGED IMMERSION IN HOT WATER MAY INDUCE HYPERTHERMIA. HYPER-
THERMIA OCCURS WHEN THE INTERNAL TEMPERATURE OF THE BODY REACHES A LEVEL SEV­ERAL DEGREES ABOVE THE NORMAL BODY TEMPERATURE OF 98.6°F. THE SYMPTOMS OF HYPERTHERMIA INCLUDE AN INCREASE IN THE INTERNAL TEMPERATURE OF THE BODY, DIZZI­NESS, LETHARGY, DROWSINESS AND FAINTING. THE EFFECTS OF HYPERTHERMIA INCLUDE:
A) FAILURE TO PERCEIVE HEAT B) FAILURE TO RECOGNIZE THE NEED TO EXIT THE SPA OR HOT TUB, C) UNAWARENESS OF IMPENDING HAZARD, D) FETAL DAMAGE IN PREGNANT WOMEN, E) PHYSICAL INABILITY TO EXIT THE SPA OR HOT TUB, AND F) UNCONSCIOUSNESS RESULTING IN DANGER OF DROWNING.
WARNING — THE USE OF ALCOHOL, DRUGS OR MEDICATION CAN GREATLY INCREASE THE RISK OF FATAL HYPERTHERMIA. WARNING — DO NOT TAMPER WITH USER-OPERATED CONTROLS OR SUCH DEVICES.
Jacuzzi Whirlpool Bath K272000AF 7/06
2
INSTALLATION INSTRUCTIONS
WARNING — WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: DANGER — RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND
FAULT CIRCUIT INTERRUPTER (GFCI). CAUTION — TEST THE GROUND FAULT CIRCUIT INTERRUPTER PROTECTING THIS APPLIANCE PERIODICALLY IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS. WARNING — USE THIS UNIT ONLY FOR ITS INTENDED USE AS DESCRIBED IN THIS MANUAL. DO NOT USE ATTACHMENTS NOT RECOMMENDED BY THE MANUFACTURERS.
WARNING — TO AVOID INJURY, EXERCISE CAUTION WHEN ENTERING OR EXITING THE HYDROMASSAGE BATHTUB. WARNING — KEEP BODY AND HAIR A MINIMUM OF 6" AWAY FROM SUCTION FITTING AT ALL TIMES
WHEN THE HYDROMASSAGE SYSTEM IS OPERATING. HAIR LONGER THAN SHOULDER LENGTH SHOULD BE SECURED CLOSE TO THE HEAD. WARNING — RISK OF ELECTRICAL SHOCK; DO NOT PERMIT ELECTRICAL APPLIANCES (SUCH AS HAIR DRYER, LAMP, TELEPHONE, RADIO OR TELEVISION) WITHIN 60" (1.5 M) OF THIS HYDROMASSAGE BATHTUB. WARNING — RISK OF ACCIDENTAL INJURY OR DROWNING; DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING THE USE OF HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER TO AVOID UNCONSCIOUSNESS AND POSSIBLE DROWNING. WARNING — RISK OF FETAL INJURY; PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER. WARNING — RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; DO NOT USE A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER IMMEDIATELY FOLLOWING STRENUOUS EXERCISE. WARNING — RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; WATER TEMPERATURE IN EXCESS OF 104°F (40°C) MAY BE INJURIOUS TO YOUR HEALTH. CHECK AND ADJUST WATER TEMPERATURE BEFORE USE. WARNING — RISK OF HYPERTHERMIA; PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER.
ENGLISH
FOR BUILT-IN AND DROP-IN UNITS, INSTALL TO PERMIT ACCESS FOR SERVICING. THIS UNIT SHOULD BE ELECTRICALLY GROUNDED AND INSTALLED BY A LICENSED CONTRACTOR,
ELECTRICIAN, AND PLUMBER.
BUILDING MATERIALS AND WIRING SHOULD BE ROUTED AWAY FROM THE MOTOR/PUMP OR
BLOWER OR OTHER HEAT PRODUCING COMPONENTS OF THIS UNIT.
A PRESSURE WIRE CONNECTOR IS PROVIDED ON THE EXTERIOR OF THE MOTOR/PUMP AND HEATER TO PERMIT CONNECTION OF AN NO. 8 AWG (8.4 MM) SOLID COPPER BONDING CONDUCTOR BETWEEN THIS UNIT AND ALL OTHER ELECTRIC EQUIPMENT AND EXPOSED METAL IN THE VICINITY, AS NEEDED TO COMPLY WITH LOCAL REQUIREMENTS.
PRECAUTIONS
••
Do not operate the hydromassage system unless the bath is filled with water to at least 1" to 2" (2,5 - 5,08 cm) above the
••
highest jet.
••
Do not immerse the control panel by overfilling the bath.
••
••
Do not use oil-based bath additives in your hydromassage bath.
••
••
When cleaning your bath, do not use abrasive substances which will damage the bath's surface.
••
••
To prevent discoloration of the acrylic finish, do not fill the bath with water in excess of 140°F (60°C).
••
NOTE: This is a professional grade product. A knowledge of construction techniques, plumbing and electri­cal installation according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath products. Our warranty does not cover improper installation related problems.
PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT.
The Company has obtained applicable code (standards) listings generally available on a national basis for products of this type. It is the responsibility of the installer/owner to determine specific local code compliance prior to installation of the product. The Company makes no representation or warranty regarding, and will not be responsible for any code compliance.
3
Jacuzzi Whirlpool Bath K272000AF 7/06
CONTENTS
Safety Instructions _____________________________________________________________________ 2-3
Contents _____________________________________________________________________________ 4
ENGLISH
Specifications _________________________________________________________________________ 5-9
Roughing-in __________________________________________________________________________ 10-17
Cutout ______________________________________________________________________________ 17
Installation Instructions __________________________________________________________________ 18-24
Framing and Support _________________________________________________________________ 18
Skirts ______________________________________________________________________________ 19
Service Access _____________________________________________________________________ 20
Electrical Connections ________________________________________________________________ 21
Plumbing and Water Supply ___________________________________________________________ 22
Undermount Installation Instructions _____________________________________________________ 23-24
Operation ____________________________________________________________________________ 25-26
Maintenance __________________________________________________________________________ 27
General Troubleshooting Guide ___________________________________________________________ 28
Authorized Service _____________________________________________________________________ 30
Warranty _____________________________________________________________________________ 31-32
NOTE: If you need a referral for a service company near you, or need assistance with operation or maintenance related questions, please call our USA Service Support Department at 1-800-288-4002. Visit our web site at http:/ /www.jacuzzi.com/ for products and services. To find service agent listings for:
Electrical or Mechanical Repairs visit http://jacuzzi.com/pdf/ASA.PDF Finish, Surface, or Shell-Related Repairs visit http://jacuzzi.com/pdf/AFC.PDF Repair Parts or Accessories visit http://jacuzzi.com/pdf/MPD.PDF
Jacuzzi Whirlpool Bath K272000AF 7/06
4
L
1"
(25 mm)
H
W
SIDE VIEW
BATHS WITH INTEGRAL SKIRT
END VIEW
SPECIFICATIONS
Important: Read complete instructions before beginning installation.
Each whirlpool bath arrives ready for installation, completely equipped with motor/pump assembly and plumbing and fittings necessary for whirlpool operation. An optional drain/overflow kit is available for installation on the bath.
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been made. Do
not lift the bath by the plumbing at any time; handle by the shell only.
Immediately upon receipt, inspect the shell before installing. Should inspection reveal any damage or defect in the finish, do not install the bath. Damage or defect to the finish claimed after the bath is installed is excluded from the warranty. Jacuzzi Whirlpool Bath responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. Refer any claims for damage to the carrier. For definitions of warranty coverage and limitations, refer to the published warranty informa­tion packed with the product.
All bath units are factory tested for proper operation and watertight connections prior to shipping. NOTE: Prior to installa-
tion, the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling. Jacuzzi Whirlpool Bath is not responsible for any defect that could have been discovered, repaired, or
avoided by following this inspection and testing procedure.
Not all tubs shown may be available as export units. Export tubs come with MANUAL controls and may come:
• with Pump/motor packaged
• with Pump/motor installed,
• with NO overflow cutout.
Because of the variety of export tub types some instructions may not apply to your unit. Disregard instructions that do not apply to your specific tub.
RECTANGULAR BATHS
L
(51 mm)
separately,
W
2"
H
ENGLISH
SIDE VIEW
BATHS WITHOUT INTEGRAL SKIRT
L
SIDE VIEW
(25 mm)
1"
BATHS WITH 3-SIDED TILE FLANGE
SPECIFICATIONS (Rectangular) LH = Left Hand, RH = Right Hand
MODEL
AMIGA™
LH & RH
AMIGA™ WITH INTEGRAL SKIRT
LH & RH
©
BIANCA
LH
©
CETRA WITH INTEGRAL SKIRT LH & RH
©
CETRA
532
LH & RH
CETRA© 536
LH & RH
DIMENSIONS
72" (1829 mm) L* 36" ( 914 mm) W
20-3/4" ( 533 mm) H
72" (1829 mm) L 36" ( 914 mm) W
20-3/4" ( 533 mm) H
72" (1829 mm) L* 48" (1219 mm) W
20-1/2" ( 521 mm) H
60" (1524 mm) L 32" ( 813 mm) W
20-1/2" ( 521 mm) H
60" (1524 mm) L* 31-7/8" ( 791 mm) W
21-1/4" ( 553 mm) H
60" (1524 mm) L 36" ( 914 mm) W
21-1/4" ( 553 mm) H
*Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche.
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm). FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
(Optional) RapidHeat
TM
: 115 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.
Motor/Pump: 115 VAC, 15 Amp, 60 Hz. dedicated GFCI protected separate circuit.
DRAIN/OVERFLOW
16-7/8" (429 mm) A 14" (356 mm) B
16-7/8" (429 mm) A
*
14" (356 mm) B
16" (406 mm) A 8-1/2" (216 mm) B
17-7/8" (454 mm) A
*
9-3/8" (238 mm) B
18-1/2" ( 470 mm) A 9" ( 229 mm) B
18-1/2" ( 470 mm) A
*
9" ( 229 mm) B
END VIEW
H
DIMENSIONS
W
END VIEW
CUTOUT
70" x 34"
(1778 mm x
864 mm)
70" x 46"
(1778 mm x
1168 mm)
58" x 30-1/4"
(1473 mm x
768 mm)
58" x 34-1/4"
(1473 mm x
870 mm)
NA
NA
TOTAL WEIGHT/
FLOOR LOADING
772 lb
(351 kg)/
2
43 lb/ft
(210 kg/m2)
796 lb
(362 kg)/
2
44 lb/ft
(214 kg/m2)
993 lb
(451 kg)/
2
41 lb/ft
(200 kg/m2)
727 lb
(330 kg)/
2
55 lb/ft
(268 kg/m2)
697 lb
(317 kg)/
2
53 lb/ft
(259 kg/m2)
742 lb
(337 kg)/
2
50 lb/ft
(244 kg/m2)
5
OPERATING
GALLONAGE
50 U.S. gal
(186 liters)
50 U.S. gal
(186 liters)
73 U.S. gal
(276 liters)
46 U.S. gal
(174 liters)
43 U.S. gal
(163 liters)
48 U.S. gal
(181 liters)
A
B
DRAIN/OVERFLOW
HEATER READY
PRODUCT
WEIGHT
105 lb
(48 kg)
129 lb
(59 kg)
135 lb
(61 kg)
94 lb
(43 kg)
89 lb
(41 kg)
92 lb
(42 kg)
SKIRT &
MOUNTING
Optional, U-Frame
Integral
Optional, U-Frame
Integral
Optional
U-Frame
Optional
U-Frame
FOR FIELD
INSTALLATION
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Jacuzzi Whirlpool Bath K272000AF 7/06
SPECIFICATIONS
SPECIFICATIONS (Rectangular) LH = Left Hand, RH = Right Hand
HEATER READY
PRODUCT
WEIGHT
92 lb
(42 kg)
80 lb
(36 kg)
100 lb
(45 kg)
90 lb
(41 kg)
95 lb
(43 kg)
95 lb
(43 kg)
104 lb
(47 kg)
114 lb
(52 kg)
100 lb
(45 kg)
110 lb
(50 kg)
97 lb
(44 kg)
SKIRT &
MOUNTING
IntegralNA
Optional, U-Frame
Integral
Optional, U-Frame
Integral
Not
Available
Not
Available
Integral
Optional, U-Frame
Not
Available
Optional, U-Frame
2
2
2
2
2
2
2
2
2
2
2
OPERATING
GALLONAGE
48 U.S. gal
(181 liters)
44 U.S. gal
(167 liters)
42 U.S. gal
(159 liters)
58 U.S. gal (220 liters)
38 U.S. gal
(144 liters)
46 U.S. gal
(172 liters)
70 U.S. gal
(265 liters)
70 U.S. gal
(265 liters)
62 U.S. gal
(235 liters)
76 U.S. gal
(288 liters)
46 U.S. gal (170 liters)
NA
NA
NALUXURA™ 530
NA
TOTAL WEIGHT/
FLOOR LOADING
742 lb
(337 kg)/
50 lb/ft
(244 kg/m2)
697 lb
(264 kg)/
52 lb/ft
(254 kg/m2)
700 lb
(318 kg)/
53 lb/ft
(259 kg/m2)
823 lb
(374 kg)/
53 lb/ft
(259 kg/m2)
662 lb
(301 kg)/
53 lb/ft
(259 kg/m2)
728 lb
(331 kg)/
42 lb/ft
(205 kg/m2)
937 lb
(423 kg)/
44 lb/ft
(215 kg/m2)
947 lb
(430 kg)/
45 lb/ft
(220 kg/m2)
866 lb
(394 kg)/
50 lb/ft
(244 kg/m2)
993 lb
(451 kg)/
47 lb/ft
(229 kg/m2)
722 lb
(328 kg)/
41 lb/ft
(200 kg/m2)
MODEL
CETRA© 536 WITH INTEGRAL SKIRT
ENGLISH
LH & RH
LUXURA™ 5 WITH INTEGRAL 3-SIDED TILE FLANGE LH & RH
LUXURA™ 5 WITH INTEGRAL SKIRT LH & RH
LUXURA™ 5.5
LH & RH
WITH INTEGRAL SKIRT LH & RH
MAJORA© 5
LH & RH
MAJORA© 6
LH & RH
©
6
MAJORA WITH INTEGRAL SKIRT LH & RH
©
5
MITO
LH & RH
MITO© 6
LH & RH
©
5
NOVA
LH & RH
DIMENSIONS
60" (1524 mm) L* 36" ( 914 mm) W
21-1/4" ( 553 mm) H
60" (1524 mm) L 32" ( 813 mm) W
20-1/4" ( 514 mm) H
60" (1524 mm) L 32" ( 813 mm) W 20-1/4" ( 514 mm) H
66" (1676 mm) L 34" ( 864 mm) W
20" ( 508 mm) H
60" (1524 mm) L* 30" ( 762 mm) W
20-1/4" ( 483 mm) H
60" (1524 mm) L* 42" (1067 mm) W
19-1/2" ( 495 mm) H
72" (1829 mm) L* 42" (1067 mm) W
19-3/4" ( 502 mm) H
72" (1829 mm) L 42" (1067 mm) W
19-3/4" ( 502 mm) H
60" (1524 mm) L 42" (1067 mm) W
21" ( 533 mm) H
72" (1829 mm) L* 42" (1067 mm) W
21-1/2" ( 546 mm) H
60" (1524 mm) L 42" (1067 mm) W
18-1/2" ( 470 mm) H
DRAIN/OVERFLOW
DIMENSIONS
18-1/2" ( 470 mm) A 9" ( 229 mm) B
*
15-1/4" (387 mm) A 8-1/4" (210 mm) B
15-1/4" (387 mm) A 8-1/4" (210 mm) B
*
15-1/4" (387 mm) A 8-3/8" (213 mm) B
16-3/4" (425 mm) A 9-1/4" (235 mm) B
15" (381 mm) A 8-3/4" (222 mm) B
15-5/8" (397 mm) A 10-1/2" (267 mm) B
15-5/8" (397 mm) A
*
10-1/2" (267 mm) B
17-1/2" (445 mm) A
*
11-7/8" (302 mm) B
17-1/2" (445 mm) A 11-7/8" (302 mm) B
14-3/4" (375 mm) A
*
8-1/2" (216 mm) B
CUTOUT
Molded-in
Tile Flange
64" x 32"
(1626 mm x
813 mm)
58" x 40"
(1473 mm x
1016 mm)
70" x 40"
(1778 mm x
1016 mm)
58" x 40"
(1473 mm x
1016 mm)
70" x 40"
(1778 mm x
1016 mm)
58" x 40"
(1473 mm x
1016 mm)
FOR FIELD
INSTALLATION
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(U395000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
*Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche.
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm). FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
(Optional) RapidHeatTM: 115 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit. Motor/Pump: 115 VAC, 15 Amp, 60 Hz. dedicated GFCI protected separate circuit.
Jacuzzi Whirlpool Bath K272000AF 7/06
6
SPECIFICATIONS
SPECIFICATIONS (Rectangular) LH = Left Hand, RH = Right Hand
MODEL
©
5
NOVA WITH INTEGRAL 3-SIDED TILE FLANGE LH & RH
©
NOVA
5 WITH INTEGRAL SKIRT LH & RH
©
6
NOVA
LH & RH
©
NOVA
536
LH & RH
©
536
NOVA WITH INTEGRAL SKIRT LH & RH
©
636
NOVA WITH INTEGRAL SKIRT LH & RH
©
SIGNA
5
LH & RH
©
5 WITH
SIGNA INTEGRAL SKIRT, FRONT RIGHT MOTOR/PUMP LH & RH
SIGNA© 5 WITH INTEGRAL 3-SIDED TILE FLANGE RH
SIGNA© 6
LH & RH
DIMENSIONS
60" (1524 mm) L* 42" (1067 mm) W
18-1/2" ( 470 mm) H
60" (1524 mm) L* 42" (1067 mm) W
18-1/2" ( 470 mm) H
72" (1829 mm) L 42" (1067 mm) W
20-1/2" ( 521 mm) H
60" (1524 mm) L 36" ( 914 mm) W
19-1/4" ( 489 mm) H
60" (1524 mm) L* 36" ( 914 mm) W
19-1/4" ( 489 mm) H
72" (1829 mm) L 36" ( 914 mm) W
19" ( 483 mm) H
60" (1524 mm) L* 42" (1067 mm) W
22" ( 559 mm) H
60" (1524 mm) L 42" (1067 mm) W
22" ( 559 mm) H
60" (1524 mm) L 42" (1067 mm) W
22" ( 559 mm) H
72" (1829 mm) L* 42" (1067 mm) W
22" ( 559 mm) H
DRAIN/OVERFLOW
DIMENSIONS
14-3/4" (375 mm) A 8-1/2" (216 mm) B
15-7/8" (403 mm) A 9-1/4" (235 mm) B
14-3/4" (375 mm) A
*
8-1/2" (216 mm) B
15-1/8" (384 mm) A
*
9" (229 mm) B
14-5/8" (372 mm) A 9" (229 mm) B
14-5/8" (372 mm) A
*
9-3/8" (238 mm) B
17-1/2" (445 mm) A 12-1/2" (318 mm) B
17-7/8" (451 mm) A
*
12-3/4" (330 mm) B
*
17-1/2" (445 mm) A 12-1/2" (318 mm) B
16-7/8" (429 mm) A 14" (356 mm) B
TOTAL WEIGHT/
CUTOUT
Molded-in
Tile Flange
70" x 40"
(1778 mm x
1016 mm)
58" x 34"
(1473 mm x
863 mm)
58" x 40"
(1473 mm x
1016 mm)
70" x 40"
(1778 mm x
1016 mm)
FLOOR LOADING
NA
NA
NA
NA
NA Yes
NA
722 lb
(328 kg)/
41 lb/ft
(200 kg/m2)
737 lb
(335 kg)/
42 lb/ft
(205 kg/m2)
876 lb
(398 kg)/
42 lb/ft
(205 kg/m2)
683 lb
(310 kg)/
46 lb/ft
(224 kg/m2)
698 lb
(317 kg)/
47 lb/ft
(229 kg/m2)
824 lb
(375 kg)/
45.8 lb/ft
(223 kg/m2)
708 lb
(321 kg)/
40 lb/ft
(195 kg/m2)
723 lb
(329 kg)/
41 lb/ft
(200 kg/m2)
708 lb
(321 kg)/
40 lb/ft
(195 kg/m2)
826 lb
(375 kg)/
39 lb/ft
(190 kg/m2)
2
2
2
2
2
2
2
2
2
2
OPERATING
GALLONAGE
46 U.S. gal
(174 liters)
45 U.S. gal
(174 liters)
62 U.S. gal (235 liters)
42 U.S. gal
(159 liters)
42 U.S. gal (159 liters)
56 U.S. gal (223 liters)
42 U.S. gal (159 liters)
42 U.S. gal
(159 liters)
42 U.S. gal
(159 liters)
55 U.S. gal
(208 liters)
PRODUCT
WEIGHT
97 lb
(44 kg)
112 lb
(51 kg)
110 lb
(50 kg)
83 lb
(38 kg)
98 lb
(45 kg)
108 lb
(49 kg)
108 lb
(49 kg)
123 lb
(56 kg)
108 lb
(49 kg)
118 lb
(54 kg)
SKIRT &
MOUNTING
Not
Available
Integral
Optional, U-Frame
Not
Available
Integral
Integral
Optional, U-Frame
Integral
Optional, U-Frame
Not
Available
HEATER READY
(S750000 HEATER KIT)
(S750000 HEATER KIT)
(S750000 HEATER KIT)
(S750000 HEATER KIT)
(S750000 HEATER KIT)
(S750000 HEATER KIT)
(U395000 HEATER KIT)
(S750000 HEATER KIT)
(S750000 HEATER KIT)
FOR FIELD
INSTALLATION
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
ENGLISH
*Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche.
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm). FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
(Optional) RapidHeat
TM
: 115 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.
Motor/Pump: 115 VAC, 15 Amp, 60 Hz. dedicated GFCI protected separate circuit.
7
Jacuzzi Whirlpool Bath K272000AF 7/06
RIMLESS OVAL BATHS
DRAIN/OVERFLOW
A
B
END VIEW
H
W
SIDE VIEW
L
2"
(51 mm)
LUNA
SPECIFICATIONS
END VIEW
W
W
3-1/2"
(89 mm)
L
2'' (51 mm)
SIDE VIEW
8"
(203 mm)
W
H
END VIEW
MILANO
2''
(51 mm)
L
7-1/2"
H
ENGLISH
(191 mm)
2"
(51 mm)
SIDE VIEW
FRESCO
L
H
SIDE VIEW
GALLERY 5 OVAL & GALLERY 6 OVAL
RIVA 5 & RIVA 6
END VIEW
SPECIFICATIONS (Oval) LH = Left Hand, RH = Right Hand
HEATER READY
FOR FIELD
INSTALLATION
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
Yes
(S750000 HEATER KIT)
MODEL
©
FRESCO
LH & RH
GALLERY™ 5 OVAL
LH & RH
GALLERY™ 6 OVAL
LH & RH
GALLERY™ 6 OVAL
UNDERMOUNT
LH & RH
LUNA™
RH
MILANO™
LH & RH
OPALIA™
LH & RH
©
5
RIVA
LH & RH
RIVA© 6
LH & RH
DIMENSIONS
71-1/2" (1816 mm) L 42" (1067 mm) W 27-1/4" ( 692 mm) H*
62" (1575 mm) L 43" (1092 mm) W 19" ( 483 mm) H
72" (1829 mm) L 42" (1067 mm) W 20-1/2" ( 521 mm) H
72" (1829 mm) L 42" (1067 mm) W 20-1/2" ( 521 mm) H
72" (1829 mm) L 42" (1067 mm) W 23" ( 584 mm) H
72" (1829 mm) L 40" (1016 mm) W 20-3/4" ( 527 mm) H
72" (1829 mm) L 44" (1118 mm) W 22-1/4" ( 565 mm) H
62" (1575 mm) L 43" (1092 mm) W 19" ( 483 mm) H
72" (1829 mm) L 42" (1067 mm) W 20-1/2" ( 521 mm) H
DRAIN/OVERFLOW
DIMENSIONS
20-1/8" (511 mm) A 11-3/4" (299 mm) B
14-3/4" (375 mm) A 9-1/2" (241 mm) B
16" (406 mm) A 11-1/2" (292 mm) B
16" (406 mm) A 11-1/2" (292 mm) B
19-1/8" (486 mm) A 11" (279 mm) B
18-1/2" (470 mm) A 11" (279 mm) B
18-3/4" (476 mm) A 12" (305 mm) B
14-3/4" (375 mm) A 9-1/2" (241 mm) B
16" (406 mm) A 11-1/2" (292 mm) B
CUTOUT
Template Provided
P/N
P188000
Template Provided
P/N
P186000
Template
Provided
P/N
P186000
Template
Provided
P/N
X302000
Template Provided
P/N
P819000
Template
Provided
P/N
P188000
Template
Provided
P/N
P186000
Template
Provided
P/N
P186000
Template
Provided
P/N
P186000
TOTAL WEIGHT/ FLOOR LOADING
921 lb
(419 kg)/
2
44 lb/ft
(220 kg/m2)
746 lb
(339 kg)/
2
40 lb/ft
(195 kg/m2)
871 lb
(395 kg)/
2
42 lb/ft
(205 kg/m2)
871 lb
(395 kg)/
2
42 lb/ft
(205 kg/m2)
1221 lb
(555 kg)/
2
58 lb/ft
(283 kg/m2)
893 lb
(406 kg)/
2
45 lb/ft
(220 kg/m2)
978 lb
(445 kg)/
2
45 lb/ft
(220 kg/m2)
746 lb
(339 kg)/
2
40 lb/ft
(195 kg/m2)
871 lb
(396 kg)/
2
42 lb/ft
(205 kg/m2)
OPERATING
GALLONAGE
63 U.S. gal
(239 liters)
48 U.S. gal
(182 liters)
62 U.S. gal (235 liters)
62 U.S. gal (235 liters)
96 U.S. gal (364 liters)
60 U.S. gal
(227 liters)
70 U.S. gal (265 liters)
48 U.S. gal (182 liters)
62 U.S. gal (235 liters)
PRODUCT
WEIGHT
146 lb
(66 kg)
96 lb
(44 kg)
105 lb
(48 kg)
105 lb
(48 kg)
121 lb
(55 kg)
143 lb
(65 kg)
145 lb
(66 kg)
96 lb
(44 kg)
105 lb
(48 kg)
SKIRT &
MOUNTING
Not
Available
Not
Available
Not
Available
Not
Available
Not
Available
Not
Available
Not
Available
Not
Available
Not
Available
* For Fresco models H551, H549, and H550 this height is 23-3/4"
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm). FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
(Optional) RapidHeat Motor/Pump: 115 VAC, 15 Amp, 60 Hz. dedicated GFCI protected separate circuit.
Jacuzzi Whirlpool Bath K272000AF 7/06
TM
: 115 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit.
8
CORNER BATHS
SPECIFICATIONS
2"
(51 mm)
DRAIN/OVERFLOW
SIDE VIEW
H
END VIEW
CORNER BATH
1"
(25 mm)
H
FRONT VIEW
CAPELLA 55, CAPELLA 60, & TARA WITH INTEGRAL SKIRT
H
FRONT VIEW
CAPELLA SPACESAVER WITH INTEGRAL SKIRT
SIDE VIEW
1" (25 mm)
SPECIFICATIONS (Corner) LH = Left Hand, RH = Right Hand
MODEL
©
CAPELLA
RH
CAPELLA WITH INTEGRAL SKIRT RH
CAPELLA SPACESAVER WITH INTEGRAL SKIRT RH
CAPELLA FRONT LEFT MOTOR/PUMP LH
CAPELLA© 60
LH & RH
CAPELLA WITH INTEGRAL SKIRT RH
GALLERY™ CORNER
LH & RH
TARA™
LH & RH
TARA™ WITH INTEGRAL SKIRT RH
55
©
55
©
©
60
©
60
DIMENSIONS
55" (1397 mm) L 55" (1397 mm) L 20-1/4" ( 514 mm) H
55" (1397 mm) L 55" (1397 mm) L 20-1/2" ( 521 mm) H
60" (1524 mm) L 60" (1524 mm) L 20-1/2" ( 521 mm) H
60" (1524 mm) L 60" (1524 mm) L 20-1/2" ( 521 mm) H
60" (1524 mm) L 60" (1524 mm) L 20-1/2" ( 521 mm) H
60" (1524 mm) L 60" (1524 mm) L 20-1/2" ( 521 mm) H
60" (1524 mm) L 60" (1524 mm) L 22-1/2" ( 572 mm) H
60" (1524 mm) L 60" (1524 mm) L 20-3/4" ( 527 mm) H
60" (1524 mm) L 60" (1524 mm) L 20-3/4" ( 527 mm) H
DRAIN/OVERFLOW
DIMENSIONS
17-1/2" (445 mm) A 9-5/8" (245 mm) B
18" (457 mm) A 12-1/8" (308 mm) B
18" (457 mm) A 12-3/8" (308 mm) B
18" (457 mm) A 12-1/8" (308 mm) B
18" (457 mm) A 12-1/8" (308 mm) B
18" (457 mm) A 12-1/8" (308 mm) B
18-1/8" (451 mm) A 12" (305 mm) B
16" (406 mm) A 12-3/8" (314 mm) B
16" (406 mm) A 12-3/8" (314 mm) B
CUTOUT
Template
Provided
P/N
DA24000
NA
NA
See
Page 17
See
Page 17
NA
See
Page 17
See
Page 17
NA
TOTAL WEIGHT/ FLOOR LOADING
791 lb
(360 kg)/
2
38 lb/ft
(185 kg/m2)
1025 lb
(466 kg)/
2
48.8 lb/ft
(238 kg/m2)
880 lb
(400 kg)/
2
35 lb/ft
(171 kg/m2)
870 lb
(395 kg)/
2
35 lb/ft
(171 kg/m2)
870 lb
(395 kg)/
2
35 lb/ft
(171 kg/m2)
880 lb
(400 kg)/
2
35 lb/ft
(171 kg/m2)
984 lb
(447 kg)/
2
39 lb/ft
(244 kg/m2)
984 lb
(447 kg)/
2
39 lb/ft
(190 kg/m2)
999 lb
(454 kg)/
2
40 lb/ft
(195 kg/m2)
OPERATING
GALLONAGE
51 U.S. gal
(193 liters)
54 U.S. gal
(204 liters)
60 U.S. gal
(227 liters)
60 U.S. gal
(227 liters)
60 U.S. gal
(227 liters)
60 U.S. gal
(227 liters)
74 U.S. gal (280 liters)
74 U.S. gal
(280 liters)
74 U.S. gal
(280 liters)
PRODUCT
WEIGHT
116 lb
(53 kg)
125 lb
(57 kg)
130 lb
(59 kg)
120 lb
(54 kg)
120 lb
(54 kg)
130 lb
(59 kg)
118 lb
(54 kg)
118 lb
(54 kg)
133 lb
(61 kg)
NOTE: The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm). FOR ALL UNITS: Electrical Service Requirements: All require a dedicated GFCI protected separate circuit.
(Optional) RapidHeatTM: 115 VAC, 15 AMP, 60 Hz. dedicated GFCI protected separate circuit. Motor/Pump: 115 VAC, 15 Amp, 60 Hz. dedicated GFCI protected separate circuit.
SKIRT &
MOUNTING
Optional
Integral
Integral
Not
Available
Not
Available
Integral
Not
Available
Optional
Integral
A
B
SIDE VIEW
(S750000 HEATER KIT)
(S750000 HEATER KIT)
(S750000 HEATER KIT)
HEATER READY
FOR FIELD
INSTALLATION
Yes
No
No
No
No
No
Yes
Yes
No
ENGLISH
9
Jacuzzi Whirlpool Bath K272000AF 7/06
ROUGHING-IN REFERENCE (RECTANGULAR)
*60"
32"
CETRA™ W/INTEGRAL SKIRT, Left Hand
15-5/8"
2"
10" x 4"
9-3/8"
5-11/16"
Motor
9"
CETRA™ 532, Right Hand
12" x 4"
Motor
2"
5-3/4"
12" H x 18" L
Service Access
Opt. Service Access
*60"
32"
16"
9"
CETRA™ 536 WITH INTEGRAL SKIRT, Left Hand
*60"
36"
17-3/8"
12" x 4"
2"5-3/4"
Motor
"
*72''
Motor
ROUGHING-IN
*72''
*72''
18''
Motor
16'' x 4''
36''
ENGLISH
11-1/8''
2''
14''
AMIGA™, Left Hand
Motor
*72''
16'' x 4''
2''
14-1/2''
AMIGA WITH INTEGRAL SKIRT,
Right Hand
*60"
10" x 4"
32"
Motor
2"
9-3/8"
CETRA™ W/INTEGRAL SKIRT, Right Hand
*60"
Opt. Service Access
15-5/8"
5-11/16"
17-3/8''
36''
11-1/8''
12" H x 18" L
Service Access
12" H x 18" L
Service Access
24"
48"
8-1/2"
32"
16"
5-3/4"
9"
16'' x 4''
Opt. Service Access
AMIGA™, Right Hand
*72"
13-1/2" x 4"
Motor
2"
13-3/4"
(Left-hand only as shown)
BIANCA™
*60"
12" x 4"
2"
CETRA™ 532, Left Hand
2''
14''
Motor
*60"
18''
11-1/8''
Opt. Service Access
Opt. Service Access
36''
12" H x 18" L
Service Access
12" H x 18" L
Service Access
17-3/8"
Motor
16'' x 4''
36''
11-1/8''
2''
14-1/2"
AMIGA WITH INTEGRAL SKIRT,
Left Hand
12" x 4"
36"
Motor
18"
5-3/4"
2"
9"
Opt. Service Access
CETRA™ 536, Left Hand
*60"
17-3/8"
5-3/4"
36"
12" x 4"
Motor
2"
9"
CETRA™ 536 WITH INTEGRAL SKIRT, Right Hand
*Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche. NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.
Jacuzzi Whirlpool Bath K272000AF 7/06
12" H x 18" L
Service Access
12" H x 18" L
Service Access
Opt. Service Access
16"
32"
2-1/2"
5-1/4"
12" x 4"
Motor
2" 5-3/4"
CETRA™ 536, Right Hand
*60"
8-1/4"
12" x 5"
Motor
2-1/2"
Opt. Service Access
LUXURA™ 5, Left Hand
10
36"
18"
9"
*60"
8-1/4"
16"
32
2-1/2"
5-1/4"
12" H x 18" L
Service Access
12" H x 18" L
Service Access
Opt. Service Access
15" x 5"
Motor
2-1/2"
LUXURA™ 5, Right Hand
"
s
O
ROUGHING-IN REFERENCE (RECTANGULAR)
12" x 5"
2-1/2"
*66"
17"
34"
8-3/8"
LUXURA™ 5.5, Left Hand
Motor
12" H x 18" L
Service Access
Opt. Service Access
2-1/2"
5-3/8"
LUXURA™ 530 WITH INTEGRAL SKIRT, Right Hand
2-1/2"
*60"
14-3/8"
30"
12" x 5"
9-1/4"
Motor
2-1/2"
5-7/8"
MAJORA™ 6, Left Hand
42"
*72"
12" x 4"
21"
2"
10-1/2"
Motor
12" H x 18" L
Service Access
Opt. Service Access
4-3/8"
*60"
8-1/4"
15-3/8"
2-1/2"
5-1/4"
LUXURA™ 5 WITH INTEGRAL SKIRT, Left Hand
12" x 5"
2-1/2"
*66"
Motor
8-3/8"
32"
32"
LUXURA™ 5 WITH INTEGRAL SKIRT, Right Hand
ROUGHING-IN
*60"
8-1/4"
12" x 5"
Motor
2-1/2"
*60"
9-1/4"
15-3/8"
2-1/2"
5-1/4"
ENGLISH
12" H x 18" L
Service Access
Opt. Service Access
8-3/4"
21"
42"
12" H x 18" L
Service Access
12" x 5"
Motor
2-1/2"
LUXURA™ 5.5, Right Hand
*60"
2"
10" x 4"
Motor
4-3/8"
Opt. Service Access
MAJORA™ 5, Left Hand
*72"
2"
12" x 4"
Motor
17"
34"
2-1/2"
5-3/8"
12" H x 18" L
Service Access
10-1/2"
21"
42"
14-3/8"
12" x 5"
Motor
30"
2-1/2"
5-7/8"
2-1/2"
LUXURA™ 530 WITH INTEGRAL SKIRT, Left Hand
*60"
8-3/4"
2"
21"
12" H x 18" L
Service Access
Opt. Service Access
10" x 4"
Motor
4-3/8"
42"
MAJORA™ 5, Right Hand
8-1/2"
*72"
2"
20-1/2"
12" x 4"
Motor
42"
42"
*72"
12" x 4"
Motor
2"
8-1/2"
20-1/2"
Opt. Service Access
4-3/8"
MAJORA™ 6, Right Hand
12" H x 18" L Service Access
Opt. Service
Access
*60"
10" x 4"
42"
Motor
2"
11-7/8
5-3/8"
30"
MITO™ 5, Left Hand
*Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche. NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.
4-3/8"
MAJORA™ 6 W/INTEGRAL SKIRT, Left Hand
pt. Service
*60"
Access
10" x 4"
Motor
11-7/8"
2"
30"
MITO™ 5, Right Hand
11
12" H x 18" L Service Acces
42"
5-3/8"
4-3/8"
MAJORA™ 6 W/INTEGRAL SKIRT, Right Hand
12" H x 18" L Service Access
Opt. Service
Access
*72"
10" x 4"
42"
Motor
5-3/8"
2"
36"
MITO™ 6, Left Hand
Jacuzzi Whirlpool Bath K272000AF 7/06
11-7/8"
ROUGHING-IN REFERENCE (RECTANGULAR)
"
s
NOVA™ 5, Right Hand
*60"
21"
42"
11" x 4"
Motor
12" H x 18" L Service Access
Opt. Service Access
2''
8-1/2''
5-3/8''
NOVA™ 5 WITH INTEGRAL SKIRT, Left Hand
*60"
21"
42"
11" x 4"
9-1/4"
2''
5-1/4''
Motor
NOVA™ 6, Left Hand
*72"
21"
2"
42"
14" x 4"
8-1/2"
Motor
12" H x 18" L
Service Access
Opt. Service Access
6-7/8"
Opt. Service
Access
12" H x 18" L Service Access
ENGLISH
11-7/8"
*72"
10" x 4"
2"
Motor
42"
ROUGHING-IN
*60"
21"
11" x 4"
Motor
12
H x 18" L
Service Acces
42"
36"
5-3/8"
MITO™ 6, Right Hand
12" H x 18" L Service Access
21"
*60"
11" x 4"
42"
Motor
7''
8-1/2''
2''
Opt. Service Access
NOVA™ 5 W/3-SIDED TILE FLANGE, Left Hand
*60"
11" x 4"
21"
42"
Motor
2''
5-1/4''
9-1/4"
NOVA™ 5 WITH INTEGRAL SKIRT, Right Hand
5-3/8''
8-1/2''
12" H x 18" L Service Access
2''
NOVA™ 5, Left Hand
Opt. Service Access
*60"
11" x 4"
21"
42"
Motor
Opt. Service Access
2''
7''
8-1/2''
NOVA™ 5 W/3-SIDED TILE FLANGE, Right Hand
*60"
18"
36"
4-5/8"
9"
10" x 4"
Motor
2"
Opt. Service Access
NOVA™ 536, Left Hand
12" H x 18" L
Service Access
12" H x 18" L
Service Access
Opt. Service Access
NOVA™ 536, Right Hand
*60"
10" x 4"
Motor
18"
36"
2"
4-5/8"
9"
*60"
18"
4-5/8"
10" x 4"
Motor
9"
2"
36"
NOVA™ 536 W/INTEGRAL SKIRT, Left Hand
*72"
14" x 4"
21"
42"
12" H x 18" L
Service Access
Opt. Service Access
*Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche. NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.
Jacuzzi Whirlpool Bath K272000AF 7/06
Motor
2"
NOVA™ 6, Right Hand
6-7/8"
8-1/2"
*60"
36"
10" x 4"
Motor
2"
NOVA™ 536 W/INTEGRAL SKIRT, Right Hand
*72"
9-3/8"
17-7/8"
6-7/8"
10" x 4"
Motor
2"
NOVA™ 636 W/INTEGRAL SKIRT, Left Hand
12
18"
4-5/8"
9"
*72"
36"
36"
10" x 4"
Motor
NOVA™ 636 W/INTEGRAL SKIRT, Right Hand
9-3/8"
2"
17-7/8"
6-7/8"
ROUGHING-IN REFERENCE (RECTANGULAR)
ROUGHING-IN
*60"
42"
12"
5"
12" H x 18" L
Service Access
Opt.
Service
Access
13" x 5"
Motor
4-1/4"
30"
SIGNA™ 5, Left Hand
*60"
4-1/4"
13" x 5"
Motor
30"
Opt.
Service
Access
42"
12"
5"
SIGNA™ 5 W/3-SIDED TILE FLANGE, Right Hand
*72"
42"
18-1/2" x 5"
Motor
12" H x 18" L
Service Access
12" H x 18" L
Service Access
*60"
42"
12"
5"
13" x 5"
Motor
4-1/4"
30"
SIGNA™ 5, Right Hand
*60"
42"
6-3/4"
16" x 5"
4-1/4"
Motor
30"
(Right hand only as shown)
SIGNA™ 5 W/INTEGRAL SKIRT
12" H x 18" L
Opt.
Service
Access
12-3/4"
*60"
13" x 5"
Motor
30"
Service Access
12" H x 18" L
Service Access
Opt.
Service
Access
SIGNA™ 5 W/3-SIDED TILE FLANGE, Left Hand
*72"
18-1/2" x 5"
12" H x 18" L
Service Access
Motor
12-1/2"
Opt.
Service
Access
36"
SIGNA™ 6, Left Hand
4-1/4"
11-
ENGLISH
42"
12"
5"
42"
1/4"
5"
1/4"
11-
5"
SIGNA™ 6, Right Hand
36"
12-1/2"
Opt.
Service
Access
*Add 1/4" (6,4 mm) to this dimension when roughing-in for 3-wall niche. NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.
13
Jacuzzi Whirlpool Bath K272000AF 7/06
s
s
"
s
ROUGHING-IN
ROUGHING-IN REFERENCE (OVAL)
NOTE: These units have been provided with cutout templates included in shipping carton.
See CUTOUT information for each model on page 8.
ENGLISH
42"
12" H x 18" L Service Access
12" x 4"
Motor
35-3/4"
71-1/2"
FRESCO™, Left Hand
4-1/2"
2"
4-1/2"
11-3/4"
11-3/4"
FRESCO™, Right Hand
62"
21-1/2"
12" x 4"
5"
9-1/2"
2"
GALLERY™ 5 OVAL, Left Hand
Motor
12" H x 18" L Service Access
43"
43"
12" H x 18" L Service Access
GALLERY™ 5 OVAL, Right Hand
2"
71-1/2"
62"
12" x 4"
Motor
12" x 4"
Motor
35-3/4"
2"
21-1/2"
5"
9-1/2"
42"
12" H x 18" L Service Access
72"
72"
21"
6-7/8"
14" x 4"
Motor
2"
11-1/2"
GALLERY™ 6, Left Hand
12" H x 18" L Service Access
42"
42"
12" H x 18" L Service Access
GALLERY™ 6, Right Hand
14" x 4"
Motor
2"
21"
6-7/8"
11-1/2"
12-1/2"
2"
12" H x 18" L
Service Acces
14" x 4"
Motor
42"
21"
72"
GALLERY 6 UNDERMOUNT, Left Hand
72"
12" H x 18" L
13" X 6"
3"
Motor
11"
(Right-hand only)
LUNA™
36"
Service Acces
42
11"
20"
40"
71-1/2"
2"
12" x 4"
Motor
5"
MILANO™, Left Hand
NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.
2"
12" H x 18" L
Service Acces
42"
14" x 4"
Motor
72"
GALLERY 6 UNDERMOUNT, Right Hand
71-1/2"
12" x 4"
12" H x 18" L
Service Access
12" H x 18" L
Service Access
Motor
MILANO™, Right Hand
12-1/2"
21"
2"
5"
11"
20"
40"
Jacuzzi Whirlpool Bath K272000AF 7/06
14
ROUGHING-IN
ROUGHING-IN REFERENCE (OVAL)
NOTE: These units have been provided with cutout templates included in shipping carton.
See CUTOUT information for each model on page 8.
72"
72"
ENGLISH
44"
Motor
12" H x 18" L Service Access
21-1/2"
5"
9-1/2"
21"
13" X 4"
3"
4"
4-11/16"
OPALIA™, Left Hand
62"
12" x 4"
Motor
2"
RIVA™ 5, Left Hand
72"
14" x 4"
Motor
36"
12" H x 18" L Service Access
32"
12"
42"
43"
32"
12"
43"
13" X 4"
3"
4-11/16"
36"
OPALIA™, Right Hand
12" x 4"
Motor
12" H x 18" L Service Access
RIVA™ 5, Right Hand
42"
62"
4"
14" x 4"
Motor
2"
72"
44"
Motor
12" H x 18" L Service Access
21-1/2"
5"
9-1/2"
21"
6-7/8"
2"
11-1/2"
RIVA™ 6, Left Hand
12" H x 18" L Service Access
12" H x 18" L Service Access
RIVA™ 6, Right Hand
2"
11-1/2"
6-7/8"
NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.
15
Jacuzzi Whirlpool Bath K272000AF 7/06
ROUGHING-IN REFERENCE (CORNER)
"
CAPELLA™ 60, Right Hand
27"
46-5/8"
27"
60"
43-1/8"
6"
60"
34-15/16"
14" X 4"
33-1/2"
Motor
Service Access
Opt.
Service
Access
GALLERY™ CORNER, Right Hand
60"
24"
24"
34"
47-3/4"
19" X 4"
7-1/2"
13"
34"
60"
50-1/4"
Motor
Service Access
Opt.
Service
Access
ROUGHING-IN
ENGLISH
36 1/2"
27"
34-15/16"
43-1/8"
55"
27"
- 2" x 4" Stud
(Right-hand only as shown)
33-1/2"
60"
12" x 4"
Motor
39 1/2"
CAPELLA™ 55
14" X 4"
46-5/8"
55"
6"
12" H x 18" L Service Access
27"
36 1/2"
44 1/2"
60"
27"
12" H x 18" L
Service Access
Opt.
Service
Access
61-1/2
Ref.
29-3/8"
12" H x 18" L
Service
Access
34-15/16"
32-1/4"
55"
Motor
16" X 4"
26"
9-7/8"
40-7/16"
- Junction Box
(Right-hand only as shown)
CAPELLA™ 55 WITH INTEGRAL SKIRT
Opt.
Service
Access
33-1/2"
60"
Motor
14" X 4"
27"
6"
43-1/8"
46-5/8"
55"
26"
32-1/2"
43-7/8"
60"
27"
60"
14" X 4"
25-1/4"
- Junction Box
(Right-hand only as shown)
CAPELLA™ SPACESAVER
33-13/16"
Motor
6"
49"
60"
25-1/4"
Opt.
Service
Access
Service Access
33-13/16"
41-9/16"
CAPELLA 60 w/FRONT LEFT MOTOR/PUMP,
Left Hand
33-1/2"
60"
Motor
60"
14" X 4"
27"
6"
46-5/8"
27"
34-15/16"
43-1/8"
- Junction Box
(Right-hand only as shown)
CAPELLA™ 60 WITH INTEGRAL SKIRT
NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.
Jacuzzi Whirlpool Bath K272000AF 7/06
Service Access
Opt.
Service
Access
47-3/4"
CAPELLA™ 60, Left Hand
34"
60"
19" X 4"
Motor
24"
34"
50-1/4"
GALLERY™ CORNER, Left Hand
16
60"
7-1/2"
24"
13"
ROUGHING-IN REFERENCE (CORNER)
- 2" x 4" Stud
TARA™ WITH INTEGRAL SKIRT
- Junction Box
27-1/4"
35"
44"
60"
60"
46"
27-1/4"
35"
14" x 4"
Motor
(Right-hand only as shown)
ROUGHING-IN
Opt.
Service Access
Service
Access
27-1/4"
35"
44"
60"
Motor
14" x 4"
46"
- 2" x 4" Stud
60"
27-1/4"
35"
27-1/4"
35"
60"
Motor
14" x 4"
46"
- 2" x 4" Stud
60"
27-1/4"
TARA™, Left Hand
TARA™, Right Hand
NOTE: 1. The overall dimensions are nominal with a tolerance of +0 and -1/4" (6,4 mm).
2. Service Access dimensions given are minimum. Service access is still required for units that do not have pre-installed Pump/Motor.
3. Measurements inside each unit represent cutout in floor to allow for drain/overflow.
4. All measurements are in inches. To convert to millimeters, multiply inches by 25.4.
5. Not all export units come with pre-installed Pump/Motor.
CUTOUT
CUTOUT- CORNER BATHS
58"
(1473 mm)
59"
Ref.
Overflow
90˚
25-1/2"
(648 mm)
CAPELLA 60 W/ FRONT LEFT MOTOR/PUMP
(Motor/Pump position not shown.)
58"
(1473 mm)
22-5/8"
m
Overflow
)
GALLERY CORNER,
90˚
(575 m
Drain
45-9/16"
(1157 mm)
CAPELLA 60 &
3" RADIUS CORNERS (5 PLACES)
Drain
50"
(1270 mm)
Right Hand
(1473 mm)
Motor
58"
(1473 mm)
25-1/2"
(648 mm)
58"
22-5/8"
(575 mm)
90˚
90˚
57"
Ref.
Service
35"
44"
57"
Ref.
Opt.
Access
Service Access
(1473 mm)
90˚
22-5/8
(575 mm)
59"
Ref.
90˚
25-1/2"
(648 mm)
58"
Motor
"
GALLERY CORNER,
58"
(1473 mm)
Overflow
TARA CORNER CUTOUT
3" RADIUS CORNERS (5 PLACES)
Drain
50"
(1270 mm)
Left Hand
Drain
45-9/16"
(1157 mm)
Right Hand
Motor
58"
(1473 mm)
Overflow
58"
(1473 mm)
25-1/2"
(648 mm)
90˚
22-5/8"
(575 mm)
90˚
ENGLISH
59" Ref.
90˚
25-1/2"
(648 mm)
58"
(1473 mm)
Motor
TARA CORNER CUTOUT
45-9/16"
(1157 mm)
Left Hand
17
Drain
(1473 mm)
Overflow
58"
25-1/2"
(648 mm)
90˚
Jacuzzi Whirlpool Bath K272000AF 7/06
Framing and Support
INSTALLATION INSTRUCTIONS
The drain/overflow of the bath extends below the bottom of the bath. Note that this requires a cutout in the floor.
The floor structure beneath the bath must be able to support a total weight of bath, water, and bather. Refer to the table under total
weight for your model. The unit must be supported from the bottom of the bath and not from the bath rim or tile flange. If the subfloor is level
and a continuous surface, no other preparation is necessary. You can proceed to install the bath. If the subfloor is not level, you MUST level the entire surface prior to installing the bath. The use of materials that provide a level installation are allowed provided the method used will insure a level bath that is supported from the bottom. Materials that may be used are a floor leveling compound, mortar, plaster or minimal expansion structural foam having a density of a minimum of 5 lbs./cubic ft.; however the bath must remain level in order for it to drain properly and all foam feet must make full contact with the leveling material. Both sides of a joint or splice of subfloor should be level to each other. When attaching
ENGLISH
baths with flanges to stud wall, use shims to fill any gaps between the bath flange and studs.
The rim of the bath is not designed to support weight. If finish material is to overlap or contact the bath, the added weight must be fully self-
supporting.
The protective film liner inside the bath is used to prevent damage to the finish during installation. Before installation, remove
liner to inspect for any defects, reapply and do not remove until final cleanup.
Important: If a skirt is to be used, it must be installed at the time of unit installation – refer to skirt installation instructions. Install
optional trim parts when all installation has been completed.
TYPICAL INSTALLATIONS
MORTAR OR ADHESIVE
FLASHING
TILE
MORTAR OR ADHESIVE
SEALANT
SEALANT
TILE
PLASTER
FILLER
FLANGE
FINISHING MATERIAL
MORTAR
CEMENT BOARD
BATH RIM
NAIL OR SCREW
STUD WALL
SILICONE SEALANT
1" X 4" (NOT FOR SUPPORT)
OPTIONAL TILE FLANGE KIT
1" X 4" (NOT FOR SUPPORT)
FLUSH TO WALL
SUB-FLOOR
FLASHING
1" X 4" (NOT FOR SUPPORT)
SEMI-SUNKEN
NOTE: ON the Riva 5 and Riva 6, the discharge plumbing extends slightly beyond the bath rim. When installing either bath as semi­sunken, lower the pump/motor side in first into the cutout.
TYPICAL FLANGE MOUNTING DETAIL
SHIM IF NECESSARY TO FILL GAPS BETWEEN STUD AND FLANGE
STUD
CAULKING
FLANGE
1/8" GAP
TILE
CEMENT BOARD
TILE ADHESIVE
ATTACH WITH SCREWS PROVIDED
STUD
FLANGE
SHIM IF NECESSARY TO FILL GAPS BETWEEN STUD AND FLANGE
STUD
CAULKING
FLANGE
1/8" GAP
TILE
CEMENT BOARD
TILE ADHESIVE
ATTACH WITH SCREWS PROVIDED
STUD
FLANGE
1"X 4" (NOT FOR SUPPORT)
UNDERMOUNT INSTALLATION OPTIONS
The undermount gives the opportunity to be flexible in the design and location of the bath. Examples are shown for possible installations. Refer to pages 23-24 for undermount installation instructions.
Jacuzzi Whirlpool Bath K272000AF 7/06
FREE STANDINGCORNER NICHE
18
SUPPORT FOR CORNER BATHS
H
2" x 4" STUD
APPLY ADHESIVE
(50,8 mm x 101,6 mm)
T
INSTALLATION INSTRUCTIONS
Skirts
INTEGRAL SKIRT MOUNTING DETAIL
FINISHING
MATERIALS
CAULKING BEAD
SKIRT PANEL
Corner Baths with Skirt
If an optional skirt is used on a corner bath, additional support is necessary in the front of the unit. Measure the height from the floor to the underside of the bath rim. Cut two 2" x 4" studs, apply adhe­sive to both ends and install (See specifications in ROUGHING-IN REFERENCE
(CORNER)).
ENGLISH
U FRAME SKIRT MOUNTING DETAIL
FINISHING MATERIALS
SECURE SHELL CLIP UNDER CENTER BATH RIM
FILLER (Optional)
SKIRT PANEL
SECURE BOTTOM OF FRAME TO FLOOR
CAULKING BEAD
SKIRT FRAME
Removable Skirt Panel
Removal and Installation
To remove panel, grab a top corner of access panel and pull outward to release the first Dual Lock fastener. Then work around the perimeter pulling access panel outward to release the remaining dual Lock fasteners. To reinstall, align access panel such that the Dual Lock fasteners on the access panel match to the Dual Lock fasteners on the tub skirt. Engage each Dual Lock pair until all are snapped into place.
PEEL BACK CORNER
O BEGIN DISCONNECTING
DUAL LOCK™ FASTENER
19
Jacuzzi Whirlpool Bath K272000AF 7/06
MOTOR
AREA
A
AREA
B
FRONT
INSTALLATION INSTRUCTIONS
Service Access
For partially or fully sunken installations, allow for access to ser­vice connections. It is the installer's responsibility to provide suffi­cient service access. The recommended minimum dimensions al­lowable for service to the bath are shown in the "Service Access" illustration and on the ROUGH-IN drawing for that tub.
ENGLISH
Provide adequate area around unit for air circulation for cooling the motor and to supply sufficient air to the jets. Do not insulate this area or around motor.
Optional RapidHeatTM Service Access
Where tubs have been ordered with the optional RapidHeat heater consider an additional service access.
If service access has not been provided, it is the home owners responsibility to remove the bath and provide the required access, should a repair become necessary.
Service Access with Skirt
An optional skirt fits along the side of the bath for above-floor installations and is also an access panel for servicing. Allow a space of at least 8 inches away from the bath for skirt removal.
The skirt is designed to accommodate the added height of the tile, linoleum, or other floor coverings up to 1-1/4" (31,75 mm) above the floor, and will be flush with the floor when installed.
More detailed instructions on skirt installation are provided with the optional skirt assembly.
SERVICE ACCESS
18"
(45,7 cm)
RIGHT HAND UNIT SHOWN
A - Preferred access B - Acceptable alternative if access A is not possible C - Additional access for equipment (Optional)
NOTE: Left hand unit access is on the opposite side (mirror Image).
(CORNER BATHS)
C
36"
(91,4 cm)
A
24"
(60 cm)
B
20"
(50,8 cm)
Service Access with Integral Skirt
SERVICE ACCESS
TM
SERVICE ACCESS
the design of the bath environment and having full understanding that in this case, it may be necessary to remove the unit for service.
without complete access to the plumbing system. This would ne­cessitate the removal of the unit. Although this practice is not com­monly implemented, it is an acceptable method.
Service access is through the removable skirt panels.
(WITH INTEGRAL SKIRT)
REMOVABLE SKIRT ACCESS PANELS
FRONT
ALTERNATE ACCESS
In some cases, access may not have been provided because of
If this is the case, diagnosing a problem may not be possible
ACCESS AREA
(WITHOUT SKIRT)
12"
(30,5 cm)
18"
(45,7 cm)
MOTOR
PREFERRED ACCESS
MOTOR
18"
(45,7 cm)
12"
(30,5 cm)
SERVICE ACCESS
(BG55, CAPELLA 60 FRONT LEFT MOTOR CORNER BATH ONLY)
12"
(30,5 cm)
18"
(45,7 cm)
Preferred access area
Jacuzzi Whirlpool Bath K272000AF 7/06
In some cases access may have been provided in Area A but service is required in Area B which requires the unit to be pulled for service and reinstalled.
If service access has not been provided, it is the homeowner's responsibility to remove the bath and provide the required access, should a repair become necessary.
20
Loading...
+ 44 hidden pages