Do not place or use electrically connected devices, such as television, radio, or stereo speakers, lights, hair
dryers, or telephones, within 1.5 m (5 feet) of shower.
Note: This is a professional grade product. A knowledge of construction techniques, plumbing and electrical
installation according to codes are required for proper installation and user satisfaction. We recommend that
a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath
cover improper installation related problems.
Important: Read complete instructions before beginning installation.
Each unit arrives ready for installation, equipped with base, glass and associated hardware.
Remove the unit from the carton. Retain the shipping carton until satisfactory inspection of the product has been
made.
Immediately upon receipt, inspect the base and other components before installing. Check all carton inserts for
parts and hardware. Should inspection reveal any damage or defect in any component, do not install the unit. Damage
or defect to any component claimed after the unit is installed is excluded from the warranty. Jacuzzi Whirlpool Bath's
responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. Refer any claims
for damage to the carrier. For definitions of warranty coverage and limitations, refer to the published warranty
information packed with the product.
The floor structure beneath the unit must be able to
support a total weight of the unit and bather. Refer
to page 2, SPECIFICATIONS, for weight specifications . Refer to COMPONENT IDENTIFICATION on
page 4 to help identify parts.
STEP 1
Provide an opening in the subfloor no less than 5" x 5"
square. This opening should be located on the center
lines of the shower base drain hole.
C
L
C
L
2" WASTE PIPE
5"X5" OPENING
(MIN. AS POSSIBLE)
INSTALLATION INSTRUCTIONS
STEP 2
Remove the stainless steel strainer from the drain
assembly. Disassemble the locknut and two gaskets
from the back of the drain assembly. Apply a 1/4" bead
of caulking (silicone) to the drain hole and insert the drain
assembly. Replace the rubber washer, fiber washer,
and lock nut in that order. Hand tighten the locknut.
Remove excess sealant from finished side.
Apply a lubricant (common household liquid soap
works well) to the inside of the rubber seal of the drain
assembly.
STRAINER
APPLY LUBRICANT
DRAIN
ASSEMBLY
SHOWER BASE
RUBBER WASHER
FIBER WASHER
SILICONE
SEALANT
NUT
CAUTION: A nonflammable protective barrier must
be placed between soldering work and base unit to
prevent damage to the base.
STUD
WALL
COPPER FITTINGS
AND TUBING
NOT PROVIDED
45° COPPER ELBOW
PROVIDED (2)
DETAIL 1
STEP 3
If the subfloor is level, no other preparation is necessary. You can proceed to install the shower base. If the
subfloor is not level, level the subfloor by spreading floor
leveling compound, mortar, plaster or minimal expansion structural foam with a minimum density of 5 lbs./
cubic feet EVENLY over ENTIRE area where base will
be installed. The compound used MUST make contact
with the entire bottom surface of the base. Both sides
of a joint or splice of subfloor should be level to each
other. Level and support waste pipe cutout area greater
than 5" x 5". The base is NOT to be supported by the tile
flange.
Before installing the base, make sure the 4 water
supply hoses are routed to seat area. If you have a with
Air unit also route the air supply hose to the seat area.
If you have a with Air unit also pull the 2 flow switch
cables and the control panel cable through base at this
time.
With the drain fitting passing over the center of the
drainpipe, lower the shower base carefully into place,
push down firmly until the base is in place.
You must check the level of the base in two directions.
Do not lift a corner of the shower base to level the base.
This will cause a loss of contact with the mortar and void
your warranty. Attach the shower base flange to the stud
wall and blocking with self-drilling screws (included).
Use a minimum of 3 screws per flange section.
FLOW
CONTROL
PANEL
CABLE*
POSITION BASE OVER CENTER OF
DRAIN PIPE AND SET INTO PLACE
* ONLY WITH AIR TOWER UNITS
SWITCH
CABLE*
(2X)
STEP 5
Before installing the seat frame, apply silicone sealant
around mating flange on base. Lower seat frame onto
flange and base. Attach the seat frame flange to the stud
wall and blocking with self-drilling screws (included).
Use a minimum of 3 screws per flange section. Clean up
any excess sealant.
NOTE: If there is any gap between seat frame flange
and stud or blocking, shims MUST be used to prevent distortion or cracking of the flange. See Shim
Instructions.
sponsible for removal and/ or reinstallation costs.
NOTE: If there is any gap between base flange and
stud or blocking, shims MUST be used to prevent
distortion or cracking of the flange. See Shim Instructions.