Inspection and Testing. ................................................................................................................................................. 4
Sub Floor Preparation. .................................................................................................................................................. 4
Preparing the Floor for MZ20000 Drain Alignment Kit. ................................................................................................. 4
After Installing the Finished Floor.................................................................................................................................. 5
OPERATION
General Operating Instructions. .................................................................................................................................... 7
Cleaning - Systems Clean™. ........................................................................................................................................ 7
Before Use. ................................................................................................................................................................. 10
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.
This is a professional grade product. A knowledge of construction techniques, plumbing and electrical installation according to
codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation
of all Jacuzzi Luxury Bath products. Our warranty does not cover improper installation related problems.
English
CAUTION: When using this unit, basic precautions should always be performed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS.
• Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the
manufacturer.
• Never drop or insert any object into any opening.
WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING!
Do not permit children to use this unit unless they are closely supervised at all times. Do not use hydromassage bathtub
unless all suction guards are installed to prevent body and hair entrapment. Never operate the hydromassage bathtub if the
suction cover is broken, damaged or missing.
DANGER: RISK OF SEVERE INJURY FROM ELECTRIC SHOCK OR DEATH FROM ELECTROCUTION!
This unit must be connected only to a supply circuit that is protected by a 15 amp ground fault circuit interrupter (GFCI).
Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test
button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate
in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a
ground current is owing, indicating a possibility of an electric shock. Do not use this hydromassage bathtub. Disconnect the
hydromassage bathtub and have the problem corrected by a qualied service representative before using.
WARNING: RISK OF ELECTRIC SHOCK!
Connect only to a circuit protected by a ground fault circuit interrupter (GFCI). (For permanently connected units) A greencolored terminal (or a wire connector) marked “G,” “GR,” “GROUND,” or “GROUNDING”) is provided within the terminal
compartment. To reduce the risk of electric shock, connect the terminal or connector to the grounding terminal of your
electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying the equipment.
CAUTION: This equipment is intended for indoor use only. Install the equipment in accordance with these instructions. Use
supply wires that are suitable for 167°F (75°C), including the temperature rating of the supply conductors to be used. This
unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber. Building materials and
wiring should be routed away from the motor/pump or blower or other heat producing components of this unit. A pressure
wire connector is provided on the exterior of the motor/pump and heater to permit connection of an No. 8 AWG solid copper
bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to comply
with local requirements.
Important CSA Safety Instructions (Canadian models only)
When using this electrical equipment, basic safety precautions should always be followed, including the
following:
1. WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! CHILDREN SHOULD NOT USE HYDROMASSAGE
BATHTUB WITHOUT ADULT SUPERVISION.
2. WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! DO NOT USE HYDROMASSAGE BATHTUB UNLESS ALL SUCTION GUARDS ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.
3. WARNING: TO AVOID INJURY, EXERCISE CARE WHEN ENTERING OR EXITING THE HYDROMASSAGE
BATHTUB.
4. WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING! DO NOT USE DRUGS OR ALCOHOL BEFORE OR
DURING THE USE OF A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER TO AVOID UNCONSCIOUSNESS AND POSSIBLE DROWNING.
5. WARNING: RISK OF FETAL INJURY! PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A
PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER.
6. WARNING: RISK OF HYPERTHERMIA AND POSSIBLE DROWNING: DO NOT USE A HYDROMASSAGE BATHTUB
EQUIPPED WITH A HEATER IMMEDIATELY FOLLOWING STRENUOUS EXERCISE.
7. SAVE THESE INSTRUCTIONS.
Page 2 www.jacuzzi.comSafety Instructions
Arga™ Bathtubs
Safety Instructions (Continued)
WARNING: RISK OF HYPERTHERMIA AND POSSIBLE DROWNING!
Do not use a hydromassage bathtub equipped with a heater immediately following strenuous exercise.
WARNING: RISK OF ELECTRICAL SHOCK!
• Do not permit electrical appliances (such as a hair dryer, lamp, telephone, radio or television) within 60˝ (1524 mm) of this hydromassage bathtub.
• Do not operate hydromassage system unless the bathtub is lled with water to at least 1-2˝ (25-51 mm)
above the highest air hole.
• Do not immerse the control panel by overlling the bathtub.
• When cleaning your bathtub, do not use abrasive substances which will damage the bathtub’s surface.
• To prevent discoloration of the acrylic nish, do not ll the bathtub with water in excess of 140°F (60°C).
WARNING: PROLONGED IMMERSION IN HOT WATER MAY INDUCE HYPERTHERMIA!
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body
temperature of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body,
dizziness, lethargy, drowsiness and fainting. The effects of hyperthermia include:
A. Failure to perceive heat.
B. Failure to recognize the need to exit the bathtub.
C. Unawareness of impending hazard.
D. Fetal damage in pregnant women.
E. Physical inability to exit the bathtub.
F. Unconsciousness resulting in danger of drowning.
English
WARNING: RISK OF FETAL INJURY!
Pregnant or possibly pregnant women should consult a physician before using a hydromassage bathtub equipped with a
heater.
WARNING: The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia.
People using medications or having an adverse medical history should consult a physician before using a hydromassage
bathtub equipped with a heater.
WARNING: Do not tamper with user-operated controls or such devices.
WARNING: Use this unit only for its intended use as described in this manual. Do not use attachments not
recommended by the manufacturers.
WARNING: To avoid injury, exercise caution when entering or exiting the hydromassage bathtub.
WARNING: Do not use hydromassage bathtub unless all suction guards are installed to prevent body and
hair entrapment. Never operate the hydromassage bathtub if the suction cover is broken, damaged or missing.
WARNING: Water temperature in excess of 104°F (40°C) may be injurious to your health. Check and adjust
water temperature before use.
CAUTION: Test the ground fault circuit interrupter protecting this appliance periodically in accordance with
manufacturer’s instructions.
IMPORTANT: Read the complete instructions provided in this manual before beginning installation.
The Company has obtained applicable code (standards) listings generally available on a national basis for products of this
type. It is the responsibility of the installer/owner to determine specic local code compliance prior to installation of the product.
The Company makes no representation or warranty regarding, and will not be responsible for any code compliance. Product
specications are subject to change without notice.
Safety Instructions www.jacuzzi.com Page 3
Arga™ Bathtubs
Inspection and Testing
Visual Inspection
Remove the bathtub from the shipping carton. Be careful not to scratch the surface of the bathtub on exposed staples.
1
Remove the staples or fold them into the carton. Retain the carton until satisfactory inspection of the product has been made.
Do not lift the bathtub by the plumbing at any time; handle by the shell only.
English
Inspect the shell and bathtub components. Should inspection reveal any damage or defect in the nish or visible damage to
2
any components, do not install the bathtub. Damage or defect to the nish claimed after the bathtub is installed is excluded
from the warranty. Jacuzzi Luxury Bath’s responsibility for shipping damage ceases upon delivery of the products in good
order to the carrier.
Refer any claims for damage to the carrier. For denitions of warranty coverage and limitations, refer to the published
3
warranty information packed with the product.
Bathtub Water and Operational Test
All bathtub units are factory tested for proper operation and watertight connections prior to shipping. However, the unit must be
retested by the installer prior to installation. Jacuzzi Luxury Bath is not responsible for any defect that could have been discovered,
repaired, or avoided by following this inspection and testing procedure:
Remove bathtub from skirt and place on a level surface, near appropriate water supply, and water drainage. A driveway is a
1
suitable choice.
Seal the drain and overow hole with tape or a stopper and ll the bathtub to the bottom of the overow hole.
2
Allow bathtub to stand for 5 minutes. Use operating instructions to ensure tub functions as described. Do not install if tub does
3
not function properly.
Visually inspect all joints for leaks. Do not install the bathtub if leaks are detected.
4
Return bathtub to box or otherwise protect from damage until time of installation.
5
Sub Floor Preparation
Prepare the sub oor for the drain and ensure that the area is level.
The drain/overow of the bathtub extends below the bottom of the bathtub. Identify the drawing in the Technical Specications
1
section that corresponds with your bathtub (available on www.jacuzzi.com).
Determine the location of the basin. The oor must be at and level.
2
Make appropriate cuts to the Sub oor to accommodate the drain.
3
Please refer to the drawing(s) in the Technical Specications section that correspond to your bathtub.
Preparing the Floor for MZ20000 Drain Alignment Kit
Using the supplied template, cut a 5” hole in the sub
1
oor.
Install the drain alignment kit into the sub oor
2
according to the included instructions.
Fig. 1
NOTE: Use included template to plan for placement of drain and electrical connection location for required 15A GFCI
protected outlet.
Page 4 www.jacuzzi.comInstallation Instructions
Arga™ Bathtubs
Installation Instructions
Drain Installation
Install the metal drain/waste tting (supplied with the tub) into the
1
drain hole as illustrated (Fig. 2). Ensure that the drain opening on
the waste tting is situated in the integral overow channel. Use
the brass tting SS99000 & relevant MZ20000 pieces as needed
by model (Fig. 3a/b).
A - For Arga™ Classic: Use SS87000 ABS adapter with poly
2
adapter, brass tailpiece and nut from the drain alignment kit
included in your tub. These will be used for the conversion (Fig.
3a).
B - For Arga™: Use SS99000 brass tailpiece with the threaded
tailpiece from the drain alignment kit and install directly to
SS99000 (Fig. 3b).
A - Cut the brass tailpiece to length. For SS87000 connection,
3
deburr and roll the cut edge with a swage tool. Install
components to the brass tailpiece as shown (Fig. 3a).
B - Cut the brass tailpiece to length. Install components to the
brass tailpiece as shown (Fig. 3b).
Glue the brass tailpiece assembly to the direct drain.
4
English
Fig. 3b
After Installing the Finished Floor
Place bathtub on supports (ex. blocks or 4x4 lumber), ensuring tub feet are fully supported (Fig. 4).
1
CAUTION: Bathtub comes factory pre-leveled, however it may be necessary to make adjustments to the levelling feet. These
feet operate in a manner similar to those of a home appliance. Prior to beginning installation, check to ensure that the tub is
level and make adjustments to the feet as needed.
Fig. 4
Connect the electrical plug to the dedicated GFCI-protected outlet and conrm tailpiece sits properly over drain alignment kit
2
(Fig. 5). Apply silicone to the bottom of tub to attach to oor when lowered in step 3.
Fig. 5
✓
CAUTION: Ensure that the skirt has been fully bolted on before moving further.
Installation Instructions www.jacuzzi.com Page 5
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.