IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING; CHILDREN SHOULD NOT USE HYDROMASSAGE BATHTUB
WITHOUT ADULT SUPERVISION.
WARNING : TO AVOID INJURY, EXERCISE CAUTION WHEN ENTERING OR EXITING THE HYDROMASSAGE BATHTUB
WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING; DO NOT USE HYDROMASSAGE BATHTUB UNLESS ALL
SUCTION GUARDS ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.
WARNING: KEEP BODY AND HAIR A MINIMUM OF 6" AWAY FROM SUCTION FITTING AT ALLTIMES WHEN THE
WHIRLPOOL SYSTEM IS OPERATING. HAIR LONGER THAN SHOULDER LENGTH SHOULD BE SECURED CLOSE TO THE
HEAD.
WARNING:
WARNING: RISK OF ELECTRICAL SHOCK; DO NOT PERMIT ELECTRICAL APPLIANCES (SUCH AS HAIR DRYER, LAMP,
TELEPHONE, RADIO OR TELEVISION) WITHIN 60" (1.5 M) OF THIS HYDROMASSAGE BATHTUB.
WARNING: RISK OF ACCIDENTAL INJURY OR DROWNING; DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING
THE USE OF HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER TO AVOID UNCONSCIOUSNESS AND POSSIBLE
DROWNING.
WARNING: RISK OF FETAL INJURY; PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A PHYSICIAN
BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER.
WARNING: RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; DO NOT USE A HYDROMASSAGE BATHTUB
EQUIPPED WITH A HEATER IMMEDIATELY FOLLOWING STRENUOUS EXERCISE.
CAUTION; TEST THE GROUND FAULT CIRCUIT INTERRUPTER PROTECTING THIS APPLIANCE PERIODICALLY IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
WARNING: RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; WATER TEMPERATURE IN EXCESS OF 100°F (38° C)
MAY BE INJURIOUS TO YOUR HEALTH. CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.
WARNING: RISK OF HYPERTHERMIA; PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE MEDICAL HISTORY
SHOULD CONSULT A PHYSICIAN BEFORE USING A HYRDOMASSAGE BATHTUB EQUIPPED WITH A HEATER.
AN EQUIPMENT GROUNDING TERMINAL IS PROVIDED IN THE FIELD WIRING COMPARTMENT. TO REDUCE THE RISK
OF ELECTRICAL SHOCK, THIS TERMINAL MUST BE CONNECTED TO THE GROUNDING MEANS PROVIDED IN THE
ELECTRICAL SUPPLY PANEL WITH A CONNECTOR EQUIVALENT IN SIZE TO THE CIRCUIT CONNECTORS SUPPLYING
THIS EQUIPMENT.
NEVER DROP OR INSERT ANY OBJECT INTO ANY OPENING.
PRECAUTIONS
Do not operate the whirlpool system unless the bath is filled with water to at least 2" above the highest jet.
Do not use oil-based bath additives in your whirlpool bath.
When cleaning your bath, do not use abrasive substances which will damage the bath's surface.
To prevent discoloration of the acrylic finish, do not fill the bath with water in excess of 140°F (60°C).
The whirlpool system should be purged at least twice a month. For your convenience, we have developed a plumbing system
cleaner (Systems Clean™) specifically for whirlpool baths. For availability call 1-800-288-4002.
Use this unit only for its intended purpose as described in this manual. Do not use attachments not recommended by the
manufacturer.
This unit must be connected only to a supply circuit that is protected by a ground fault circuit interrupter (GFCI). Such a GFCI
should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should
interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, there is a ground
current flowing, indicating a possibility of an electric shock. Do not use this unit. Disconnect the unit and have the problem corrected
by a qualified electrician before using.
A pressure wire connector is provided on the exterior of the motor to permit connection of an No. 8 AWG (8.4 mm) solid copper
bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to comply with
local requirements.
This unit should be installed by a licensed electrician and grounded.
For built-in and drop-in units, install to permit access for servicing.
Note: This is a professional grade product. A knowledge of construction techniques, plumbing
and electrical installation according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool
Bath products. Our warranty does not cover improper installation related problems.

Contents
Specifications & Rough-in Reference _____________________________________________________ 2
Framing and Support _________________________________________________________________ 3
Wall Cutout & CD/Radio Installation ______________________________________________________ 4-5
TV Installation _______________________________________________________________________ 6
Service Access ______________________________________________________________________ 7
Electrical ___________________________________________________________________________ 7
Drain Information and Plumbing _________________________________________________________ 7
Water Supply________________________________________________________________________ 7
Operation __________________________________________________________________________ 8-11
Maintenance ________________________________________________________________________ 12-13
Template ___________________________________________________________________________ 15
Warranty ___________________________________________________________________________ 17-18
Save These Instructions for Future Use.
Owner's Record
Date Purchased ____________________________________________________________
Purchased From ____________________________________________________________
Installed By ________________________________________________________________
Serial Number ___________________________
1

DIMENSIONS
68" (1727 mm) L
68" (1727 mm) W
22" ( 559 mm) H1
27" ( 686 mm) H2
35-7/8" ( 911 mm) H3
Specifications & Rough-in Reference
68"
68"
DRAIN/OVERFLOW DIMENSIONS
19" (483 mm) A
12" (305 mm) B
TOTAL WEIGHT/FLOOR LOADING
1500 lb
(682 kg)/
47 lb/sq. ft.
(229 kg/sq. m)
OPERATING
GALLONAGE
120 U.S. gal
(455 liters)
PRODUCT
WEIGHT
250 lb
(114 kg)
ELECTRICAL
REQUIREMENTS
BATH
115 VAC 60 Hz.
30 Amp
Single Phase
(Must be Class A GFCI Protected)
The unit must be hard wired (permanent) from
this circuit to the control box.
H3
H2
34"
H1
DRAIN/OVERFLOW
CUTOUT
16" X 4"
8-3/8"
TOP VIEW
DRAIN/OVERFLOW
24"
48"
FRONT VIEW
A
B
11-7/8"
34"
SENSOR FOR
REMOTE CONTROL
ELECTRICAL
REQUIREMENTS
RAPIDHEAT™ HEATER
115 VAC 60 Hz.
15 Amp
Single Phase
(Must be Class A GFCI Protected)
The unit must be hard wired (permanent) from
this circuit to the control box.
66"
33"
46-5/8"
CUTOUT
2
66"
33"

Important: Read complete instructions before beginning installation.
Each whirlpool bath arrives ready for installation, completely equipped with motor/pump assembly and plumbing and
fittings necessary for whirlpool operation. An optional drain/overflow kit is available for installation on the bath.
Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been
made. Do not lift the bath by the plumbing at any time; handle by the shell only.
Immediately upon receipt, inspect the shell before installing. Should inspection reveal any damage or defect in the
finish, do not install the bath. Damage or defect to the finish claimed after the bath is installed is excluded from the
warranty . Jacuzzi Whirlpool Bath's responsibility for shipping damage ceases upon delivery of the products in good
order to the carrier. Refer any claims for damage to the carrier . For definitions of warranty coverage and limitations,
refer to the published warranty information packed with the product.
All bath units are factory tested for proper operation and watertight connections prior to shipping. Note: Prior to
installation, the bath must be filled with water and operated to check for leaks that may have resulted from
shipping damage or mishandling. Jacuzzi Whirlpool Bath is not responsible for any defect that could have been
discovered, repaired, or avoided by following this inspection and testing procedure.
Framing and Support
The drain/overflow of the bath extends below the bottom of the bath. Note that this requires a cutout in the floor.
The floor structure beneath the bath must be able to support a total weight of bath, water, and bather. Refer
to the table under total weight for your model. The unit must be supported from the bottom of the bath and not
from the bath rim or tile flange. If the subfloor is level, no other preparation is necessary . You can proceed to install
the bath. If the subfloor is not level, you MUST level the entire surface prior to installing the bath. The use of
materials that shim or provide a level installation are allowed provided the method used will insure a level bath that
is supported from the bottom. Materials that may be used are a floor leveling compound, mortar, plaster or minimal
expansion structural foam having a density of a minimum of 5 lbs./cubic ft; however the bath must remain level in
order for it to drain properly and the foam feet must make full contact with the leveling material. Both sides of a joint
or splice of subfloor should be level to each other.
The rim of the bath is not designed to support weight. If finish material is to overlap (maximum 1” overlap) or contact
the bath, the added weight must be fully self-supporting.
The protective film liner inside the bath should be left there to prevent damage to the finish from shoes, tools, etc.
during installation and should not be removed until final cleanup.
SPEAKER
FINISHED
WALL
1" X 4" (NOT FOR SUPPORT)
Typical Installation
WALL
CUTOUTS
WIRES
FOR MODELS WITH TV:
AUDIO CABLES, FAN,
AND TV POWER CORDS
3

Wall Cutout and CD/Radio Installation
The installation requires a cutout in the wall. The cutout allows room for the speakers, CD/Radio speaker/power &
TV audio cable wires.
NOTE: CD/Radio must be must be located a minimum of 5' away from the interior of the bath. The cable provided
with the unit is designed for this minimum distance. If a longer distance is desired, cut the cable and splice to the power
cord with leads provided with the CD/radio. Do not exceed 20' as the CD/radio audio performance will be reduced and
damage to the unit can occur.
Before final setting of the bath, locate the CD/radio speaker & power harness, TV audio cable and CD/Radio grounding wire (CD/Radio chassis to control box bonding bar) coiled under the bath rim. Run wires through wall cutout to
CD/Radio build out.
38"
9" MIN.
CUTOUT IN
WALL (SAME
SIDE AS
MOUNTED
CD/RADIO)
TV AUDIO
CABLE
CUTOUT
5' MINIMUM
MAY BE LOCATED ON
CD/RADIO -
OPPOSITE WALL
FINISHED
WALL
1x4 (NOT
FOR SUPPORT)
To allow clearance for the CD/Radio, build-out section of
wall 7-1/2" from back of stud as shown. We recommend
using 1/2" plywood. A template is provided for sleeve
mounting hole on page 13. Keep CD/Radio build-out
away from insulating materials.
NOTE: CD/Radio has been mechanically fastened to
the bottom of the TV shelf. Remove before installing
unit.
CABLE TV OUTLET
4" MIN.
BATH
PERIMETER
JUNCTION BOX
(POWER TO
CONTROL BOX)
JUNCTION BOX
(FOR HEATER)
Before mounting, press control panel release button and
detach control panel
FINISHED WALL
7-1/2"
4