Jaclo J-TH34, J-TH12, J-TH34-686, J-TH34-688, J-THVC12 Installation Manual

...
INSTALLATION INSTRUCTIONS
Thermostatic Valves
Part #’s: J-TH34, J-TH12
Part #’s: J-TH34-686, J-TH34-688
Thermostatic Valve with Built in Volume Control
Part #’s: J-THVC12
Diverter Valves
Part #’s: J-20682, J-20686, J-20688
FOLLOW ALL APPLICABLE LOCAL PLUMBING CODES, PUBLIC HEALTH AND SAFETY CODES
J-TH34 / J-TH12 J-THVC12
J-TH34-686 / J-TH34-688
J-20682 / J-20686 / J-20688
j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016 p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133 JACLO.COM
10.18.16
|
PG 1
(1) ROUGH VALVE INSTALLATION (J-TH34 /J-TH12)
1. Position valve assembly so outer edge of nished wall is between min./max. thicknesses marked on rough in shield. See Fig. 1
2. Using appropriate fasteners, mount valve assembly to studs/blocking. See Fig. 1
INSTALLATION EXAMPLE
TO SHOWERHEAD OR OTHER PLUMBING ASSEMBLY
1" THICK FINISHED WALL OUTER EDGE
SAMPLE HOLE IN WALL
4½" Ø Max
VALVE ROUGH-IN SHIELD
10.18.16
|
PG 2
4½" DIA. MAX HOLE IN WALL
OPTIONAL VOLUME CONTROL
TO TUB SPOUT ONLY
Figure 1
Hot
Inlet
Cold Inlet
Extra Outlet requires volume control or plug (not supplied)
j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016 p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133 JACLO.COM
(1) ROUGH VALVE INSTALLATION (J-THVC12)
1. Position valve assembly so outer edge of nished wall is between min./max. thicknesses marked on rough in shield. See Fig. 1
2. Using appropriate fasteners, mount valve assembly to studs/blocking. See Fig. 1
INSTALLATION EXAMPLE
TO SHOWERHEAD OR OTHER PLUMBING ASSEMBLY
1" THICK FINISHED WALL OUTER EDGE
SAMPLE HOLE IN WALL
4½" Ø Max
VALVE ROUGH-IN SHIELD
4½" DIA. MAX HOLE IN WALL
TO TUB SPOUT ONLY
TWIN EL SUPPLIED
Figure 1
j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016 p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133 JACLO.COM
10.18.16
|
PG 3
(1) ROUGH VALVE INSTALLATION (J-20682 / J-20686 / J-20688)
A PORT
ON
5 1/8"
1/2"
2 5/16"
3/8" DIA.
7 7/16"
3 9/16"
A
PORT
16 PT.
SPLINE
1. Position valve assembly per Fig. 1
2. Using appropriate fasteners, mount valve assembly to studs/blocking. See Fig. 1
INSTALLATION EXAMPLE
TO SHOWERHEAD OR OTHER PLUMBING ASSEMBLY
1" THICK FINISHED WALL OUTER EDGE
4-1/4" MAX
DIVERTER
SAMPLE HOLE IN WALL
OPTIONAL VOLUME CONTROL
1" Ø Max
J-20686 / J-20688 / J-20682
3 9/16"
B PORT
A
C PORT
B
3 9/16"
1 11/16"
A PORT
C
INLET
1 11/16"
1/2" NPS
Ø1/4"
2x
3x
10.18.16
|
PG 4
TO TUB SPOUT ONLY
Figure 1
j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016 p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133 JACLO.COM
(1) ROUGH VALVE INSTALLATION (J-TH34-686/J-TH34-688)
1. Position valve assembly so outer edge of nished wall is between min./max. thicknesses marked on rough in shield. See Fig. 1
2. Using appropriate fasteners, mount valve assembly to studs/blocking using mounting holes. See Fig. 1
Diverter and Thermostatic valve are factory sealed, do not separate!
INSTALLATION EXAMPLE
TO SHOWERHEAD OR OTHER PLUMBING ASSEMBLY
1" THICK FINISHED WALL OUTER EDGE
THERM./DIVERTER
SAMPLE HOLE IN WALL
35/16"
4½" DIA. MAX HOLE IN WALL
2" Ø Max
4½" Ø Max
VALVE ROUGH-IN SHIELD
Mounting
holes
2x
OPTIONAL VOLUME CONTROL
Hot
Inlet
TO TUB SPOUT ONLY
Figure 1
j a c l o i n d u s t r i e s | 129 Dermody Street Cranford, NJ 07016 p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133 JACLO.COM
Extra Outlet requires volume control or plug (not supplied)
Cold Inlet
10.18.16
|
PG 5