Standard Features
Uses 139.2 gallons (526.9 liters) of water
per hour with sanitizing hot water rinse
All tanks and hoods constructed from
16 gauge 304 stainless steel with a No.3 nish and heliarced welded
Stainless steel frame, legs and feet
Two tank rackless conveyor shall have
a maximum capacity of 14,964 dishes per hour at a belt speed of 8.6 (2.6 M) feet per minute. At 6.8 feet (2 M) per minute capacity will be 11,832 dishes per hour
Belt width of 29” (737 mm) and a maxi-
mum clearance of 25” (635mm) throughout the machine
Enclosure panels, hood and doors are
stainless steel and double wall insulated to reduce heat dissipation, outside sur­ face temperatures, and noise pollution
Insulated access doors for removal,
cleaning and servicing
V-shape tank(s) design to increase visi-
bility and accessibility for cleaning as well as insure complete tank draining
Heated power rinse zone uses fresh
rinse water a second time to provide pristine results
SHIP PING AD DRESS
6209 North U.S. Hi ghway 25E
Gray , KY 40 734
MAILING ADDR ESS
P.O. Box 106 0
Barbourville , KY 40906
A sequential digital temperature
readout of each tank housed in the door of the electrical control panel. The readouts will constantly display the temperature of the pre-wash, wash, power rinse and nal rinse in 5 second intervals
A ball valve in the drain line of each
tank and interconnected to a common machine drain connection at the load end of the machine
Each tank will be automatically lled
and maintained by a water level oat. Water will be automatically added to the machine when required
Block manifold wash arms are easy to
remove, clean, and replace with non- clogging convex wash arm jets
Large, removable scrap screens
Self draining stainlesssteel pumps,
impellers, and housings are readily accessible and serviceable
Conveyor belt drive operates at two
speeds and is protected by an over- load safety device and an automatic shut-down actuator
Each door is equipped with a door
safety switch to prevent it from running when the door(s) are open.
Tel: 1-888-8 00-5672
Fax: 606-523 -1799
info@jackson msc.com
www.jacksonm sc.com
If a door is opened during operation the switch will immediately shut down the machine
Operator activated start-stop
switches on both the load and unload ends and the control panel
Removable insulated panels to
enclose the unit down to the base frame on both the front and rear of the machine
A single, built-in18” (457mm)
diameter indirect vent connection with a 0.19 hp exhaust fan mounted in a cleanable cross duct on the machine for condensate removal and indirect vent connection
3” minimum wall clearance
Service access from front of
machine
Steam
n.
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
" [1048mm]
1
3'-5
3'-10" [1168mm]
DIRECTION OF OPERATION
4
" [972mm]
1
4
3'-2
3' [914mm]
" [486mm]
1
1'-7
1
15'-5
" [4712mm]
2
14'-6" [4420mm]
13'-6" [4115mm]
1
12'-7
" [3840mm]
4
10'-8" [3250mm]
7'-8" [2335mm]
3
2'-5
" [745mm]
8
3
2'-4
" [719mm]
8
1
5
8
3' [913mm]3' [914mm]
18'-6" [5639mm]
2
6
7
8
3
" [486mm]
1
8
9" [229mm]
1'-7
10" [254mm]
" [724mm]
1
2
2'-4
" [930mm]
5
8
3'-0
" [972mm]
1
4
3'-2
" [1945mm]
1
2
6'-4
Control Cabinet Door Open
" [705mm]
4
3
2'-3
3"[76mm] Minimum
4
3'-6" [1067mm]3' [914mm]3' [914mm]3' [915mm]
Floor Sink or Floor Drain
(Optional to drain at load or
unload end of the machine.)
3
1'-2
" [375mm]
4
7'-6" [2286mm]
9'-2" [2794mm]
Doors In The Open Position
18" [457mm] I.D. Square
6'-1" [1855mm]
Optional - Short Doors In The Open Position
1
A.F.F.
6'-10" [2083mm]
" [226mm]
8
7
8
10" [253mm]
3" [72mm] Deep
6" [152mm]
PREWASH SECTION
1
12'-7
" [3843mm]
4
13'-6" [4115mm]
14'-6" [4420mm]
6
15'-5
7'-8" [2335mm]
10'-8" [3250mm]
Condensate Exhaust Duct Minimum 18" Square (Cross Section 324 Sq. I Provided by HVAC Contractor
Exhaust Requirements
- 1200 CFM
Condensate duct to extended into duct pan.
Condensate duct pan mounted on top of dishmachine electrical section.
Note: The condensate removal system built into the dishmachine consists of a fan that will remove 1200 CFM. A single condensate connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 1200 CFM from the area.
WASH
SECTION
1
" [4712mm]
2
POWER RINSE SECTION
5
CONTROL CABINET
8
9'-6" [2896mm]
6'-10" [2084mm]
" [1644mm]
4
3
5'-4
Top of Condensate Duct Pan
3' [915mm]
" [273mm]
" [343mm]
4
3
" [219mm]
1
6" [152mm]
4
7
5
3
2
8
10
8
1'-1
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
2
Legend 1 - 1-1/2" NPT Machine Drain Connection
(Floor drain - optional to either end) 2 - Electrical Connection - See Table for Amp Draw 3 - 3/4" NPT Incoming Water Connection 4 - 1-1/2" NPT Steam Connection 5 - 3/4" NPT Wash Section Condensate Return 6 - 3/4" NPT Power Rinse Section Condensate Return 7 - 3/4" NPT Booster Heater Condensate Return 8 - Condensate Connection - See Detail
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
" [930mm]
" [972mm]
5
8
1
4
3'-0
3'-2
" [1944mm]
1
2
6'-4
Control Cabinet Door Open
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at loador unload end of the machine.)
" [724mm]
1
2'-4
" [705mm]
4
3
2'-3
1
" [4712mm]
15'-5
2
14'-6" [4420mm]
7
8
9" [229mm]
10" [254mm]
3
4
3'-6" [1067mm] 3' [914mm]
2
3' [914mm]
18'-5
6
7
" [5637mm]
8
" [486mm]
1
8
2
1'-7
3
" [375mm]
1'-2
4
13'-6" [4115mm]
12'-7
3' [915mm]
1
" [3840mm]
4
10'-8" [3250mm]
5
7'-8" [2335mm]
3
2'-5
" [745mm]
8 3
2'-4
" [719mm]
8
3' [913mm]
" [486mm]
1
8
1'-7
" [743mm]
" [972mm]
1
1
4
4
2'-5
3'-2
" [1048mm]
1
4
3'-5
3'-10" [1168mm]
3' [914mm]
1
" [240mm]
9
2
1
3' [914mm]
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at loador unload end of the machine.)
DIRECTION OF OPERATION
6'-10" [2084mm]
" [1644mm]
4
3
5'-4
Top Of Condensate Duct Pan
3' [915mm]
Jackson Rackless Conveyors
Wash, Power Rinse & Final Rinse (18’-6” minimum length)
Steam tank heat electrical requirements with booster
Wash 9.7 9.7 4.9
Rinse 5.6 5.6 2.8
Pre-wash/Drive/Exhaust 1 2.2 12 .3 6.2
Total 27.5 27.6 13.9
" [343mm]
1
2
1'-1
" [273mm]
4
3
5
10
" [219mm]
6" [152mm]
8
8
8
CONTROL CABINET
3
4
7
208V 230V 460 V
2
POWER RINSE SECTION
6
5
10'-8" [3250mm]
" [3843mm]
PREWASH SECTION
7'-8" [2335mm]
6" [152mm]
1
WASH
SECTION
13'-6" [4115mm]
14'-6" [4420mm]
1
15'-5
" [4712mm]
2
12'-7
1 4
Jackson Rackless Conveyors
Wash, Power Rinse & Final Rinse (18’-6” minimum length)
Steam tank heat, booster and blower dryer electrical requirements
208V 230V 460V
Wash 9.7 9.7 4.9
Rinse 5.6 5.6 2.8
Pre-wash/Drive/Exhaust 18.7 1 7.9 6.2
Total 34.0 3 3.2 13.9
" [226mm]
8
7
8
6'-1" [1855mm]
10" [253mm]
9'-6" [2896mm]
9'-2" [2794mm]
7'-6" [2286mm]
Door In The Open Position
Optional - Short Doors In The Open Position
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
Load
A “start/stop” switch is located at the load end of the machine for the operators convenience
Load platform is 12 gauge stainless steel.
Machine Dimensions
Load
Height Depth Length
36” (914.4 mm)
38-1/4” (972 mm)
36” (914.4 mm)
Shipping Dimensions
Load / Unload (Shipped Together)
Height Depth Length
71” (914.4 mm)
Weight: 621 lbs / 282 kg
48” (1219 mm)
60” (1524 mm)
Pre-wash Tank
The pre-wash tank features a stainless steel manifold system with stricture­free jets to optimize pressure for soil removal and to provide easy access for removal and cleaning.
A 3.0 hp, 1725 RPM motor and pump is horizontally mounted. The pump housing is stainless steel and self­draining. A stainless steel strainer with a removable basket is included. The pre-wash tank is a sloped design to ensure complete tank draining and to minimize soil build-up.
Pre-wash Tank
Height Depth Length
73” (1854 MM)
Pre-wash Tank
Height Depth Length
79”
(2007 mm)
Weight: 642 lbs / 291 kg
46” (1168 MM)
48” (1219 mm
36” (914.4 mm)
60” (1524 mm)
Wash Tank Power Rins
The wash tank features a stainless steel manifold system with stricture­free jets to optimize pressure for soil removal and to provide easy access for removal and cleaning.
A 3.0 hp 1725 RPM motor and pump is horizontally mounted. The pump housing is stainless steel and self­draining. A stainless steel strainer pan is included. The wash tank is a sloped design to ensure complete tank draining and to minimize soil build-up.
Wash Tank
Height Depth Length
73” (1854 mm)
Wash Tank
Height Depth Length
79” (2007 mm)
Weight: 642 lbs / 291 kg
46” (1168 mm)
48” (1219 mm
36” (914.4 mm)
60” (1524 mm)
r Rinse Tank Final Rinse
Stainless steel powe stricture free jets mo below the wares are for cleaning.
A 2.0 hp , 1725 RP stainless steel hous are included. Pow sloped design to tank draining and build-up
Power Rins
Height Dept
73” (1854 mm)
Power Rinse
Height Dept
79”
(2007 mm)
Weight: 627 lbs
power rinse arms with
jets mounted above and
es are easily removable
1725 RPM motor with a
housing and impeller Power rinse tank is a
to ensure complete
and to minimize soil
Rinse Tank
Depth Length
46”
46”
(1168 m
1168 mm)
Rinse Tank
Depth Length
48”
48”
(1219
(1219 mm
627 lbs / 284 kg
housing and impeller
Power rinse tank is a
to ensure complete
and to minimize soil
Stainless steel rinse arms with jets mounted above and below the wares are easily removable for cleaning.
The nal rinse water will cascade back to the power rinse, wash and then the pre-wash tanks.
Blower Dryer
A stainless steel tunnel incorporat­ed into the discharge section of the machine. The blower dryer keeps the operating personnel from removing the wares before it reaches the end of the unload section. An industrial fan­type with a squirrel cage driven by a 0.6 hp direct drive motor dries the wares as it exits the machine.
*The Blower Dryer is an option and must be specifed at time of order.
Unload
A “start/stop” switch is located at the unload end of the machine for the operators convenience.
Unload platform is 14 gauge stain­less steel.
The drive wheel shaft is supported by two heavy-duty grease-lubri­cated ball bearings in pillow blocks.
Rinse Tank
46”
Rinse Tank
36” (914.4 mm)
60” (1524 mm)
Final Rinse
Height Depth Length
82” (2083 mm)
46” (1168mm)
36” (914.4 mm)
Final Rinse
Height Depth Length
88” (2235 mm)
Weight: 635 lbs / 288 kg
48” (1219 mm
60” (1524 mm)
Blower Dryer
Height Depth Length
88“ (2235 mm)
38-1/4”
(972 mm)
36 (914.4 mm)
Blower Dryer
Height Depth Length
93” (2362 mm)
Weight: 504 lbs / 229 kg
48” (1219 mm
60” (1524 mm)
Unload
Height Depth Length
36” (914.4 mm)
38-1/4” (972 mm)
42” (1067 mm)
Unload / Load
Shipped with load end
Electric
" [486mm]
1
8
1'-7
3
2'-5
8
2'-4
1
9
" [234mm]
4
" [746mm]
3
" [721mm]
8
15'-5
13'-6" [4115mm]
12'-7" [3836mm]
1
" [4712mm]
2
7
6
" [486mm]
1
8
9" [229mm]
1'-7
" [971mm]
" [743mm]
1
4
1
" [1048mm]
1
3'-5
3'-10" [1168mm]
3" [76mm] Minimum
Floor Sink orFloor Drain
(Optional to drain at load or
unload end of the machine.)
4
4
3'-2
2'-5
DIRECTION OF OPERATION
9'-2" [2794mm]
7'-6" [2286mm]
Doors In The Open Postion
6'-1" [1855mm]
" [226mm]
8
7
8
6" [152mm]
3' [914mm]
Optional - Short Doors In The Open Position
" [706mm]
" [972mm]
1
4
2'-3
4
3' [914mm]
3'-2
" [1644mm]
4
3
5'-4
3' [914mm]
" [1943mm]
1
2
6'-4
Control Cabinet Door Open
9'-6" [2896mm]
6'-10" [2083mm]
Top of Exhaust Fan Housing
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
3
3
1'-2
" [375mm]
4
1
18'-6" [5639mm]
2
3
Power Connections Inside ControlPanel
4
3
2
5
7
5
4
3'-6" [1067mm]3' [915mm]3' [914mm]3' [914mm]3' [914mm]3' [914mm]
3" [76mm] Minimum
Floor Sink orFloor Drain
(Optional to drain at load or
unload end of the machine.)
18" [457mm] I.D. Square
A.F.F.
6'-10" [2083mm]
1
3" [72mm] Deep
1
" [129mm]
5
8
12'-7" [3836mm]
13'-6" [4115mm]
1
15'-5
" [4712mm]
2
Condensate Exhaust Duct Minimum 18" Square (Cross Section 324 Sq. In.) Provided by HVAC Contractor
Exhaust Requirements
- 1200 CFM
TYPICAL
Legend 1 - 1-1/2" NPT Machine Drain Connection
(Floor drain - optional to either end)
2 - *Wash Tank Electrical Connection
Condensate duct to extended into duct pan.
3 - *Rinse Tank Electrical Connection 4 - *Booster Heater Electrical Connection
Condensate duct pan mounted on top of dishmachine electrical section.
5 - *Motor Controls Electrical Connection 6 - 3/4" NPT Incoming Water Connection 7 - Condensate Connection - See Detail
*See Table For Amp Draw
Note: The condensate removal system built into the dishmachine consists of a fan that will remove 1200 CFM. A single condensate connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 1200 CFM from the area.
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
6
" [273mm]
4
3
6" [152mm]
10
" [486mm]
1
8
1'-7
3
" [375mm]
1'-2
4
9" [229mm]
1
" [4712mm]
15'-5
2
13'-6" [4115mm]
6
7
12'-7" [3836mm]
2'-5
2'-4
3
" [746mm]
8
3
" [721mm]
8
" [486mm]
1
8
1'-7
" [706mm]
" [972mm]
1
" [1943mm]
1
2
6'-4
Control Cabinet Door Open or unload end of themachine.)
4
3
4
3' [914mm]
2'-3
3'-2
3" [72mm] Minimum
Floor Sinkor FloorDrain
(Optional to drain at load
6'-10" [2083mm]
" [1644mm]
4
3
5'-4
Top of Exhaust Fan Housing
3' [914mm]
5
4
Power Connections Inside Control Panel
4
5
7
3
2
3
18'-6" [5639mm]
2
1
9
" [234mm]
4
1
3' [914mm]3' [914mm]3' [914mm]3' [914mm]3' [915mm]3'-6" [1067mm]
DIRECTION OF OPERATION
" [743mm]
" [971mm]
1
1
4
4
" [1048mm]
1
2'-5
3" [72mm] Minimum
Floor Sinkor FloorDrain
(Optional todrain atload orunload end of the machine.)
3' [914mm]
4
3'-2
3'-5
3'-10" [1168mm]
9'-2" [2794mm]
7'-6" [2286mm]
Doors In The Open Position
6'-1" [1855mm]
Optional - Short Doors In The Open Position
9'-6" [2896mm]
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
5
" [273mm]
4
3
6" [152mm]
10
6
Jackson Rackless Conveyors
Wash, Power Rinse & Final Rinse (18’-6” minimum length)
Electric equirements with booster
K W 208V 230V 460 V
Wash 24 76.3 69.9 3 5.0
Rinse 26 77.8 70.8 35.4
Motors and Controls 12.2 12.3 6 .2
Booster 27 75.0 67.8 3 3.9
Total 241.3 220.8 1 10.5
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
1
" [129mm]
8
Typical
1
12'-7" [3836mm]
15'-5
13'-6" [4115mm]
1
" [4711mm]
2
6" [152mm]
Jackson Rackless Conveyors
Wash, Power Rinse & Final Rinse (18’-6” minimum length)
Electric requirements with booster and blower dryer
K W 208V 230V 460V
Wash 24 76.3 69.9 36.0
Rinse 26 77.8 70.8 35.4
Blower Dr yer, Motors and Controls 20 43.7 41.4 20.7
Booster 27 75.0 6 7.8 3 3.9
Total 272.8 249.9 126
" [226mm]
7
8
8
JFT Flight Machine
ELECTRICAL
An electromechanical control system for increased reliability mounted in a stainlesssteel control cabinet on the front of the machine. A step-down transformer is included to provide 115 volt, 60 cycles, 1 phase operation for controls including selenoid valves, timers, etc. Wiring is 105C, 600-volt thermoplastic insulated wire and routed through UL approved conduit.
Low watt density tubular heating elements are mounted inside the wash and power rinse tanks and are easily removable from the exterior of the unit. Heaters are protected by a water level oat switch control and a high limit overload.
Tank water temperature is maintained by a fast reacting thermostat which will control the heating element.
STEAM
Stainless steel tubular steam coils mounted inside the wash and power rinse tanks below the optimum water level and protected by a water level oat switch control. An external “Y” strainer and high temperature steam solenoid to regulate the ow of steam through the coil. Tank temperature is controlled and maintained by a fast reacting thermostat that will control the operation of the steam solenoid. A oat and thermostatic steam trap to remove the condensate from the coil are included. Steam coils will require a15-30 PSI owing steam pressure.
BOOSTER HEATERS - ELECTRIC
An internally mounted 27 kW electric booster heater sized to raise incoming 110˚F (43˚C) water supply to 180˚F (82˚C) minimum for sanitizing rinse. The electric booster heater will have the capacity to heat 155 GPH from 110˚F (43˚C) to 180˚F(82˚C) minimum. The tank is designed for a working pressure 150 PSI and hydrostatically tested at 300 PSI. The heater is complete with all plumbing, including NPT pipe and ttings from inlet and outlet. Electric heating elements are metal sheathed controlled by a close tolerance immersion thermostat. The booster is protected with a high temperature limit switch and low water cut-o.
BOOSTER HEATERS - STEAM
An internally mounted steam booster heater sized to raise incoming 110˚F (43˚C) water supply to 180˚F (82˚C) minimum for sanitizing rinse. The steam booster heater will have the capacity to heat 216 GPH from 110˚F (43˚C) to180˚F (82˚C) minimum. The tank is designed for a working pressure 150 PSI and hydrostatically tested at 300 PSI. The heater is complete with all plumbing, including NPT pipe and ttings necessary to meet all installation requirements. The booster is protected with a high temperature limit switch and low water cut-o.
DIMENSION REQUIREMENTS
Wall Clearance (Minimum) 3” (19 mm)
Inside Clearance
OPERATING CAPACITY
Dishes per Hour - Belt Speed 6.8 FPM (2.0 MFM) 11,832
Dishes per Hour - Belt Speed 8.6 FPM (2.6 MFM) 14,964
OPERATING TEMPERATURES
Pre-Wash (Recommended) 140˚F (60˚C)
Wash (Minimum) 152˚F (67˚C)
Rinse (Minimum) 161˚F (72˚C)
Final Rinse 180˚F (82˚C)
MOTORS
Pre-wash Pump Motor 3.0 hp
Wash Pump Motor 3.0 hp
Power Rinse Pump Motor 2.0 hp
Conveyor Drive Motor 1/4 hp
HOW TO SPECIFY:
SHIP PING AD DRESS
6209 North U.S. Hi ghway 25E
Gray , KY 40 734
JFT Flight Machine
MAILING ADDR ESS
P.O. Box 106 0
Barbourville , KY 40906
(635 mmx 762 mm)
25”H x 30”W
STEAM REQUIREMENTS
Steam Flow Pressure (PSIG) 15-30
Consumption @110˚F Incoming Water Temperature 145 lbs/hr
Consumption with blower dryer 245 lbs/hr
WATER REQUIREMENTS
Inlet Tempterature 110˚F (43˚C)
Gallons per Hour 139.2 gal (526.9 L)
Waterline Size IPS (Minimum-inches) 3/4” (19 mm)
Drainline Size IPS (Minimum-Inches) 2” (51 mm)
Flow Pressure (PSI) 15-25
TANK CAPACITY
Pre-wash Tank 36 gal (136 L)
Wash Tank 36 gal (136 L)
Power Rinse Tank 36 gal (136 L)
PUMP CAPACITY
Pre-wash Pump 260 gal (984 L)
Wash Pump 260 gal (984 L)
Power Rinse Pump 230 gal (871 L)
Tel: 1-888-8 00-5672
Fax: 606-523 -1799
info@jackson msc.com
www.jacksonm sc.com
07610-002-85 -11 (10/10)
Loading...