Jackson Dishwasher JFT Specifications

JFT Flight Machine
Models
JFT Flight Machine
Project
Item
Quantity
Approval
Date
Options
Blower dryer
Additional wash section
Additional load module
Additional unload module
25’ (8m) wash down hose - mounted
Electrical connection with circuit breakers
Dual point electrical connection
Low prole doors
Flanged feet
Multiple conveyor peg choice
Drain at load or unload end
JFT Flight Machine
Standard Features
Uses 139.2 gallons (526.9 liters) of water
per hour with sanitizing hot water rinse
All tanks and hoods constructed from
16 gauge 304 stainless steel with a No.3 nish and heliarced welded
Stainless steel frame, legs and feet
Two tank rackless conveyor shall have
a maximum capacity of 14,964 dishes per hour at a belt speed of 8.6 (2.6 M) feet per minute. At 6.8 feet (2 M) per minute capacity will be 11,832 dishes per hour
Belt width of 29” (737 mm) and a maxi-
mum clearance of 25” (635mm) throughout the machine
Enclosure panels, hood and doors are
stainless steel and double wall insulated to reduce heat dissipation, outside sur­ face temperatures, and noise pollution
Insulated access doors for removal,
cleaning and servicing
V-shape tank(s) design to increase visi-
bility and accessibility for cleaning as well as insure complete tank draining
Heated power rinse zone uses fresh
rinse water a second time to provide pristine results
SHIP PING AD DRESS
6209 North U.S. Hi ghway 25E
Gray , KY 40 734
MAILING ADDR ESS
P.O. Box 106 0
Barbourville , KY 40906
A sequential digital temperature
readout of each tank housed in the door of the electrical control panel. The readouts will constantly display the temperature of the pre-wash, wash, power rinse and nal rinse in 5 second intervals
A ball valve in the drain line of each
tank and interconnected to a common machine drain connection at the load end of the machine
Each tank will be automatically lled
and maintained by a water level oat. Water will be automatically added to the machine when required
Block manifold wash arms are easy to
remove, clean, and replace with non- clogging convex wash arm jets
Large, removable scrap screens
Self draining stainlesssteel pumps,
impellers, and housings are readily accessible and serviceable
Conveyor belt drive operates at two
speeds and is protected by an over- load safety device and an automatic shut-down actuator
Each door is equipped with a door
safety switch to prevent it from running when the door(s) are open.
Tel: 1-888-8 00-5672
Fax: 606-523 -1799
info@jackson msc.com
www.jacksonm sc.com
If a door is opened during operation the switch will immediately shut down the machine
Operator activated start-stop
switches on both the load and unload ends and the control panel
Removable insulated panels to
enclose the unit down to the base frame on both the front and rear of the machine
A single, built-in18” (457mm)
diameter indirect vent connection with a 0.19 hp exhaust fan mounted in a cleanable cross duct on the machine for condensate removal and indirect vent connection
3” minimum wall clearance
Service access from front of
machine
Steam
n.
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at load or unload end of the machine.)
" [1048mm]
1
3'-5
3'-10" [1168mm]
DIRECTION OF OPERATION
4
" [972mm]
1
4
3'-2
3' [914mm]
" [486mm]
1
1'-7
1
15'-5
" [4712mm]
2
14'-6" [4420mm]
13'-6" [4115mm]
1
12'-7
" [3840mm]
4
10'-8" [3250mm]
7'-8" [2335mm]
3
2'-5
" [745mm]
8
3
2'-4
" [719mm]
8
1
5
8
3' [913mm]3' [914mm]
18'-6" [5639mm]
2
6
7
8
3
" [486mm]
1
8
9" [229mm]
1'-7
10" [254mm]
" [724mm]
1
2
2'-4
" [930mm]
5
8
3'-0
" [972mm]
1
4
3'-2
" [1945mm]
1
2
6'-4
Control Cabinet Door Open
" [705mm]
4
3
2'-3
3"[76mm] Minimum
4
3'-6" [1067mm]3' [914mm]3' [914mm]3' [915mm]
Floor Sink or Floor Drain
(Optional to drain at load or
unload end of the machine.)
3
1'-2
" [375mm]
4
7'-6" [2286mm]
9'-2" [2794mm]
Doors In The Open Position
18" [457mm] I.D. Square
6'-1" [1855mm]
Optional - Short Doors In The Open Position
1
A.F.F.
6'-10" [2083mm]
" [226mm]
8
7
8
10" [253mm]
3" [72mm] Deep
6" [152mm]
PREWASH SECTION
1
12'-7
" [3843mm]
4
13'-6" [4115mm]
14'-6" [4420mm]
6
15'-5
7'-8" [2335mm]
10'-8" [3250mm]
Condensate Exhaust Duct Minimum 18" Square (Cross Section 324 Sq. I Provided by HVAC Contractor
Exhaust Requirements
- 1200 CFM
Condensate duct to extended into duct pan.
Condensate duct pan mounted on top of dishmachine electrical section.
Note: The condensate removal system built into the dishmachine consists of a fan that will remove 1200 CFM. A single condensate connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 1200 CFM from the area.
WASH
SECTION
1
" [4712mm]
2
POWER RINSE SECTION
5
CONTROL CABINET
8
9'-6" [2896mm]
6'-10" [2084mm]
" [1644mm]
4
3
5'-4
Top of Condensate Duct Pan
3' [915mm]
" [273mm]
" [343mm]
4
3
" [219mm]
1
6" [152mm]
4
7
5
3
2
8
10
8
1'-1
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]
2
Legend 1 - 1-1/2" NPT Machine Drain Connection
(Floor drain - optional to either end) 2 - Electrical Connection - See Table for Amp Draw 3 - 3/4" NPT Incoming Water Connection 4 - 1-1/2" NPT Steam Connection 5 - 3/4" NPT Wash Section Condensate Return 6 - 3/4" NPT Power Rinse Section Condensate Return 7 - 3/4" NPT Booster Heater Condensate Return 8 - Condensate Connection - See Detail
Visit us at www.jacksonmsc.com or call us at 1-888-800-5672
" [930mm]
" [972mm]
5
8
1
4
3'-0
3'-2
" [1944mm]
1
2
6'-4
Control Cabinet Door Open
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at loador unload end of the machine.)
" [724mm]
1
2'-4
" [705mm]
4
3
2'-3
1
" [4712mm]
15'-5
2
14'-6" [4420mm]
7
8
9" [229mm]
10" [254mm]
3
4
3'-6" [1067mm] 3' [914mm]
2
3' [914mm]
18'-5
6
7
" [5637mm]
8
" [486mm]
1
8
2
1'-7
3
" [375mm]
1'-2
4
13'-6" [4115mm]
12'-7
3' [915mm]
1
" [3840mm]
4
10'-8" [3250mm]
5
7'-8" [2335mm]
3
2'-5
" [745mm]
8 3
2'-4
" [719mm]
8
3' [913mm]
" [486mm]
1
8
1'-7
" [743mm]
" [972mm]
1
1
4
4
2'-5
3'-2
" [1048mm]
1
4
3'-5
3'-10" [1168mm]
3' [914mm]
1
" [240mm]
9
2
1
3' [914mm]
3" [72mm] Minimum Floor Sink or Floor Drain (Optional to drain at loador unload end of the machine.)
DIRECTION OF OPERATION
6'-10" [2084mm]
" [1644mm]
4
3
5'-4
Top Of Condensate Duct Pan
3' [915mm]
Jackson Rackless Conveyors
Wash, Power Rinse & Final Rinse (18’-6” minimum length)
Steam tank heat electrical requirements with booster
Wash 9.7 9.7 4.9
Rinse 5.6 5.6 2.8
Pre-wash/Drive/Exhaust 1 2.2 12 .3 6.2
Total 27.5 27.6 13.9
" [343mm]
1
2
1'-1
" [273mm]
4
3
5
10
" [219mm]
6" [152mm]
8
8
8
CONTROL CABINET
3
4
7
208V 230V 460 V
2
POWER RINSE SECTION
6
5
10'-8" [3250mm]
" [3843mm]
PREWASH SECTION
7'-8" [2335mm]
6" [152mm]
1
WASH
SECTION
13'-6" [4115mm]
14'-6" [4420mm]
1
15'-5
" [4712mm]
2
12'-7
1 4
Jackson Rackless Conveyors
Wash, Power Rinse & Final Rinse (18’-6” minimum length)
Steam tank heat, booster and blower dryer electrical requirements
208V 230V 460V
Wash 9.7 9.7 4.9
Rinse 5.6 5.6 2.8
Pre-wash/Drive/Exhaust 18.7 1 7.9 6.2
Total 34.0 3 3.2 13.9
" [226mm]
8
7
8
6'-1" [1855mm]
10" [253mm]
9'-6" [2896mm]
9'-2" [2794mm]
7'-6" [2286mm]
Door In The Open Position
Optional - Short Doors In The Open Position
Maximum Ceiling Height for Short Doors - 7'-10" [2388mm]