Jablotron RC80 User Manual

RC-80 wireless keyfob
The RC-80 is a component of Jablotron’s Oasis 80 alarm system. It is designed to remotely control setting/unsetting, trigger panic alarms, and control other appliances. The battery-powered keyfob communicates via OASIS radio protocol.
The keyfob has two buttons as supplied, but changing its cover (held by a screw on the back) makes four buttons possible:
Enrolling the keyfob to an Oasis control panel
A pair of the keyfob buttons can be enrolled to a control panel by pressing and holding both buttons. Proceed as follows:
1. Put the control panel into Service mode via the system keypad and press
2. Press and hold and or and (the pair of buttons you wish to
3. Exit enrollment mode by pressing the # key on the keypad controlling the
The natural reaction of the pair of buttons is setting and unsetting for each
If you enroll two pairs of buttons on a single keyfob to two different
If a single pair of buttons is enrolled to the control panel, the two remaining
Testing the keyfob
The strength and quality of keyfob radio signals can be checked and measured by the
control panel in Service mode.
Locking the keyfob
If all four buttons on the keyfob are used, all keys can be locked or unlocked by pressing a diagonal button pair ( + or + ). When the keys are locked, the
keyfob LED flashes rapidly if any button is pressed (no signals are sent under these conditions).
Using the keyfob with other products
In addition to Oasis control panels, the keyfob can also be used with other
Jablotron products that communicate via Oasis protocol. Examples are relay receivers type UC-8x and AC-8x. Guidance on using the keyfobs can be found in the manuals of the desired receiver.
Battery replacement
If the working range of the keyfob begins to reduce, or if functioning stops
altogether, then replace the battery. The keyfob can be easily opened by
unscrewing the rear screw.
Expired batteries should not be thrown into the garbage, but disposed of according
to local regulations.
Removing the keyfob from the system
If you wish to remove the keyfob from the system, e.g. if it has been lost, erase
it from its address in the control panel.
Voltage: alkaline battery type L1016 (6.0 V) Typical battery lifetime approx. 3 years (5 daily activations) Communication band: 868 MHz, Oasis protocol Communication range approx. 30 metres (open area) Operational environment according to EN 50131-1 II. indoor general Operational temperature range -10 to +40 °C Can be operated according to ERC REC 70-03, FCC Part 15 Complies with ETSI EN 300220, EN 55022, EN 50134-2 EN 50130-4,EN 60950-1, ANSI C63.4
FCC ID VL6RC80
key 1 to enter enrollment mode. Using the arrow keys, select the desired address.
enroll) simultaneously until three flashes on the keyfob LED are seen. control panel.
button respectively, and panic alarm triggering by pressing both buttons together. If a reaction other than natural is assigned to the keyfob’s address in the control panel, the reaction will only be triggered by buttons
or (according to which pair was enrolled).
addresses in the control panel, then different reactions and sections can be assigned to each pair of buttons. This means, for example, one pair could set/unset the complete system, and the other pair could be used for partial setting.
The button pair and can also be enrolled by simply installing a battery into the keyfob.
buttons can be used to control another device such as e.g. a Jablotron car alarm, or UC-8x and AC-8x receivers.
Technical parameters
Jablotron Ltd. hereby declares that the RC-80 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC and complies with part 15 of the FCC rules. Operation is subject the the following two conditions: 1. This device may not cause harmful interference,
and 2. this device must accept any interference received, including interference that may cause undesired operation.
The original of the conformity assessment can be found at
www.jablotron.com, Technical Support section CAUTION: Changes or
modifications no expressly approved by Jablotron could void the user´s authority to operate the equipment
Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use.
JA-80P wireless PIR motion detector 1 MHP51800FCC