jablotron JA-89P Quick Start Manual

Page 1
The JA-89P wireless outdoor PIR detector
Rear tamper
LED
L
I
T
H
I
U
M
3
.
6
V
A
A
The JA-89P wireless outdoor intruder detector is designed to detect human body movement in a protected area. It supplements a double-zone PIR sensor produced by Optex with a Jablotron transmitter enabling the detector to be used within the JA-8x OASiS 100 system. The optical part of the detector has 2 PIR sensors and a high immunity to false alarms and the detection of small animals. The detector includes an anti-masking function – protection against covering the view and it also has two tampers (front and back) built in. They immediately report opening the detector or attempting tampering. The detector does a self-test periodically and sends its status to the control panel. The detector should be installed by a trained technician with a valid certificate issued by an authorised distributor.
1. The detector has to be installed onto a vertical wall (in a position where
its bottom surface is parallel to the watched zone).
2. The detector should be installed 0.8 – 1.2 m above the ground.
3. The best movement detection is provided when the detection beams
intersect.
4. No other moving objects (bushes, trees, high grass, air-conditioners, etc.)
should be situated in the field of view of the detector. Avoid direct action by strong sources of light (sun reflections, etc.).
Note: If multiple JA-89P detectors are used, they mustn´t be installed face to face with each other and it’s recommended to install them with a minimum 1 m distance.
Installation
Enrolling the detector to the system
The signal transmitter for wireless communication is located under the main board part of the detector. Read the manual of the receiving unit (control panel) before you insert a battery into the transmitter. The batteries are inserted into the battery holder of the OPTEX motion detector. Always use a AA 3.6 V lithium battery. The correct position of the battery is indicated on the battery holder.
Enrollment procedure to the system:
a. Read the installation manual of the receiving unit before you insert the
batteries into the detector. There must be a radio module installed in the
control panel. b. Open the enrollment mode on the receiving unit. c. Insert the batteries (mind the correct polarity). When the battery has
been inserted into the battery holder an enrollment signal is transmitted
to the control panel and the detector is enrolled to the selected position. d. By DIP switch no.2 set the reaction to detected movement (ON =
Instant, 2 = delay). Leave DIP switch no.1 in position 1 (pulse mode). e. Assemble the detector.
Switch No. 1
PULSE*
STATE
Switch No. 2
DELAYED
INSTANT
Set to
*
pulse mode
Vcc
TMP
INP
GND
connection
Procedure:
1. Unscrew the locking screw placed on bottom of the upper cover of the detector (1) and remove the detection part cover (1).
2. Unscrew the 2 screws which hold the detector´s main board (2) and pull it out by tilting as you pull it out.
3. Remove the battery holder.
4. Remove the rear box cap (5).
5. Unscrew the 2 screws which link the rear cover (3) to the mounting plate (4).
6. The detector can be mounted onto a level mounting place by the 2 screws through the mounting plate (4). Or it can be mounted on a pole by ties.
7. Put the detector’s parts back together in the opposite order when it´s finally fixed to the mounting place (4).
Warning: Do not touch the detector sensing face during handling.
5
3
2
1
Fig. 1.: 1 – front cover, 2 – detector main board, 3 – rear cover,
Fig. 2.: Detector installation. Standard wall installation and fixing by ties.
4 – mounting plate, 5 – rear cover cap
4
detector
connection
Fig. 3 – The JA-89P detector transmitter
Setting up the optical part of the detector
The optical part of the detector includes 2 PIR sensors with AND logic. They detect movement in two planes. The detecting angle of the lower PIR sensor can be adjusted. The alarm signal is triggered if only both detecting planes are triggered at the same time. By shifting the lens set up the tilt of the lower detecting plane according to the following picture and table.
Fig. 4.
The following table represents the values included in the figure:
Maximum range of the lower detecting
Position
part
Average value see following limits:
1 12 m 10 to 17 m 2 8.5 m 7 to 12 m 3 6 m 5 to 8.5 m 4 3.5 m 3 to 6 m 5 2.5 m 2 to 3.5 m
Table 1.
Warning: The maximum detection length of the lower detection plane may vary as above due to environmental thermal conditions. This must be taken into consideration during detection range adjustment.
The JA-89P wireless outdoor PIR detector 1 / 2 MKU51105
Page 2
The JA-89P wireless outdoor PIR detector
Fig. 5.
The detection area angle is 90°. The direction can be adjusted from position A – G by rotating the detector´s plastic part. Each step is marked. The detector lens covers a whole angle of 180° - therefore it does not require any adjustment.
You can restrict the detection angle by adhesive masking strips supplied with the package. This way you can eliminate problematic parts of the detection area. The strips are to be stuck on the relevant lens segment on the inside.
The PIR detection sensitivity can be configured by a 3-pole switch located under the upper sensor. The letters correspond to sensitivity levels as follows:
L low – applicable to bad conditions M medium H high
Other parameters can be configured using a DIP switch:
NORM
120s N.C. LED OFF
Antimasking OFF
Factory settings highlighted by bold letters.
TEST
5s 5 s … šetřící režim N.O. LED ON on
Antimasking ON
The LED serves for PIR detector testing – checking the coverage. The detector always sends information to the control panel. For normal detector operation the LED should be turned off in order to save the battery.
The power save mode can be set up by DIP switch no. 2.
By DIP switch no. 1, enter test mode and by DIP switch no. 4 turn on the
Testing (coverage test)
LED indication. Close the detector. Test the detection range of the protected area and immunity outside the protected area.
Bear in mind the potential changing of detecting distance influenced by the environment.
Each movement is indicated by LED and it sends the information to the control panel.
We recommend turning off the indication LED when the testing procedure is finished. And set up the power save mode to 120s to get a longer battery lifetime.
Normal operating mode
The detector sends a radio signal about activation when it is triggered. In the case of tampering with the detector or tearing the detector off its position the detector sends a tamper signal. Every 9 minutes a status report is sent to the control panel to test that all its devices are present and ready for operation.
Replacing the batteries
The detector checks its battery status automatically and if the batteries are running low it informs the system. The detector remains fully functional. The batteries should be changed as soon as possible (within 1 week).
Before battery replacement the control panel has to be switched to service mode (see installation manual of the control panel) and then it is possible to open the cover of the detector. Always use 3.6 V AA lithium batteries.
Note: If you insert a nearly drained battery into the detector by mistake, the detector does not start working and this status is indicated with the transmitter LED flashing. If the battery is completely drained, the detector does not react at all.
Caution: Expired batteries should not be thrown into the garbage, but disposed of according to local regulations.
Troubleshooting
Problem Problem cause Solution
The detector makes false intrusion alarms
Occasionally no reaction to movement
Detector ignores any movements
Fig. 6. Detector dimensions (mm)
Lower detection area is unnecessarily long. The detector is exposed to direct/reflected light (sun light, car light etc.).
Set the detection area properly. Remove the reflector, mask the area exposed to the reflection of light or change
the detector position. There is a moving object in the area (laundry on the clothes-line, plants etc.).
Remove the moving object or
change the detector position.
Or put the stickers on part of
the lens to avoid detection in
a problematical place. Lower detection area is unnecessarily short Sensitivity is set to low (L). The detector is in battery­save mode
Set the detection area
properly
Change sensitivity to medium
(M) or high (H).
While testing operation, set
the battery-save timer to 5
seconds. Low battery Replace the battery LED indicator lights but there is no reaction in the control panel.
The control panel is out of
range, check the battery, try
to reposition detector or
control panel
Technical specifications
Power Lithium battery type CR14500 (AA) 3,6 V / 2,45 Ah Average battery lifetime approx. 3 years
(valid for enabled 120s saving mode)
Please note: Batteries are not included
Communication band 868.5 MHz RF range – communication range up to 300 m (open area)
Optex detector parameters Detection characteristics 12 m / 90°; 16 segments Recommended installation height 0.8 – 1.2 m Object motion speed 0.3 – 1.5 ms-1 Battery saving timer adjustable 5 s or 120 s LED indication during a coverage test Operational environment according to EN 50131-1 IV Security grade according to Optex Operating temperature range -20 °C to +60 °C Detector cover conformance IP55 Max. relative humidity of the environment 95 % Dimensions 186 x 71.3 x 105.5 mm Weight 500 g Complies with ETSI EN 300 220-1, EN 50130-4, EN 55022, EN 60950-1, EN 50581 Can be operated according to ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-89P is in a compliance with the relevant Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the conformity assessment can be found at www.jablotron.com - Section Downloads.
Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use.
The JA-89P wireless outdoor PIR detector 2 / 2 MKU51105
Loading...