jablotron JA60K, JA60X Installation Manual

Page 1
Alarm system JA-60 “COMFORT” - 1 - MDY51306
JA-60 Alarm system
Installation manual
JA60K/JA60X
quick hom e
door
code
mem
Page 2
Alarm system JA-60 “COMFORT” - 2 - MDY51306
Contents:
1. Before starting 4
2. Control panel installation 4
2.1. Opening of control panel 4
2.2. Attaching the control panel to the wall 4
2.3. Antenna installation 4
2.4. Connection of the AC adapter 4
2.5 Connection of the telephone line (only for model with optional built in dialer) 5
2.6. Back up battery installation 5
2.7. Powering of the control panel 5
3. Installation of detectors 5
3.1. JA60M - magnetic door detector installation 5
3.2. JA60P - motion detector installation 6
4. Enrollment of detectors and remote controls 7
4.1. Procedure for enrolling detectors and controllers 7
4.2. Enrollment or deletion of a detector or controller to/from a desired position (zone) 7
4.3. Enrollment of detectors for partial (HOME) arming 8
5. Testing of detectors and controllers 8
5.1. JA60M - magnetic door detector testing 8
5.2. JA60P - motion detector testing 8
5.3. Remote control and wireless keypad testing 9
5.4. Recording detector’s location 9
6. Finishing of the installation 9
7. Setting of the system 9
7.1. List of control panel programmable parameters 10
7.2. Control panel programming 11
7.2.1. Testing of the system 11
7.2.2. Enrollment (teaching) of wireless items 11
7.2.3. Exit / Entrance delay 12
7.2.4. Alarm duration 12
7.2.5. PgX and PgY output functions 12
7.2.6. Message and numbers: editing in the user mode 12
7.2.7. Radio signal jamming testing 12
7.2.8. Regular communication checking 13
7.2.9. Reset Enabled 13
7.2.10 Enrollment of the control panel to a UC216, 222, JA-60K etc. 13
7.2.11. No code requested for F1, F2, F3, F4 & F9 13
7.2.12. Partial (Home) arming with F2 14
7.2.13. Built in siren alarm 14
7.2.14. Exit delay audible indication 14
7.2.15. Partial arming exit delay audible indication 14
7.2.16. Entrance delay audible indication 14
7.2.17. Arming and disarming chirp sounds 14
7.2.18. Built in siren alarm in Disarm & Partial arming 15
7.2.19. Wireless siren alarm 15
7.2.20. Indication of system problems when arming 15
7.2.21. Real time and date setting 15
7.2.22. New service code setting 16
7.2.23. Telephone numbers: entering 16
7.2.24. Voice message recording 16
7.2.25. Telephone dialer testing 16
7.2.26. Dialing method 16
7.2.27. Telephone dialer triggering 16
7.2.28. Telephone line checking 17
7.3. Factory default RESET 17
8. Possibilities to extend the system 18
8.1 Overview of JA-60 parts 18
8.1.1. Detectors 18
8.1.2. Controllers 19
8.1.3. Output devices 19
8.1.4. Telephone dialer module JA60X 19
8.1.5. PC interface cable PC60A 19
8.1.6. Control panel as a subsystem 19
8.2. Connection of other items to the system 19
8.2.1. Use of external sensors with JA60M 20
8.3. Terminals in the control panel 20
9. Trouble shooting table 21
10. Recommended Professional installer basic rules 22
11. Specifications 22
12. Annex A (manuals of system items) 22
Page 3
Alarm system JA-60 “COMFORT” - 3 - MDY51306
Thank you for purchasing this alarm system. Its r eliable operation depends on proper installation. W e recom mend hav­ing this alarm professionally installed. To find a qualified installer, please contac t your Distributor. The manufacturer has no liability for consequences caused by incorrect installation or improper use of this system.
1. Before starting
First select suitable locations for all sensors and accessories. The location of these sensors should take into consideration the building’s safety and basic rules for good radio communication. The working range of the wireless accessories from the control panel is about 100 meters in optimal conditions. However, building materials can absorb or obstruct radio signals , and communication can also be effected by interference from other radio signals. For these reasons , you should anticipate a shorter working range for indoor installations. The control panel checks the radio signals during the installation and if the quality of comm unication with any accessory is not sufficient, this item will not be enrolled into the system. No part of the system, except the outdoor siren, JA-60A, is suitable for outdoor use.
You can connect your PC to the JA-60 control panel, using the PC60A connect­ing cable and the ComLink sof tware. This option is convenient for easy program ­ming, diagnostics and storing data about the installation.
2. Control panel installation
The control panel should be easily accessible, but not very visible. There should be a power socket available and also a telephone line (if the system has an optional built in dialer).
2.1. Opening of control panel
Fig. 1
Press in the bottom tab via the small slot using a narrow flat screwdriver.
Remove the cover and gently pull the cable to disconnect it from the board.
2.2. Attaching the control panel to the wall
The surface of the wall should be level. Avoid plac ing the panel in locations that will result in the antenna being near any large metal objects.
There are two slots for screws on the back side of the rear panel.
Drill a hole and insert one of the provided plastic dowels for the top screw.
Partially tighten the screw, leaving part of its head sticking out.
Place the rear housing over the screw and slide it down so that the screw is
in the middle of the slot.
Now mark position of the lower screw through the housing hole and remove
the housing. Drill the second hole and insert a second plastic dowel.
Replace the housing on the top screw once again.
Do not tighten the lower screw until after the control panel cables are routed
(AC adapter, tel. line, additional siren etc. – see description bellow).
Fig.2
2.3. Antenna installation
••••
Attach the rubber antenna into the threaded hole on the right hand side on
the top of the rear housing.
2.4. Connection of the AC adapter
Route the adapter’s output cable to the control panel and connect it to the
panels power jack (see fig. 3.).
Do not plug the AC adapter into the wall
yet.
Fig. 3
Page 4
Alarm system JA-60 “COMFORT” - 4 - MDY51306
2.5 Connection of the telephone line
( for model with an optional built in dialer only)
Use the provided telephone cable to connect the telephone line to the IN jack
inside the control panel (see fig. 4),
Connect any telephone, fax or other phone operated device to the OUT jack,
marked with a phone symbol
When the control panel is in normal stand by mode, the phone line and any
attached device will operate as normal.
2.6. Back up battery installation
WARNING – Do not make any short connection of the battery ter minals under any circumstance!
Remove the covering folio from the adhesive tape inside the battery com-
partment (see fig. 5),
Slide the black wire connector that is inside the battery compartment over the
black terminal of the battery (minus),
Place the batter y into the battery compartment so that the Black term inal is
inside, and the battery is fixed to the adhesive tape.
Do not yet connect the red wire to the Red terminal
fig.
4
Note:
The control panel normally charges the battery. The battery can provide over 12 hours of power to the control panel if there is a failure of the AC power. Before the battery is dis­charged completely, the control panel will trigger a technical alarm and the battery will be electronically disconnected to avoid any damage. When the AC power is reconnected, the battery will automatically recharge.
2.7. Powering of the control panel
Straighten and smooth the cables under the control panel and tighten the
control panel’s lower screw. (Be sure that the panel is not crooked.)
Connect the Red wire connec tor over the Red terminal of the battery (posi-
tive)
Reconnect the c able from the front panel to the main board inside the rear
housing.
Reattach the front panel by placing the top side of the front panel over the top
of the back panel and then push the bottom side against the wall (the tab will click).
Plug in the AC adapter to the wall socket.
The control panel’s LED display will display „P“, confirming that the system is
in programming m ode (for system setting, enrollment of detectors and test­ing).
Note
: if „P“ is not displayed at this moment, the c ontrol panel is not currently in f actory defaul t set-
ting. Perform Factory default reset. (See section 7.3. ).
fig.5 fig.6
3. Installation of detectors
Do not attach detectors near larger m etal objects ( this could obstruct radio c omm unication). W hen choosing the loc ation of the detectors, keep in cons ideration that a detector’s batteries have to be replaced f rom time to tim e (approximately once a year). There is a description of the bas ic installation of the JA- 60M ( m agnetic door detector), and the JA60P (m o­tion detector), below. If you also install other items (sm oke detector, gas detector, remote k eypad, wireless siren etc.), see section 12 or manuals provided with the each particular item.
3.1. JA60M - magnetic door detector installation
T he JA60M detects the opening and closing of a door or a window. It also has inputs for external sensors (see section
8.2.1.). Each detector is equipped with a magnet (movement of the magnet triggers an internal sensor in the detector). We recommend to locate the detector unit on the wall or the frame of the door or window, with the magnet on the moving part of the door or window.
Page 5
Alarm system JA-60 “COMFORT” - 5 - MDY51306
Open the detector’s cover by pressing the internal tab – see fig. 7
Attach the detector to the desired location using the two provided screws.
Be sure that the antenna is vertical (pointing up or down)
Attach the magnet with the provided scr ews to the moving part of the door or
window, and attach its cover. The gap between the detector and magnet should not be wider than 5mm when the door is closed (see fig. 8)
Warning
: neither the detector nor the magnet should be f ixed directly to a m etal surface. If there is no other choice, an insulating pad (plastic, wood etc.) 5m m thick or more should be used under the detector and the magnet.
fig.
7
Fig.
8
Use DIP switch no. 1 to select if the r eaction of the system to the door opening should be ins tant or delayed (main en-
trance door). Switch no. 2 must stay in the OFF position. See fig. 8.
check that all 3 terminals in the detector are connected together with short connecting loops.
install other JA60M magnetic detectors the same way.
Be sure to leave all JA-60M detectors uncovered and without batteries installed
.
3.2. JA60P - motion detector installation
By using the provided bracket, the JA60P detector can be installed on the wall or in a corner. The recommended installation height is from 2 to 2.5 meters above the floor. The detector’s coverage area is up to 12 meters and it has a detection angle of 120° (see fig. 11). Do not place the detector close to any heating/cooling vents or near any other object that often changes temperature. The JA60P should not be placed near any item that generates a strong electr omagnetic signal (transmitters, electronic regulators etc.). Avoid locations that have intense air circulation.
Fig.
9
Page 6
Alarm system JA-60 “COMFORT” - 6 - MDY51306
A.
Attach the bracket with the two provided screws, being sure that t he ar r ow inside the bracket is pointing up. We recom m end t o inst all one scr ew in the pre- punched hole on the lever of the tampering sensor (s ee fig. 9. A). The second hole can be easily punched out from the pre-form ed holes. Tighten the screws firmly, being sure that the bracket is not crooked.
B.
Click on the complete detector (including cover). Both tabs must click. Check that the detector is firmly fixed.
C.
Open the cover of the detector (press in on both sides 1/3rd from the top)
D.
Select Instant or Delayed reaction of the system to the detector’s trig­gering by using DIP SW 2 (see fig. 10)
E.
Install the other motion detectors t he sam e way, leaving them all
uncovered and without batteries
Fig.
10
4. Enrollment of detectors and remote controls
At this moment, all detector s (and wireless k eypads - if used) should be installed, without cover s and without power ( bat­teries). The control panel should be in the programming mode, displaying „P“ (see part 2.7.). As a maximum, 16 detectors and 8 remote controls (including wireless keypads) can be used with the control panel. One JA60A, wireless outdoor siren, can be enrolled as well. An additional JA60K control panel can be enrolled as a subsystem (see part 8).
4.1. Procedure for enrolling detectors and controllers:
a) The control panel must display “P” (programming mode – see 2.7). b) Press key 1 to enter the enrolling mode. c) A free detector position number (1 to 16) will be displayed, showing that the control panel is ready to accept an enroll-
ment signal from a detector. d) Install the two provided batteries into a detector and leave it uncovered. e) The detector will generate an enrollment signal, and the control panel will “beep” to indicate reception of the signal
(press F to select a louder “beep” sound) and the LED display will display the number of the next free position. f) Step by step, install batteries into all of the installed detectors and wireless keypads (if used). g) To enroll a RC11 remote control, press and hold both its buttons for 3 seconds. The RC11 controllers and JA60D key-
pads are enrolled to special positions which are displayed as c1 to c8 on the LED display (the system automatically
recognizes and differentiates the controllers) h) To exit the enrolling mode, press the N key (a „P“ will again be displayed on the LED display)
Note: if an item was not enrolled after its batteries were installed, it is because the control panel recognized its radio signal as a poor one. Items are only enrolled if their radio signal has a level whic h guar antees r eliable c ommunic ation. Check the detector’s batteries and try to enroll the problematic sensor once more. If it is not accepted by the control panel, you should change the location of the item. All items should be located 1 m or more from the control panel.
4.2. Enrollment or deletion of a detector or controller to/from a desired position (zone).
The control panel offers the next free position automatically in the enrolling mode. It is als o possible to select a desired position manually and to change the position of an enrolled item or to delete it. The pr ocedure is sim ilar to the one in part
4.1:
Press key 1 to enter the enrolling mode; a free position is displayed.
Use key 1 and 6 to scroll
(up and down) all control panel positions – 1 to 16 (detectors) – c1 to c8 (controllers & key­pads) – A (wireless siren) – J (sub control panel J A-60). The LED dis play shows the position number while the Battery LED indicates if the position is occupied (if the Battery LED is illuminated, it indicates that position is occupied).
Detectors and keypads are automatically enrolled when their batteries are ins talled. A remote control is enrolled only
after both of its buttons are simultaneously pressed and held for 3 seconds.
Note
: The control panel will not allow you to enroll a detector as a contr oller, and vice v ersa ( if you tr y to, the next s uit-
able position will be used automatically).
To change the position
of an enrolled item is simple.
Enroll it to the new selected position
(the item will „move“). If you enroll an item to an occupied position, the former item will be deleted and the new enrollment is valid. Only one item (detector, controller etc.) can be stored to each position.
Erase an enrolled item
the following way: in the enrolling mode
select
the corresponding
position
and then
press and
hold key 2
. If you press and hold key 3 all enrolled controllers (remote controls and keypads) will be erased. Pressing and holding key 4 will erase all enrolled items (detectors, controllers, siren and the sub system).A long beep will acknowledge successful erasing.
Page 7
Alarm system JA-60 “COMFORT” - 7 - MDY51306
4.3. Enrollment of detectors for partial (HOME) arming
The JA-60 system can be completely armed so that all enrolled detectors can trigger an alarm (when you leave the house). It can also be partially armed when somebody stays in a specified part of the house (HO ME arming). In partial arming, the control panel reacts only to detectors in position num ber s 1 to 10 and it ignores triggering of detectors in posi­tions numbered 11 to 16. If you want to use partial arming, enroll the detec tors that should be ignored into positions 11 to 16 (see part 4.2.).
Note: the control panel in partial arming ignores only intruder signals ( instant and delay) from detectors in positions 11 to
16. If there is any other signal (fire, gas leakage, tamper ing), the contr ol panel will react, no matter if it is in partial arming and regardless of the position of the triggered sensor .
5. Testing of detectors and controllers
The control panel should be in the programming mode for testing – (LED display shows „P“ )(see part 7.2. how to enter programming mode). If the control panel will not indicate a detector triggering during testing, it means that this detector was not enrolled (see note in part 4.1.).
5.1. JA60M magnetic door detector testing
Attach detector’s cover (the detector will automatically enter a testing mode for 5 minutes)
Opening and closing of the door/window will be confirmed by detector’s LED.
The control panel’s LED display will display the triggered detector’s number and it will mak e a beep (press F to select the
loudness of the beep).
5 minutes after the cover was closed, the detector will enter the normal mode and its LED indicator will be switched off (bat-
tery energy saving function). Open and close the detector‘s cover to reset the testing mode for an additional 5 m inutes if needed.
5.2. JA60P motion detector testing
Attach the detector’s cover and wait until the LED goes out. F rom this m om ent the detector will be in tes ting m ode for
5 minutes and each detected movement will be confirmed by detector’s LED.
The control panel’s LED display will display the triggered detector’s number and it will mak e a beep (press F to s elect the
loudness of the beep).
Confirm that the detec tor cover s the protec ted area as you expected (see diagr am in fig. 11). If you need another c ov-
erage pattern (long corridor, pet zone), you can get an optional detector lens from your distributor.
5 minutes after the cover was closed, the detector will enter the normal mode and its LED indicator will be switched of f
(battery energy saving function). Open and close the detector‘s cover to reset the testing m ode for an additional 5 m in­utes if needed.
fig.
11
Note: the motion detector in normal operating mode conserves battery energy. It will not indicate triggering with its LED. It will also block the movement sensor for a period o f 5 minutes after a movement is detected. This means that when users are in the protected area and they move frequently in front of the detector, it will transmit information about the movement to the control panel only once every 5 minutes. But when the users leave the area, the detector will be ready for instant detection 5 minutes after the last triggering. This system significantly prolongs the life time of the batteries. To change the period, for which the sensor is blocked after triggering from 5 min. to 1 min., press and hold the detector’s tamper switch when you install the batteries into it. This mode is suitable when you prefer more frequent transmission of the signal. However, the life time of the batteries is usually shorter, depending on how frequently the detector is triggered.
Page 8
Alarm system JA-60 “COMFORT” -
8 - MDY51306
5.3. Remote control and wireless keypad testing
Press any button on the remote control or enter a valid code on the
wireless keypad (1234 factory default setting)
The control panel’s LED display will display the controller’s number (c1 to c8)
and it will make a beep (press F to select the loudness of the beep).
This procedure allows you to test the remote control’s working range
Fig.
12
5.4. Recording detector’s location
After successf ully testing all detectors, we recomm end that you to record the location of the sensors directly on the control panel (area under the LED display). A suitable marker for this is provided. If you need to erase your rec­ord, use a tissue dipped in rubbing alcohol.
You can also record the location of the detectors on the user instruction card, and in the Comlink software as well. (See software instructions)
fig.
13
6. Finishing of the installation
Check that all detectors and other items have their covers attached.
If the control panel has a built in telephone dialer, record your voice mes s age and progr am the desired telephone num -
bers (see part 7.2.).
W e recommend to s et the date and time in the control panel (see part 7); The control panel s tores all events to an
events list in its the internal memory, including the date and time of the event. These details from the memor y can be viewed any time in the future via a connected PC and ComLink software. The PC can also be used for convenient set­ting of the control panel.
The system has a factory default setting, which allows you to use it without any other additional programming. If you
want to customize the control panel setting, see part 7.
Change the system Service Code to protect against unauthorized access to the programming mode (see part 7).
Exit programming
mode by pressing the N key. The control panel will then enter the disarm m ode. See user inst ruc-
tion card for information on how to operate the system.
If you have troubles with your system, see the Trouble shooting table in part 9.
Note: during testing and normal operation you should be aware of the following function: if four alarms are triggered from the same detector during the arming period, the detector will be bypas sed automatically for the rest of the arming period. This feature prevents unlimited number of alarms (and possible conflict with your neighbors! ) when for example impr oper ly closed doors inside the house are repeatedly moved by the wind. Such a bypass of problematic detector is reset with the disarming of the system.
This is the end of the basic installation procedure.
Page 9
Alarm system JA-60 “COMFORT” -
9 - MDY51306
7. Setting of the system
Functions of the system can be customized in the programming mode. Programming can be performed by entering programming sequences from the control panel keypad. A more convenient method is with the use of a connected PC and the ComLink software. Settings can also be downloaded directly from a central monitoring station. However, the setting of parameters and data for communi­cation with a monitoring station is not included in this manual and it is provided only to the providers of this service.
7.1. List of control panel programmable parameters Function
sequence
options
factory
d.
note
Enrolling of detectors and controllers
1
1& 6
scrolling, hold 2 to erase
position, 4 to erase all
-
Exit / Entrance delay
21x
x
= 1 to 9 (x 10sec.)
30sec.
Alarm duration
22x
x
= 1 to 9 (min.), for x=0 it
will be 10 sec.
4min.
Function of PgX output
23x
x
= 0 to 7 (0-Chime, 1-Fire, 2-Arm, 3-Panic, 4-Al arm,
5-Door, 6-Home, 7-NO AC
Chime
Function of PgY output
24x
x
= 0 to 7 (0-Chime, 1-Fire, 2-Arm, 3-Panic, 4-Al arm,
5-Door, 6-Home, 7-NO AC
Arm
User recorded Message & phone numbers: editable in the user mode*
25x
251 = YES 250 = NO
NO
Radio signal jamming regular testing
26x
261 = YES 260 = NO
NO
Regular communication check enabled
27x
271 = YES 270 = NO
NO
RESET enabled
28x
281 = YES 280 = NO
YES
Teaching of the control panel to a UC-216, etc.
299
will send enrolling signal
-
No code requested (effects F1, F2, F3, F4 & F9)
30x
301 = YES 300 = NO
YES
Partial (Home) arming enabled (F2)
31x
311 = YES 310 = NO
YES
Built in siren alarm enabled
32x
321 = YES 320 = NO
YES
Exit delay audible indication enabled
33x
331 = YES 330 = NO
YES
Partial arming exit delay audible indication
34x
341 = YES 340 = NO
NO
Entrance delay audible indication enabled
35x
351 = YES 350 = NO
YES
Arming & disarming chirp sound enabled
36x
361 = YES 360 = NO
NO
Built in siren in Disarm & Partial arming enabled
37x
371 = YES 370 = NO
YES
Wireless siren alarm enabled
38x
381 = YES 380 = NO
YES
Indication of system problems when arming
39x
391 = YES 390 = NO
NO
New Service Code setting
5
nSC nSC
nSC = new Service Code
(must be entered twice)
6060
Dialing method*
90x
901 = tone 900 = pulse
tone
Triggering of the dialer with a Panic alarm*
91x
911 = YES 910 = NO
YES
Triggering of the dialer with an Intruder alar m*
92x
921 = YES 920 = NO
YES
Triggering of the dialer with a Fire alarm*
93x
931 = YES 930 = NO
YES
Triggering of the dialer with a Tamper alarm*
94x
941 = YES 940 = NO
YES
Triggering of the dialer with a Technical alarm*
95x
951 = YES 950 = NO
YES
Telephone line checking enabled*
99x
991 = YES 990 = NO
NO
Store telephone numbers for voice message*
7xx..x F y
xx...x
= tel. number, y =
memory 1 to 4, pause = F0
1: 2: 3: 4: 5:
Pager dialing programming*
7x.xF9z..zF5
x..x
= provider tel. number
z..z
= pager number + mess.
Erase telephone number*
7F0Fy
y
= memory 1 to 5, entering
7F0F0 erases all
Record voice message*
8 0
(hold 0)
message:
Real time and date setting
4 hh mm DD MM YY
00 00 01 01 00
*
Setting of these parameters in following sequences is available only for a control panel with a built in optional dialer
Page 10
Alarm system JA-60 “COMFORT” -
10 - MDY51306
7.2. Control panel programming
Enter
F 0 SC
(SC = Service Code, factory default SC=6060) to enter the program ming mode (indic ated by a „P“ on the LED display). This can only be done while the panel is disarmed. In this m ode no alarm can be triggered. Detectors and other accessories can be enrolled, the c ontrol panel and telephone dialer parameter s can be set up and the system can be tested. By entering program ming sequences f rom the keypad (see bellow) the parameter s of the control panel can be set. T he control panel checks the validity of the entered sequences, and any incorrect code is r efused (sequence will be termi­nated). Any unfinished programming sequence can be terminated by pressing the N key.
To exit the programming mode, press the N
key („P“ will turn off). If any fault is indicated when you try to exit the pro-
gramming mode, the control panel will inform you about the problem (see programming sequence 39x for more details).
*
Setting of these parameters in following sequences is available only for a control panel with a built in optional dialer
7.2.1. Testing of the system
when the LED display displays
„P“
In the program m ing m ode (indicated by a „P“) no alarm c an be triggered. T he control panel will confir m r eceiving any sig­nal from an enrolled detector or another JA-60 wireless item. It will mak e a beep (press F to select the loudness of the beep) and the LED display will show which signal was received. Some detectors (JA60P, JA60M etc.) have an extr a test­ing mode, which is usually activated for 5 minutes after the detector’s cover is attached (see manuals of the particular detectors). Jus t as in the programming mode, the signals from all enrolled items are confirmed in the user mode ( confirmed by a “U”). The user m ode is accessible with the Master code and the supervisor of the system can use this m ode to replace batteries in items or for system tes ting. To open the user m ode enter F 0 MC (= Master Code) when the control panel is disarmed.
7.2.2. Enrollment (teaching) of wireless items
enter:
1
As a max imum 16 detectors and 8 contr ollers ( remote controls & keypads) can be enrolled to the c ontrol panel. A wireles s siren and an additional JA60K control panel (subsystem) can be enrolled as well.
press key 1
(while „P“ is displayed) to enter the enrolling mode. The control panel will display the next free position to
enroll a detector.
Use key 1 and 6 to scroll
(up and down) all control panel positions – 1 to 16 (detectors) – c1 to c8 (controllers & key­pads) – A (wireless siren) – J (sub control panel J A-60). T he display shows the position number while the Battery LED indicates if the position is occupied (If the Battery LED is illuminated, it indicates that position is occupied).
Detectors and keypads are automatically enrolled when their power is switched on (batteries are installed). A remote
control is enrolled only after both of its buttons are sim ultaneously pressed and held for 3 seconds. A subsystem con­trol panel will enroll after sequence 299 in entered while it is in its program ming mode. The system will not allow en­rollment of an item into a non- corresponding position (a detector c an not be enrolled into a controller position etc.). If you try to enroll any item into a wrong position, the control panel will automatically select a suitable position.
Control panel confirms enrollment
with a „beep“ (press F to select a louder “beep” sound). The LED display will
show the number of the enrolled item for 2 seconds and then it will display the number of the next free position.
To change the position
of an enrolled item is simple.
Enroll it to the new selected po sitio n
(the item will „move“) . If you enroll an item to an occupied position, the form er item will be deleted and only the new enrollment is valid. O nly one item (detector, controller etc.) can be stored to each position.
Erase an enrolled item
the following way: in the enrolling mode select the corres ponding position and then pres s and hold key 2 for two seconds. The item will be erased (confirm ed with a long beep). If you press and hold key 3, all en­rolled controllers (rem ote contr ols and k eypads) will be erased. Press ing and holding k ey 4 will erase all enrolled item s (detectors, controllers, siren and the sub system).
Wireless siren will generate enrollment signal
when its power is switched on (it will enroll to position A). If you need to enroll a siren which is already powered and it is not possible to easily switch its power off, you can enroll it the fol­lowing way: enter the enrolling mode and then enter the 6 digit siren production code (printed in the siren’s manual). The control panel will “request” the siren to s end its enrollment signal. The s iren will send the signal only if it has no current communic ation with any other control panel (This protects you from enrolling your neighbor’s siren) . Enrollm ent takes about five seconds after the code is entered.
Note: if an item was not enrolled after its batteries were installed, it is because the control panel recognized its radio signal as a poor one. Items are only enrolled if their radio signal has a level whic h guar antees r eliable c ommunic ation. Check the detector’s batteries and try to enroll the problematic sensor once more. If it is not accepted by the control panel, you should change the location of the item. All items should be located 1 m or more from the control panel.
Page 11
Alarm system JA-60 “COMFORT” -
11 - MDY51306
7.2.3. Exit / Entrance delay
sequence:
2 1 x
T o c hange the duration of the ex it and entrance delay (both of them ) enter
21x
(where x represents time in seconds x 10).
The delay can be selected from 10 to 90 seconds.
Example: to select an Exit and Entrance delay duration of 20 seconds, enter 212
Factory default setting is 30 seconds
7.2.4. Alarm duration
sequence:
2 2 x
T he alarm duration can be selected f rom 1 to 9 minutes (or 10 s econds) entering
22x
(where x represents time in m in-
utes, for x=0 the duration will be 10 seconds).
Example: to select an alarm duration of 5 minutes, enter 225
Factory default setting is 4 minutes
7.2.5. PgX and PgY outputs function
sequences:
2 3 x & 2 4 x
T he control panel outputs PgX and PgY can have differ ent func tions, depending on param eter x in the corresponding se­quence:
2 3 x
– determines triggering of
PgX
2 4 x
– determines triggering of
PgY
where x
represents the following functions:
0Chime
– triggered during the entrance delay (pre-alarm output)
1Fire
– triggered by a fire alarm (triggered by a smoke or a gas detector)
2Arm
– activated when the control panel is armed (complete & partial arming)
3Panic
– activated when a silent panic alarm is triggered
4Alarm
– triggered by any audible alarm (except panic alarm)
5 Door
– activated for 5sec. after F 3 entering (electric door lock opening)
6Home
– activated when the control panel is partially armed (Home arming)
7No AC
– triggered by an AC power failure
Example: the PgX will work as a Panic output when 233 is entered, PgY as Door output when 245 is entered.
Factory default setting: PgX=Chime, PgY=Arm
Note: the control panel also wirelessly transmits the PgX and PgY signals. Wireless output modules UC216 and UC222 can be used to receive the signals (see 8.1.3.). The function of the UC module output relays is determined by the 23x and 24x setting.
7.2.6. User recorded message and phone numbers: editing in the user mode*
sequence:
2 5 x
The User mode which is acces sible with F 0 “Master Code” is for battery replacement and s ystem testing. This setting enables the user to change the voice mes sage and telephone numbers of the built in dialer. If the c hanges are enabled, than programming sequences 6=tel. num bers programm ing, 7=voice message recor ding and 8=dialer testing are acces­sible in the User mode (see description bellow).
options:
2 5 1
changes
enabled
2 5 0
changes
disabled
(no programming in the User mode)
Factory default setting: changes disabled
7.2.7. Radio signal jamming testing
sequence:
2 6 x
When this function is enabled, the control panel will indicate trouble if the working band is jam med f or m ore than 30 sec­onds. Jamming will trigger an alarm when the control panel is armed..
options:
2 6 1
testing
enabled
2 6 0
testing
disabled
Factory default setting: disabled
Page 12
Alarm system JA-60 “COMFORT” -
12 - MDY51306
Note: in some locations the system can be repeatedly jammed for some period of time (near radar, TV station etc.). In these cases the JA-60 system can work without any problems because all important data is repeated, but the jamming test should not be enabled. The level of the signals and interference can be observed using the ComLink software's built in oscilloscope..
7.2.8. Regular communication checking
sequence:
2 7 x
T he control panel will check communication regularly with all enrolled items (detectors, keypads, siren etc.) when this function is enabled. If com munication is lost with any item, the control panel will indicate the fault of this item (when armed it will also trigger an alarm).
options:
2 7 1
checking
enabled
2 7 0
checking
disabled
Factory default setting: checking disabled
Note: in some locations with a strong radio interference (near radar, TV station etc.) the communication can be jammed periodically. The control panel can detect suc h a strong interference as a tempor ary loss of communication with an item. Even in this case, the JA-60 system is usually able to work without any problems, because all important data is repeated, but the communication check should not be used.
7.2.9. Reset enabled
sequence:
2 8 x
T he f actory default res et (see 7.3) c an be disabled. T his way no unauthorized future program m ing of the c ontrol panel will be possible.
options:
2 8 1
reset
enabled
2 8 0
reset
disabled
Factory default setting: reset enabled
Note: if the Master or Service code is forgotten when reset is disabled, the control panel res et will be possible only by manufacturer.
7.2.10. Enrollment of the control panel to a UC216, UC222, JA60K etc.
sequence:
2 9 9
T he control panel can send wireless data to output modules UC216 and UC222 (see 8.1.3.) and it can also work as a subsystem of another JA-60 control panel.
O pen the enrolling mode of the receiving device and then enter
299
and the control panel will generate the enrollment
signal.
7.2.11 No code requested for F1, F2, F3, F4 & F9
sequence:
3 0 x
If this parameter is enabled, no code is requested for f unctions F1, F2, F3, F4 and F9. W hen this parameter is dis abled, these functions can be used only when followed by a code (Master or User) – see the following table:
function / setting
300
301
arming „code“ F 1
partial arming F 2 „code“ F 2
door opening F 3 „code“ F 3
memory reading F 4 „code“ F 4
message listening F 9 „code“ F 9
„code“ = Master or User
options:
3 0 1 no code requested 3 0 0 code requested
Factory default setting: no code requested
Note: this feature is also selectable on the JA60D wireless keypad and it is independent from the control panel setting.
Page 13
Alarm system JA-60 “COMFORT” -
13 - MDY51306
7.2.12. Partial (Home) arming with F2
sequence:
3 1 x
In partial arm ing, the control panel reacts only to detectors in positions number 1 to 10 and it ignores the tr iggering of detectors in positions numbered 11 to 16 ( except sm ok e and gas detectors). Partial arm ing with F 2 can be disabled with this sequence.
options:
3 1 1
partial arming
enabled
3 1 0
partial arming
disabled
Factory default setting: partial arming enabled
7.2.13. Built in siren alarm
sequence:
3 2 x
T he built in siren sounds when any alarm is triggered (ex cept silent Panic alar m). The alarm indication c an be disabled with this parameter.
options:
3 2 1
siren
enabled
3 2 0
siren
disabled
Factory default setting: siren enabled
Note: this setting does not efect to the funct i on of the control panel’s external siren ‘s otput t erminal s..
7.2.14. Exit delay audible indication
sequence:
3 3 x
T he exit delay is indicated with „beeping“ of the control panel (for last five sec onds, the beeping is faster). The audible indication can be disabled with this setting.
options:
3 3 1
indication
enabled
3 3 0
indication
disabled
Factory default setting: indication enabled
7.2.15. Partial arming exit delay audible indication
sequence:
3 4 x
Par tial arming with F2 provides an exit delay for delayed reaction detectors in pos itions 1 to 10. The exit delay for partial arming can be indicated with „beeping“ of the control panel (for last five seconds the beeping is faster).
options:
3 4 1
indication
enabled
3 4 0
indication
disabled
Factory default setting: indication disabled
Note: when this indication is disabled, the confirmation of partial arming and disarming will automaticly be silent , regardless of the 36x setti ng.
7.2.16. Entrance delay audible indication
sequence:
3 5 x
T he entrance delay can be indicated with a rapid „beeping“ of the c ontrol panel. This indication can be disabled with this setting.
options:
3 5 1
indication
enabled
3 5 0
indication
disabled
Factory default setting: indication enabled
Page 14
Alarm system JA-60 “COMFORT” -
14 - MDY51306
7.2.17. Arming and disarming chirp sounds
sequence:
3 6 x
T he control panel confir ms arm ing with a beep and disarming with two beeps (3 beeps af ter disarm ing indicates us er in­formation on the LED display). These sounds can also be generated more loudly with the built in siren.
options:
3 6 1
siren chirps
enabled
3 6 0
siren chirps
disabled
Factory default setting: siren chirps disabled
Note: setting of chirp sounds is valid even if the siren is disabled for alarms with parameter 320. Partial arming is always silent, if sequence 340 is selected. Chirp sounds can also be gener ated with the JA60A wir eless siren (s elf-contained set­ting in the wireless siren).
7.2.18. Built in siren alarm in Disarm & Partial arming
sequence:
3 7 x
T he built in siren can be disabled f or alarms during the Dis arm & Partial arm ing of the control panel (while somebody is indoors). If the built in siren is completely disabled for alarms with parameter 320, this setting is moot.
options:
3 7 1
alarm in disarm & partial arming
enabled
3 7 0
alarm in disarm & partial arming
disabled
Factory default setting: enabled
7.2.19. Wireless siren alarm
sequence:
3 8 x
T he wireless siren alarm function can be dis abled with this parameter. This s etting will have no influence on the outdoor siren chirp sounds function if enabled in the siren .
options:
3 8 1
siren
enabled
3 8 0
siren
disabled
Factory default setting: siren enabled
7.2.20. Indication of system problems when arming
sequence:
3 9 x
The system regularly checks the conditions of all items (detectors, keypads etc.). This setting ensures that the us er will be warned with 4 rapid beeps after arming, if any component of the s ystem is not ready for arming. Cause of the problem ( f or example permanently triggered detector, los t communication etc.) will rem ain displayed on the control panel. If the user ignores this warning, the system will arm af ter exit delay, then an alarm will be triggered and finally the problematic item will be bypassed for this arming period. After disarming in such a mode, three beeps will be generated as well. When the indication is not selected, the problematic item will be bypassed when arming with neither warning nor alarm. If a permanently activated detector is deactivated during arming (for example your main door is not clos ed), the bypass of this detector will be canceled automatically and the detector will be ready to trigger an alarm af ter it is activated (if you close the door after the system is armed).
options:
3 9 1
warning
enabled
3 9 0
warning
disabled
Factory default setting: warning disabled
Page 15
Alarm system JA-60 “COMFORT” -
15 - MDY51306
7.2.21. Real time and date setting
sequence:
4 hh mm dd MM YY
T he control panel has a built in real tim e clock . All events are stor ed to the event mem ory including the time of the event. The clock should be set after the installation is complete.
Time Setting:
4 hh mm dd MM YY
where
hh = hours
(24 hr. cycle)
mm = minutes dd = day MM = month RR = year
Example: on Jun. 30 2001 at 17:15 enter: 4 17 15 30 06 01
After the control panel is powered, its internal clock’s default setting is: 00 00 01 01 00
Note: detail control panel event history can be viewed with a connected PC using ComLink software.
7.2.22. New service code setting
sequence:
5 nSC nSC
T he Service Code can be used to enter the programm ing mode. A new Service Code must be entered twice in the se­quence to avoid an error.
To change the code enter:
5 nSC nSC
where nSC is your new Service Code (four digits)
Example: to change service code to 1276 enter: 5 1276 1276
Factory default setting: service code is 6060
7.2.23. Telephone numbers entering*
sequence:
7xxx....xxFy
Store telephone numbers for voice message entering:
7 xx... xx F y
where
xx...xx
= telephone number
y
= memory number from 1 to 4
A telephone num ber can have a m aximum of 16 digits. A
pause
can be entered with
F0
(pause can not be entered as the firs t
digit).
Example: to store tel. number 02-123456 to memory no. 2 enter: 7 02 F0 12345 F2 Note: enter a pause (F0) after the last digit of a number which is calling a mobile phone. This way the number will be
called only once and the dialer will not check the line signals. (some mobile phone systems do not generate standard telephone line signals).
When activated, the dialer will
disengage all other devices hooked up to the phone line (telephone, fax..). It will then, one by one, call and play the user recorded message, for all programmed numbers. If the dialer makes a successful connection to a programmed number, it will not call that number again. If the number is busy, the dialer will make 3 more attempts to call it. Empty tel. number memories are skipped. If all memories are empty, the dialer is completely disabled.
To delete a telephone number
enter:
7 F0 F
y
where y is a memory number from 1 to 4 entering
7 F0 F0
will erase all tel. numbers, including the Pager number
Page 16
Alarm system JA-60 “COMFORT” -
16 - MDY51306
Store number to call Pager
(to memory number 5) entering:
7 xx..x F9 zzz....zz F5
where
xx...x
= provider prefix
F9
= separator
(it will wait for a provider’s signal and will switch to DTMF if not used)
zzz...zz
= pager number and numeric message and other specific codes (language selec-
tors, end of message etc.) if requested by the Paging provider
F5
= to store the number to memory no. 5
As a maximum 32 digits can be stored to memory # 5. Special characters can be entered with the following Fx codes:
pause
F0
∗∗∗∗
F7
####
F8
Example: enter 7 0611 F9 1 1234 555 F80 F5 if the provider prefix is 0611, the Pager number 1234 and the message 555. Number 1 after F9 is a language selector, code F80 represents #0
#0#0
#0 = end of message.
Note: some Paging providers also offer an option to send the message as an SMS to the GSM network. Consult your Paging provider for details if you have trouble sending a message to the Pager.
To delete the Pager number
enter:
7 F0 F5
If the memory number 5 is empty, no message will be sent to a Pager. Factory default setting: all memories from 1 to 5 are empty.
7.2.24. Voice message recording*
sequence:
8 0
Press shortly key 8 then press key 0 and hold it pressed while talking into the control panel’s front grid (max. 20 seconds) . After releasing the 0 key, the mess age will play back. The m es sage is s tored in non-volatile m emory and can be changed when ever you want to by repeating the above steps. Make the message clear and brief. The dialer repeats the m essage to each called number for 40 seconds.
7.2.25. Telephone dialer testing*
sequence:
8 9
Enter 89 and the dialer will call the programmed numbers once. You will hear the telephone line signals from the built in speaker during the test (if the dialer is triggered with an alarm in normal operation, it will call s ilently). Testing c an be ter­minated with the N key.
7.2.26. Dialing method*
sequence:
9 0 x
Enter:
9 0 1
for
tone
dialing
9 0 0
for
pulse
dialing (this option is blocked for some countries)
Factory default: tone dialing
7.2.27. Telephone dialer triggering*
sequences:
9 y x
W ith sequences fr om 91x to 95x you can select which alarms will trigger the telephone dialer to c all and which ones will not. Enter:
9 y x
where
y
alarm
1
Panic – silent
2
Intruder
3
Fire
4
Tampering
5
Technical trouble
x
reaction
0
not to call
1
to call
Example: if the dialer should not call when the system is tampered with, enter 940
Factory default setting: all alarms will trigger the dialer (it means 911, 921, 931, 941 & 951)
Page 17
Alarm system JA-60 “COMFORT” -
17 - MDY51306
7.2.28. Telephone line checking
sequence:
9 9 x
If this function is enabled, the dialer will check r egular ly if the telephone line is ready to make a phone call. If the line is not ready for more than 15 minutes, the control panel will indicate a telephone line failure (failure L). The f ailure will also be indicated, if you make (or receive) a phone call or fax longer than 15 minutes.
options:
9 9 1
checking
enabled
9 9 0
checking
disabled
Factory default setting: checking disabled
7.3. Factory default RESET
If you forgot the control panel codes or you have a control panel which does not have factory default s etting, perform the following procedure:
disconnect the AC adapter, back up battery and wait 30 seconds.
reconnect the back up battery and close the control panel cover
press and hold the 6 key while reconnecting the AC adapter.
when “
−−−−
“ is displayed, enter 060 (within 10 seconds)
reset is confirmed with “P” (panel is in programming mode)
Note: this procedure resets the factory default settings (s ee table 7.1.). The Master code will be 1234, Serv ice c ode 6060 and all user codes, detectors, controllers and other enrolled items will be forgotten. All telephone numbers will be erased. The reset will not erase event memory and information about the reset will be recorded there. Warning: if the Master code is forgotten when res et is disabled (with s equence 280), the c ontrol panel r eset will be possi­ble only by the manufacturer.
8. Possibilities to extend the system
The JA-60 is a kit, which can be tailor configured according to the size of the house or the needs of the user. See the structure of the system in fig. 14.
quick hom e door code
pgm
mem
8.1 Overview of JA-60 parts
Page 18
Alarm system JA-60 “COMFORT” -
18 - MDY51306
T he following description includes only the basic assort m ent of ac cess ories. In annex A of this m anual you will find a copy of the particular item manuals for your information. W e systematically introducing new and improved JA-60 item s to the market. You can get the most current information from your distributor.
8.1.1. Detectors
JA60M Magnetic door detector
- is equipped with a magnet. Movement of the magnet triggers the internal s ensor in the detector. It can trigger an Instant or Delayed intruder alarm and it also has built in tam per detector s. T here are inputs f or external sensors (see section 8.2.1. for more details).
JA60P Motion detector
– triggers an Instant or Delayed intruder alarm when the movement of a human body is detected.
It has built in tampering sensors and it uses digital processing of the signal for a high false alarm immunity.
JA60S Smoke detector
– triggers a Fire alarm when smoke is detected. It also has a built in siren.
JA60G Gas leak detector
– triggers a Fire alarm when any combustible gas is detected (natural gas, city gas, propane, butane etc.). The detector is powered directly form the AC power network and it wirelessly transm its information to the control panel. The JA60G has a built in siren and an output r elay. The relay, for example, can be wired to an electrical valve to turn off the gas supply when a leak is detected.
8.1.2. Controllers
RC11 Remote control
– can be used to Arm and Disarm the system. It can also be used to trigger a silent Panic alarm.
RC22 Panic button
- is a large size button, which can be easily attached in a selected location (under a desk , on the wall etc.). This button can be used to trigger a silent Panic alar m. The RC22 can be enrolled to the control panel the same way as the remote control.
JA60D Wireless keypad
– can operate the system in a similar way as the built in keypad on the control panel (arm ing, disarming, no code arming, partial arm ing, door opening and under dures s operation) . It has its own Master code and one User code, which can be programmed independently from the control panel’s codes.
8.1.3. Output devices
Wireless siren JA60A
is designated for outdoor use. It is powered from its own AC adapter and it has a built in back up battery. The siren wirelessly communicates with the control panel. It contains a high powered siren and a flashing light. Besides signaling alarms, it can als o provide arming and disarm ing chirps. T he siren has built in tamper detector s. Only one JA60A siren can be used with each JA-60 control panel.
Wireless outputs unit UC216
is a receiver, which receives signals from the JA-60 c ontrol panel. The unit has two output relays (X and Y, max. load 120V / 1A each). These r elays have identical functions as outputs PgX and PgY of the control panel (see 7.2.5). The unit requires external power from 12 to 24VDC or 15VAC. Multiple UC216’s can be used with a control panel and each UC216 can receive signals from more than one control panel.
Wireless output unit UC222
is a receiver, which receives signals from the JA-60 c ontrol panel. The unit has a power output relay (max. 250VAC / 5A). This relay has an identical function as output PgX of the control panel (see 7.2.5). T he unit is powered directly from the AC power (220 or 110VAC options) . Multiple UC-222’s can be us ed with a control panel and each UC-222 can receive signals from more than one control panel.
Use of UC216 and UC222 directly with JA-60 detectors
– the wireless output modules can also be used dir ectly with JA-60 system items (detec tors, keypads, remote controls). In this case the r eceiving unit reacts to the signals from the items which were enrolled to this unit. The item can be a part of the JA-60 alar m s ystem and its data is rec eived by both the control panel and the UC receiver. Or, the items can be used with UC units directly..
8.1.4. Telephone dialer module JA60X
– the control panel is available without the dialer (model JA-60K) or with the built in dialer (model JA-60KX). The JA60X dialer module can be easily installed to a JA60K contr ol panel as an after market access ory. The dialer can send a voice m ess age to four telephone num ber s and it can als o send a num er ic m es­sage to a Pager. The dialer regularly checks if the telephone line is ready, yet allows the line to be used as a normal phone line inside the house. The dialer can also com municate with a m onitoring station or with a remote PC. Information about the monitoring station communication is provided only to the monitoring station providers.
8.1.5. PC interface cable PC60A
– can be used to connect the control panel to a serial port (C OM1 or COM2) in your computer. Suitable SW, ComLink , is provided on a floppy disk. T he sof tware is a c onvenient way to setup the control panel, to supervise the system which is on line, to read, view and store data f rom the event mem ory and to record other information about the system. The s oftware can be installed under MS DOS or Windows system. You can learn m ore about the SW features, when you install it on your computer. Even without the PC60A interface cable you will be able to run the software in its off-line mode. The software has a built in help section.
If the control panel is equipped with the JA-60X dialer, then it is also possible to dial in the system f rom a re mote PC us­ing the ComLink SW.
For remote access
the PC must be equipped with
modem model JA60U
.
8.1.6. Control panel as a subsystem
Page 19
Alarm system JA-60 “COMFORT” -
19 - MDY51306
An additional JA-60 contr ol panel can be enrolled as a subsystem to the control panel (see 7.2.10). Each system then works as an independent system. However, any alarm from the subsystem will trigger the same k ind of alar m on the m ain control panel (the main control panel will display „J“ as the event source). If „BATTERY J“ is dis played on the main contr ol panel, it is informing the user that there is a power problem in the subsystem (low battery in a detector, AC failure, back up battery failure etc.). Using this method, multiple level subsystems can be chained.
8.2. Connection of other items to the system
In addition to wireless item s, s om e wire operated acces sories c an be connec ted to the control panel. T he JA60M detector can also be used to connect external wire operated sensors, serving as a classic control panel input zone.
8.2.1. Use of external sensors with JA-60M
The JA60M detector can be used to wire external sensors which have contacts on their outputs. For example, it can be used to protect multiple doors or windows (see fig. 16). The built in magnetic sensor of the JA60M can also be disabled (DIP switch num­ber 2 to position ON) and then the JA60M works only as an interface for external sens or s. T wo input loops ( T AMP & INP ter mi­nals) are activated when disconnected from the GND terminal.
INP
– when this input is triggered (disconnected from GND), the JA60M will send the same inform ation as if the built in magnetic sensor was triggered. Reaction of the system can be selected with DIP switch number 1 (ON= instant or 1= delayed).
TAMP
– when this input is triggered (disconnected fr om GND), the unit will send the
same information as if the built in tamper sensor was triggered.
Balanced loops
– the inputs INP & TAMP can also work as balanced loop inputs for higher safety of connected cables. If you install an End Of Line res istor 10k in the end of the loop (INP or TAMP), the JA-60M will automatically recognize this situation and from this mom ent it will react to any change of the resistivity (changes ± 30% or more will trigger the input).
Note: if either the INP or TAMP terminal is not used, it must be connected to the GND terminal. The procedure to enroll the JA-60M with external sensors is identical as described in section 4.1. If you change the DIP switch’s setting, the system will accept the new setting after the detector cover is closed.
fig.
16
8.3. Terminals in the control panel
There are terminals in the JA-60 control panel for use in wiring in external devices:
TMP
a pair of terminals to connec t the tamper switch of an ex ternal device. In norm al use, these ter minals should be connected together. Disconnecting of this loop has the same ef fect as the contr ol panel tamper switch being trig­gered. This input can also be used as a balanced loop for higher security of the connected cable. If you install an End
fig.15
Page 20
Alarm system JA-60 “COMFORT” -
20 - MDY51306
Of Line resistor 10k on the end of the loop, the control panel recognizes this situation and from this moment it will react to any change of the resistivity (change of ±30% or more will trigger the input).
PGX
is an output (opened collector of a switching transistor to GND, m ax. 12V, 100m A). The f unction of this output is deter­mined by the setting of parameter 23x in the programming mode (see 7.2.5). The control panel also wirelessly transmits the PGX signal and unit UC-216 can be used as a remote output of this signal (see 8.1.3).
PGY
is an output (opened collector of a switching transistor to GND, m ax. 12V, 100m A). The f unction of this output is deter­mined by the setting of parameter 24x in the programming mode (see 7.2.5). The control panel also wirelessly transmits the PGY signal and unit UC-216 can be used as a remote output of this signal (see 8.1.3).
C
is a common c ontact of the alarm output relay, max. load 60V / 1A,. T he relay is turned on dur ing any alarm of the con­trol panel.
NC
is a normally closed contact of the alarm output relay.
NO
is a normally open contact of the alarm output relay.
GND
is a common ground terminal of the power output (-).
SIR
is an external siren output. In normal mode there is a +U voltage. In the alarm mode there is a GND potential. Connect an ordinary external siren to +U and SIR terminals (max. load 1A). A back up s iren charging input s hould be connected to the GND and the SIR terminals (during an alarm, the charging will halt).
+U
is a back up +13.8V power output. The permanent load should not be higher than 50mA. A short time consumption from this output can be up to 1A (max. 10 m inutes). This output is fused and s upervised by the control panel. If it is over­loaded, a control panel failure will be indicated (fault C).
fig.
17
9. Trouble shooting table
Problem
possible cause
solution
alarm after first powering of the control panel
the control panel is not in factory default setting
perform a factory default reset, see
7.3 impossible to enroll a de­tector or a keypad
location of the item (or the control panel) is not suit­able and the radio signal level is too low (too far away or an obstacle is in the way of communication)
change location of the item, (fix it in the new place temporary at first and
then try it) a fault is indicated on the control panel and it is beeping
check display for the reason of the trouble. Press key N to disable beeping. The trouble information is stored in the event memory and it can be reviewed entering F4 anytime in the future
check the reason of the trouble in
user instructions and fix it, or call
the installer telephone line failure is
indicated and the phone
when you make a phone call longer than 15 minutes, it is interpreted by the system that the tel. line is not
if you have this problem more often,
disable tel. line checking in pro-
Page 21
Alarm system JA-60 “COMFORT” -
21 - MDY51306
works as normal ready. gramming mode JA60P movement detector repeatedly triggers alarms with no visible reason
check if there are: animals in the protected area (mice...), sudden changes of temperature or intense air circulation, movement of objects with temperature of about 37°C etc.
increase detector’s immunity (DIP
SW 1 to pos. 1), change location of
the detector or use an optional sen-
sor’s lens fault C is indicated on the control panel
technical problem of the control panel – failure of the power supply, blown fuse in the panel etc.
check AC adapter, backup up bat-
tery, fuses or call installer when activated, the tele­phone dialer calls a number multiple times
the telephone network (mobile network) does not use standard recognition signals and the dialer is not sure if the connection was successful or not
for calls to GSM network store F0
after the last digit to the number
(see 7.2.22) problem is not in this list call installer or the distributor for advice
local hot line number:
10. Recommended Professional installer basic rules
If you install the system for a customer, you should follow these rules:
make a drawing of intended location of the items, keeping in mind proper protection for the intended area.
if the customer requests reduction of the system (price reasons etc.), ask for a written confirmation that he does not
want the particular items you recommended (to avoid blame and liability if poorly covered area is robed in the future)
make a professional installation and do not forget to clean and be tidy.
it is very important to explain to the customer all functions of the system, to teach to him or her how to program access
codes, how to test the system and how to replace batteries in the items
offer your regular assistance for testing and battery replacement (we recommend annually)
make a written report signed by the customer, that the installation was finished properly and that she or he received
your training on how to operate and test the system
11. Specifications:
control panel power 230VAC, 50Hz (110VAC, 60Hz optional) back up battery 12V, 1,3Ah ref. 12V1K optional back up power output 13.8V, max. 50mA (permanent load), max. 1A (10 minutes) number of zones (detectors) 16 number of controllers (keypads) max. 8 events memory 127 latest events incl. date and time information built in siren 118dB working frequency 433.92 MHz (optional) RF approved according I-ETS 300 220 complies with EN 50131-1, 50131-5 telephone dialer* voice message to 4 numbers
numeric message to a Pager
digital communication to a monitoring station approved according* TBR21 working environment indoor use, -10 to +40°C
only for control panels equipped with the telephone dialer module
User instructions of JA-60
„Comfort“
Event indicators
– informs what happened in the syst em. Display specifi es from where the event is reported.
alarm
alarm triggered by an intruder, smoke, gas etc. See s pecification on the display
tamper
opened cover, damaged detector, exces sive number of attempt s to enter code etc. See specification on the display.
fault
power loss, lost communication with a detector etc., see specification on the display (confirm pressing key N)
battery
battery of the device specified on the display is low. See batt ery repl acement below.
Display
specifies event sourc e or mode of the control panel
event source:
1 to16
detector number
c1 to c8
controller or keypad number
C
control panel
A
wireless siren
J
sub system (other JA -60 system linked to fi rst system)
L
telephone line
d
digital line (PC interfac e)
P
programming mode
U
user mode (battery replacem ent & testing)
H
home (partial) arming (detec tors 11 to 16 are bypassed)
−−−−
waiting for more data to complete instruction
armed
continues = armed slow blinking = exit delay
Page 22
Alarm system JA-60 “COMFORT” -
22 - MDY51306
fast blinking = entrance delay
power
continues = AC power & back up battery are O.K. blinking = failure (AC power or back up battery) off = control panel is not powered
The system can be operated with the following codes:
Master code
– for arming, disarmi ng, code changes, entering of user mode for battery replacement and testing (factory default 1234)
User codes
– for arming and disarming onl y (al l are bl ank from the factory). Up to 14 different user codes can be set in the system for d ifferent users. This way is possible to differ between different users arming and disarming (using the ComLink software to read the control panel’s mem­ory or in the monitoring station)
Arming
– enter your code or press the A button on the remote control. Panel will beep and will start exit delay count down. You m ust leave the pro-
tected area during the exit delay.
Disarming
– enter your code or press the B button on the remote control. The panel will beep twice and will disarm. When you enter the protected area before disarming, the entrance delay count down will start. If disarm ing is c onfirm ed with t hree beeps, c heck the event indicat ors for inform ation (al arm memory, failure, low battery etc.).
To stop alarm
– enter your code or press the B button on t he remote control.
Panic alarm
– pressing and holding of both buttons of t he remote control for 3 sec. or entering F 7 before your code will trigger a silent panic alarm.
List of user functions:
code
arming or disarming
– depending on current mode (
code
= Master or User code)
F 1 arming without a code
– disarming is only poss i bl e with a code
F 2 partial (home) arming
- detectors 11 to 16 will be ignored (except Smoke & Gas detectors)
F 3 door opening
– will release electric door lock if connected to the system
F 4 memory reading
– indicators and display will show where and what happened, press the #4 key multiple times to go deeper into the memory
F 5 new M aster Code
– you must enter the current code and then the new one twice. Example: to change Master c ode from 1234 to 2738 enter
F5 1234 2738 2738
F 6
new User Code
– you must enter Master code, num ber of the new user code (01 to 14) and then the new user code. Example: user code
number 5 can be entered for combi nation 6789 while Master code is 2738:
F 6 2738 05 6789
To erase any User code completely, set it to combination 0000
F 7 panic alarm
– if you are under duress, enter
F 7 your code
, this will trigger a silent alarm; if the system is armed, it will also disarm
F 9 voice message listening
– to check the message of the telephone dialer
F 0 user mode
– entering
F 0 Master Code
will be confirmed by „U“ on the display. The control panel is now in user mode for battery replacement
or testing (exit with N)
N exit
– not completed funct i on code, memory reading, user mode etc.
Note:
functions F2, F3, F4 and F9 can be us ed only when followed by a code (Master or User), and only when this option is s elected fo r in the pro­gramming mode. Acoust ic indications and other features of the system can also be custom ized in the programming mode. Wireless k eypad JA-60D can have its own master code and one user code. Both codes can be diff erent than the control panel code.
Battery replacement
– when any detector or keypad asks for new batteries, switch the control panel to the user mode (see F0). Then open the cover of the detector (keypad) and replace its batteries with new ones (use only corresponding s ize alkaline bat teries). Clos e the device’s cover and test the device to confirm it i s working. To exit User mode, press the N key on the control panel.