The JA-154E Wireless access module with LCD, RFID and keypad
The JA-154E wireless access module with LCD, RFID and
keypad is a component
architecture enables users to create a combination whose size of installation perfectly meets their needs. The device should be installed by a trained technician with a valid certificate issued by an authorised distributor.
The wireless access module comprises the keypad (5), RFID card / tag reader (5), LCD display (4) and the first control segment (1). JA-192E segments can be used to extend the JA-154E unit by the required number of segments (the max. allowed amount is 20 on one unit). The k eypad cover (7) can be removed if the user prefers for full permanent access.
Figure: 1 – control segment; 2 – segment buttons; 3 – backlit activation
button; 4 – LCD display; 5 – access module with RFID card reader; 6 – tabs
for module opening; 7 – keypad cover screws
coiling the wires by turn ing th e segment by 360° - this will preven t any possible damage to the wires between the plastic parts ). Use this method to instal l all the required control segments. Finally push the socket cover in.
5. Insert four 1.5V alkaline AA batteries into the keypad.
6. Attach the base onto the selected place together with the segments using screws. If multiple control segments are required attach them onto the wall using screws as well (use the number of screws required).
7. Connect the segment wires to the internal connector of the keypad (8).
8. Insert the keypad into the b a se.
9. Proceed according to the control panel installation manual. Basic procedure: a. There must be a JA-110R radio module installed in the
control panel with a reliable communication range to the keypad.
b. When batteries are inserted, the yellow LED starts to light
permanently which indicates that the keypad has not been enrolled to the system yet.
c. Go to the F-Link software, select the required position in
the Devices window and launch enrollment mode by clicking on the Enroll option.
d. Press the backlit activation butt on (3) – the keypad is thus
enrolled and the yellow LED indicator goes off. (This can take a few sec.). An enrollment signal can al so be sent by inserting the batteries.
10. When you have completed i nstallation, insert descriptive labels behind the segment plastic windows and close them. Label printing is a part of the F-Link s oftware (Devices window, at the keypad position – Interna l settings), or you can use the label printer.
Note:
Enrolling the module to the syste m is possible by enterin g the production code (9) via F-Link s oftware o r by a producti on code re ader. All digi ts under the production code are requi r ed (1 40 0 -00 -0 00 0-0 00 1).
To comply with th e EN 50 131- 3 nor m it is n ecessar y to fix the cov er tab by
the screws from the accessori es. In picture no 1 the cover t abs are fixed by the arrows.
2
1
ABCD...123
!
k
c
i
l
C
3
||
|
JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
Figure: 8 – control segment connector; 9 – production code; 10 – terminals;
11 – mini USB connector; 12 – batteries; 13 – tamper contact
Installation
1. Press the four tabs (6) o n the sides (see 1s t figure) one by one and release the keypad from the plastic base.
2. When installing more control s egments, first remove the s ocket cover on the 1
3. Remove the plastic windows from the segments (by levering on both sides of the segment near the buttons).
4. Always connect the segment wires to the connector of the previous segment and click them into each other (we recommend
st
segment.
!
k
c
i
l
C
Figure: Insertion of a label into a control segment
4
Setting the properties
Go to the Devices window in the F-Link sof tware. When you are at the keypad position, use t he Internal settings opt ion. The partic ular unit is displayed and it i s possible to set it s propert i es. It is possibl e t o assign the required functions to individual segments (controlling of sections, section status signalling, alarm triggering, PG output control, PG output stat us signalling, etc.). More details are available in the F-Link software.
A common segment (up to 2 of them allowed on one keyboard) simulates the simultaneous pressing of several segments which are placed on this key board and which control sec tions. The selection of sections which are assigned t o the comm on segment is performed b y F-Link SW, the Devices window. At the keyboard position select Internal setti ngs / a nd Com m on segm ent 1 (2 ) and mark the segm ents which will be operated en bloc. The selected sections will be set / unset after pressing a button on the c ommon segment. If the states of the segments which are operated by the common segment are mixed, then only the segments that need changing will be set / unset. If partial setting is enabled for some segments, then the common segment respects this: 1 s t . pres s = p arti al l y s ett ing, 2nd p res s = f ull s ett in g. I t i s not suitable to combine a common segment with a common section
The JA-154E wireless access module with LCD, RFID and keypad 1 / 2 MLU56205
Page 2
The JA-154E Wireless access module with LCD, RFID and keypad
The indication of t he com m on segm ent is : all segm ent s s et = green,
some set (partia lly set) = yell ow, a ll sectio ns fu lly set = red.
Automatically shutting down the module
The module saves its energy by shutting down the optical indication of system status, keypad back light and RFID reader 10 sec. after its last activity with a user. The keypad still keeps communication with the control panel and it c an signal f or example: an entrance delay. Complete waking up i s done when you press the cover of the keypad, other wise by activation of the magnet ic door contact connected to the IN terminal (see next paragraph).
When the parameter „Entrance delay time and alarm are triggering the keypad“ (default) is enabled, the keypad is als o full y woken up when these events occur.
Disabling this parameter gives you a longer battery life time. In this case the keypad cannot wake itself and will not indicate the system status optically, and ac oustic signalling can be delayed a few sec.
Alternative power
The keypad can be powered from an external 12V DC power supply via the PWR and GND terminals. The DE 06-12 power supply has the advantage of hidden installation. The keypad does not sleep if external power is used. It permanently communicat es with the control panel and it i ndicates the system status according to the Devices / Internal settings. Leave the batteries inside the keypad. When the mains power is cut off, the keypad will work from the batteries.
Connection of an external door detector
The keypad has an input terminal for external door detector connection. The input (IN) reacts to disconnection from the common ground. The reaction of this input is delayed, and is link ed to the keypad address. The input has a status reaction. According to the settings, the keypad can be completely woken up by triggering the external detector.
Caution: this type of waking up is good to us e when the k eypad i s powered from the external power supply otherwise every ac tivation tends to shorten battery lifetime.
the JA-190T card reader. We strictly recommend connecting the USB straight to the PC, connection via a USB HUB can reduce the reliability.
7. Press and hold the backlit act ivation button (3).
8. When the button (3) is pressed, connect t he miniUSB cable to the connector on the module (11).
9. Switching to the mode for upgrading fi rmware (according to t he version of the keypad in about 5 sec.) is indicat ed by the yellow LED flashing or by the backlit activation but ton flashing green and yellow (now you can release the button (3)).
10. Then continue as if you are doing an upgrade via F-link software: Control panel ĺ 8pgrade Firmware ĺ FKRRVH WKH upgrade file pack (it is a part of the F-link i nstallation pack , or it can be independently published for downloading, file type *.fwp)
11. F-Link shows a window with a device listing, select the USB (typi cally at the first positi on).
12. Then press OK and perform the upgrade for the selected device.
13. Disconnect the miniUSB cable, reinsert the batteries and reassemble the keypad.
14. Check the keypad via
F-Link, Devices/Internal settings.
According to the changes which have been done during the upgrade, previous settings might stay or settings could be erased to default. When a reset has been done you can reload the previous settings by the
Import button and restore them
with no negative influence on the new firmware.
15. When the FW upgrade has been done, the main menu could be expanded. In this case the new options are set to default. Check their settings and adjust according to user requir em ents.
16. Perform a last check and try out the functions by some tests.
Battery replacement
The system automatically reports a Low Batt from the keypad. Before you change th e batt eries, s witch the sys tem t o servic e mode, otherwise a tamper alarm will be triggered.
Technical specifications
Power 2 x alkaline batteries AA (LR6) 1.5 V 2400 mAh Typical life time 1 - 2 year(s) according to the settings Communication band 868.1 MHz, JABLOTRON protocol Communication range 200 m (open area)
Unit modifications
If you need to change the segments (add or take out), release them by leveri ng on b ot h si des of t he se gm en t nea r t he b ut to ns . Whe n yo u hav e finished changing the amount of segments the new JA-192Es are not always immediately visible in the F-Link software. For synchronization, click on t he Upload button.
Note: If there is a request to modify the keypad hardware, always remove the batteries and disconnect the external power supply.
Power input from external supply 0.5 W RFID frequency 125 kHz Dimensions 102 x 145 x 33 mm Weight 350 g Classification Grade II According to EN 50131-1, EN 50131-3, EN 50131-5-3 Operational environment EN 50131-1 II. Indoor general Operating temperature range -10 to +40 °C Also complies with ET SI EN 300330, E TSI E N 300220
FW upgrade
1. Upgrades can only be done by a Service technician.
2. F-Link software is necessary for upgrades.
3. Start the F-Link in Off-line mode and open the appropriate
database.
4. Open the keypad by pressing on the tabs (6).
5. Remove the batteries and possible external power supply.
6. Connect the miniUSB cable to the USB port on the PC.
(Caution: the miniUSB is not in the accessories of the keypad, control panel or any other devic e. You can use the cable from
EN 50130-4, EN 55022, EN 60950-1
JABLOTRON ALARMS a.s. hereby declares that the JA-154E is in complian ce with the essent ial requirement s and other relevant provisions of Directive 1999/5/EC. assessment can be found at www.jablotron.com - Technical Support section
Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use. For more detailed information visit