The JA-150TP Wireless indoor thermostat
The JA-150TP is a component of the JABLOTRON 100 system.
It serves for the measuring and regulation of temperature by controlling
an assigned PG output of the control panel. The thermostat is fully
supported by MyJABLOTRON, which allows to control the temperature
and change its settings remotely. There is a graph of the currently
measured temperature and its history in MyJABLOTRON. Pre-set limits
can be set for every thermostat notification about overshooting
or undershooting a temperature. It also has a weekly program where
it can switch between comfort and economical temperatures, manual
mode and Standby mode. In total (including wireless and BUS versions)
up to 4 thermostats can be used in the system. Thermostat can control
only one PG output. The product should be installed by a trained
technician with a valid certificate issued by an authorized distributor.
a.s.
||
|
JABLOTRON ALARMS
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
Figure 1: 1 – Knob combined with a button; 2 – Cover tab
Description
The thermostat measures temperature based on which it switches
a selected PG output on / off in the control panel. The currently
measured temperature is displayed on the LCD display where the user
can find additional information, see Figure 3. When the currently
measured temperature is out of the pre-set temperature range (-10 °C
to +70 °C) then it displays Hi °C or Lo °C.
The individual temperature levels of the thermostat are shown
on Figure 2. All temperature levels can be set in MyCOMPANY. Values
(levels) from
on the thermostat, see Control / operation.
Figure 2: A – Low temperature, B – Temperature in Standby mode,
C – Lower temperature limit pre-settable by user, D – Economical
temperature, E – Comfort temperature, F – Upper temperature limit
Control / operation:
Operation is very simple. Setting (changing) the temperature
is performed by turning the knob (1) and performing confirmation
by pressing it (or automatically after 5 sec).
To see the current time and day of the week on the LCD display
perform a double press (2x /1 sec) of the knob (1).
In the Program and Manual mode it is possible to show the required
temperature by pressing the knob (1).
The Economical and Comfort temperature can be done
in the thermostat internal menu. Enter the internal menu by pressing
the knob (1) longer – approx. 6 sec. The first option to be set
is the Comfort temperature (
Turning the knob (1) performs selection of the required temperature.
By pressing the knob (1) confirm the pre-set value and continue with
settings of the Economical temperature (symbol
flashes). By pressing the knob (1), store all the pre-set values and
return to the main screen. If the thermostat internal menu is open for
10 sec with no activity (pressing or turning the knob), it will automatically
quit the internal settings without saving the pre-set values.
(D) to (E), are editable also directly
pre-settable by user, G – High temperature
symbol is ON and °C flashes).
is ON and °C
Figure 3: 3 – Internal settings entry from F-Link SW/ communication
fault; 4 – Symbols of comfort
5 – Days of week; 6 – heating activated when thermostat is blocked;
7 – Standby mode activated; 8 – Heating, flashingŸ – thermostat
blocked by open window for example; 9 – Axis of heating periods;
10 – Symbols for showing the temperature, time and text; 11 – Low
battery indicator; 12 – Showing of pre-set / required temperature
Thermostat operation modes:
The thermostat suits various premises types, therefore it offers
a few operating modes. By pressing the knob (1) for approx. 3 sec
it can switch between its individual modes. The thermostat can
be pre-set via the MyJABLOTRON application very comfortably,
see the MyJABLOTRON chapter.
Program:
and based on the difference between the temperatures it switches
the heating via a PG output (the heating symbol
PG output is switched on). The user can simply change the heating
temperature, see Temporary manual temperature.
The heating plan can be set individually for every day. Each day can
have up to 4 heating intervals for the Comfort temperature.
The minimum heating period is 15 minutes. Setting of the Program
mode is possible only using the MyJABLOTRON or MyCOMPANY.
Temporary manual temperature (TMT):
disappears. The thermostat remains in this mode until the next manual
temperature correction or until the moment when the pre-set program
initiates next change between Comfort and Economical temperature.
Manual:
Ÿsymbol appears.
the
Standby
:
is displayed on the LCD and the „Stby“ symbol appears in the upper
right corner. The Standby mode temperature can be set
in MyJABLOTRON or MyCOMPANY. This mode is meant to keep
the temperature level to protect the premises against freezing when
there is nobody inside for longer time.
Other functions
Blocking: The PG output switching can be blocked by a status mode
detector such as a magnetic detector, by another PG output
or by the status of a section. It ensures that the thermostat won´t heat
when a window or a door is open or any other blocking condition
is fulfilled. Blocking of the PG output is indicated by Heating (8) symbol
flashing. When blocking is activated and the currently measured
temperature drops below the Standby mode pre-set temperature, then
blocking is overcome and the PG output is switched on – anti-freeze
protection (signalled by the symbol (6)). For situations when
the temperate would tend to still drop, the thermostat reaction
to a low temperature can be set, see chapter Setting the thermostat
properties in the F-Link software.
:
and economical temperature;
The thermostat has a weekly program.
It switches between the Economical
and Comfort (4) temperature in pre-set
intervals. This temperature is compared
with the currently measured temperature
Ÿ is ON when the
It serves for a fast temperature change
when the Program mode is activated.
To trigger TMT mode turn the knob (1).
All elements indicating Program mode
remain the same, only the
In Manual mode set required temperature
by turning the knob (1) which is then
constantly maintained. The measured
temperature is only visible on the LCD.
When the PG output is switched on then
This mode can only be activated and
deactivated from MyJABLOTRON.
The thermostat maintains the temperature
that was pre-set for the Standby mode.
The currently measured temperature
/ (4) symbol
The JA-150TP Wireless indoor thermostat 1 / 3 MMX53105

The JA-150TP Wireless indoor thermostat
Switching to the economical temperature when the system
is set: The thermostat in the Program mode can react
to setting / unsetting the section, to which it is assigned. When
the section is set, it switches at once to the Economical temperature
(if the thermostat has already heated to the Economical temperature,
nothing changes). The thermostat still follows a pre-set timed heating
plan and the PG output switches on when it goes from the Economical
to Comfort temperature even if the section is already set.
So the heating can be activated earlier than when the users come back
home and unset the system. It is valid for a fully and partially set
sections. All settings can be performed in the MyCOMPANY.
Installation
The product can only be used in an indoor environment. Install the
thermostat 1.5 m above the floor in a place where there is good natural
air circulation. Don´t install the thermostat where the measuring
can be influenced by drafts, sunlight, heaters or any other undesirable
effects.
Figure 4: 13 – Battery holders; 14 – production code;
Installation procedure:
1. Release the front thermostat housing by pressing the tab (2),
by screwdriver for instance.
2. Install the rear part of the thermostat at the chosen place (tab facing
down).
3. Foll ow the control panel installation manual. Basic procedure:
a. There must be a JA-11xR radio module installed in the system.
b. Go to the F-Link software, select the required position
in the Devices tab window and launch enrollment mode
by clicking on Enroll option.
c. When you insert both batteries into the battery holder (13)
it sends an enrollment signal and the thermostat is thus enrolled
to the required position. When the enrollment procedure is done
successfully (proper communication) the exclamation symbol (3)
disappears from the thermostat’s LCD display.
4. Put back the front thermostat part and close it.
5. Using F-Link SW and the option Internal setting at the required
thermostat select the PG output which will be controlled and other
system settings. See more details in the chapter: Setting
the thermostat properties.
6. Other settings can be done in the MyCOMPANY. If the system has
not been registered yet, it must be registered first (if needed ask
your authorised distributor for help). When the system is registered
already and only the thermostat has been added, then leave
the service mode to upload new system configuration
to MyJABLOTRON (ussually within 15 minutes).
7. When registration is finished, pre-set the thermostat via
the MyCOMPANY application, see the chapter Setting
the thermostat properties in MyCOMPANY.
:
Notes
The thermostat can also be enrolled to the system by entering
its production code (14) in the F-Link software. All digits
of the production code are required. (Example: 1400-00-0000-
0001).
Setting the thermostat properties in the
F-Link software
Basic settings can be done in the F-Link SW in the internal settings
of the specific thermostat. Where the following parameters can be set:
Controls PG: (*No) Select which PG output will be controlled
by the thermostat. The reaction of the PG has to be set to ON / OFF
and must not be inverted. Thermostat can control only one PG output.
Reaction to high temperature: (*None) The selection of the offered
options determines the reaction when a high temperature is reached.
Fire alarm, Fire instant, Report A, Report B, Report C, Report D,
Overheating or None.
Reaction to low temperature: (*None) The selection of the offered
options determines the reaction when a low temperature is reached.
Report A, Report B, Report C, Report D, Freezing or None.
High temperature: (*60 ºC) The temperature can be set in the range
of -9.9 °C to +70 ºC. When a pre-set temperature is exceeded,
the selected reaction is triggered. The value of the high temperature
always has to be higher than the low temperature.
Low temperature: (*3 ºC) The temperature can be set in the range
of -10 °C to +70 ºC. When the pre-set temperature is undershot,
the selected reaction is triggered.
Setting the thermostat properties
in MyCOMPANY
For the settings of all thermostat parameters it is necessary to have
the Jablotron 100 system registered – see the Installation chapter to get
the details. A service technician pre-sets the thermostat
in the MyCOMPANY. (it is supported web and mobile applications).
In the MyCOMPANY, open Installation management. At the
selected system on the Devices tab select the cogwheel symbol
at the required thermostat position. The setting window with following
parameters is open:
Highest and lowest temperature configurable by the user (-10 ºC
to +40 ºC).
Comfort and Economical temperatures: are pre-settable by
the user in the range of the lowest temperature limit to the highest
temperature limit.
Heating plan:
days and the weekend or individual for every day. Using the button
add individual intervals when the thermostat should heat to the Comfort
temperature. If an interval should be erased, click on it and when the
symbol appears, by clicking on it the selected interval can be erased.
Activate economical temperature when: None / Partially set / fully
set section to which the thermostat has been assigned.
Temperature in Standby mode:
determines the temperature which is going to be maintained in Standby
mode or when Blocking is activated.
High temperature (from -9.9 ºC to +70 ºC), see the chapter called
Setting the thermostat properties in the F-Link software.
Low temperature
Setting the thermostat properties in the F-Link software.
Hysteresis (from 0 °C to 5 ºC) For example, if the hysteresis is set
to 1 °C and the required temperature is 30 °C, then, the PG output
is switched on when the temperature drops below 29 °C and the PG
output is switched off when it exceeds 30 °C.
Temperature correction: (from -12.8 ºC to +12.7 ºC) This option can
fix any possible thermostat measurement deviation from the real
temperature in the premises.
can be the same for the whole week, different for week
(from -10 ºC to +15 ºC) this
(from -10 ºC to +70 ºC), see the chapter called
MyJABLOTRON
In the MyJABLOTRON thermostats are shown at Thermostats
and thermometers, where all the measured values of all thermostats
and thermometers enrolled to the system are saved. This data is stored
and available for future use. Reading the temperatures is done
automatically at a 5 minute interval.
For every thermostat:
The current status is displayed (Name, Heating / Temperature
reached, Current temperature, Required temperature, Mode, Graph
of measured temperature)
The temperature can be temporarily changed
The operation mode can be changed (Program, Manual, Standby)
Temperatures are shown in a graph in the selected time period
and can be exported in various formats for future processing.
The user has authorization to edit some settings directly
in the MyJABLOTRON application. Select Settings
to open settings window with following parameters:
Basic settings:
Comfort and Economical temperatures
Heating plan
Advanced settings:
Temperature in Standby mode
Hysteresis
Temperature correction
(0-5ºC)
Æ
Thermostats
The JA-150TP Wireless indoor thermostat 2 / 3 MMX53105

The JA-150TP Wireless indoor thermostat
For description of every single option see the chapter called Setting
the thermostat properties in MyCOMPANY.
Æ
In Settings
and lower limits and the time period in which the temperature
is monitored can be set. When the temperature overshoots
or undershoots the pre-set limit, a notification is sent by SMS, e-mail
or as a PUSH notification for the smart application.
The system reports if the batteries are nearly drained by a battery
symbol (11) on its LCD display. The system doesn´t have to be
switched to Service mode to replace the batteries because there
is no tamper contact.
Always use batteries of the same type and the same supplier and
always replace both of them.
The thermostat supports wireless firmware upgrading. It can
be performed by F-Link software in Service mode.
1. Go to F-Link: Control panel – Update firmware. In the offered
list the JA-150TP should appear. If the F-Link SW detects
the existence of newer firmware than that in the thermostat,
it is automatically checked (ticked) for upgrading.
2. Press the OK button to perform the update of the selected
devices.
3. When the update is finished, check the internal settings
of the thermostat on the Devices tab – Internal settings.
4. Test the thermostat’s functions.
Temperatures for a selected thermostat the higher
Battery replacement
FW upgrade
Technical specifications
Power 2x AA 1.5 V (LR6) alkaline batteries
Typical battery lifetime approx. 2 years
Communication frequency 868.1 MHz, Jablotron protocol
Communication range aprox. 300 m (open area)
Dimensions 66 x 90 x 22 mm
Weight 60 g
Operational temperature range -10 to +70 °C
Measuring range -10 to +70 °C
Temperature regulator class I. (according to (EU) no. 813/2013)
Contribution of regulator to seasonal efficiency
Operational environment according to EN 50131-1 II. Indoor general
Temperature measuring sensitivity ±0.1 °C
Also complies with ETSI EN 300 220, EN60950-1
Can be operated according to ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-150TP is in a
compliance with the relevant Union harmonisation legislation: Directives
No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2009/125/ES, 2011/65/EU.
The original of the conformity assessment can be found at
www.jablotron.com - Section Downloads.
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use.
Caution: batteries are not included
6 DFFRUGLQJWR(8QR
EN 50130-4, EN 55022
a.s.
||
|
JABLOTRON ALARMS
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
The JA-150TP Wireless indoor thermostat 3 / 3 MMX53105