JA-150M Wireless magnetic detector with 2 universal inputs
||
|
JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
The JA-150M is a w ireless component of the JABLOTRON 100 system.
It is a magnetic detector w ith two configurable independent inputs. The
detector is also designed to detect the h andling of roller blinds, if it is
equipped with a CT-01 roller detector. Small movements are filtered out so
that wind blasts do not cause false alarms. It occupies two separate
enrollment addresses in the control panel. The JA-150M can be used with up
to two LD-81 flood detector. The product can be installed by a certified
technician wi th a valid certificate issued by an authorized distributor.
Installation
mode according to table 2. The detector immediately reads t he NO/NC status of
all input terminals when the battery is inserted. The detected NC or NO state is
taken as the default (standby). T he input terminals IN1 an d IN2 also work with 1k
resistor-balancing.
from NC to NO it is necessary to insert the batter y when the input is
disconnected.
Setting the detector properties
This can be done b y D IP switches 1-4 on the detector PCB. Select the required
Example: When there is a requirement to change the default logic of IN1
Description of inputs:
IN1 – Input terminal for connection to detector no. 1
IN2 – Input terminal for connection to detector no. 2
(Norm/Puls/Rol1/Rol2 can be set for IN1, IN2)
TMP – Input terminal for tamper contact connection
COM – Common term inal for inputs IN1, IN2 and TMP
MG – Internal magnetic detector
Description of input modes:
Norm – status mode, the detector signals activation and deactivation of
the input terminals
Pulse – pulse mode, the detector just signals activation (whether turning
off or turning on depen ds on the default NO/NC standb y mode).
Off – input disabled
Rol1, Rol2 – roller mode, which reacts to repeated pulses and short
activating (NO) pulses with a sensitivity selectable in to two levels: Rol1 =
activation after 3 pulses within a 2 minute period; Rol2 = activation after 5 pulses
within a 2 minute period. When this loop is disconnected lon ger then 0.5s, a
tamper alarm is triggered. After input triggering in Rol4/Rol2 mode the detector
doesn´t react to the next acti vation for 10 sec.
LD-81 – mode for connecting LD-81 floo d detectors
Mode DIP1 DIP2 DIP3 DIP4 MG IN1 IN2
0
1
2
3
4
5
6
7
8
Figure: 1 – Place for locking screw, 2 – Cover tab,
3 – LED indication, 4 – Batter y holder, 5 – Pro duction code,
6 – DIP switch settings, 7 – terminals, 8 – Co ver tamper contact
Axis X Y Z
Switching distance (mm) 21/14 17/16 55/24
Disconnecting distance (mm) 25/16 17/18 60/27
Table 1: Spacing on a non-magnetic surface. Distances are issued for
usual permanent magnet / whorl-shaped magnet.
There are two different types of permanent m agnets in the package - a stand ard
magnet in a plastic housing (A) and a whorl-shaped magnet (B) for use in places
where t here is not enough space for a standard magnet or for counter-sinking the
magnet into a door or window’s inner frame. The right positions for placing both
types of magnets against the internal magnetic sensor are shown above as well as
the reaction areas for magnets in millimeters in three axes of movement (see.
table 1).
1. Open the detector cover by pressing the tab (2).
2. Screw the rear cover onto the required place. If it´s needed, put the
cables through the rear plastic base. T he length of cabels to the d etector
should not exceed 3 m ; choos e the pl ace of installation accordingly.
3. Attach the permanent magnet to the moving part of the door (window)
with screws. The lower edge of the permanent magnet has to be at the
same height as the lower edge of the detector (the magnet can be
mounted on the left or right side).
4. Connect the wires from external contact to the required terminals if they
are used.
5. It is not necessary to use any wire jum pers if none will be used (this is
also valid for tamper).
6. Set the DIP switches according to your needs (see Tab. 2).
7. Proceed according to the control panel installation manual. Basic
procedure:
a. There must a JA-110R radio m odule installed in the system.
b. Go to the F-link softw are, select the required position i n the Devices
window and launch the enrollment mode by clicking on the Enrol l
option.
c. Insert the batteries (mind the correct polarity). The enrolment signal is
transmitted when the batter y is inserted into the detector. Note – the
detector occupies 2 positions (each input has its own position).
8. Close the detector cover and test its functioning.
Note: The detector can also be enrolled into the system by entering its
production code (5) in the F-link software (or using a bar code scanner). All
numbers stated under the bar code shall be entere d (1400-00-0000-0001).
You can find the production code on the sticker under the bar code, glued on
the battery holder.
JA-150M wireless magnetic detector with 2 universal inputs 1 / 1 MND51104
9
10
11
12
13
14
15
Table 2: Setting the detector properties (= DIP switc h ON)
The system sends a report automatically when the battery is low. Remember to
switch the system to Service mode before changing the batteries (otherwise a
tamper alarm will be triggered). Warning: The input terminals have to be in
standby mode because when a n ew battery is inserted, the detector reads
the inputs and takes the current status as default. (This is not valid for an
internal magnetic contact).
Power 1x alkaline batter y type LR6 (AA) 1.5 V
Please note: Battery is not included
Typical battery lifetime about 2 years
Communication band 868.1 MHz, JABLOT RON protocol
RF range approx. 300 m (open area)
The maximum length of cable for external detectors 3 m
Dimensions 109 x 24 x 22 mm
Classification Grade 2
According to EN 50131-1, EN 50131-3, EN 50131-2-6, EN 50131-5-3
Operational environment EN 50131-1 II. Indoor general
Operational temperature range -10 °C to +40 °C
Complies with ETSI EN 300220, EN 50130-4, EN 55022, EN 50950-1
Can be operated according to ERC REC 70-03
Norm Off Norm
Norm Off Pulse
Norm Off Rol1
Norm Off Rol2
Pulse Off Pulse
Pulse Off Rol1
Pulse Off Rol2
Off LD-81 LD-81
Off Norm Norm
Off Norm Pulse
Off Norm Rol1
Off Norm Rol2
Off Pulse Pulse
Off Pulse Rol1
Off Rol1 Rol1
Off Rol2 Rol2
Battery replacement
Technical specifications
JABLOTRON ALARMS a.s. hereby declares that the JA-150M
module is in compliance with the essential requirements and other
relevant provisions of Directives 1999/5/EC, 2011/6 5/EU. The
original of the conformity assessm ent can be found at
www.jablotron.com - Technical Support section
Note: Although this product does not cont ain any harmful materials
we suggest you ret urn the product to the dealer or directly to the
producer after use. For more detailed information visit
www.jablotron.com.