JA-150M Wireless magnetic detector with 2 universal inputs
||
|
JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
The JA-150M is a w ireless component of the JABLOTRON 100 system. It is a magnetic detector w ith two configurable independent inputs. The detector is also designed to detect the h andling of roller blinds, if it is equipped with a CT-01 roller detector. Small movements are filtered out so that wind blasts do not cause false alarms. It occupies two separate enrollment addresses in the control panel. The JA-150M can be used with up to two LD-81 flood detector. The product can be installed by a certified technician wi th a valid certificate issued by an authorized distributor.
Installation
mode according to table 2. The detector immediately reads t he NO/NC status of all input terminals when the battery is inserted. The detected NC or NO state is taken as the default (standby). T he input terminals IN1 an d IN2 also work with 1k resistor-balancing.
from NC to NO it is necessary to insert the batter y when the input is disconnected.
Setting the detector properties
This can be done b y D IP switches 1-4 on the detector PCB. Select the required
Example: When there is a requirement to change the default logic of IN1
Description of inputs:
IN1 – Input terminal for connection to detector no. 1 IN2 – Input terminal for connection to detector no. 2
(Norm/Puls/Rol1/Rol2 can be set for IN1, IN2)
TMP – Input terminal for tamper contact connection COM – Common term inal for inputs IN1, IN2 and TMP MG – Internal magnetic detector
Description of input modes:
Norm – status mode, the detector signals activation and deactivation of
the input terminals
Pulse – pulse mode, the detector just signals activation (whether turning
off or turning on depen ds on the default NO/NC standb y mode).
Off – input disabled Rol1, Rol2 – roller mode, which reacts to repeated pulses and short
activating (NO) pulses with a sensitivity selectable in to two levels: Rol1 = activation after 3 pulses within a 2 minute period; Rol2 = activation after 5 pulses within a 2 minute period. When this loop is disconnected lon ger then 0.5s, a tamper alarm is triggered. After input triggering in Rol4/Rol2 mode the detector doesn´t react to the next acti vation for 10 sec.
LD-81 – mode for connecting LD-81 floo d detectors
Mode DIP1 DIP2 DIP3 DIP4 MG IN1 IN2
0 1 2 3 4 5 6 7 8
Figure: 1 – Place for locking screw, 2 – Cover tab,
3 – LED indication, 4 – Batter y holder, 5 – Pro duction code,
6 – DIP switch settings, 7 – terminals, 8 – Co ver tamper contact
Axis X Y Z Switching distance (mm) 21/14 17/16 55/24
Disconnecting distance (mm) 25/16 17/18 60/27
Table 1: Spacing on a non-magnetic surface. Distances are issued for usual permanent magnet / whorl-shaped magnet.
There are two different types of permanent m agnets in the package - a stand ard magnet in a plastic housing (A) and a whorl-shaped magnet (B) for use in places where t here is not enough space for a standard magnet or for counter-sinking the magnet into a door or window’s inner frame. The right positions for placing both types of magnets against the internal magnetic sensor are shown above as well as the reaction areas for magnets in millimeters in three axes of movement (see. table 1).
1. Open the detector cover by pressing the tab (2).
2. Screw the rear cover onto the required place. If it´s needed, put the
cables through the rear plastic base. T he length of cabels to the d etector should not exceed 3 m ; choos e the pl ace of installation accordingly.
3. Attach the permanent magnet to the moving part of the door (window)
with screws. The lower edge of the permanent magnet has to be at the same height as the lower edge of the detector (the magnet can be mounted on the left or right side).
4. Connect the wires from external contact to the required terminals if they
are used.
5. It is not necessary to use any wire jum pers if none will be used (this is
also valid for tamper).
6. Set the DIP switches according to your needs (see Tab. 2).
7. Proceed according to the control panel installation manual. Basic
procedure: a. There must a JA-110R radio m odule installed in the system. b. Go to the F-link softw are, select the required position i n the Devices
window and launch the enrollment mode by clicking on the Enrol l option.
c. Insert the batteries (mind the correct polarity). The enrolment signal is
transmitted when the batter y is inserted into the detector. Note – the detector occupies 2 positions (each input has its own position).
8. Close the detector cover and test its functioning.
Note: The detector can also be enrolled into the system by entering its production code (5) in the F-link software (or using a bar code scanner). All numbers stated under the bar code shall be entere d (1400-00-0000-0001). You can find the production code on the sticker under the bar code, glued on the battery holder.
JA-150M wireless magnetic detector with 2 universal inputs 1 / 1 MND51104
9 10 11 12 13 14 15
Table 2: Setting the detector properties (= DIP switc h ON)
The system sends a report automatically when the battery is low. Remember to switch the system to Service mode before changing the batteries (otherwise a tamper alarm will be triggered). Warning: The input terminals have to be in
standby mode because when a n ew battery is inserted, the detector reads the inputs and takes the current status as default. (This is not valid for an
internal magnetic contact).
Power 1x alkaline batter y type LR6 (AA) 1.5 V Please note: Battery is not included Typical battery lifetime about 2 years Communication band 868.1 MHz, JABLOT RON protocol RF range approx. 300 m (open area) The maximum length of cable for external detectors 3 m Dimensions 109 x 24 x 22 mm Classification Grade 2 According to EN 50131-1, EN 50131-3, EN 50131-2-6, EN 50131-5-3 Operational environment EN 50131-1 II. Indoor general Operational temperature range -10 °C to +40 °C Complies with ETSI EN 300220, EN 50130-4, EN 55022, EN 50950-1 Can be operated according to ERC REC 70-03
               
Norm Off Norm Norm Off Pulse Norm Off Rol1 Norm Off Rol2 Pulse Off Pulse Pulse Off Rol1 Pulse Off Rol2
Off LD-81 LD-81 Off Norm Norm Off Norm Pulse Off Norm Rol1 Off Norm Rol2 Off Pulse Pulse Off Pulse Rol1 Off Rol1 Rol1 Off Rol2 Rol2
Battery replacement
Technical specifications
JABLOTRON ALARMS a.s. hereby declares that the JA-150M module is in compliance with the essential requirements and other relevant provisions of Directives 1999/5/EC, 2011/6 5/EU. The original of the conformity assessm ent can be found at