The JA-150A Internal wireless siren
The JA-150A is a component of the JABLOTRON 100 system. It
is used for alarm indication inside a building. It can also be used for
other acoustic indications (PG outputs, entry/exit delays, door bell).
Pressing the siren button can silence the alarm (= confirmation of a
person’s presence in the building) or trigger panic alarm (optional
function). The siren is equipped with a backup battery for cases
when AC dropouts can happen. The siren should be installed by a
trained technician with a valid manufacturer’s certificate.
Installation
The siren can be installed directly on the plaster or into an electro
installation box.
1. Remove the siren body (button) from the frame – by levering in
the vertical crevice (1.) with a screwdriver.
2. Press the tabs (2.) and remove the frame (3.).
3. Prepare a suitable opening and pull the power cable through.
4. Attach the plastic base to the selected place using screws.
5. Connect the power suppl y cable and battery.
6. Assembly the siren together. Attention, the tamper sensor (6)
must be positioned above the magnet (5) in the plastic base.
7. Proceed according to the control panel installation manual.
Basic procedure:
a. When the power supply is connected, the yellow LED (9)
starts flashing to indicate that the siren has not been enrolled
into the system.
b. Go to the F-Link program, select the required position in the
Devices window and click on the Assign option – the
enrollment mode is then launched.
8. Press the siren button (at the top or at the bottom) – the siren is
thus enrolled and the yellow LED indicator goes off.
Figure: 1 – battery; 2 – battery connector; 3 – 230V AC power supply
connection terminal; 4 – Siren and power supply segment connector;
5 – magnet on the tamper segment; 6 – tamper sensor; 7 – internal buttons;
8 – serial number ; 9 – LED indicator;10 - piezo-siren;11 – button tabs
Warning: If the battery is low (reported to the control panel) the
siren is not able to fully perform all its functions
The siren power supply can only be
installed by a person with adequate
electrotechnical qualification.
WARNING: This device is directly
connected to mains electricity
Setting of properties
Go to the Devices tab in the F-Link software. When you are at
the siren position, use the Internal settings option to open a dialog
window where you can set: (* indicates default settings).
Sections: defines for which sections the siren should indicate an
alarm and possibly also entrance / exit delays and system setting. The
default setting is indication for all section s.*
Reaction: defines whether the siren should indicate IW* (internal
warning) or EW (external warning) signal. Alarm indication with siren
chirps can also be completely disa bled (other funct ions remain active) .
Siren tones: intermittent*, continuous
Maximum siren time: 1, 2, 3*,4, 5 minutes.
Higher volume: YES / NO* - affects only entrance/exit delay
signalling and sounds indicating PG output triggering.
Beeps during section control: YES / NO* - if enabled, the siren
chirps once after setting, twice after unsetting and three times when
unsetting after an alarm. It only does so f or selected sect ions.
Entrance and exit delay beeps: YES / NO* if enabled,
it indicates exit and entrance delay of the sele cted se ction s.
Acoustic signalling of PG output activity:
Sound indication can be set for each PG output:
Chirp 1 – slow chirping - 1 per second (for the whole period when the
PG is active)
Chirp 2 – rapid chirping - 2 per second (for the whole period when
the PG is active)
Chirp 3 - 1 chirp when the PG is activated, 2 chirps when the PG is
deactivated
Chirp 4 – a long 20 sec chirp when the PG is activa ted
Function 5, 6, 7 – door bell melodies
Siren function priorities:
The siren sound enjoys the highest priority, the chirp du ring cont rol
has a lower priority and the PG output activity indication has the
lowest priority (PG1 has a higher priority than PG 2 etc). The chirp
with higher priority always terminates the chirp with lower priority.
System reaction to the pressing
of the siren button
The default setting is that pressing the siren button during alarm
mutes the siren and concurrently confirms a person’s presence in
the building (a report is sent).
It is possible to change the siren butt on s ettings in or der t o func tion
as a panic alarm button in the Devices window in the F-Link software.
In such a case the system responds to the pressing with a panic
alarm in the section to which the siren has been assigned.
When the system is in service mode, long pressing of the button
can test its functioning.
Technical specifications
Power supply / wattage 230 V AC / 0.3 W
Backup / recharge time min. 12 h / max 72 h
Battery / lifetime 3.6 V; 170 mAh / 3 years
/ minimum voltage when loaded 3.0 V
/ maximum voltage when unloaded 4.5 V
Communication band 868.1 MHz, JABLOTRON protocol
Communication range approx. 300 m (unrestricted area)
Siren piezo electric, 85 dB/m
Dimensions 90 x 90 x 35 mm
Classification Grade II
according to EN 50131-1, EN 50131-3
Operational environment according to EN 50131-1 II. Indoor general
Operating temperature range -10 to +40 °C
Also complies with EN 50130-4, EN 55022, EN 60950-1
Can be operated according to ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-150A is in
compliance with the essential requirements and other relevant provisions
of Directive 1999/5/EC. The original of the conformity assessment can
be found at www.jablotron.com
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use. For more detailed information visit
www.jablotron.com
- Technical Support section
.