JA-111M Bus magnetic mini detector
When connecting the module to the system bus, always switch the power off.
JABLOTRON ALARMS a.s. hereby declares that the JA-111M is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The original of the conformity assessment can be found at www.jablotron.com - Technical Support section
Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use. For more detailed information visit
www.jablotron.com.
The product is a component of the JABLOTRON JA-100
system. It is used for the detection of opening doors, windows, etc.
The detector has a status reaction (reports its activation and deactivation).It should be installed by a trained technician with a valid certificate issued by an authorized distributor.
Installation
Fig: 1 – cover tab; 2 – LED indicators (yellow and red)
1. Open the detector cover by pushing the tab (1).
2. Select the right hole for the cable in the back part of the cover
and break the membrane, put the cable thru and screw the detector onto the chosen place.
b. Go to the F-Link software, select the required position in the
Devices window and launch enrollment mode by clicking on the Enroll button.
c. Open the detector cover and press the tamper contact (8) –
the module is enrolled and the yellow LED goes off.
5. Close the detector cover.
Internal settings of the detector
The detector properties can be set in the Devices tab of the F­Link software. When at the detector position, use the Internal settings option to open a dialog window where you can set:
(* default settings)
LED indication enabled* / disabled: Allows the user to disable activation indication with a red LED.
Note:
The detector can also be enrolled into the system by entering
its production code (7) in the F-Link software or on a keypad (or using a bar code scanner). All numbers stated under the bar code shall be entered (1400-00-0000-0001).
The distance between the transmitter and the permanent
magnet should be the shortest when the door is closed. For a diagram of the activation distances in all of axis see the picture below. Distances are valid for position on non-magnetic materials.
3. Connect the bus cables (3) to the terminals (6).
Technical specifications
Power from control panel bus 12 V (9…15 V) Current consumption in standby mode 5 mA Current consumption for cable choice 5 mA Dimensions 55 x 27 x 16 mm Classification Grade 2 according to EN 50131-1, EN 50131-2-6 Operational environment according to EN 50131-1 II. Indoor general Operating temperature range -10 to +40 °C Also complies with EN 50130-4, EN 55022
Fig: 3 – bus cable; 4 – yellow fault indicator; 5 – red detector activation
indicator; 6 – digital bus terminals; 7 – production code; 8 – tamper contact;
9 – magnetic sensor; 10 – permanent magnet with its alternative position
4. Proceed according to the control panel installation manual. Basic
procedure: a. When the device is powered, the yellow LED starts flashing
repeatedly to indicate that the module has not been enrolled into the system.
JA-111M Bus magnetic mini detector 1 / 1 MLM51501