JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
JA-111A RB BUS external siren
The JA-111A RB is a component of the JABLOTRON 100 system.
It is used for system alarm indication outside a building and as a pre-sensing
tamper detector. It can also be used for supplementary acoustic signalling.
The siren is equipped with a backup battery which powers the siren during
tamper alarm reporting when the connection to the digital bus is severed.
The JA-111A RB is completed by assembling two parts, the with the
JA-111A-BASE-RB base PCB and one of a few optional covers in the
JA-1X1A-C-xx series. The covers are supplied as a colour combination of
cover and flasher. The siren should be installed by a trained technician with
a valid certificate issued by authorized distributor.
For combinations of colour and cover material, see the following table:
Cover type Colour and cover
material
JA-1X1A-C-GR
JA-1X1A-C-ST
JA-1X1A-C-WH
JA-1X1A-C-GR-B
JA-1X1A-C-ST-B
JA-1X1A-C-WH-B
Grey plastic
Stainless steel sheet
White plastic
Grey plastic
Stainless steel sheet
White plastic
Installation
The siren should be
installed on a vertical
wall, with the flasher
facing downwards.
Avoid installing the siren
near the gutters and on
other places where
there is a danger of ice
accumulation.
2 – two piezzo sirens;
3 – NiCd battery with
reusable battery strap;
5 – bus-cable; 6 – PCB;
8 – mounting hole with
9 – front cover screw;
connecting the front
1. Open the external
2. Push the bus cable (5) through the hole (4) in the bottom part and
3. Attach the siren to a suitable place using 2 screws through the holes (1)
Figure: 11 – bus terminals; 12 – LEARN (enrollment) button; 13 – tamper
4. Connect the bus cable to the terminals (11).
5. Connect the backup battery to the connector (17).
6. Proceed according to the control panel installation manual. Basic
Figure:
1 – mounting hole;
4 – hole for cable;
7 – spirit level;
tamper detection;
10 – string with clip
cover for easy
installation
siren cover by releasing the screw (9).
secure it using the plastic tabs.
and (8). The spirit level can be used for easy installation (7).
When connecting the siren to the
system bus, always switch the power
off.
sensors; 14 – production code; 15 – high-intensity red LED flashers;
16 – yellow fault indi cator; 17 – backup battery connection;
18 – piezo siren connection (attention: high voltage)
procedure:
a. When the siren is switched on, the yellow LED (16) indicates that
the siren has not been enrolled into the system.
Strobe colour
Red
Blue
b. Go to the F-Link software, select the required position in the
Devices tab and launch the enrollment mode by clicking on the
Enroll option.
c. Press the enrollment button (12) – the siren is thus enrolled and the
yellow LED indicator goes off.
7. Put back the siren cover and attach it using the screw (9).
8. The siren can be tested by F-Link software by clicking the Test button in
the internal settings option. After clicking the button the siren sounds for
three minutes and after that flashes for one minute.
Internal settings of the siren
The siren properties can be set in the Devices window of the F -link
program. When at the siren position, use the Internal settings option to
open a dialog window where you can set: (default settings are
marked *):
Sections: to set for which sections the siren should indicate an alarm, as
well as setting chirps. The default setting is indication for all sections.
Reaction: defines whether the siren should indicate EW* (external
warning) or IW (internal warning); Alarm indication can also be disabled
completely (other functions remain enabled).
LED indication: Red* / Blue. According to the siren cover you
can choose the colour of the LED indicators.
Siren chirps: interrupted*, uninterrupted.
Alarm indication length: 1, 2, 3*, 4, 5 minutes.
Chirps during section control YES / NO* if enabled, the siren chirps
once upon setting and twice upon unsetting and three times upon unsetting
after an alarm. The signalling only works for the preset sections.
Siren flashing options: During alarms */ (flashes) 30 minutes after an
alarm. Extended flashing can be terminated by new system setting or
cancellation of alarm indication in the system (with a keypad).
Flashes every 60 seconds: YES / NO* optional indication of siren
functioning.
PG output activity indication
The siren can indicate PG output activity with its chirps.
Chirp 1 – slow chirping - 1 per second (for the whole period when the PG
is active)
Chirp 2 – rapid chirping - 2 per second (for the whole period when the PG
is active)
Chirp 3 - 1 chirp when the PG is activated, 2 chirps when the PG is
deactivated
Chirp 4 – a long 20 sec chirp when the PG is activated
Sound priorities
The siren sound has the highest priority, the control chirps have a lower
priority and the PG output activity indication has the lowest priority (PG1 has
a higher priority than PG2 etc). The chirp with a higher priority always
terminates the chirp with a lower priority.
Loss of communication with the control panel
If the power supply wire is severed, the siren keeps sounding and flashing for
3 minutes (this function does not work in service mode). If the system power
supply is disconnected due to a discharged control panel battery (long lasting
power failure) then the siren does not sound and flash.
Backup battery replacement
The system reports a low battery automatically. The control panel must be
in service mode before you start changing the battery otherwise a tamper
alarm will be triggered. Use a BAT-4V8 battery only.
Technical specifications
Power from control panel digital bus 12 V (9…15 V)
Current consumption in standby mode 5 mA
Current consumption for cable choice 50 mA
Backup battery NiCd pack 4.8 V / 1800 mAh
lifetime approx. 3 years
- minimum loaded voltage 4.0 V
(replace the battery when voltage drops down this value)
- maximum unloaded voltage 6.0 V
reusable battery strap
Piezoelectric siren 110 dB/m (with fully charged battery)
Dimensions 200 x 300 x 70 mm
Classification Security grade 2
according to EN 50131-1, EN 50131-4
environment class IV general outdoor -25 °C to +60 °C
Security grade IP44
Also complies with EN 50130-4, EN 55022,
EN 60950-1, EN 50581
JABLOTRON ALARMS a.s. hereby declares that the JA-111A RB is in
a compliance with the relevant Union harmonisation legislation: Directives
No: 2014/35/EU, 2014/30/EU, 2011/65/EU. The original of the conformity
assessment can be found at www.jablotron.com - Section Downloads.
Note: Although this product does not contai n any harmful materials we suggest
you return the product to the dealer or directly to the producer after use .
For more detailed information visit www.jablotron.com.
JA-111A RB BUS external (outdoor) siren 1 / 1 MLQ51113