JABLOTRON JA-110M для магнито-контактных детекторов – 2 входа Jablotron -JA-110M_MLM51102_manual_inst_EN.pdf

JA-110M Bus module for magnetic detectors - 2 inputs
The product is a component of the JABLOTRON JA-100 system. It is used to connect door detectors and is equipped with two separate inputs offering a wide range of configuration options. The module is enrolled to two consecutive positions in the system. The detector has a status reaction (reports its activation and deactivation).It should be installed by a trained technician with a valid certificate issued by an authorized distributor.
Installation
When selecting the right location for the module, bear in mind that the wires leading to a detector (detectors) should not be longer than 3 m.
II.
2
1
Fig: 1 – cover tab; 2 – yellow fault indicator; 3 – red input activation indicator
1. Open the module cover and take out the PCB (by pressing the tab)
2. Insert the bus and detector cable(s) and attach the plastic base with screws.
When connecting the module to the system bus, always switch the power off.
3. Insert the PCB back and connect the bus cables to the terminals.
I.
3
4
BUS
5
6
7 8
IN 1
IN 2
1400- 00- 0000-0001
Fig: 4 - yellow fault indicator; 5 – red input activation indicator; 6 – bus terminals; 7 – tamper contact; 8 – detector terminals; 9 – production code
4. If you want to use a balanced loop for better protection of the
detector connection use a 1k resistor in series with a detector (see the following figure). The balance function must be enabled in the detector settings.
GND
9
max 3 m
IN 1
IN 2
GND
1k
5. Proceed according to the control panel installation manual. Basic
procedure: a. When the device is powered, the yellow LED starts flashing
b. Go to the F-Link program, select the required position in the
c.
6. Close the module cover.
repeatedly to indicate that the module has not been enrolled into the system.
Detectors window and launch enrollment mode by clicking on the Enroll option. Press the tamper contact (7) – the module is enrolled and the yellow LED goes off. Warning – the module is enrolled to two consecutive positions (each input is enrolled to one position).
Internal settings of the module
The Internal settings option (on the first or second occupied module position) in the Detectors window in the F-Link program opens a dialog window where you can set each input: Input reaction 1(2): Disabled – no reaction, Unbalanced – reacts to contact disconnection, Balanced – a 1k resistor is used in serial connection with the detector. The input is activated when the resistance decreases below 700 ohms or increase s above 1300 ohms. Input reaction delay: A time filter for increasing false alarm immunity – it can be set from 0.1s to 300s to define how long the INP1(2) input must be triggered in order to be activated in the control panel. Inverted input reaction: The default settings for the input reaction is NC (normally close). Enabling this option sets the reaction to NO (normally open). LED indication enabled: Allows the user to disable activation indication with a red LED.
the following options for
Technical specifications
Power from control panel bus 12 V (9…15 V) Current consumption in standby mode 5 mA Current consumption for cable choice 5 mA Maximum length of the connection cable between the input and the detector 3 m Dimensions 100 x 40 x 24 mm Classification Grade II according to EN 50131-1, EN 50131-3 Operational environment according to EN 50131-1 II. Indoor general Operating temperature range -10 to +40 °C Also complies with EN 50130-4, EN 55022
JABLOTRON ALARMS a.s. hereby declares that the JA-110M module is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC. The original of the conformity assessment can b e
found at www.jablotron.com - Technical Support section Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the producer after use. For more detailed information visit www.jablotron.com.
JA-110M Bus module for magnetic detectors - 2 inputs MLM51102
Loading...