The AC-160-C Wireless multifunctional relay
The AC-160-C wireless multipurpose relay 1 / 2 MLZ54600
Installation
The device can only be connected to mains electricity by a person who has an adequate electrotechnical qualification
It provides single pole switching which doesn´t provide safety isolation
.
The relay module is meant to be installed into plastic electrical boxes. There must be a JA-11xR radio module enr olled to the control panel to ensure cooperation with the system. It occupies one position in the JA-100 system.
Figure: 1 – Learn (enrol l) / set button; 2 – LED indicators;
3 – Relay output termi nals; 4 - Mains power terminals 230 V AC
1. Connect the power wires (230 V AC) to the terminals (4), and
turn the power on.
2. Basic procedure:
a. When the relay has been turned on, the LED´s RELAY
goes t o green and ERR goes to yellow permanently to indicate the relay has not been enrolled to the system yet and als o a detector has not been enrolled to the relay either.
b. Using F-Link s oftware, select the required position in the
Devices window and launch the enrollment mode by clicking on the Enroll option.
c. By pressing the Learn/Set (1) button longer than 3 s (until
the yellow LED starts flashing) the relay sends an enrolling signal to the c ontrol panel. Enrolling to the control panel is confirmed when t he yellow LED goes off.
3. Test the relay function by pressing the button (1). After approximately 0.5 s the output relay is actived. A switch ed relay is indic ated by a red LED (RELAY).
4. Connect the controlled device to the terminals (3).
Note s:
- The rel ay goes to standby mod e, when the mains is cut off or communic ation is lost with the control panel f or more than 1 minute. When the relay has lost communication with an enrolled device then the restoration interval is 20 minutes (l ost communic ation is indicated by permanent lighting of the ERR yellow LED). W hen the mains or communic ation with a control panel is restored, th e relay retur ns to the status given by pre-defined settings within 2 minutes (for wireless detectors with a periodical link test such as the JA-151M, it can take up to 9 minutes).
- It is also possible to enrol the relay to the system by entering the pr oduction c ode via F- Link software. A sticker with the production code is on the rear side of the relay. All digits in the code are requir ed (1400-00-0000-0001)
- JA-18x detect ors are not c ompatible with the relay
- Multiple-input detectors such as the JA-150M are always enrolled to one position and the r elay is only trig gered by the first input of the detector. The second input has no effect.
- After each Learn/Set button press t he relay changes its status after 0.5 s, as well as when an enrollment signal is transmitt ed or while entering the relay’s service mode – indicated by the RELAY LED. W hen a c ontrol panel is already enr olled, the function can be disabled, s ee the settings below.
Setting the module properties
The module properties can be set in th e Devices window of the F-Link s oftware. W hen at the modul e position, use the Internal settings option to open a dialogue window where you can
set the following options:
Manual relay controlling: Enabled: a short learn button (1) press changes the relay state (switches ON/OFF). Manual control is always possible even if communication with the c ontrol panel is being performed. Manual c ontrol c an be completely disabled.
Reacts to PG(s): This option allows s election of the way the relay is triggered by on e or more contr ol panel PG outputs .
Common timer: Determines the period f or which the output r elay will be switched ON. The function differs according to the pre-s et mode of the ass ociated detector. This par ameter serves for setting the timing of the switc hing impulse. A status-mode type of detector with an “extended copy” reaction set makes the relay stay active for the whole time even when the detector goes to standby. Th e timer can be set in pre-defined steps or the desired value up to 23h 59min 59s
Enrolled devices: This window includes 64 positions for enrolling detect ors. There are two options to enroll them to the relay: the first is to ent er the production code into the production code f ield and the second is enrolling them via the Learn/S et button for which see chapter
Enrolling the detectors. In
this case if us ed with JA-100 system it is recommended to use the internal menu for a final ch eck of the activation modes of enrolled detectors.
The relay internal settings do not work in online mode. That´s why it is not possible to enroll devices via F-Link SW by only inserting batteries. It is only possible by entering the serial number and saving the settings.
Mode: This option determines how the relay will react to the activation of an enrolled detector.
- None: the detector has no function
- Extended copy: if the associated status-mode detector has
the copy function alread y s et, the relay will be switched ON for as lon g as the detector is activated. If the common timer has been previously pre-set, the relay switches off with this pre-set delay after detector deactivation.
- Impulse: detector activation will switch ON the relay for a pre-
defined time given by the Common timer
- Change st atus: detector activation changes the relay status
- Always switching off: detector activation always switches off
the relay
- Block: A particular active status-mode detector blocks
switching the relay by other detectors for its whole activation period. If this status-mode det ector goes to standby the Common timer is no longer effective. W hen blocking is over, the relay is activated again if any status-mode detect or is activated. The bl ocking is indicated by th e green LED flashing, blocking dur ing other detector activation is indicated by alternate flashing in green / red of the RELAY LED.
Stand-alone mode
Up to 64 one-way communicating detectors of the JA-15x series can be enrolled to the relay. Enrollment and s etup of the detectors is performed by the Learn/Set button (1). The relay can recognize 3 pressing lengths:
Short press < 3 s Turns the relay ON or scrolls the
menu
Long press > 3 s < 6 s Enters the menu or sen ds an
enrollment signal
Very lon g press 6 s Exits the menu or c onfirms the timer
Page 2
The AC-160-C Wireless multifunctional relay
The AC-160-C wireless multipurpose relay 2 / 2 MLZ54600
Enrolling the detectors
First of all s elect the mode in which the detector should be
operated and then enroll it.
Procedure:
1. Perform a long pr ess of the Learn/Set button (1) until the yellow LED starts flashing.
2. When you release the butt on the relay is ready to receive an enrolling signal from a detector, confirmed by permanent lighting of the yellow LED and a flashing r ed LED. The number of flashes determines the operation mode to which the detector will be enrolled. Operation mode selection is performed by repeatedly briefly pressing the button.
No. of red LED flashes. Mode 1x * * * * Copy (extended) 2x ** ** ** ** Impulse 3x *** *** *** Change status 4x **** **** Always switches off 5x ***** ***** Block 1x longer lit, short pause Mode for deleti ng detectors
Note: Extended copy – minimum s witching time is 1 s
3. Insert the batteries into the detector – it s ends an enrollment signal.
4. Enrolling is conf irmed by alternate flashing of the LED in r ed and green.
5. When the enrollment procedur e has been done correctly, the relay goes back to its normal operatin g mode – the green LED is ON. This means that if you want to enroll the next detector you must repeat the whole enrollment procedure.
Erasing the detectors
1. Perform a long pr ess of the Learn/Set button (1) until the yellow LED starts fl ashing. Now releas e th e button and the yellow LED indicates permanently and the red LED flashes.
2. By repeated pressing (5x) of the button (1) select the mode when th e red LED lights constant ly with a regular short pause.
3. Insert the batteries into the detector which is to be erased.
4. Erasing the detect or from the relay is confirmed by alternat e flashing of the red / green LED indicators.
5. When the erasing procedure has been done, the relay goes back to its normal operating mode.
Common timer setup
1. Perform a long pr ess of the Learn/Set button (1) until the yellow LED starts fl ashing. Now releas e th e button and the yellow LED indicates permanently and the red LED flashes.
2. Perform a long pr ess of the Learn/S et button (1) again until the flashing of the red LED changes to permanent lighting of the green LED.
3. When the button is releas ed the green LED will flash. The number of flashes determines the pre-set period of the Common timer.
4. By repeat ed pressing of the button (1) s elect the required time of the common timer. Table shows 5 default options. Those values can not be changed in stand- alone mode. When it is pre-set by F-Link to a different time than is mentioned (not to predefined/default values), the green LED lights with a regular short pause.
No. of green LED flashes. Timer period 1x * * * * 1 s (default) 2x ** ** ** ** 1 min 3x *** *** *** 3 min 4x **** **** 15 min 5x ***** ***** 30 min 1x longer lit, short pause Different settings (via F-Link)
5. Confirm the selected val ue by very long pressing (more than 6 s) unti l the red/gr een LED indicators start flashing. Settings are s aved.
Note: no activity for longer than 1 minut e terminates th e setup/enrollment mod e, saves the changes and goes to n ormal operating mode. To leave the setting/enrollment mode, press the Learn/S et button (1) for a very long time (more than 6 s) – a red/gr een LED indic ator flashes briefly and the relay goes to its normal operating mode.
Operational status - optical indication
LED indication Mode
ERR
(yellow)
OFF Everything OK
ON
(stand-alone mode)
Setting
ON
(operation wit h
control panel)
Loss of
communication
or
Internal s ettings
entered
Flashes 1/s
Low Battery from
detector(s)
RELAY
(red/green)
RED LED ON Relay ON
GREEN LED ON Relay OFF
GREEN flashes Blocking when OFF
GREEN/RED
flashes
Blocking when ON
Reseting the relay
A full relay reset and complet e erasing of all enr olled devices is performed by very long pressing (more than 6 s) of the button (1). It is indicated by alternate flashing in red/green of the RELA Y LED simultaneousl y with permanent lit of the ERR LED. The Learn/Set button must be then releas ed (within 3 s) and then shortly pressed again (also within 3 s). The relay reset is confirmed by quick alternate flashing in red/gr een of the RELA Y LED with a yellow ERR LED. After this only the green and yellow LED stays lit. A reset doesn´t erase an enrolled control panel currently in service mode (in this c ase the yellow LED will not be lit).
Technical specifications
Operational power 100-230 V / 50-60 Hz Own power consumption f or 230 V AC ( min / max)
0.2 W / 0.7 W
Communication band 868.1 MH z, J ablotr on protocol Antenna Internal Contact rating - protection class II:
Maximum switching voltage 250 V AC Resistive load FRVij  max.16 A Inductive, capacitive load FRVij  max. 8 A Halogen lights max. 1000 W
Minimum switching DC power 0.5 W Recommended c onnection wires: max. 2 x 1.5 mm
2
; max. 1 x 2.5 mm2 IP cover ing IP-20 (according to EN 60529), IP-40 ( with a front panel) Dimensions 49 x 49 x 26 mm Weight 65 g Operational temperat ure r ange
-10 to + 40°C, relative humidity 75% no condensation Complies with ETSI EN 300 220-1, EN 50130-4 EN 55022, EN 60950- 1 Can be operated to ERC REC 70-03
The AC-160-C complies with the essential requirements of: Directive 1999/5/EC, 2012/65/EU, when used for its intended purpose. The ori ginal of the conformity assessment can be found at
www.jablotron.com, Technical Support secti on.
Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use.