© 2000 IXYS All rights reserved
1 - 2
V
RSM
V
RRM
Type
V
DSM
V
DRM
VV
700 600 VWO 35-06ho7
900 800 VWO 35-08ho7
1300 1200 VWO 35-12ho7
I
RMS
= 3x 35 A
V
RRM
= 600-1200 V
Features
●
Thyristor controller for AC (circuit
W3C acc. to IEC) for mains frequency
●
Soldering connections for PCB
mounting
●
Isolation voltage 3000 V~
●
Planar passivated chips
Applications
●
Switching and control of
three phase AC circuits
●
Softstart AC motor controller
●
Solid state switches
●
Light and temperature control
Advantages
●
Easy to mount with two screws
●
Space and weight savings
●
Improved temperature and power
cycling
030
VWO 35
Data according to IEC 60747 refer to a single thyristor/diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions
AC Controller Modules
Symbol Test Conditions Maximum Ratings
I
RMS
TC = 85°C, (per phase) 35 A
I
TAVM
TC = 85°C; (180° sine ; per thyristor) 16 A
I
TSM
TVJ = 45°C; t = 10 ms (50 Hz), sine 200 A
VR = 0 t = 8.3 ms (60 Hz), sine 210 A
TVJ = T
VJM
t = 10 ms (50 Hz), sine 180 A
VR = 0 t = 8.3 ms (60 Hz), sine 190 A
I2t TVJ = 45°C t = 10 ms (50 Hz), sine 200 A2s
VR = 0 t = 8.3 ms (60 Hz), sine 150 A2s
T
VJ
= T
VJM
t = 10 ms (50 Hz), sine 160 A2s
VR = 0 t = 8.3 ms (60 Hz), sine 150 A2s
(di/dt)
cr
TVJ = T
VJM
repetitive, IT = 20 A 100 A/ms
f =50 Hz, tP =200 ms
VD = 2/3 V
DRM
IG = 0.15 A non repetitive, IT = I
TAVM
500 A/ms
diG/dt = 0.15 A/ms
(dv/dt)
cr
TVJ = T
VJM
;V
DR
= 2/3 V
DRM
500 V/ms
RGK = ¥; method 1 (linear voltage rise)
V
RGM
10 V
P
GM
TVJ = T
VJM
tp = 30 ms £ 5W
IT = I
TAVM
tp = 300 ms £ 2.5 W
P
GAVM
0.5 W
T
VJ
-40...+125 °C
T
VJM
125 °C
T
stg
-40...+125 °C
V
ISOL
50/60 Hz, RMS t = 1 min 2500 V~
I
ISOL
£ 1 mA t = 1 s 3000 V~
M
d
Mounting torque (M4) 1.5 - 2 Nm
14 - 18 lb.in.
Weight typ. 18 g
BA EC GF
IH LJ NM
Preliminary data