IXYS VUO82-18NO7, VUO82-16NO7, VUO82-14NO7, VUO82-12NO7, VUO82-08NO7 Datasheet

...
VUO 62 VUO 82
Three Phase Rectifier Bridge
RSM
VV
600 600 VUO 62-06NO7 VUO 82-06NO7 800 800 VUO 62-08NO7 VUO 82-08NO7 1200 1200 VUO 62-12NO7 VUO 82-12NO7 1400 1400 VUO 62-14NO7 VUO 82-14NO7 1600 1600 VUO 62-16NO7 VUO 82-16NO7 1800 1800 VUO 62-18NO7* VUO 82-18NO7*
Symbol Test Conditions Maximum Ratings
I
dAV
I
dAV
I
FSM
I2t TVJ = 45°C t = 10 ms (50 Hz), sine 1520 2800 A2s
T
VJ
T
VJM
T
stg
ISOL
M
d
Weight typ. 160 g Symbol Test Conditions Characteristic Values
I
R
F
T0
r
T
R
thJC
R
thJH
d
S
d
A
a Max. allowable acceleration 50 m/s
Data according to IEC 60747 and refer to a single diode unless otherwise stated. IXYS reserves the right to change limits, test conditions and dimensions.
© 2000 IXYS All rights reserved
RRM
Type
~ ~ ~
* delivery time on request
VUO 62 VUO 82
TC = 110°C, module 63 88 A TA = 45°C (R
= 0.6 K/W), module 48 57 A
thCA
TVJ = 45°C; t = 10 ms (50 Hz), sine 550 750 A VR = 0 t = 8.3 ms (60 Hz), sine 600 820 A
TVJ = T VR = 0 t = 8.3 ms (60 Hz), sine 550 740 A
t = 10 ms (50 Hz), sine 500 670 A
VJM
VR = 0 t = 8.3 ms (60 Hz), sine 1520 2800 A2s TVJ = T
VJM
VR = 0 t = 8.3 ms (60 Hz), sine 1250 2250 A2s
t = 10 ms (50 Hz), sine 1250 2250 A2s
-40...+150 °C 150 °C
-40...+125 °C
50/60 Hz, RMS t = 1 min 2500 V~
£ 1 mA t = 1 s 3000 V~
I
ISOL
Mounting torque (M5) 5 ± 15 % Nm Terminal connection torque (M5) 5 ± 15 % Nm
VUO 62 VUO 82
VR= V VR= V
RRM;TVJ RRM;TVJ
= 25°C £ 0.3 0.3 mA = T
VJM
£ 55mA IF= 150 A; TVJ = 25°C £ 1.8 1.6 V For power-loss calculations only 0.8 0.8 V
85mW
per diode 1.45 1.1 K/W per module 0.24 0.183 K/W
per diode 1.87 1.52 K/W per module 0.31 0.253 K/W
Creeping distance on surface 10 mm Creepage distance in air 9.4 mm
I
dA V
V
+
= 63/88 A = 800-1800 V
RRM
~
~
~
+
Features
Package with screw terminals
Isolation voltage 3000 V~
Planar passivated chips
Blocking voltage up to 1800 V
Low forward voltage drop
UL registered E72873
Applications
Supplies for DC power equipment
Input rectifiers for PWM inverter
Battery DC power supplies
Field supply for DC motors
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling
Dimensions in mm (1 mm = 0.0394")
2.5
72 60 54
20
2.5
~
5.3
21.6
2
+
20
18
~
10
23 48
-
M5x10
7
30
3
2.5
~
5.3
13.3
1 - 1
42
Loading...