THE PULSE OF THE FUTURE
Directed Energy, Inc.
An IXYS Company
2401 Research Blvd., Suite 108
Fort Collins, CO USA 80526
970-493-1901 Fax: 970-493-1903
Email: deiinfo@directedenergy.com
Web: http://www.directedenergy.com
SPECIFICATIONS
(All specifications measured into a 5Ω load connected with 4 feet (~1.2M) 5Ω cable provided with the PVX-2110)
Doc #9200-0216 Rev 3
© Directed Energy, Inc. 2000
OUTPUT
Output Voltage Polarit y Positive Or Negative, Factory Configured
Maximum Value 200 Volts
Minimum Value 0 Volts
Means Of Adjustment Controlled By Power Supply Input Voltage
Maximum Output Current 50A Peak, 25A Average
(1)
Pulse Rise And Fall Time <100ns (10% to 90%)
Pulse Width <200ns to 2ms, Controlled by Input Gate
Pulse Recurrence Frequency
(PRF)
Single shot to 50KHz, Controlled by Input Gate
Max. Peak Output Power 10,000W
(2)
Max. Duty Cycle 50%
Droop (At 50A Output Current) <5% @ 1ms pulse width, <10% @ 2ms pulse width
Over/undershoot <5%
Jitter <10ns shot-to-shot
Output Connector & Cable
Type N, With 4 feet (~1.2M) 5Ω Coaxial Cable
INPUT DC VOLTAGE
Input Voltage Polarity Positive Or Negative (User-supplied)
(4)
Maximum Value 200 Volts
Minimum Value 0 Volts
Maximum Input Power 5,000W
Input DC Connector Type N, Rear Panel
GATE
Gate Source
+5V ±1V into 50Ω
Input Gate Connector BNC, Front Panel
VOLTAGE & CURRENT MONITORS
Voltage Monitor
50:1 into 50Ω, accuracy typically within 3% of the
actual output voltage
Voltage Monitor Connector BNC, Front Panel
Current Monitor
10A/V into 50Ω, accuracy typically within 3% of the
actual output current
Current Monitor Connector BNC, Front Panel
GENERAL
Support Power 90VAC to 240VAC, 50/60Hz
Dimensions (Excluding Connec-
tors)
19” W x 5.2” H x 16” D (48.25cm W x 13.2cm H x
41cm D)
Weight (Approximate) 18 lbs. (8.2 Kilograms)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Max. Average Output Power 5,000W
(3)
200ns Minimum Pulse Width, 200V Output
(100ns/Div horizontal scale, 50V/ Div vertical scale)
<50ns Rise Time, 200V Output
(25ns/Div horizontal scale, 50V/Div vert ical scale)
Typical Output Waveform, 200V
(10µs/Div horizontal scale, 50V/Div vert ical scale)
50KHz, 50% Duty Cycle, 200V Output
(8ΩΩΩΩ Load, 10µs/Div horizontal scale, 50V/Div verti cal scal e)
(1) When driving loads with impedances <5Ω, the output voltage must be limited to <200V,
so that the peak output current (V/R) does not exceed 50A, and the maximum average
current (defined as I x Duty Cycle) does not exceed 25A.
(2) Peak output power is defined as V x I during the output pulse.
(3) Average output power is defined as V x I x Duty Cycle.
(4) Input DC power supply must be the same polarity as the PVX-2110 (i.e. a positive output
PVX-2110 requires a positive high voltage DC input).