IXYS PVX-2110 Datasheet

THE PULSE OF THE FUTURE
DIRECTED ENERGY INCORPORATED
PVX-2110
200V 50A PULSE GENERATOR
10kW Peak Output Power
<100ns Rise And Fall Times
<200ns to 2ms Pulse Width
0 to 50KHz Pulse Repetition Frequency
Protected Against Arcs, Shorts And
Load Transients
Integral Voltage And Current Monitor
Outputs
Optimized To Drive Loads From 1ΩΩΩΩ to 25ΩΩΩ
The PVX-2110 high power pulse generator (pulsed volt­age source) is designed for pulsing low impedance loads (from 1 to 25Ω) at up to 200V and 50A, with pulse widths from 200ns to 2ms
. The exceptional pulse fidelity of the
PVX-2110 will optimize the performance of any system in which it is used.
The PVX-2110 can deliver up to 10kW of peak output power and 5kW of average output power, making it well suited for use in materials testing and processing, semi­conductor testing and characterization, and other test and measurement and R&D applications.
The PVX-2110 requires a TTL gate signal and high volt­age DC power supply inputs. The output pulse width and frequency are controlled by the gate signal. The pulse out­put voltage is controlled by the amplitude of the input DC power supply.
The PVX-2110 features front panel indicator LEDs to monitor the status of the pulse generator. Front panel volt­age and current monitors provide a straightforward means to view the output voltage and current waveforms in real­time, eliminating the need for an external high voltage os­cilloscope probe.
The output cable supplied with the unit is an inn ovati v e custom designed multi-coaxial cable with an impedance of
5Ω. The design of this cable maintains the fidelity of the output pulse without introducing pulse distortion or ringing, and provides a convenient means of connecting the pulse generator to the load.
The PVX-2110 has over-current detection and shut-down circuitry to protect the pulse generator from potential dam­age due to over-current conditions such as arcs and shorts in the load or interconnect cable. If an over-current condi­tion is detected, the output pulse is truncated for 10 milli­seconds. The pulse generator then automatically re­enables the output, and will continue pulsing, unless the over-current condition persists. It is also protected against operation at excessive pulse widths or frequencies.
The pulse generator is a direct-coupled, air-cooled solid­state design, offering fast pulse rise and fall times, low power dissipation, and virtually no over-shoot, under-shoot or ringing. All control and protection logic circuitry, support power, energy storage and output network are incorporated into the PVX-2110. It is connected directly to the load, and does not require series or shunt resistors, impedance­matching networks between the pulse generator and the load, or additional energy storage (capacitor banks). All of this is taken care of within the PVX-2110.
THE PULSE OF THE FUTURE
Directed Energy, Inc. An IXYS Company 2401 Research Blvd., Suite 108 Fort Collins, CO USA 80526 970-493-1901 Fax: 970-493-1903 Email: deiinfo@directedenergy.com Web: http://www.directedenergy.com
SPECIFICATIONS
(All specifications measured into a 5 load connected with 4 feet (~1.2M) 5 cable provided with the PVX-2110)
Doc #9200-0216 Rev 3 © Directed Energy, Inc. 2000
OUTPUT
Output Voltage Polarit y Positive Or Negative, Factory Configured Maximum Value 200 Volts Minimum Value 0 Volts Means Of Adjustment Controlled By Power Supply Input Voltage Maximum Output Current 50A Peak, 25A Average
(1)
Pulse Rise And Fall Time <100ns (10% to 90%) Pulse Width <200ns to 2ms, Controlled by Input Gate Pulse Recurrence Frequency
(PRF)
Single shot to 50KHz, Controlled by Input Gate
Max. Peak Output Power 10,000W
(2)
Max. Duty Cycle 50% Droop (At 50A Output Current) <5% @ 1ms pulse width, <10% @ 2ms pulse width Over/undershoot <5% Jitter <10ns shot-to-shot Output Connector & Cable
Type N, With 4 feet (~1.2M) 5Coaxial Cable
INPUT DC VOLTAGE
Input Voltage Polarity Positive Or Negative (User-supplied)
(4)
Maximum Value 200 Volts Minimum Value 0 Volts Maximum Input Power 5,000W Input DC Connector Type N, Rear Panel
GATE
Gate Source
+5V ±1V into 50
Input Gate Connector BNC, Front Panel
VOLTAGE & CURRENT MONITORS
Voltage Monitor
50:1 into 50, accuracy typically within 3% of the actual output voltage
Voltage Monitor Connector BNC, Front Panel Current Monitor
10A/V into 50, accuracy typically within 3% of the actual output current
Current Monitor Connector BNC, Front Panel
GENERAL
Support Power 90VAC to 240VAC, 50/60Hz Dimensions (Excluding Connec-
tors)
19” W x 5.2” H x 16” D (48.25cm W x 13.2cm H x 41cm D)
Weight (Approximate) 18 lbs. (8.2 Kilograms)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Max. Average Output Power 5,000W
(3)
200ns Minimum Pulse Width, 200V Output
(100ns/Div horizontal scale, 50V/ Div vertical scale)
<50ns Rise Time, 200V Output
(25ns/Div horizontal scale, 50V/Div vert ical scale)
Typical Output Waveform, 200V
(10µs/Div horizontal scale, 50V/Div vert ical scale)
50KHz, 50% Duty Cycle, 200V Output
(8ΩΩΩ Load, 10µs/Div horizontal scale, 50V/Div verti cal scal e)
(1) When driving loads with impedances <5, the output voltage must be limited to <200V,
so that the peak output current (V/R) does not exceed 50A, and the maximum average
current (defined as I x Duty Cycle) does not exceed 25A. (2) Peak output power is defined as V x I during the output pulse. (3) Average output power is defined as V x I x Duty Cycle. (4) Input DC power supply must be the same polarity as the PVX-2110 (i.e. a positive output
PVX-2110 requires a positive high voltage DC input).
Loading...