IXYS MEK95-06DA, MEE95-06DA, MEA95-06DA Datasheet

Fast Recovery Epitaxial Diode (FRED) Module
MEA 95-06 DA MEK 95-06 DA
MEE 95-06 DA
V I t
RRM
FAV
rr
= 600 V = 95 A = 250 ns
V
RSM
V
RRM
Type
V V MEA95-06 DA MEK 95-06 DA MEE 95-06 DA
600 600
123 123 123
Symbol Test Conditions Maximum Ratings I
FRMS
I
ÿÿ
T
FAV
I
FRM
I
FSM
I2t TVJ = 45°C; t = 10 ms (50 Hz), sine A2s
T
VJ
T
stg
T
Hmax
P
tot
V
ISOL
M
d
d
S
d
A
a Maximum allowable acceleration m/s Weight g
T
= °CA
75 142
case
= °C; rectangular, d = 0.5 A
75 95
case
tP < 10 ms; rep. rating, pulse width limited by T
VJM
TVJ = 45°C; t = 10 ms (50 Hz), sine A
t = 8.3 ms(60 Hz), sine A
TVJ = 150°C; t = 10 ms (50 Hz), sine A
t = 8.3 ms(60 Hz), sine A
TBD
1200 1300
1080 1170
A
7200
t = 8.3 ms(60 Hz), sine A2s
TVJ = 150°C; t = 10 ms (50 Hz), sine A2s
t = 8.3 ms(60 Hz), sine A2s
T
= 25°CW
case
50/60 Hz, RMS t = 1 min V~ I
£ 1 mA t = 1 s V~
ISOL
Mounting torque (M5) Nm/lb.in. Terminal connection torque (M5) Nm/lb.in.
Creep distance on surface mm Strike distance through air mm
7100 5800
5700
-40...+150
-40...+125 110
280
3000 3600
2.5-4/22-35
2.5-4/22-35
12.7
9.6
°C °C °C
50 90
Symbol Test Conditions Characteristic Values (per diode)
typ. max.
I
R
V
F
TVJ = 25°CVR= V TVJ = 25°CVR= 0.8 • V TVJ = 125°CVR= 0.8 • V
IF = A; TVJ=125°CV
100 1.36
RRM
RRM RRM
TVJ=25°CV
IF = A; TVJ=125°CV
300 2.05
TVJ=25°CV
V
T0
r
T
R
thJH
R
thJC
t
rr
I
RM
For power-loss calculations only V T
= 125°C mW
VJ
DC current K/W DC current K/W
I
=A TVJ = 100°Cns
100 250 300
F
VR=V TVJ = 25°CA
300 14
-di/dt = A/msTVJ = 100°CA
200 21
0.5 34
1.55
2.09
1.01
2.85
0.550
0.450
2
mA mA mA
TO-240 AA
3
2
1
Features
International standard package with DCB ceramic base plate
Planar passivated chips
Short recovery time
Low switching losses
Soft recovery behaviour
Isolation voltage 3600 V~
UL registered E 72873
Applications
Antiparallel diode for high frequency switching devices
Free wheeling diode in converters and motor control circuits
Inductive heating and melting
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
Advantages
2
High reliability circuit operation
Low voltage peaks for reduced protection circuits
Low noise switching
Low losses
I
rating includes reverse blocking losses at T
FAV
Data according to IEC 60747 IXYS reserves the right to change limits, test conditions and dimensions
, VR = 0.6 V
VJM
, duty cycle d = 0.5
RRM
© 2000 IXYS All rights reserved
749
1 - 2
MEA 95-06 DA MEE 95-06 DA
MEK 95-06 DA
200
A
175 150
I
F
125
TVJ=150°C
100
TVJ=100°C TVJ=25°C
75 50 25
0
0.00.51.01.52.0 V
F
Fig. 1 Forward current IF versus
voltage drop VF per leg
2.0
1.5
K
f
1.0
Q
r
Q
r
4
µC
3
2
TVJ= 100°C VR = 300V
IF=190A IF= 95A
I
RM
60
TVJ= 100°C
A
VR = 300V
50
40
30
IF=190A IF= 95A IF=47.5A
IF=47.5A
20
1
10
V
10 100 1000
A/ms
-diF/dt
0
Fig. 2 Reverse recovery charge Q
versus -diF/dt
250
ns
t
200
rr
TVJ= 100°C VR = 300V
r
IF=190A IF= 95A
I
RM
150
IF=47.5A
0
200 600 10000 400 800
-di
Fig. 3 Peak reverse current I
versus -diF/dt
50
TVJ= 100°C
A
IF = 150A
40
V
FR
30
20
t
fr
F
/dt
A/ms
RM
1.0 µs
V
FR
0.8
t
fr
0.6
0.4
0.5
0.0 0 50 100 150
T
VJ
Fig. 4 Dynamic parameters Qr, I
versus junction temperature T
°C
RM
VJ
100
50
200 600 10000 400 800
/dt
-di
F
Fig. 5 Recovery time trr versus -diF/dt Fig. 6 Peak forward voltage VFR and t
0.6
K/W
0.5
0.4
Z
thJH
0.3
0.2
0.1
0.0
0.001 0.01 0.1 1 10
s
Fig. 7 Transient thermal impedance junction to heatsink
t
A/ms
10
0
0 200 400 600 800 1000
diF/dt
versus diF/dt
Constants for Z
iR
calculation:
thJH
(K/W) ti (s)
thi
1 0.037 0.002 2 0.138 0.134 3 0.093 0.25 4 0.282 0.274
0.2
0.0
A/ms
fr
© 2000 IXYS All rights reserved
2 - 2