Fast Recovery
Epitaxial Diode (FRED)
DSEI 8
I
FAVM
V
RRM
t
rr
=8 A
= 600 V
= 35 ns
V
RSM
V
RRM
Type
A
C
TO-263 AA
DSEI 8-06AS
V V
640 600 DSEI 8-06A
640 600 DSEI 8-06AS
Symbol Test Conditions Maximum Ratings
I
FRMS
I
ÿÿ
① TC = 115°C; rectangular, d = 0.5 8 A
FAVM
I
FRM
I
FSM
TVJ = T
VJM
tP < 10 ms; rep. rating, pulse width limited by T
VJM
16 A
130 A
TVJ = 45°C; t = 10 ms (50 Hz), sine 100 A
t = 8.3 ms(60 Hz), sine 110 A
TO-220 AC
DSEI 8-06A
A = Anode, C = Cathode, NC = No connection
TAB = Cathode
TVJ = 150°C; t = 10 ms (50 Hz), sine 85 A
t = 8.3 ms(60 Hz), sine 95 A
I2t TVJ = 45°C t = 10 ms (50 Hz), sine 50 A2s
t = 8.3 ms(60 Hz), sine 50 A2s
TVJ = 150°C; t = 10 ms (50 Hz), sine 36 A2s
Features
●
t = 8.3 ms(60 Hz), sine 37 A2s
T
VJ
T
VJM
T
stg
P
tot
M
d
TC = 25°C50W
Mounting torque 0.4...0.6 Nm
-40...+150 °C
150 °C
-40...+150 °C
Weight 2g
Symbol Test Conditions Characteristic Values
typ. max.
I
R
V
F
V
T0
r
T
R
thJC
R
thCK
R
thJA
t
rr
I
RM
TVJ = 25°CVR= V
TVJ = 25°CVR= 0.8 • V
RRM
TVJ = 125°CVR= 0.8 • V
RRM
RRM
20 mA
10 mA
1.5 mA
IF = 8 A; TVJ=150°C 1.3 V
TVJ=25°C 1.5 V
For power-loss calculations only 0.98 V
TVJ = T
VJM
28.7 mW
2.5 K/W
0.5 K/W
60 K/W
IF = 1 A; -di/dt = 50 A/ms; VR = 30 V; TVJ = 25°C35 50 ns
VR = 350 V; IF = 8 A; -diF/dt = 64 A/ms 2.5 2.8 A
L £ 0.05 mH; TVJ = 100°C
●
●
●
●
●
●
Applications
●
●
●
●
●
●
●
●
Advantages
●
●
●
●
●
NC
A
C
A
C (TAB)
C
International standard package
JEDEC TO-220 AC & TO-263 AB
Planar passivated chips
Very short recovery time
Extremely low switching losses
Low IRM-values
Soft recovery behaviour
Epoxy meets UL 94V-0
Antiparallel diode for high frequency
switching devices
Anti saturation diode
Snubber diode
Free wheeling diode in converters
and motor control circuits
Rectifiers in switch mode power
supplies (SMPS)
Inductive heating and melting
Uninterruptible power supplies (UPS)
Ultrasonic cleaners and welders
High reliability circuit operation
Low voltage peaks for reduced
protection circuits
Low noise switching
Low losses
Operating at lower temperature or
space saving by reduced cooling
① I
rating includes reverse blocking losses at T
FAVM
Data according to IEC 60747
IXYS reserves the right to change limits, test conditions and dimensions
, VR = 0.8 V
VJM
, duty cycle d = 0.5
RRM
© 2000 IXYS All rights reserved
033
1 - 2
DSEI 8, 600 V
Fig. 1 Forward current Fig. 2 Recovery charge versus -diF/dt. Fig. 3 Peak reverse current versus
versus voltage drop. -diF/dt.
Fig. 4 Dynamic parameters versus Fig. 5 Recovery time versus -diF/dt. Fig. 6 Peak forward voltage
junction temperature. versus diF/dt.
Dimensions TO-220 AC
Dim. Millimeter Inches
Min. Max. Min. Max.
A 12.70 14.73 0.500 0.580
B 14.23 16.51 0.560 0.650
C 9.66 10.66 0.380 0.420
D 3.54 4.08 0.139 0.161
E 5.85 6.85 0.230 0.420
F 2.54 3.42 0.100 0.135
G 1.15 1.77 0.045 0.070
H - 6.35 - 0.250
J 0.64 0.89 0.025 0.035
K 4.83 5.33 0.190 0.210
L 3.56 4.82 0.140 0.190
M 0.38 0.56 0.015 0.022
N 2.04 2.49 0.080 0.115
Q 0.64 1.39 0.025 0.055
Fig. 7 Transient thermal impedance junction to case.
Dimension TO-263 AA see DSEI 19
© 2000 IXYS All rights reserved
033