![](/html/20/20ad/20ad0a0d7ab45da285e4b8f7aa00d07bdb4fbc1bb7d8950d3b9659fb4e7baeee/bg1.png)
STARTUP GUIDE
CANblue II
Firmware Update
Dependent on the product version of the CANblue II different firmware versions must be used:
• For CANblue II devices with product versions 1.x use firmware version V2.00.xx.
• For CANblue II devices with product versions 2.x use firmware version V2.01.xx.
The product version is printed on the label on the back of the device.
For product versions 1.x:
► Contact Ixxat support for update files.
For product versions 2.0 and higher:
► Download the latest update files from support area on www.ixxat.com.
► Restore the CANblue II to factory settings (see User Manual CANblue II for further information).
► Make sure that the CANblueCon configuration tool is closed.
► Install a virtual Config COM port (see User Manual CANblue II for further information).
► Open Command Prompt (cmd.exe) and navigate to the folder FW Update in the folder of the downloaded
update files.
► Call FW-Update <COM-PORT> with the COM port in use (e.g. FW-Update 5).
→ New firmware version and firmware version of the CANblue II are displayed.
→ Firmware is updated.
→ When the update is completed, the CANblue II automatically restarts.
→ LED CAN and LED Mode are flashing red and green during the restart.
► To check the firmware version enter command D VERSION in the CANblueCon configuration tool.
© 2020 HMS Industrial Networks
4.01.0126.20001 1.2 en-US / 2020-06-02 / 18777