Technical Specifications and
Instructions
PNEUMATIC MAGNET IXTUR MRP-46
Original User Manual
Ixtur Ltd / MRP-46
1
Content
Introduction and Warnings .............................................................................................................. 2
Technical Specifications .................................................................................................................. 3
Holding Force ................................................................................................................................. 4
Installing the Device ........................................................................................................................ 7
Using the Ixtur MRP-46 Pneumatic Magnet .................................................................................... 8
Maintenance and Inspections ......................................................................................................... 9
Warranty ......................................................................................................................................... 9
Patent Pending ............................................................................................................................. 10
Declaration of Conformity .............................................................................................................. 10
Ixtur Ltd / MRP-46
2
Introduction and Warnings
MRP-46 is a pneumatic magnet meant for attaching ferromagnetic parts in lifting, work holding or automation applications. It is suitable for plates and round objects. The magnets state, attached or detached, is changed pneumatically. MRP-46 pneumatic magnet doesn’t need compressed air to keep its state. Air pressure is needed only to change the state from attached to detached or vice versa.
Please read this manual carefully before deployment to ensure safe use of the device.
This device includes a source of magnetic field. A fluctuating magnetic field is produced
during the use in the proximity of the device.
This device produces a magnetic field that may interfere with medical devices such as
metallic implants or cardiac pacemakers. Do not use this device and keep out of close proximity unless you have approval from the manufacturer of the medical device or from
your physician.
Do not disassemble or replace the parts of the device. Only pneumatic connectors are user
changeable.
The device must not be used for lifting or transporting people. The permitted holding force must not be exceeded.Always pay special attention to the factors that may decrease the holding force of the
magnet.
Do not operate a damaged or malfunctioning device. The designer and manufacturer of the system, which this device will be integrated into,
should always ensure that the complete system meets the local and national safety
regulations.
Ixtur Ltd / MRP-46
3
Technical Specifications
Dimensions:
- Length: 80.0 mm
- Width 54.8 mm
- Height: 82.5 mm
- Weight: 1860 g
Capacity:
- Rated holding force: 1354 N (S355 S 12 mm plate)
- Rated holding force: 883 N (S355 cylinder ø ≥ 120 mm)
- Rated lifting capacity for plate with safety factor 3: 46 kg (S355 S 12 mm)
- Rated lifting capacity for solid round object with safety factor 3: 30 kg (ø ≥ 120 mm)
- Residual holding force flat: maximum 1200 g
- Residual holding force for other shapes:
MRP-46’s magnetic structure (similar to standard lever magnets) makes residual grip- ping capacity sensitive to material and geometry of the lifted part. In extreme case, a part up to 4 kg may stay connected to the magnet. This may happen just after the mag­net has been turned OFF. When this behavior is critical to the application, the actual parts need to be pretested with the MRP-46 magnet.
Environmental conditions:
- Operating temperature: 0 °C … +50 °C
- Storage temperature: -20 °C … +50 °C
- Humidity 0 % … 90 %
- IP67 (The device is protected from dust and temporary immersion up to 1 m)
Requirements for compressed air:
- Recommended pressure: 6.0 bar
- Functional range: 5.0 … 8.0 bar
- Water separation
- Particle filter ≤ 5µm
Information related to medical implants
- Safety distance for a person with active implanted device is 50 cm of air or other non­magnetic material. The distance is measured from the magnet or magnetic material attached to it.
o Maximum static magnetic field of MRP-46 is 200 mT on the gripping surface. o Interference with active implanted devices, e.g. cardiac pacemakers – Action level for expo-
sure to static magnetic fields is 0,5 mT [Directive 2013/35/EC].