ixtur MRP-20NK Technical Specifications And Instructions

13.11.2018
Technical Specifications and
Instructions
PNEUMATIC MAGNET IXTUR MRP-20NK
Original User Manual
IXTUR OY | VARESPELLONTIE 6, FI-21500 KAARINA FINLAND, WWW.IXTUR.COM
1
Content
Introduction and Warnings ............................................................................................................................ 2
Technical Specifications ................................................................................................................................ 3
Holding Force .................................................................................................................................................. 4
Installing the Device ....................................................................................................................................... 7
Using the Ixtur MRP-20NK Pneumatic Magnet .......................................................................................... 8
Maintenance and Inspections ....................................................................................................................... 9
Warranty ........................................................................................................................................................... 9
Patent Pending ................................................................................................................................................ 9
Declaration of Conformity .............................................................................................................................. 9
Ixtur Ltd / MRP-20NK
2
Introduction and Warnings
MRP-20NK is a pneumatic magnet meant for gripping ferromagnetic parts in lifting, work holding or automation applications. It is suitable for plates and round objects. The magnet’s state, attached or detached, is changed pneumatically. MRP-20NK pneumatic magnet doesn’t need compressed air to keep its state. Air pressure is needed only to change the state from attached to detached or vice versa.
Please read this manual carefully before deployment to ensure safe use of the device.
This device includes a source of magnetic field. A fluctuating magnetic field is produced
during the use in the proximity of the device.
This device produces a magnetic field that may interfere with medical devices such as
metallic implants or cardiac pacemakers. Do not use this device and keep out of close proximity unless you have approval from the manufacturer of the medical device or from
your physician.
Do not disassemble or replace the parts of the device. Only pneumatic connectors are user changeable.
The device must not be used for lifting or transporting people.
The permitted holding force must not be exceeded.
Always pay special attention to the factors that may decrease the holding force of the
magnet.
Do not operate a damaged or malfunctioning device.
The designer and manufacturer of the system, which this device will be integrated into,
should always ensure that the complete system meets the local and national safety
regulations.
Ixtur Ltd / MRP-20NK
3
Technical Specifications
Dimensions:
- Length: 80.0 mm
- Width 54.8 mm
- Height: 114.0 mm
- Weight: 2.4 kg
Capacity:
- Rated holding force: 590 N (S355 S 4 mm plate)
- Rated holding force: 380 N (S355 cylinder ø 14 mm)
- Rated lifting capacity for plate with safety factor 3: 20 kg (S355 S 4 mm)
- Rated lifting capacity for solid round object with safety factor 3: 13 kg (ø 14 mm)
- Residual holding capacity: 0.1 kg
The residual gripping capacity, i.e. the gripping capacity when the magnet is OFF, varies based on the material and geometry of the gripped part. In extreme cases, parts up to 0.1 kg may stay attached. The residual capacity is greatest as long as the part continuously stays in contact with the magnet after the magnet has been turned from ON to OFF. If the amount of residual capacity is critical to the application, pretesting with the actual part is recommended.
Environmental conditions:
- Operating temperature: 0 °C … +50 °C
- Storage temperature: -20 °C … +50 °C
- Humidity 0 % … 90 %
- IP67 (The device is protected from dust and temporary immersion up to 1 m)
Requirements for compressed air:
- Recommended pressure: 6.0 bar
- Functional range: 5.0 … 8.0 bar
- Water separation
- Particle filter 5µm
Information related to medical implants
- Safety distance for a person with active implanted device is 50 cm of air or other non­magnetic material. The distance is measured from the magnet or magnetic material attached to it.
o Maximum static magnetic field of MRP-20NK is 200 mT on the gripping surface. o Interference with active implanted devices, e.g. cardiac pacemakers – Action level for expo-
sure to static magnetic fields is 0,5 mT [Directive 2013/35/EC].
Ixtur Ltd / MRP-20NK
Loading...
+ 7 hidden pages