Iwata Tornado iAC-6000, Tornado iAC-8000 Instruction Manual

INSTRUCTION MANUAL
IWATA Evaporative Air Cooler
TORNADO iAC-6000/iAC-8000
For after-sales service:
Tel. #: 442-3866, 412-6155, 413-8819, 442-3856, 448-7674
Mobile. # 0923-5345681, 0917-3079188, 0920-9746874
Email: sales_mktg@colentco.com , iwata@colentco.com
iwata2@colentco.com or iwata3@colentco.com
1
TABLE OF CONTENTS
Preface ……………………………………………………………………………
Warnings & Precautions………………………………………………………
Models Available …………………………………………………………………
Controller Panel……………………………………………………………
Technical Parameters………………………………………………………..
Preventive Maintenance……………………………………………………….
Product Application……………………………………………………………
Troubleshooting Guide………………………………………………………
2
PREFACE
Thank you for purchasing Iwata evaporative air cooler.
Please read this instruction manual prior to initial use.
Actual product may vary from the images shown in this manual due to continuous product development and may not necessarily affect the performance or reduce its functionality but rather improve it.
Please coordinate with the authorized distributor or installer prior to installing this unit.
AWarnings & Precautions
1. Use this product under the following conditions to maximize cooling effect:
①Environmental Temperature: 18℃-45℃; ②Environmental humidity:≤85%; ③Pressure:86Kpa-106Kpa ④Water supply should be clean. Water temperature≤45℃,Water pressure:0.15-0.6Mpa ⑤Please place the unit on a flat and level surface
Do not use in a confined/corrosive environment.
⑥ 2、Use a voltage stabilizer or regulator if needed. If supplied voltage is too low,
it will cause the machine to stop.
3.The controller and its wires should be positioned away from Electromagnetic
interference sources and try to avoid parallel connection to the power cord or maintain a distance longer than 30CM.
4. Air cooler must be installed in a well ventilated and dry area to ensure that fresh outdoor air will be available and is circulated into the area being cooled
5. Install exhaust fans on the area being cooled and must be away from doors and windows. 6、Do not use this air cooler in confined areas. 7、Drain all water and clean the unit when it is not going to be used for a long time to avoid damaging the cooling pads and its accessories. 8、If the power cord is damaged, have it replaced as soon as possible from the authorized service center. 9、Always unplug the unit and ensure that the power is cut off when installing or maintaining the machine. 10、Do not expose the unit to high temperature or fire. 11、Installation, maintenance and repair of the machine should be carried out by authorized professionals only 12、The equipment is not suitable for use by children, disabled or mentally challenged persons and must be operated and used with proper adult supervision. 13、Please run the air cooler for around 2-5 hours to release the smell from the
3
newly installed cooling pads.
B.Selection of model
1、Main body
TORNADO iAC-6000 TORNADO iAC-8000
INSTALLATION DIAGRAM
Choose the model & accessories that fit your requirements.
Installation will be based on final customer requirements and images shown are for reference only. Please contact the authorized distributor/contractor for details.
4
4PARTS IDENTIFICATION
5TYPE OF ACCESSORIES AVAILABLE:
5
C. CONTROL PANEL
1”SPEED” BUTTON: Adjust the fan speed (Low, Medium, High) 2、“SWINGButton: Control the swing function 3、“COOLButton: Control the water supply.
D. TECHNICAL PARAMETERS
Model TORNADO-iAC-6000 TORNADO-iAC-8000
Max airflow
Voltage 220V/60HZ 220V/60HZ
Power 400W 950W
Currency 2.2A 5.2A
Outlet size
Blower type Centrifugal-flow type Centrifugal-flow type
Water
consumption
Water tank
capacity
Overall size
Air out way TOP BLOWING TOP BLOWING
Max
Application
area
EPREVENTIVE MAINTENANCE
Filter mesh: Check and clean at least once a month to ensure smooth operation. 1、Cooling pad cleaning: remove the cooling pad and wash it under normal water pressure (do not use pressure washer as it can destroy the cooling pad). Cleaning
from the inside to the outside and the edge of the cooling pad, do not use any
4,500m³/h 8,000m³/h
350×330mm 350×330mm
6-8L/h 8-10L/h
60L 60L
720×720×1100mm 720×720×1200mm
50-60 ㎡ 80-100 ㎡
6
detergent to avoid damaging it.
3. Drainage Cleaning: Open the drain and empty the contents of the water tank then
use a soft cloth to wipe off and excess liquid and dirt. Please remember to also
clean any dirt on the water pump and valves.
4.Main body cleaningWhen cleaning the outside parts of the machine, please use mild
soapy water and a soft cloth. Using a strong detergent may destroy the outside surface
parts of the machine.
F.Product Applicaton:
MANUFACTURING: Mechanical, Ceramic, Metal, Textile industry, Foundry industry, Injection molding
industry and etc.
PROCESSING:
Mechanical, Electronic, Printing, Rubber, Food, Tobacco, flowers and etc.
OTHERS:
Staff Dormitory, Office, Schools, Hospital, Waiting Room, Entertainment, Supermarket, Restaurant, Bakery, Kitchen, Golf Course, Living Room, Housekeeping Department, Laboratory, Guesthouses, Car Showrooms. BPO centers and etc.
G. Troubleshooting
Error Cause Solution
- No air
-Broken fan blade
- Cooling pad or mesh
blocked
-Change blade
-Clean cooling pad/mesh
-Check fan blade/motor
-Fan blocked
-Not cooling -Pump blocked
-Pump burned
-Check water pump
-Fasten clamp/ clean water distributor
-Loose Water pipe/ Blocked
water distributor
-Not swinging
-Burned motor
-crankshaft and connecting
-Replace motor
- Reinstall and reset
rod fell off
-Leaking - Drain cap is loose - Tighten
-Water splashing
-Water pipe is loose - Check and re-install pipe
from fan blade
when in operation Note: All above details are for reference only. Please contact the distributor
at sales_mktg@colentco.com for more details. WWW.COLENTCO.COM