IWAKI WALCHEM MX-70, MX-F100Y, MX-100 User Manual

IWAKI WALCHEM
MAGNE TIC DRIVE PUMP
MX-70 & (F)100 SERIES
Thank you for having selected an Iwaki Walchem MX-70/100 Series magnetic drive pump. This instruction manual deals with the correct handling, maintenance, inspection and troubleshooting procedures for the MX magnetic drive pump. Please read through it carefully to ensure the optimum performance, safety and long service of your pump.
Item Page
1 Unpacking and Inspection.............................................................................................1
2 Identification.................................................................................................................1
3 Specifications................................................................................................................2
4 Handling........................................................................................................................ 2
5 Installation and Operation .............................................................................................3
6 Assembly.......................................................................................................................4
7 Maintenance and Inspection.......................................................................................... 5
8 Parts Description and Exploded View ..........................................................................6
9 External Dimensions and Weight ................................................................................. 7
P/N 180243 Rev. A July 2003
1 UNPACKING AND INSPECTION
Open the package and check that the product conforms to your order. Also, check each of the following points. For any problem or inconsistency, contact your distributor at once.
1. Check that the model number indicated on the nameplate conforms to the specifications of your order.
2. Check that all the accessories you ordered are included.
3. Check that the pump body and parts have not been accidentally damaged or that any bolts have not been loosened in transit.
2 OPERATING PRINCIPLE
The centrifugal pump is driven by pair of magnets which are incorporated in the impeller and motor shaft. The sealless pump structure eliminates shaft seals such as conventional mechanical seals because the pump chamber is shielded by the casings and the impeller is operated by the magnets. The combined coupling torque of the drive magnet and impeller magnet gives sufficient driving power against the motor torque.
Impeller
Discharge
Drive Magnet
Driven Magnet
Spindle
Suction
1
3 MODEL IDENTIFICATION GUIDE
MX-F 100 V T Y L
1 2 3 4 5 6
1. Series name
MX: GFRPP casing material MX-F: CFRETFE casing material
2. Pump Size code
70: Not available for MX-F models 100: Available for MX and MX-F models
3. Wet end material
MX: V: FKM O-ring E: EPDM O-ring MX-F: RV: PTFE bearing KV: SiC bearing FKM O-ring FKM O-ring
4. Suction/Discharge Port Connections
Blank: Hose connection (available for MX (GFRPP) only) T: Threaded connection
5. Impeller Code
MX: No code MX-F: Y for 50/60 Hz Z for 60 Hz only
6. Motor voltage code
Blank: 1 phase 100V L: UL Listed
-
2