![](/html/c2/c2d3/c2d3a6f680f9e8c80a0eb84fbf264fee53f81e5df05182c3e3b1c8132bf184dc/bg2.png)
Thank you for having selected an Iwaki Walchem MX-70/100 Series magnetic drive pump.
This instruction manual deals with the correct handling, maintenance, inspection and
troubleshooting procedures for the MX magnetic drive pump. Please read through it carefully
to ensure the optimum performance, safety and long service of your pump.
Contents
Item Page
1 Unpacking and Inspection.............................................................................................1
2 Identification.................................................................................................................1
3 Specifications................................................................................................................2
4 Handling........................................................................................................................ 2
5 Installation and Operation .............................................................................................3
6 Assembly.......................................................................................................................4
7 Maintenance and Inspection.......................................................................................... 5
8 Parts Description and Exploded View ..........................................................................6
9 External Dimensions and Weight ................................................................................. 7
P/N 180243 Rev. A July 2003
![](/html/c2/c2d3/c2d3a6f680f9e8c80a0eb84fbf264fee53f81e5df05182c3e3b1c8132bf184dc/bg3.png)
1 UNPACKING AND INSPECTION
Open the package and check that the product
conforms to your order. Also, check each of
the following points. For any problem or
inconsistency, contact your distributor at
once.
1. Check that the model number indicated on
the nameplate conforms to the
specifications of your order.
2. Check that all the accessories you ordered
are included.
3. Check that the pump body and parts have
not been accidentally damaged or that any
bolts have not been loosened in transit.
2 OPERATING PRINCIPLE
The centrifugal pump is driven by pair of magnets which are incorporated in the
impeller and motor shaft. The sealless pump structure eliminates shaft seals such as
conventional mechanical seals because the pump chamber is shielded by the casings
and the impeller is operated by the magnets. The combined coupling torque of the drive
magnet and impeller magnet gives sufficient driving power against the motor torque.
Impeller
Discharge
Drive Magnet
Driven Magnet
Spindle
Suction
1
![](/html/c2/c2d3/c2d3a6f680f9e8c80a0eb84fbf264fee53f81e5df05182c3e3b1c8132bf184dc/bg4.png)
3 MODEL IDENTIFICATION GUIDE
MX-F 100 V T Y L
1 2 3 4 5 6
1. Series name
MX: GFRPP casing material
MX-F: CFRETFE casing material
2. Pump Size code
70: Not available for MX-F models
100: Available for MX and MX-F models
3. Wet end material
MX: V: FKM O-ring E: EPDM O-ring
MX-F: RV: PTFE bearing KV: SiC bearing
FKM O-ring FKM O-ring
4. Suction/Discharge Port Connections
Blank: Hose connection (available for MX (GFRPP) only)
T: Threaded connection
5. Impeller Code
MX: No code
MX-F: Y for 50/60 Hz
Z for 60 Hz only
6. Motor voltage code
Blank: 1 phase 100V
L: UL Listed
-