IWAKI PUMPS APN-085E, APN-085LE, APN-085V-D4, APN-085LN, APN-085HE Instruction Manual

...
IWAKI Air Pump
APN-085-D4
Instruction Manual
Read this manual before use of product
Thank you for selecting an IWAKI APN-085-D4 air pump. This instruction manual deals with "Safety Instructions", "Outline", "Installation", "Operation" and "Maintenance" sections.
Please read through this instruction manual to ensure the opti­mum performance, safety and service of your pump.
Contents
Safety Instructions ······················································· 1
Outline 1. Unpacking & Inspection····························· 3
2. Operating principle ·································· 3
3. Identification code···································· 4
4. Specifications ········································· 4
5. Outer dimension ······································ 5
6. Performance curve ··································· 6
7. Overview & Label ···································· 6
8. Part names & Str ucture ······························ 7
Installation 1. Before installation ···································· 8
2. Installation/Tubing/Electrical wiring ············ 10
Operation 1. Before operation ····································· 13
2. Pump operation ······································ 14
Maintenance 1. Troubleshooting ······································ 16
2. Maintenance & Inspection ························· 16
3. Wear part replacement ······························ 18
This instruction manual should be kept on hand by the end user
for quick reference.
Contact us or your nearest distributor if you have any questions.
Important Instruction
For the Safe and
Correct Handling of the Pump
"Safety Instruction" section deals with important details about handling of the product. Before use, read this section carefully for the prevention of personnel injury or property damage.
Observe the instructions accompanied with "WARNING" or "CAUTION" in this manual. These instructions are very impor­tant for protecting pump users from dangerous situations.
The symbols on this instruction manual have the following meanings:
Nonobservance or misapplication of the
WARNING
CAUTION
Indicates a prohibited action or procedure. Inside or near this cir­cle, a concrete and practical image of the activity to be avoided is depicted.
Indicates an important action or procedure which must be per­formed or carried out without fail. Failure to follow the instruc­tions herein can lead to malfunction or damage to the pump.
Export Restrictions
Technical information contained in this instruction manual might be treated as controlled technology in your countries, due to agreements in international regime for export control. Please be reminded that export license/permission could be required when this manual is provided, due to export control regulations of your co untr y.
contents of “Warning” section could lead to a serious accident which may result in death.
Nonobservance or misapplication of the contents of “Caution” section could lead to personal injury or property damage.
Types of Symbols
Electrical shock
Prohibited
Prohibited
Safety Instructions
Prohibited
Prohibited
Caution
Caution
Prohibited
WARNING
Turn off power before service
Risk of electrical shock. Be sure to turn off power to stop the pump and related devices before service is performed.
Do not use the pump in any condition
other than its intended purpose
The use of the pump in any conditions other than those clearly specified may result in failure or injury. Use this product in specified conditions only.
Do not modify the pump
Alternations to the pump carries a high degree of risk. It is not the manufacturer's responsibility for any failure or injury resulting from alterations to the pump.
Wear protective clothing
Always wear protective clothing such as an eye protection, chemical resistant gloves, a mask and a face shield during disassembly, assembly or maintenance work.
Use specified power only
Do not apply power other than that speci­fied on the nameplate. Otherwise failure or fire may result. Ensure the pump is properly grounded.
No remodeling
Wear protectors
CAUTION
Qualified personnel only
The pump should be handled or operated by a qualified personnel with a full under­standing of the pump.
● Ventilation
Fumes or vapours can be hazardous with certain solutions. Ensure proper ventilation at the operation site.
● Do not install or store the pump:
1. Where ambient temperature falls below
0°C or exceeds 40°C.
2. Under a flammable/corrosive atmos-
phere.
Spill precautions
Ensure protection and containment of solution in the event of plumbing or pump damage (secondary containment).
Keep electric parts and wiring dry
Risk of fire or electric shock. Install the pump where it can be kept dry.
- 1 -
Prohibited
Electrical shock
Electrical shock
Prohibited
Safety Instructions
CAUTION CAUTION
Do not use a damaged pump
Use of a damaged pump could lead to an electric shock or death.
Stop operation
If you notice any abnormal or dangerous conditions, suspend operation immediately and inspect/solve problems.
Preventative maintenance
Follow instructions in this manual for replacement of wear parts. Do not disas­semble the pump beyond the extent of the instructions.
Do not damage the power cable
Do not pull, knot, or crush the power cable. Damage to the power cable could lead to a fire or electrical shock if cut or broken.
Do not use the pump in a wet location
The pump is not waterproof. Use of the pump in wet or extremely humid locations could lead to electric shock or short circuit.
Damaged power cable
Do not use any damaged power cable for the prevention of a fire or electrical shock. The cable is not replaceable, so that the whole pump unit needs to be replaced when the cable is damaged.
Disposal of a used pump
Dispose of any used or damaged pump in accordance with local rules and regulations. If necessary, consult a licensed industrial waste disposal company.
- 2 -
Outline
Before use, check the specification, limitation and hazardous nature of the pump.
1. Unpacking & Inspection
Open the package and check that the product conforms to your order. If any problem or inconsistency is found, immediately contact your distributor.
1. Check the nameplate to see if the information such as model codes, discharge capacity and discharge pressure are as ordered.
2. Check for transit damage, deformation and loose bolts.
2. Operating principle
The APN- 085-D4 is a diaphragm type air pump and is designed to be built into various devices such as a gas analyser and for contamination-free gas compression, vacuum and deliver y. The rotary motion of the motor is converted through a connecting rod to the reciprocation of the diaphragm in the pump chamber, where gas is transferred from the inlet to outlet.
IN OUT
Valve
Diaphragm
Connecting rod
- 3 -
Outline
3. Identification code
APN - 085 L V X - D4 - 02
a b c d e f
a. Pump size
b. Pump head
No code : Corrosive resistant (Molded diaphragm ) L : High vacuum (Horizontally oriented) H : High vacuum (Vertically oriented)
c. Diaphragm/Valve materials
N : NBR E : EPDM V : FKM
d. Pump connection
No code : ø8 tube connection X :
Rc1/4 female thread connection (JIS taper pipe thread)
X1 :
G1/4 female thread connection (JIS parallel pipe thread)
e. Motor
D4 : 24V BLDC motor (with 1-5VDC control signal)
f. Special specification
No code : Standard 01-99 : Special design
4. Specifications
■ Pump Performance at 24VDC (power voltage) and 5VDC (control signal)
Max. dis-
Max. air
Typ e
APN-085V
APN-085E
APN-085LV/HV
APN-085LE/HE
APN-085LN/HN
NOTE1. Observe the maximum discharge pressure of 0.08MPa. NOTE2. Allowable gas temperature range is 0-40°C. NOTE3. Allowable ambient temperature range is 0-40°C. Observe the
NOTE4. Both the inlet and outlet of the pump are Rc1/4 female thread
ow
pressure
(L/min)
6 0.08
lowest starting temperature at the start of operation.
connections (JIS taper pipe thread) or G1/4 female thread connections (JIS parallel pipe thread).
charge
(MPa)
Max.
vacuum
(kPa)
61.3
34.66
■ Wet end material
Parts Pump head GFRPP
Diaphragm Valve Valve seat GFRPP Retainer plate GFRPPS
Screw
Gasket (X1 type) FKM FKM FKM
GFRPP : Glass fiber reinforced polypropylene NBR : Nitrile Butadiene Rubber FKM : Fluorine-contained rubber EPDM : Ethylene propylene diene monomer GFRPPS : Glass fiber reinforced polypropylene sulfide SUS304 : Austenite stainless steel
Model
LN/HN V LV/ H V E LE/HE
NBR FKM EPDM
SUS30 4
equiv
Motor Connection
Power
Rated
con.
current
(A)
GFRPPS
SUS30 4
equiv
Tub e Thread
(W)
15 1.2 ø8
-
Rc1/4
Rc1/4
or
G1/4
-
Weight
(kg)
1.3
GFRPPS
Lowest starting
temp.
(°C)
10
5
0
SUS30 4
equiv
- 4 -- 4 -
5. Outer dimension
APN-085
ø8
ø4
APN-085- L type
2-Rc1/4
Outline
APN-085L
17
80
ø71
12
Total length(136)
12
106
17
APN-085- L type
ø8
ø4.8
2-Rc1/4 or 2-G1/4
ø72
80
ø72
Total length (121)
111
(121)
APN-085H
(130)
ø4.8
APN-085- H type
2-Rc1/4 or 2-G1/4
(130)
(125)
5
ø8
18
5
ø72
80
ø72
12 12
Total length (140)
(122)
(130)
5.5
114
21.5
5.5
23
18.5
5
80
66
- 5 -- 5 -
Outline
6. Performance curve
APN-085
Discharge pressure
(MP a)
Vacuum pressure
(kPa) [abs]
APN-085 L/H
Discharge pressure
(MP a)
Vacuum pressure
(kPa) [abs]
0.1 0
0.08
0.06
0.04
0.02
101.3
87. 98
74.6 5
61.32
47. 99
34.66
21.33
8.00
0.10
0.08
0.06
0.04
0.02
101.3
87.98
74.65
61.32
47.99
34.66
21.33
8.00
0
1 2 3 4 5 6
0
1 2 3 4 5 6
Vacuum 74.65k Pa [abs]
Vacuum 87.98kPa [a bs]
Vacuum 101.3kPa [a bs]
Discharge pressure 0MPa
Vacuum 74.65k Pa [abs]
Vacuum 87.98kPa [a bs]
Vacuum 101.3kPa [a bs]
Discharge pressure 0MPa
AIR FLOW
(L/min)
AIR FLOW
(L/min)
7. Overview & Label
Outlet
Pump body (Driven unit)
An installation location should be free from liq­uid spillage.
- 6 -- 6 -
Pump head
Inlet
Nameplate
Model and MFG. No. (Production number) are described.
Motor
Base
Anchor the pump with bolts.