![](/html/1a/1ab5/1ab5f6cf5c66812aff00048953480ab1fb4e77b46db51ff0b0e92e07d6a2d3f8/bg1.png)
IWAKI
Electromagnetic DC Metering Pump
HRP
series
Iwaki HRP metering pumps enable high-speed, accurate ow in a compact package. Designed specically
for OEM applications, the HRP pump has been sized for easy integration into many types of systems. Multiple
control options including proportional, 1:1 digital pulse following, and simple start/stop control, combined
with horizontal and vertical congurations enable the HRP pump to be customized for many applications.
• Reduce system size - Ultra-compact (4” x 2” x 3.5”) design makes it easy to t this pump into
almost any system.
• Enhanced portability - Available in 12 or 24 VDC allows for increased portability of your system.
• Ease of Integration - From simple to sophisticated, internal or external control, HRP’s 4 dierent
integrated control options ensure a custom t.
• Simplify your uid path - Vertical or horizontal porting congurations provide a smooth uid path
on every application.
Standard applications
• Sterilizing/Reprocessing Equipment
• Analytical Equipment
• Chemical Dosing
• Medical Devices
• Water Quality
• Car Wash
![](/html/1a/1ab5/1ab5f6cf5c66812aff00048953480ab1fb4e77b46db51ff0b0e92e07d6a2d3f8/bg2.png)
PTFE: Polytetrauoroethylene
Wet End Materials
Gasket
4
Valve spring
4
Gasket
3
Valve
O ring
5
1
Pump head
6
Diaphragm
Valve seat
2
Part Material Part Material
1 Pump head PVDF 5 O-ring FKM
2 Valve seat FKM 6 Diaphragm PTFE-EPDM
3 Valve Alumina Ceramic 7 Valve spring PEEK
4 Gasket PTFE * Other materials available on request
Valve seat
Pump head
Diaphragm
Material code
PVDF: Polyvinylidene diuoride
FKM: Fluorine-contained rubber
Valve
O ring
7
2
1
3
6
5
Specications
Max
Model
HRP-54V/H-1
HRP-54V/H-2
Flow Rate
ml/min
Pressure
PSI (MPa)
0.055 - 38 29 (0.2) 0-720
Discharge
Stroke
rate
spm Tube connection
1/8” x 1/4”
3mm x 6mm
4mm x 6mm
Model Identication
HRP - 5 4 V - 1 P 1 -
Series name
Drive unit
(Average power consumption)
5: 5.6W
Discharge capacity
4: 38mL/min
Pump head
V: Vertically oriented
H: Horizontally oriented
Power
Voltage
consumption WCurrentAWeight lbs
Power
Power voltage
1: 12VDC
2: 24VDC
V
DC12
5.6
DC24 1.0
HRP
series
Special version
Connection bore
Tube connection bore
No.
1.5
Ø3×Ø6
1
Ø4×Ø6
2
Ø1/8”×Ø1/4”
3
Control method
P: Pulse control
A: 4-20mA control
V: 1-5V control
S: Stop control
(kg)
1.1
(0.5)
Liquid & ambient temperature 0 - 40°C Allowable voltage deviation ±5% of rated voltage
Integrated Control Options
Control type Max Speed Operation Input signal
Pulse 720 spm 1 stroke per pulse (synchronous operation) Dry contact or open collector
4-20mA 720 spm 4-20 mA proportional to 0 -720 spm Analog 4-20 mA DC
1-5VDC 720 spm 1-5 VDC proportional to 0-720 spm Voltage 1-5 VDC (Current capacity of 25 mA or more)
Start/Stop 720 spm (xed) Pump stops during contact input Dry contact or open collector
Dimensions
HRP-54V HRP-54H
Dimensions in mm (nominal)
Model W H L a b c d e f g i j k m n o
HRP-54V
HRP-54H (51.5) (122) --- --- 5(6) --- 17.2 19.6
L L
d e
62
g
f
--- (101) (19)
k m
27
j
i W
(73)
22.5
(25)
c
b
a
d e
4
o
n
f
9.5
51.5 4.5 10 6
k m
j
H
i W
b
--- ---
IALT-00162.E July 2012
www.IwakiAmerica.com www.IwakiCustomPumps.com
Five Boynton Road • Holliston, MA • 01746 USA • Tel: 508-429-1440 • Fax: 508-429-1386 info@iwakiamerica.com