Ivy Bronx WLGN2924 Installation & Assembly

Page 1
Assembly Instruction
ToolsRequired: Flathead screwdriver,Phillipsscrewdriver,pliers, wire cutters, wire strippers, electrical tape, safety glasses, scissor. LightSource: EstimatedAssembly Time: Preparation:
present.Ifanypartsaremissingordamaged,donotattempttoassemble,install,oroperatethefixture.Contactcustomerserviceforreplacement parts.
Note: This CONVERTIBLE fixture can be mounted as pendant light or semi-flush light. Refer to respective installation steps for installations.
Warnings and Cautions
Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.
These instructions are provided for your safety. It is very important you read them completely before installing the fixture. We strongly recommend that a licensed, professional electrician perform the installation.
Disconnect fixture from power source before replacing bulbs. Make sure bulbs are given sufficient time to cool before removal. Do not subject glass parts to any shock while in operation or shattering may result.
(3)MediumBase100WbulbMaximum,Alternate bulb (3) 23W CFL Maximum.
30-45minutes
Identifyandinspectallpartsbeforebeginninginstallation.Checkpackagecontentlistanddiagramsbelowtobesureallpartsare
Package Contents
A
Ceiling Canopy
B
x1
Hex Nut
C
x3
Lock Washer
D
x1
Nipple
E
x1
Swivel
F
x1
6” Rod
G
x2
12” Rod
H
x2
Remove Frame from Socket Assembly
A. By using Scissor, cut
Straps on Socket Assembly and remove Frame from the Socket Assembly.
Crossbar Assembly x1
Socket Assembly
I
x1
Diffuser
J
x1
Cap
N
x1
Strap
Stem
x1
Flat Washer
L
x2
Rubber Washer
M
x2
Finial
O
x1
Scissor
Socket Assembly
Strap
Socket Assembly
Assembly Instructions for Pendant Light
(Step 1A - Step 7A)
STEP 1A Attach Swivel and Ceiling Canopy together
A. Thread Nipple (E) onto the Swivel (F). B. Place Ceiling Canopy (B) and Lock
K
STEP 2A - Install Swivel, Rods and Socket Assembly together
A. Determine Rods (G/H) to be assembled to
B. Pass supply wires and ground wire through
STEP 3A Install Crossbar Assembly-
A. Pass supply wires through Crossbar
-
Washer (D) over the Nipple (E), secure by threading Hex Nut (C) onto the Nipple (E), tighten until sung.
Socket Assembly (I) according to your hanging height.
chosen rods (G/H) and Swivel (F). Thread Socket Assembly (I), chosen Rods (G/H) and Swivel (F) together. Hand tighten until snug.
Suggested rods for Ceiling height : 8’ ceiling : use (2) 12” rods 9’ ceiling : use (2) 6” rods and (2) 12” rods
Supply Wires
and Ground Wire
I
Figure 2A
Assembly (A). Attach Crossbar Assembly (A) to Outlet Box with the head of the Green Ground Screw facing you. Secure it with Outlet Box Screws (not included). Tighten until snug.
Figure 1A
D
F
G
H
C
B
E
F
G
H
Outlet Box
A
Frame
1of3
Figure 3A
Outlet Box Screws
(not included)
Supply Wires
with Ground Wire
Page 2
STEP 4A Test fitting Ceiling Canopy to Crossbar Assembly
A.
STEP 5A - Wire Connections
A. Use standard wire connectors (not included) to make all wire
STEP 6A Install Fixture Body-
A. Carefully tuck all wires into the
STEP 7A Install Diffuser and Bulb-
-
A
Remove mounting balls from the Crossbar Assembly (A). Fit Ceiling Canopy to the Crossbar Assembly (A) and secure with mounting balls. Note: The (B) should be
Ceiling Canopy snug against the and the mounting balls. If not, adjust the length of the nipple on the
Crossbar Assembly (A) by unscrewing the preassembled hex nut and lock washer and then screwing the mounting screws in or out of the crossbar until the correct length is achieved. Once the Ceiling Canopy (B) is secure, remove the mounting ball and Ceiling Canopy (B) and proceed to Step 5A.
connections. (Connectors are not included with fixture.) Twist connectors until wires are tightly joined together. Wrap each connection with approved electrical tape and carefully stuff all the connected wires into the Outlet Box.
Black wire from supply (or Red)
Ground wire
outlet box and position the Ceiling Canopy (B) over the outlet box. Align the holes in the Ceiling Canopy (B) with the mounting screws, then attach the Ceiling Canopy (B) using the previously removed mounting balls. Hand tighten until snug.
(B)
ceiling
White wire
from supply
from supply
B
Figure 4A
White wire from fixture
Black wire from fixture
Ground wire from fixture
D
Figure 6A
Hex Nut and Lock Washer
Mounting Screw
Mounting Ball
Figure 5A
A
Mounting Screw
Mounting Ball
Assembly Instructions for Semi-flush Light
(Step 1B - Step 6B)
Part F, Part G and Part H will not be used in the assembly of the Semi-Flush Light fixture. Please set aside these parts.
6” Rod
G
x2
Extra Parts include
STEP 1B Install Ceiling Canopy to Socket Assembly-
A. Pass supply wires with ground wire through Nipple (E), Ceiling
Canopy (B), Lock Washer (D) and Hex Nut (C). Thread Nipple (E) onto the Socket Assembly (I). Place the Ceiling Canopy (B) and the
Lock Washer (D) onto the Nipple (E). Secure by threading the Hex Nut (C) onto the Nipple (E). Hand tighten until snug. Cut the wires leaving approximately 6” of wire extending from the Ceiling Canopy (B).
B. Optional Swivel: Install the
swivel to the Socket Assembly (I) and then attach Nipple (E) and the Ceiling Canopy (B) to the Swivel using the Lock Washer (D) and the Hex Nut(C)asinstepA.
STEP 2B Install CrossbarAssembly-
A. Pass supply wires through Crossbar
Assembly (A). Attach Crossbar Assembly (A) to Outlet Box with the head of the Green Ground Screw facing you. Secure it with Outlet Box Screws (not included). Tighten until snug.
Figure 2B
Outlet Box Screws
(not included)
12” Rod
H
x2
D
Optional
Swivel
Figure 1B
with Ground Wire
Swivel
F
x1
C
B
E
Supply Wires and Ground Wire
I
Outlet Box
A
Supply Wires
A. Thread the beaded end of Stem (K) into Hex Coupling underside of
Socket Cluster. Hand tighten until snug.
B. Thread one Hex Nut (C) onto the end of Stem (K) and adjust it to
proper locations for rest components. You may be required to fit rest components to end of Stem (K) one more times to get the proper length of Stem (K) extruding from the Hex Nut (C).
C. This fixture uses standard bulb with medium base. Maximum 100
watts. Insert bulb and screw snugly into place.
D. Place Flat Washers (L), Rubber Washers (M) and Diffuser (J) over
the end of Stem (K) as shown. Secure by threading the another Hex Nut (C) onto the Stem (K)
and tighten until sung.
E. Place Cap (N) over the
Stem (K) and secure with Finial (O). Hand tighten until snug.
Your fixture is now assembled and ready to use. Enjoy!
Figure 7A
K
C
M
L
N
Socket
Hex Coupling
L
M
C
O
Bulb
STEP 3B Test fitting Ceiling Canopy to Crossbar Assembly-
Remove mounting balls from the CrossbarAssembly (A). Fit
A. Ceiling
Canopy to the balls. Note: The (B) should be snug against the ceiling on the Crossbar Assembly (A) by unscrewing the preassembled hex nut and lock washer and then screwing the mounting screws in or out of the crossbar until the correct length is achieved. Once the Ceiling Canopy (B) is secure, remove the mounting ball and Ceiling Canopy (B) and proceed to Step 4B.
J
(B) Crossbar Assembly (A) and secure with mounting
and the mounting balls. If not, adjust the length of the nipple
Mounting Screw
Ceiling Canopy
B
A
Hex Nut and Lock Washer
Mounting Ball
Figure 3B
2of3
Page 3
STEP 4B - Wire Connections
REPLACE SHADE
Lock Screw
A. Use standard wire connectors (not included) to make all wire
connections. (Connectors are not included with fixture.) Twist connectors until wires are tightly joined together. Wrap each connection with approved electrical tape and carefully stuff all the connected wires into the Outlet Box.
White wire
from supply
Black wire from supply (or Red)
Ground wire
from supply
STEP 5B Install Fixture Body-
A. Carefully tuck all wires into the outlet box and position the Ceiling
Canopy (B) over the outlet box.Align the holes in the Ceiling Canopy (B) with the mounting screws, then attach the Ceiling Canopy (B) using the previously removed mounting balls. Hand tighten until snug.
Figure 5B
B
White wire from fixture
Black wire from fixture
Ground wire from fixture
A
Mounting Screw
Mounting Ball
Figure 4B
A. Unlock the Finial and
remove the Cap.
B Unlock the Hex Nut on the
.
bottom end of the Cente Stem. Remove Flat Washers, Rubber Washers and Diffuser from fixture.
C.
Unscrew Lock Screws on
the top edge of the Socket Assembly and remove Inner Shade. Replace the Inner Shade with a new one and secure with Lock Screws previously removed.
D. Reverse above steps to
reinstall com previously removed.
FINISH: VALIANT BRONZE
ponents
PENDANT
5” Dia.
1
2
r
Flat Washer
Diffuser
Flat Washer
Inner Shade
Hex Nut
Rubber Washer
Rubber Washer
Hex Nut Cap
Finial
46.25” OVERALL HEIGHT (2) 6”
AND (2) 12” RODS
INCLUDED
STEP 6B Install Diffuser and Bulb-
A. Thread the beaded end of Stem (K) into Hex Coupling underside of
Socket Cluster. Hand tighten until snug.
B. Thread one Hex Nut (C) onto the end of Stem (K) and adjust it to
proper locations for rest components. You may be required to fit rest components to end of Stem (K) one more times to get the proper length of Stem (K) extruding from the Hex Nut (C).
C. This fixture uses standard bulb with medium base. Maximum 100
watts. Insert bulb and screw snugly into place.
D. Place Flat Washers (L), Rubber Washers (M) and Diffuser (J) over
the end of Stem (K) as shown. Secure by threading the another Hex Nut (C) onto the Stem (K) and tighten until sung.
E. Place Cap (N) over the Stem (K) and secure with Finial (O). Hand
tighten until snug.
Your fixture is now assembled and ready to use. Enjoy!
Figure 6B
K
C
M
L
N
Socket
Hex Coupling
L
M
C
O
Bulb
J
SEMI-FLUSH
Base
Medium
Bulb
(3) 100W
(Not Supplied)
7.5”
6.5”
7”
16.75” Dia. 20” Dia.
5” Dia.
16.75” Dia. 20” Dia.
NOTE: ALL DIMENSIONS ARE ROUNDED UP TO THE NEAREST 1/4"
PART NUMBER REPLACEMENT PART
NO.
1
2
3
4
3
3
6”L ROD
12”L ROD
DIFFUSER
FABRIC SHADE
4
6.5”
4
10.25”
7”
QTY.
2
2
1
1
3of3
Loading...